Audiopole PX-360 User manual

!
!
!
!
!
!
!
!
!
!
!
!
PX
-360
!
!
!
!
!
PROFESSIONAL POWER AMPLIFIER
!
!
!
!
!
!
!
!
!
!
!
!
!
PROFESSIONAL STEREO
AM
PLIFIE
R
PX-360
!
!
!
!
!
!
!
!
USER’S MANUAL

2!
!
!
2
POWER SUPPLY
Ensure that the insource voltage (AC outlet) matches the voltage rating of the product. Failure to do so could result in
damage to the product and possibly the user. Unplug the product before electrical storms occur and when unused for
long periods of time to reduce the risk of electric shock or fire.
EXTERNAL CONNECTION
Always use proper ready-made insulated mains cabling (power cord). Failure to do so could result in shock/death or
fire. If in doubt, seek advice from a registered electrician.
FUSE
To prevent fire and damage to the product, use only the recommended fuse type as indicated in this manual. Do not
short-circuit the fuse holder. Before replacing the fuse, make sure that the product is OFF and disconnected from the
AC outlet.
PROTECTIVE GROUND
Before turning the unit on, make sure that it is connected to Ground. This is to prevent the risk of electric shock.
Never cut internal or external Ground wires. Like wise, never remove Ground wiring from the Protective Ground
Terminal.
OPERATING SAFETY INSTRUCTIONS
Read these instructions. Follow all instructions. Keep these instructions. Do not discard. Heed all warnings. Only use
attachments/accessories specified by the manufacturer.
This symbol indicates that the disposal of this product is submitted to local regulations. Please
contact your local dealer.
DISPOSAL
Important Safety Instructions
This symbol, wherever used, alerts you to the presence of un-insulated and dangerous voltages
within the product enclosure. These are voltages that may be sufficient to constitute the risk of
electric shock or death.
This symbol, wherever used, alerts you to important operating and maintenance instructions.
DO NOT REMOVE ANY COVERS
Within the product are areas where high voltages may present. To reduce the risk of electric shock do not remove
any covers unless the AC mains power cord is removed. Covers should be removed by qualified service personnel
only. No user serviceable parts inside.
POWER CORD AND PLUG
Do not tamper with the power cord or plug. These are designed for your safety. Do not remove Ground connections!
If the plug does not fit your AC outlet seek advice from a qualified electrician. Protect the power cord and plug from
any physical stress to avoid risk of electric shock. Do not place heavy objects on the power cord. This could cause
electric shock or fire.
SERVICING
Refer all servicing to qualified service personnel only. Do not perform any servicing then those instructions contained
within this User’s Manual.

3!
!
I
nd
e
x
!
!
!
!
!
!
!
1. Introduction …………………………………………………………………….….. 3
!
2. Main Features………………………………………………………………………. 3
!
3. Functions …………………………………………………….…………………….. 4
!
4. Applications………………………………………………...……………….…….. 6
!
5. Technical Specifications ……………………………...……………………...…… 8
!
6. Warranty ……………………………………………………………………….…… 9
!
2

4!
!
1
I
n
t
r
odu
c
t
i
on
Thanks for the acquisition of the PX-360 AUDIOPOLE. This professional power amplifier was
developed for fixed installations requiring limited space in the bays.
The PX-360 has a high efficiency thanks to his Class-D technology and can deliver 2x180 WRMS
on 4 Ohms. It also works securely with 2 Ohms loads. A Bridge mode enables to power a mono
device like a subwoofer or a low impedance loudspeakers line.
!
!
2
Main Features
!
•Class-D
•2 x 180 W / 4 Ohms,
•360 W / 8 Ohms (Bridge)
•Balanced inputs on Euroblock connectors,
•Speaker outputs an Euroblock connectors,
•Stereo and Bridge modes,
•Limiter
•1U rack
•3.7 kg
!
3

5!
!
3
!
F
un
c
t
i
on
s
!
FRONT PANEL
!
!
1–POWER
Power switch.
2–
V
o
l
u
m
e
Volume control.
3–POWERON
Power indicator.
4–SIG
Signal indicator.
!
5–
PROT
Protection indicator. If the amplifier fails, the Led lights up, the output being automatically muted. Check
the cable connection between the amplifier and the speaker. Also check that the vent grille is not
obstructed. If the amplifier is installed into a bay, there is a risk that the cooling is not sufficient and the
temperature can raise to the upper limit level where the protect mode is triggered.
6 –
C
L
IP
Clipping indicator. The Led lights up as soon as the distortion rate exceeds 0.5%. The input level is too
high and it is necessary to decrease the volume or to switch the limiter on.
! !
!
4

6!
!
3
!
F
un
c
t
i
on
s
!
REAR PANEL
!
!
!
!
!
!
1–Mains and fuse
Main power supply socket. Make sure that the cable plug is correctly inserted in the socket.
The compartment located below the socket contains the fuse. In the event of change, it is imperative to
use a fuse with identical electrical characteristics under threat of damage to the unit.
2 & 3 –
Input connectors
Balanced input Euroblock.
4–
MODE
Mode selector: STEREO/BRIDGE.
!
5–LIMITER
Limiter On/Off switch.
6–
Output connectors
Speakers output
Euroblock.
!
5

7!
!
4
A
pp
li
c
a
t
i
on
s
Two work modes can be selected: Stereo or Bridge Mono.
!
•Stereo mode
!
In Stereo mode, channel 1 and 2 work separately using their own connectors and controls.
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Sélecteuren position STEREO
!
6

8!
!
4
!
A
pp
li
c
a
t
i
ons
!
!
!
•
B
r
i
dg
e Mode
!
In Bridge Mono mode the power capacities of the two channels are cumulated to be used with one
single load.
The input signal must be connected to channel 1 of the amplifier. Channel 2 is not used and its volume
control must be set to zero.
Warning, the following connection rules must be respected:
• the positive terminal (+) of output 1 must be connected to the positive terminal (+) of the
speaker.
• the positive terminal (+) of output 2 must be connected to the negative terminal (-) of the
speaker.
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
7

9!
!
6
T
e
c
hn
ical Specifications
!
Stereo Power
!
2
Ω
(EIAJ)
!
2x400 W
!
4
Ω
(RMS)
!
2x180 W
!
8
Ω
(RMS)!
!
2x100 W!
Bridge Mode Power
!
8
Ω
(RMS)
!
360 W
!
4
Ω
(EIAJ)!
!
800W!
!
Distortion (THD)
!
<0.05%
!
Frequency Response
!
20 Hz –20 kHz (+0/-1dB)
!
Damping factor,1kHz
!
>180 @8
Ω
!
S/N ratio, A weighted
!
> 96 dB
!
Gain (V)
!
28 ± 0,5 dB
!
Input Sensitivity
!
0.9 - 1.1 V(0+/1 dBv)
!
Input Clipping
!
10 Vrms (+22 dB)
!
Input Impedance
!
20
kΩ
balanced or 10
kΩunbalanced
!
Controls
Front panel:On/Off Power Switch,volumechannel 1&2
Rear panel:Limiter, Stereo/Bridge selector
Indicators
POWER ON : Blue Led
SIGN : Green Led
PROT : Red Led
CLIP : Red Led
!
Connectors
Inputs:Euroblock
Outputs: Euroblock
!
Load Protection
!
On/Off Mute,DC fault grounding relay,internal fault fuses
!
Power Supply
!
110 - 120 V or 220-240V50 ~60 Hz
!
Dimensions(L xHxD)
!
483x44 x 281mm
!
Net Weight
!
3.7kg
!
8

!
7
Warranty!
!
!
!
This device is warranted parts and labor against any manufacturing defects for a period of two
years from the date of purchase by the first user.
!
C
ond
i
t
i
on
s
!
1. The unit has been installed and implemented by observing the safety instructions in this
operating manual.
2. The device was not diverted from its destination, either voluntary or accidental, and
suffered no deterioration or modification other than those described here or explicitly
authorized by AUDIOPOLE.
3. All modifications or repairs have been carried out by an authorized service station.
4. The defective product must be returned with the dealer who made the sale or to an
authorized service station with proof of purchase.
5. The device was properly packaged to avoid damage in transport.
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
22, rue Édouard Buffard, Z.A.C. de la Charbonnière, Montévrain - 77771 Marne-la-Vallée Cedex 4 - France
Tél : + 33 (0)1 60 54 32 00 - Fax : + 33 (0) 1 60 54 31 90 - www.audiopole-pa.com - www.audiopole.fr
Table of contents
Other Audiopole Amplifier manuals

Audiopole
Audiopole PX3 User manual

Audiopole
Audiopole CLIMAX 3200 DSP User manual

Audiopole
Audiopole ZONER 4-120 User manual

Audiopole
Audiopole PA 4-250 User manual

Audiopole
Audiopole FORCE 700 User manual

Audiopole
Audiopole PA 225 User manual

Audiopole
Audiopole PX-140 User manual

Audiopole
Audiopole CLIMAX 1002 User manual

Audiopole
Audiopole A 241 User manual

Audiopole
Audiopole PX 500 User manual