Aussie Traveller K3600-50 Instruction sheet

User manual
K3600-50
Installation guidelines
and user manual
Please read all instructions carefully before using the unit and keep instructions for future reference
K3600-50

1. Introduction
2. Installation guide
3. Operating instructions
4. Product Maintenance
5. Troubleshooting guide

Introduction

Introduction
Exploded Parts List
Key components:
1.
Air-conditioner main unit ×1
2.
Reinforced roof support ×1
3.
Mounting frame ×1
4.
Plenum unit ×1
Fastener components:
5.
M8 x 110 mm bolts ×4
6.
Fixing washer ×4
7.
Round washer ×4
8.
Spring washer x4
9.
Screw for plenum ×4
5
6
7
8
9
1
2
3
4

Introduction
1. Operations
K3600 creates a comfortable environment for a recreational vehicle or
caravan.
It is recommended the user should consult caravan manufacturer to
understand total heat load, as well to choose a suitable Air-conditioner,
some tips to reduce heat load and improve performance:
Park the caravan at a shaded place to avoid direct
sunshine exposure, close all the doors, skylights and
windows, draw the curtains and open the sunshade.
Turn off unnecessary electrical appliances within the
caravan to reduce the heat-load.
Turn on the air-conditioner in advance if exceptionally
high temperatures are expected.
Set suitable temperature by remote controller to avoid
frequent start and stop.
ON

Introduction
2. Condensation
Condensation usually happens in areas where the air humidity is
comparatively low and when warm moist air within the caravan meets with
the cold air from the outlet. In this case, please pay attention to the
following measures:
Close all the doors, skylights, windows and draw the
curtains to decrease any warm moist air from
entering.
In the operation of the air-conditioner, condensate
(water) will be produced on the roof. Please select
High Fan mode to increase circulation to decrease
condensation degree.
Please note that damage caused by the condensate
water is not covered by warranty.

Introduction
3. Choosing and using generator
K3600 requires an AC power source, and may require a generator in
some remote circumstance.
Requirements for inverter generator include: efficient power source;
stable current; output sine wave, which shall meet the requirements of the
compressor. The user should consult with the generator supplier for their
recommendations.
Please note that damage caused by using a
generator is not covered by warranty.

Installation guidance
Installation requirements
The RV or Caravan roof and cutout needs to be able to support the
air-conditioners weight (45kg).
Minimum thickness of roof: ≥23mm; maximum thickness of roof:
≤55mm.
Installation instructions
Read and understand this Manual thoroughly before installation
Abide by the wiring rules in theinstallation.
Do not add other parts or restructure the product during theinstallation.
The installers shall be qualified refrigeration technicians
Consult with Aussie Traveller in the case of unusual applications or
installation conditions that are not specifically covered by this manual.

Installation guidance
Preparation
The main unit should be installed
in the center of roof, it is
recommended to have a min
100mm space around the top
unit
Before installing please verify
there is suitable space in the
ceiling to accept the plenum
The installation position
(400x400mm) should avoid
skylight, solar panels, roof vents,
heaters, lights and all electrical
connections

Installation guidance
Preparation (continued)
Please check with your caravan manufacturer to confirm the roof can
bear the weight of the air-conditioner and maintain a level surface to
avoid accumulating condensate/water
Please consult with your caravan manufacturer for the best solution if
there is a requirement to cut a mounting hole if provision has not been
made for an air conditioner
Cut a 400 x 400 hole and reinforce with the appropriate sized timber
frame (see pic). This is to ensure the roof will not crush on installation
and air does not enter the ceiling space
In some instances a separate metal frame may be required to reinforce
the roof structure. Consult with your caravan manufacturer/installer to
reach a suitable solution.

Installation guidance
Installation
Remove the roof support from
carton and make sure it is
aligned correctly.
Add a continuous line of sealant
on the back of the support and fit
into the cut out ensuring that it is
aligned correctly.
Install main unit carefully on roof
support.
hole
Glue width
10-12mm

Installation guidance
Installation (continued)
Match the corresponding active
(brown), neutral (blue) and
ground wire (yellow-green) and
tighten up screws to make sure
power is properly connected.
Insert Plenum mounting bracket
through the ceiling to base. Pay
attention as the “C” hook must
match the corresponding “C”
area on the base. Finally fasten.
Insert 4xM8 bolts, washers,
spring washer and metal plate
via mounting frame to the base.
Plug the connectors on the
plenum to the base.
Push plenum into outlet duct and
fasten 16xM4 screw on the
bottom. Finally add the filters to
the sides of the plenum.
Important: ensure the tightening
torque from 12 to 14 NM

Operation Instruction
Tips
1.
Be careful when installing the unit on the roof of the caravan, crawl
boards may be required.
2.
There may be wires between the roof and the ceiling. When cutting
into the roof, make sure the power is isolated to prevent the risk of
electric shock.
3.
Installation and maintenance of the air-conditioner must only be
performed by personnel with appropriate trade qualifications and
holding current licenses for such work.
4.
Ensure the air-conditioner has been installed in compliance with the
instructions of this manual. Incorrect installation methods or alteration
of the product may cause damage to the product or personal injuries
to theuser.
5.
Make sure the external electric supply socket of the caravan air-
conditioner is effectively grounded in accordance with appropriate
electrical standards. Failure to ground the unit correctly may cause
electric shock or fire.
6.
Ensure that your electrical supply and wiring is correctly sized for the
power and meets appropriate electrical standards.
7.
Switch on the power to the air-conditioner at the isolationbreaker.
8.
The caravan air-conditioner must be switched on for electric leakage
detection after installation.
9.
Use the remote controller to operate the air-conditioner.

Operation Instruction
Tips (continued)
10.
To select the COOL mode, adjust the set point temperature to three
degrees lower than the room temperature, the unit will start to blow
cold air after the compressor starts –approximately 3 minutes.
11.
To select the HEAT mode, adjust the setting temperature as three
degrees higher than the room temperature.
12.
If you are not to use the air-conditioner for an extended period, please
isolate the power supply.
13.
This appliance is not to be used by persons (including children) with
reduced physical, sensoryor mental capabilities, or lack of experience
and knowledge, unless they are under supervision.
Note: After selecting the COOL/HEAT mode, the
compressor will have a delay start for three minutes.

Operation Instruction
Remote control
Mode Display
AUTO/COOL/DRY/FAN/HEAT
Setting Temperature Display
℃
/
℉
Room temperature Display
℃
/
℉
Timer OFF Display
Timer ON Display
Real Time Clock
POWER Key
Power On and Off
LED Key
Turn On and Turn Off LED
MODE Key
Circular Select AUTO
/COOL/DRY/FAN/HEAT Mode
DISPLAY Key
Control Plenum Display On and Off
LOCK Key
Spare
TIME+ Key
TIME- Key
CLOCK Key
℃
/
℉
Key
Switch Temperature Between
Celsius and Fahrenheit
Fan Speed Display
Low/Medium/High/Auto
LED On/Off Display
Lock Function Display
Clean Filter Function Display
Sleep Function Display
Up Key (Set Temperature)
Down Key (Set Temperature)
CANCEL Key
Turn Off Clean Filter
Display
FAN Key
Circular Select
Low/Medium/High Speed/AUTO
ON Key
Setting Timer Of The Unit Turn
On
OFF Key
Setting Timer Of The Unit Turn
Off
ENTER Key
SLEEP Key
Only Available In COOL and
HEAT Modes
RESET Key
Factory Reset

Operation Instruction
Plenum Display
COOL Display
LED Display
HEAT Display
Touch Screen Key
Temperature Display
AUTO Display
Clean Filter Display
Fan Display
Operation of the remote controller
Turn on
Press the ”Power ” key, the unit turns on, the buzzer in the plenum beeps
one time and the running mode and the temperature will be displayed.
Turn off
Press the “Power ” key again, unit turns off and the plenum will display
nothing.
AUTO mode
Press the “MODE” key, select the ” mode, Fan volume will set
automatically ,and it is adjustable. Press “FAN” button to get expected volume.
Press the up “TEMP+” or down “TEMP-” key to set desired temperature.
Depending upon the difference between the set temperature and the ambient
temperature the air-conditioner will automatically decide cooling or heating.
COOL mode
Press the “MODE” key, select the ” mode, and Press the down “TEMP-”
key to set the temperature lower than the room temperature. Press the “FAN
” key to select different speed and the plenum will display ” and the
set temperature.

Operation Instruction
Operation of the remote controller (continued)
DEHUMIDIFY mode
Press the “MODE” key, select the ” mode, the air volume is un- adjustable
to stay at minimum level. Press the down “TEMP-” key to set the temperature
1℃ lower than the room temperature, and the plenumwill display ” and the
set temperature.
FAN mode
Press the “MODE” key, select the ” mode, Press the “FAN” key. Select
Low/Medium/High/AUTO. The plenum will display ” and the indoor
environment temperature.
HEAT mode
Press the “MODE” key, select the ” mode, Press the up “TEMP+” key to
set the temperature higherthan the room temperature. Press the ” key
to select different speed. And the plenum will display ” and the set
temperature.
Celsius and Fahrenheit degree change
In any mode, press the“℃/℉”key, you can vary temperature between
Celsius and Fahrenheit.
LED turn on and turn off
Press the LED key, the LED light turn on, Press the LED key again, the LED
light turn off.
Turn off
Press the “Power ” key again, unit turns off and the plenum will display
nothing.

Operation Instruction
Operation of the remote controller (continued)
TIMER ON
Press the” TIMER ON” key, the Hour digit will flash. Press “TIME+” or “TIME-
” key to set desired time for “TIMER ON”. Press the “OK” key to confirm setup
is done.
TIMER OFF
Press the “TIMER OFF” key, the Hour digit will flash. Press “TIME+” or “TIME-
” key to set desired time for “TIMER OFF”. Press the “OK” key to confirm setup
is done.
Clock set
Press “CLOCK” button to set the time : keep in pressing “TIME+” or “TIME-”
key to select a desired time
Sleep
Press the” SLEEP” key to display sleep icon on the remote screen, under this
function the temperature after 1 hour will automatically increase 1 degree, and
after 2 hours it will raise 2 degrees, then it will maintain the same temperature
until it automatically turns off 8 hours after setting.
In contrast, in heating mode will automatically reduce 1 degree and reduce 2
degrees after 2 hours, then it will maintain the same temperature until it
automatically turns off 8 hours after setting.

Operation Instruction
•
THE REMOTE CONTROLLER WILL ONLY OPERATE IF DIRECTLY
POINTED AT THE PLENUM. It will beep once when the signal is
received. Adjust the distance and angle if the plenum does not
respond.
•
The unit will blow cold air in COOL mode and hot air in HEAT mode.
•
When the unit is on, press the “DISPLAY” key on the remote controller
to display on the plenum.
•
The air-conditioner features power cut memory and automatic resets
after restarting.
•
Low temperature heating will cause frosting, during which it is normal
to show “DF” on the plenum.
•
When the outside temperature is lower than 0 degrees, the heating
effect is reduced. Adopt alternative methods of heating.
•
If the device is to be left unused for an extended period, remove the
batteries from the remote controller.

Specification Parameters
Specifications
Model
A
Power supply
220~240V/50Hz
Refrigerant charged
R407C/850g
Rated cooling capacity (W)
3600
Rated heating capacity (W)
3600
Input power for cooling (W)
1400
Input power for heating (W)
1200
Rated current for cooling (A)
5.9
Rated current for heating (A)
5.4
Maximum input power (W)
1600
Maximum current (A)
7.2
Maximum design pressure (kPa)
2900
Minimum design pressure (kPa)
1840
Maximum air flow (l/s)
50
Installed weight (kg)
45
Main unit dimension
Height 290mm Width 860mm
Length1130 mm
Plenum unit dimension
Height 40mm Width 540mm Length
536mm
Note
1.
All parameters listed are subject to change without notice and the nameplates on the machine shall prevail;
2.
E&OE All values are approximate & subject tochange.
Table of contents
Popular Air Conditioner manuals by other brands

American Standard
American Standard 4A6V8024A1000B Service facts

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

LG
LG L5UC728FA0 installation manual

Mitsubishi Electric
Mitsubishi Electric MSZ-LN18VG2W operating instructions

Daikin
Daikin Split Sensira R32 Service manual

Mitsubishi Electric
Mitsubishi Electric Mr. Slim PUZ-M200YKA2.UK Service manual

Panasonic
Panasonic CU-2S18NBU-1 Service manual

TemperZone
TemperZone OSA 840RKTB installation guide

Diplomat
Diplomat DX-80CHRC instruction manual

MrCool
MrCool Signature Series Owners & installation manual

Mitsubishi Electric
Mitsubishi Electric MFZ-KA25VA Service manual

Dimplex
Dimplex DCEVP5WG instruction manual