Installation
Guide
BBVBBV
Model covered
EX-4
Tx1000 Keypad Expander

EX-4 Tx1000 Keypad Expander Installation Manual Revision 1.0 March 1998 Page 2
TABLE OF CONTENTS
1. Pre-installation Checks and Safety Procedures 3
Unpacking 3
Important safety precautions 3
Equipment Contents 4
2. Introduction 5
General 5
Technical specification 5
3. Installation 6
Operating voltage 6
Connection Details 6
Fig. 1 EX-4 connections
Diagnostic aids 6
4. Operation 7
Operation 7
5. Example system diagrams 8

EX-4 Tx1000 Keypad Expander Installation Manual Revision 1.0 March 1998 Page 3
1. PRE-INSTALLATION CHECKS AND SAFETY PROCEDURES
UNPACKING
Check Packaging - Upon taking delivery of the unit, inspect the packaging for signs of damage. If damage
has occurred, advise the carriers and/or the suppliers immediately.
Check Contents - Upon taking delivery of the unit, unpack the unit carefully and check that all the items are
present and correct. If any items are missing or damaged, contact your equipment dealer.
Retain Packaging - The shipping carton is the safest container in which to transport the unit. Retain
undamaged packaging for possible future use.
IMPORTANT SAFETY PRECAUTIONS
Read Instructions - All relevant safety, installation and operating instructions should be read before
attempting to install, connect or operate the unit.
Retain Instructions - All safety, installation and operating instructions should be retained for future
reference.
Heed Warnings - All warnings on the unit and in any relevant safety, installation or operating instructions
should be adhered to.
Cleaning - Unplug the unit from the power outlet before cleaning. Do not use liquid cleaners or aerosol
cleaners. Use a damp cloth for cleaning.
Attachments - Do not use attachments not recommended by the product manufacturer as they may cause
hazards.
Water and Moisture - Do not expose the internal electronics of this unit to water or dampness; for example,
in an unprotected outdoor installation, or in any area classified as a wet location.
Accessories - Do not attach this unit to an unstable stand, bracket or mount. The unit may fall, causing
serious injury to a person and serious damage to the unit.
Power Sources - This unit should be operated only from the type of power source indicated on the
manufacturer’s label. If you are not sure of the type of power supply you intend to use, consult your
equipment dealer or local power company. For units intended to operate from battery power or other sources,
refer to operating instructions.
Power Cord Protection - Power supply cords should be routed so that they are not likely to be trapped,
pinched or otherwise damaged by items in close proximity to them, whether inside the unit or outside it.
Particular attention should be paid to cords at plugs, connection units and the point of exit from the unit.
Overloading - Do not overload outlets and extension cords, as this can result in fire or electric shock.
Object and Liquid Entry - Never push objects of any kind into the unit, as they may touch dangerous
voltage points or short out parts that could result in fire or electric shock. Never spill liquid of any kind on or
inside the unit.
Servicing - Servicing of the unit should only be undertaken by qualified service personnel, as opening or
removing covers may expose you to dangerous voltages or other hazards.

EX-4 Tx1000 Keypad Expander Installation Manual Revision 1.0 March 1998 Page 4
Damage Requiring Service - Servicing by qualified personnel should be carried out under the following
conditions:
(a) If liquid has been spilled, or objects have fallen into, the unit;
(b) If the internal electronics of the unit have been exposed to rain or water;
(c) If the unit does not operate normally by following the operating instructions.
(d) If the unit has been dropped or the enclosure is damaged;
(e) If the unit exhibits a distinct change in performance. This indicates a need for service.
Replacement Parts - If replacement parts are required, ensure that only replacement parts recommended by
the product manufacturer are used.
Safety Check - Upon completion of any service or repairs to the unit, safety checks should be performed to
ensure that the unit is in proper operating condition.
Pre-installation Checks - It is recommended that the unit be bench-tested prior to installation on the site.
Adhere to Safety Standards - All normal safety precautions as laid down by British Standards and the
Health and Safety at Work Act should be observed.
WARNING
TO PREVENT DANGER OF FIRE OR SHOCK, DO NOT EXPOSE THE INTERNAL COMPONENTS OF
THIS EQUIPMENT TO RAIN OR MOISTURE.
The “exclamation point” symbol inside an equilateral triangle is used to alert the user of this equipment to
important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
EQUIPMENT CONTENTS.
1EX-4 Expander
4RS232 cables, EX-4 to Tx1000 Base Unit
1Installation Manual

EX-4 Tx1000 Keypad Expander Installation Manual Revision 1.0 March 1998 Page 5
2. INTRODUCTION
GENERAL
The EX-4 Keypad Expander is designed to allow a single Tx1000 keyboard to control up to four Tx1000 base
units. 64 Cameras can be selected and controlled when all four base units are connected.
The EX-4 is supplied in a 19" rack mountable enclosure.
EX-4 TECHNICAL SPECIFICATION
Power Requirements: 12V dc
Current Consumption: <100mA @ 12V
Control functions: •Base unit selection using '#' and '1' - '4' keys
Features: •4 x RS232 Serial output to Tx1000 base units.
•4 x Video Inputs from Tx1000 base units
•1 x RS232 Serial Input from Tx1000 keypad.
•1 x Video Output to Tx1000 keypad/monitor.
Engineering Facilities: •Powered from base unit 1.
•LEDs indicating selected base unit and power present.
•Standard DB9 connectors.
Video Input: 1v p-p 75Ωterminated input via BNC socket.
Video Output: 1v p-p 75Ωimpedance via BNC socket.
Dimensions (external): 483 x 135 x 30mm. Metal case poweder coated RAL7035.
Weight: 1.0Kg
Temperature range: -10° Celsius to +40° Celsius

EX-4 Tx1000 Keypad Expander Installation Manual Revision 1.0 March 1998 Page 6
3. INSTALLATION
All necessary cables are provided with each EX-4 to connect to four base units as shown below. Each base
unit requires a RS232 connection to it's keypad connector and also coax from monitor output to EX-4.
Base unit number 1 supplies power for the EX-4, to maintain a low resistance path do not extend this RS232
cable. The other RS232 cables can be extended up to 50M. Should a greater distance be require, then a
TxLD can be used to allow operation 500M between EX-4 and base unit.
Fig 1. EX-4 connections
Each base unit has a corresponding LED which flashes on key presses to indicate the selected base unit. The
flash rate is fixed at the keypad baud rate causing the LEDs to not reach full brightness. Simply shield the
LEDs from ambient light if required.
The Power LED is illuminated indicating power is present.

EX-4 Tx1000 Keypad Expander Installation Manual Revision 1.0 March 1998 Page 7
4. OPERATION
Operation is transparent. Each base unit is selected using the following key presses:
Press and HOLD '#'
Tap '1 - 4'(Base unit 1 - 4)
Release '#'
Further key presses will pass to this base unit as normal. To aid with identification of selected base unit and
camera, the camera number is prefixed with 'A' - 'D' representing selected base unit.
Example:
Assume that four Tx1000/16 base units are connected to the EX-4.
To select camera 19, Camera 3 of base unit 2 use the following key presses.
Press and HOLD '#'Select
Tap '2'2nd
Release '#'base unit
Tap '3'then camera 3

EX-4 Tx1000 Keypad Expander Installation Manual Revision 1.0 March 1998 Page 8
5. EXAMPLE SYSTEM DIAGRAMS
Each example assumes that both RS232 and video are connected between each base unit and the EX-4.
Building Block Video Ltd. Tx1000/64 single control + 4 spot monitors.
Unit 1 Avocet Way, Diplocks Industrial Estate, Hailsham, East Sussex, UK. BN27 3JF. Tel: +44 (0)1323 842727 Fax: +44 (0)1323 842728
Camera 1 Camera 16 Camera 17 Camera 32 Camera 33 Camera 48 Camera 49 Camera 64
Control Monitor.
Cameras 1-64 EX-4
Tx1000/16 Tx1000/16 Tx1000/16 Tx1000/16
B B V300
LENS
LENS
IRIS FOCUS ZOOM
PROGRAM #AUTOPAN
9 10 11 12 13 14 15 16
875 6431 2
CAMERA SELECT
MONITOR
PAN +TILT
PRESETPATROLSEQ
B B V
1000
Spot monitor.
Cameras 1-16 Spot monitor.
Cameras 17-32 Spot monitor.
Cameras 33-48 Spot monitor.
Cameras 49-64
Tx1000 Keyboard
Building Block Video Ltd. Tx1000/64 multiple sites with master control.
Unit1AvocetWay,DiplocksIndustrialEstate,Hailsham,EastSussex,UK.BN273JF.Tel:+44(0)1323842727 Fax:+44(0)1323842728
Camera 1 Camera 16 Camera 1 Camera 16 Camera 1 Camera 16 Camera 1 Camera 16
Tx1000/16 Tx1000/16 Tx1000/16 Tx1000/16
Control of all site
cameras
EX-4
B B V300
LENS
LENS
IRIS FOCUS ZOOM
PROGRAM #AUTOPAN
9 10 11 12 13 14 15 16
875 6431 2
CAMERA SELECT
MONITOR
PAN +TILT
PRESETPATROLSEQ
B B V
1000
B B V300
LENS
LENS
IRIS FOCUS ZOOM
PROGRAM #AUTOPAN
9 10 11 12 13 14 15 16
875 6431 2
CAMERA SELECT
MONITOR
PAN +TILT
PRESETPATROLSEQ
B B V
1000
B B V300
LENS
LENS
IRIS FOCUS ZOOM
PROGRAM #AUTOPAN
9 10 11 12 13 14 15 16
875 6431 2
CAMERA SELECT
MONITOR
PAN +TILT
PRESETPATROLSEQ
B B V
1000
BBV300
LENS
LENS
IRIS FOCUS ZOOM
PROGRAM #AUTOPAN
9 10 11 12 13 14 15 16
875 6431 2
CAMERA SELECT
MONITOR
PAN +TILT
PRESETPATROLSEQ
B B V
1000
B B V300
LENS
LENS
IRIS FOCUS ZOOM
PROGRAM #AUTOPAN
9 10 11 12 13 14 15 16
875 6431 2
CAMERA SELECT
MONITOR
PAN +TILT
PRESETPATROLSEQ
BBV
1000
Local independant control of site
cameras.
Central control of all remote
sites.
Site 1 Site 2 Site 3 Site 4
Table of contents
Other BBV Extender manuals
Popular Extender manuals by other brands

CEL-FI
CEL-FI QUATRA 4000 user manual

D-Link
D-Link DHP-W311AV Technical specifications

Grandbeing
Grandbeing EX0101-U32/U33 operating instructions

Linkskey
Linkskey LKV-IPM01 supplementary guide

Winegard
Winegard ConnecT 2.0 quick start guide

Net to Net Technologies
Net to Net Technologies ENE3400-P installation instructions