Beta Three BA3240 User manual

BA3240
RR
User sM anual
ED-B3-MA-050530-001

Please read the user manual carefully before using BA-3240,and operate according
to the user manual strictly.Any questions, please ask for the local distributor.
P3
P3
P4
P5
P5
P6
P7
P9
P9
P10
DEAR CUSTOMERS:
CONTENTS
1
2
3
4
5
6
7
8
9
10
Attentions
Functions&features
Parameters
Front panel
Back panel
Power supply
Function setup and cable connection
Operations
Protection functions
Troubles and trouble shootings

1ATTENTIONS
3
2FUNCTIONS&FEATURES
Do not open the cover because exist dangerous voltage,please ask the professional to repair
Do not expose it to the raining or moisture
Do not put it under the direct sunshine,high temperature or heat source
Keep good ventilation,not stop the ventilating hole
Note the local voltage must matched with the voltage required
Please put off the plug if not use for a long time
Connect with right load, not work under overload for a long time
Do not let the obstacle into the unit, keep the unit away the obstacles
Please stop using if the cable is damaged
The equilateral triangle with lightning bolt warns the user of dangerous voltage levels
localized within the cabinet.
The equilateral triangle with exclamatory mark means the important operation on the
user's manual.
Symbols:
BA-3240 is a integrated amplifier with completed functions,can meet the demand
of small public address system separately.
1.> Five channels input
INPUT1-INPUT4 can be choosed to be balanced microphone input with low impedance,
built-in 24V eidolon power microphone input or line balance input with high impedance.
INPUT5 is unbalanced line input with high impedance,INPUT1 is fault channel,can control
other channel output
2.> Balanced rated voltage output with 120V 100V 75V 50V 25V, 4 Ohms rated
impedance output and 8 /1W monitor output are optional
3.> Can external connect equipments
4.> Separately volume control for each channels,the total volume control is also available
and convenient
5.> HF/LF adjust
6.> Seven sections LED indicators
7.> Separated areas with Six channels
8.> The DC 24V interface is available under the urgent situation to provide the power supply
when the local voltage has problems
9.> Power supply is optional for 110V/220V
10.> Auto power off function under Output short circuit,over loading, overheat protection

3
4
PARAMETERS
BA3240
240W
50Hz-16KHz
8 /1W monitor 4-16 rated impedance
25V 50V 75V 100V 125Vrated voltage
10mV/1K Balanced
200mV/30K Balanced
200mV/50K Unbalanced
<0.5% @1KHz 24W
>70dB
>80dB
1V/1K
> 6dB @100Hz
> 6dB @10KHz
>36 dB
99V-121V AC 50/60Hz
198V-242V AC 50/60Hz
316 88 250mm
15.6Kg
16.4Kg
MODEL
THD<1% RMS
Frequency response +0/-3dB
Output terminal
INPUT SENSITIVITY/IMPEDANCE
INPUT1-INPUT4 microphone input
INPUT1-INPUT4 line input
INPUT5 input
THD
S/N RATIO: (A-WEIGHT)
Microphone
Line
REC OUT/impedance
TONE CONTROL
LF
HF
Mute
Power supple1
Power supply 2
Dimensions(W*H*D)
Net weight
Gross weight

4FRONT PANEL
5BACK PANEL
5
321
456
INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 BASS TREBLE VOLUME 6 ZONE
-30 -18
-24 -12 0
-6-36
POWER
(dB)
OUTPUT LEVEL
0000
0 10 0 10 0 10
0 10 0 10 0 10 +10dB-10dB +10dB-10dB
POWER
PRO Public Address Amplifier BA3240
Beta Three
2 3 4 5 6 7
8 9 10 11 12 13
1 Signal indicator for input 1
2 Signal indicator for input 2
3 Signal indicator for input 3
4 Signal indicator for input 4
5 Signal indicator for input 5
6 ON/OFF indicator for area 1~6
7 Output level indication
8 Volume control for channel 1 5
9 LF Adjust
10 HF Adjust
11 Total volume control
12 Channel switch for area 1 6
13 Power
1 110 / 220V Power Switch
2 Distribution zone output terminal
3 Recording output terminal
4 Channel 5 input
5 Channel 4 input
6 Channel 34 input
7 Channel 2 input
8 Channel 1 input
9 Power supply
10 Power amplifier output clip
11 Distribution terminal clip
12 24V/10A DC voltage
13 Insert terminal
14 Channl input 4 terminal
15 Channl input 3 terminal
16 Channl input 2 terminal
17 Channl input 1 terminal
VOLTAGE SELECTOR
~110V/~220V
50-60Hz
POWER
ZONE
INPUT POWER
STANDBY
RMS 240W POWER OUTPUT
COM 425V 50V 70V 100V 120V
8/1W
MONITOR 24V/15A
0V
L
R R
L
INPUT 5
REC OUT AUX IN
INSERT
INPUT 1INPUT 2INPUT 3INPUT 4
CHANNELS
LINE
24V PHANTOM
MIC
LINE
24V PHANTOM
MIC
LINE
24V PHANTOM
MIC
LINE
24V PHANTOM
MIC
Elder Audio Manufacture Co., Ltd
CH1 CH2 CH4CH3 CH5 CH6
·ÖÇøÊäÈë
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
!
240VA
ZONE OUTPUT
2 3 4 5 6 7 8
910 11 12 13 14 15 16 17

6POWER SUPPLY
6
Please ensure that the back voltage showing is according with the local voltage
This unit have voltage selector, can be used for different voltage
Before operation, please chck the local voltage is optional for the 110/220V selector voltage,
you can connect it if correct and optional. If not optional, please put the selector to the correct
voltage value, please note cut off the power supply when select.
The operation as:
230V
THIS IS OPTIONAL FOR 220V
115V
THIS IS OPTIONAL FOR 110V
Be sure that the power input socket is good, power cable is not damaged when
connecting, Please power off when not using unit.
The normal working voltage is 250VA, the peak power cost about 600VA.
When selected to 220V, please use 2.5A 5*20mm delay style fuse
When selected to 110V, please use 5A 5*20mm delay style fuse
Please use the correct fuse when voltage power changed
Note that the voltage will be put to 220 when leaving factory
Note:

7
7
FUNCTION SETUP AND CABLE CONNECTION
1> Unit connecting
2> input plug connecting
Zone1
Zone2
Zone 3
Signal For example Mic/ cd/NL4/receiver)
Mic 1
Line output recoring or amplifier supplying power
Insert equipment
Power output to zone
distribution(note correct voltage
Monitor speaker Storage
SIGNAL
SIGNAL
GROUND
SIGNAL
12
3
INPUT1-INPUT4 is unbalanced input, as left connecting
12
3
INPUT1-INPUT4 is balanced connecting, as left connecting
Channel input1 is priority channel, should be inserted urgency microphone or
fire fighting signal.
Zone 4
Zone 5
Zone 6
Note:
SIGNAL
SIGNAL
GROUND
SIGNAL
VOLTAGE SELECTOR
~110V/~220V
50-60Hz
POWER
ZONE
INPUT POWER
STANDBY
RMS 240W POWER OUTPUT
COM 425V 50V 70V 100V 120V
8/1W
MONITOR 24V/15A
0V
L
R R
L
INPUT 5
REC OUT AUX IN
INSERT
INPUT 1INPUT 2INPUT 3INPUT 4
CHANNELS
LINE
24V PHANTOM
MIC
LINE
24V PHANTOM
MIC
LINE
24V PHANTOM
MIC
LINE
24V PHANTOM
MIC
Elder Audio Manufacture Co., Ltd
CH1 CH2 CH4CH3 CH5 CH6
·ÖÇøÊäÈë
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
!
240VA
ZONE OUTPUT

8
3> input sensitivity:
You should know the signal character before connecting,
then connect to this unit correct channel.
LINE
24V PHANTOM
MIC
LINE
24V PHANTOM
MIC
LINE
24V PHANTOM
MIC
A B C
A indicates that the channel is set to 24V phantasm microphone input, the input
sensitivity is 10mV
B indicates that the channel is set to microphone input, the input sensitivity is 10mV
C indicates that the channel is set to line input, the input sensitivity is 200mV
4> Insert equipment connecting
Line input
Line output Signal Ground
Insert equipment
Connected equipment can be selected based on your need,
please connect as above drawing
5> Zone distribution connecting
Connect correct output voltage to the zone terminal based on your needs
6> Output connecting
Please select correct voltage of broadcast to connect with relative interface of the BA3240
Can connect many loudspeaker in parallel connection.But the total power can not be over 240W
7FUNCTION SETUP AND CABLE CONNECTION

8
9
9
OPERATIONS
1 Start
a set the right function and connect the right cable
b check the output line and see if it is short circuit or loading is too low
c check the local voltage is same as the require of power
d adjust the volume to Min
e connect the power supply,then open the sound source,pre and effect equipments,
must sure all equipments work well
f Open the power supply,and sure the indicator is lit up
g Adjust the volume to right place clockwise
2 Put off
a adjust volume to Min. counter-clockwise
b put off the power supply,and sure the indicator off
c put off the pre and effect equipments and sound source equipment
PLEASE OBEY THE FOLLOWING:
3 Volume adjust
Connect the input signal and open the sound source,adjust the volume,if the indicator
is not lit up,please check the sound source.Adjust according to the voltage output and
the signal.When 0dB output voltage is lit up,the output is RMS, if is too much,will cause
the distortion
4 Area setting
Six buttons and six yellow indicators, when the six indicators are lit up, it means that
there are output in six areas,press the area button, the relative area will be closed and
the indicators will be off
BA-3240 Completed functions give the amplifier and speaker a good protection to avoid
the damage, like short circuit,overloading,and overheat.
1 Circuit protect:
2 Cverload protect:
3 Overheat protection:
If the unit will be back to required range,the nuit will be back to home
PROTECTION FUNCTIONS
when exist the short circuit,it will be off automatically
it will be off automatically when input impedance is too low
if the temperature heatsink is over the standard degree.

10
10
TROUBLES AND TROUBLE SHOOTINGS
If it does not work according to the above steps,please ask for the professional to repair.
No sound,and the
indicator is not lit up
No sound, the power
indicator is lit up,
And signal indicat
or is not lit up
Overload indicator
is too right.the
sound is not good
Signal indicator is
normal,no output
Fuse damaged
Others
Check power plug connection
Check the voltage 220V/110V
Check the fuse
Check the input signal
If open the power supply and adjust the volume
Check the volume electroform
Check the sensitivity setting
The output is too big or not
Check the output connecting,
Check The loading
Check the local voltage
Check the fuse specification
Check if the setup and connection are accordant with
the user manual
Ask for the distributor
Solutions
Status
1
2
3
1
2
3
1
2
1
1
2
1
2
Check the volume is too big or not
3

BA3240
RRUser sM anual
Table of contents
Other Beta Three Amplifier manuals

Beta Three
Beta Three DT Series User manual