Blueair BBB23 - 1S User manual

Installation & Operation Manual
Glass Door Countertop Refrigerator
Please read this manual completely before installing or operating this unit!
BBB23 - 1B / 1S
BBB59 - 2B / 2S
BBB69 - 3B / 3S
BBB90
-
4B / 4S
BBB90
-
4B
/
4S
BBB23 - 1BG / 1SG
BBB59 - 2BG / 2SG
BBB69
3BG/3SG
BBB69
-
3BG
/
3SG
BBB90 - 4BG / 4SG
BDD23
-
1B / 1
S
Blue Air reserves the right to make product modification at any time. Specifications and Designs are subject to change without notice.
BDD59 - 2B / 2S
BDD69 - 3B / 3S
BDD90 - 4B / 4S
IMPORTANT SAFETY INSTRUCTION ( SAVE THESE INSTRUCTIONS )
Visit our website at www.blueairinc.com

Contents
♦Specifications ……………………………….............................
♦Installation ……………………………………………………….
3
4
♦Maintenance & Cleaning ………………………………………
♦Operation & Caution “ Important” ………………………….
♦Air Hose & Tower Installation Schematic Diagram………..
4
5
6
♦Beer Line & CO₂Line Installation Schematic Diagram…..
♦Troubleshooting ……………………………..............................
7
8
Blue Air Refrigeration has a Nationwide Service Network
to provide timely services for our customer’s needs.
Please call or fax us to the following numbers.
Service Contact
Please
call
or
fax
us
to
the
following
numbers.
Blue Air Refrigeration Nationwide Service Network
Toll Free, 1-866-677-8500
TEL, (310) 808-0102
Fax, (310) 808-0242/0262
2

Specifications
Product Back Ba
r
Model BBB23-1B/1S BBB59-2B/2S BBB69-3B/3S BBB90-4B/4S
BBB23-1BG/1SG BBB59-2BG/2SG BBB69-3BG/3SG BBB90-4BG/4SG
Capacity (cu.ft) 7 19 23 31.5
Exterior Dimensions [IN]
(1B/1S - Including 4" Casters)
W 23 2/5 59 69 90 1/3
D 29 1/2 27 1/9 27 1/9 27 1/9
H
39 1/4
37
37
37
H
39
1/4
37
37
37
Net Weight (lbs) Solid/Glass Door 187/198 276/298 298/320 441/474
Rated Voltage AC115V /60Hz
Amps 3.3 A 6.3 A 6.3 A 6.3 A
Compressor (HP) 1/5 HP 3/8 HP 3/8 HP 3/8 HP
Type of Power Cord NEMA 5-15
Shelves 2EA 4EA 4EA 6EA
Number of Doors 1 2 2 3
Refrigerant R-134a
Range of Temperature 32~40°F
Product Direct Draw Beer Dispenser
Model BDD23-1B/1S BDD59-2B/2S BDD69-3B/3S BDD90-4B/4S
Capacity (cu.ft) 7 19 23 31.5
Exterior Dimensions [IN]
(1B/1S - Including 4" Casters)
(Except Height Tower)
W 23 2/5 59 69 90 1/3
D 29 1/2 27 1/9 27 1/9 27 1/9
H 39 1/4 37 37 37
Net Weight (lbs) 187 276 298 441
Rated Voltage AC115V /60Hz
A
33A
63A
63A
63A
A
mps
3
.
3
A
6
.
3
A
6
.
3
A
6
.
3
A
Compressor (HP) 1/5 HP 3/8 HP 3/8 HP 3/8 HP
Type of Power Cord NEMA 5-15
1/2 Barrels 1EA 2EA 3EA 4EA
Number of Doors 1 2 2 3
Refrigerant R-134a
Ran
g
e of Tem
p
erature 32~40°F
3
♦Specifications and Designs are subject to change without notice.
♦The name plate (including Serial No.) is located on the upper left side of the cabinet interior.
gp

Installation
1. INDOOR USE ONLY
• This unit is intended for indoor use only.
2. LOCATION
• Be sure that the location is strong enough to support the total weights of the unit and its contents.
• Keep the unit away from sunlight and other heat generating equipment.
• The minimum clearance between the back of the unit and the wall should be at least 7 inches.
3. INSTALLING CASTORS
• Ensure that castors with brake are installed in front.
4. LEVEL
• The unit should be level to provide adequate drainage.
5. ELECTRICAL CONNECTION
• The unit should be plugged into a 115V/60Hz, grounded wall receptacle to prevent
electrical shock and fire hazards.
• Do not plug other electrical units into same wall receptacle this unit is plugged into.
• Do not use an extension cord.
• Compressor warranties are void if the compressor burns out due to low voltage.
6. INSTALLING SHELF
• Install shelves using shelf-clips provided.
Maintenance & Cleaning
1T iti fi ti f th d fi h ldb
1
.
T
o ma
i
n
t
a
i
n proper re
f
r
i
gera
ti
on per
f
ormance,
th
e con
d
enser
fi
ns s
h
ou
ld
b
e
checked monthly and cleaned with a soft brush or vacuum cleaner as needed.
2. Wait at least 6 minutes after unplugging the unit before replugging it in.
3. The interior and exterior of the unit can be cleaned with mild detergent and water.
• Do not use abrasive cleaners to avoid scratching the unit.
4
4. The door-gasket should be cleaned to maintain proper seal.

Operation
1. The temperature controller (thermostat) is located on
the upper left of the back side of the cabinet interior.
2. The controller has been preset to the "NORMAL" position
at the factory.
3. Set the control-knob toward "COOL" for higher temperature
d"COLD" f l t t
an
d
"COLD"
f
or
l
ower
t
empera
t
ure.
4. The thermostat controls compressor's ON/OFF by sensing
the inside temperatures of cabinet.
5. The unit is equipped with an off-cycle defrost
Caution “Important
”
5
※Excessively opening the door will cause malfunction.
※Handle with care when shutting the door.

Air Hose & Tower Installation Schematic Diagram
** This guide is for Direct Draw Beer Dispenser only.
3” Dia. Beer Column
Hook for hanging air hose
6

Beer Line & CO
₂
Line Installation Guide
** This guide is for Direct Draw Beer Dispenser only.
7
※Install Beer Line & CO₂Line as shown above.

Troubleshooting
Problem Possible Cause Action
Compressor
ill
Power connection failure. Check Power Cord and plug it in.
w
ill
not start
Power switch is in off position. Switch it to on position.
Temperature set is too high. Set the Dial of thermostat at
Colder
The unit does not
refrigerate well
The door is opened too frequently. Do not open the door frequently.
Stocking of too much, warm,
or moist product.
Ensure the product is covered
and at room temperature before
stocking the product.
Not
enough ventilation
Move the unit in a well ventilated
area
with at least
7inches
Not
enough
ventilation
.
area
with
at
least
7
inches
of clearance on all sides.
Condenser is clogged. Clean the condensor
Condensation
on cabinet exterior
High moisture air can produce
dews
during the rainy season.
Wipe with cloth.
on
cabinet
exterior
dews
during
the
rainy
season.
※The following is not an indication of problem or malfunction.
A water-flowing sound can be heard when the unit is operating.
This is the sound of refrigerant is flowing.
8

WARRANTY CERTIFICATE
Warranty Valid Only In the USA
This warranty is subject to all of the terms and conditions listed below. Warranty card furnished with this unit must be
properly executed and returned to BLUE AIR immediately after installation. Failure to return the warranty registration
card to provided location will automaticall
y
void all warranties.
1 Year Parts and Labor Warranty:
BLUE AIR warrants to the original purchaser the BLUE AIR unit sold and all parts thereof to be free from defects in
material or workmanship, under normal use and service for a period of one(1) years from the date of sale or fifteen (15)
months from date of shipment by us, whichever occurs first. Unit lamps are NOT included in the warranty. Our obligation
under this warranty shall be limited to repairing or replacing F.O.B. factory any of such products that prove to be
defective and which our examination shall disclose to our satisfaction to be defective.
A) Any part returned to the company under the terms of this warranty must be accompanied by the record of the
cabinet
model
number
serial
number
return
authorization
number
and
such
return
shall
be
on
the
basis
of
cabinet
model
number
,
serial
number
,
return
authorization
number
and
such
return
shall
be
on
the
basis
of
TRANSPORTAION CHARGES PREPAID.
B) Improper operation due to low voltage condition, inadequate wiring and accident damages are not manufacturing
defects and are strictly the responsibility of the purchaser.
C) Condenser coils must be cleaned at regular intervals. Failure to do so may cause the compressor to malfunction
and will void the warranty. This contract does not apply outside the limits of the U.S.A. nor does it to any part
which has been subject of misuse, neglect, alteration, accident or to any damage caused by transportation, flood,
fire, or the acts of God. This contract is not effective unless the BLUE AIR Warranty Card, furnished with each
unit, is properly filled out and mailed back to BLUE AIR within twelve (12) days from the date of installation. The
t
“O i i l
Ph ”
d
hi
hll
b
dd
t
f
t
th t
fi
iti
t
erm
“O
r
i
g
i
na
l
P
urc
h
aser
”
as use
d
h
ere
i
ns
h
a
ll
b
e
d
eeme
d
t
ore
f
e
r
t
o
th
a
t
person,
fi
rm, assoc
i
a
ti
on, o
r
company
for whom the refrigeration unit refers to herein is originally installed.
Warranty Claims
All labor claims or parts must include copy of original invoice submitted directly to Blue Air. All claims must included: a
copy of original invoice (Customer Name, address, model name, and Date of Sale) Customer Name, Phone Number,
Model & Serial No of unit, date of sale, Distributors name and brief description of complaint. On all compressor
warranties the compressor model tag must be returned to Blue Air along with the above information. All claims must be
reported to Blue Air within one (1) year of occurrence. All compressors have an additional four (4) years warranty
coverage. This warranty will not be effective unless the warranty card is returned or registered (www.blueairinc.com)to
Bl
Ai
ithi
12
d
f
itllti
Cfi
it
f
t
it ti
b
tti
Bl
Ai
di tl
(
1
866
677
Bl
ue
Air
w
ithi
n
12
d
ays o
f
i
ns
t
a
ll
a
ti
on.
C
on
fi
rm rece
i
p
t
o
f
warran
ty
reg
i
s
t
ra
ti
on
by
con
t
ac
ti
ng
Bl
ue
Air
di
rec
tly
(
1
-
866
-
677
-
8500)
Non Warranty Claims
Blue Air’s warranty service is limited to labor of repairing merchandise and/or parts replaced. This warranty does not
authorize any person(s) to assume any obligation or liability other than what the warranty permits. This warranty will be
void if such action occurs. Any attempt to repair BLUE AIR products without an official job number issued by BLUE AIR
will not be covered by warranty and the services will not be compensated. This warranty does not apply to any part,
which has been subject to misuse, neglect, alteration, accident, or to any visible or concealed damage caused by
transportation, flood, fire, acts of God, etc.
Concealed Damage Example
Styrofoam may hide any hidden dents on the shipment that may not be completely visible. You must inspect all corners
and grills thoroughly. If the carrier stacks any contents on the units this can cause glass on the glass door units to break
from the inside. All units are checked for any damages before they are released.
Additional Four-Year Compressor Warranty (Additional Up to 4 years)
In addition to the warranty above, BLUE AIR warrants the hermetically sealed compressor for an additional four (4)
years for the GLASS DOOR REACH-INS, & CHEST FREEZERS/COOLERS. Not to exceed sixty (60) months from the
date of shipment from our warehouse, provided upon receipt of the compressor manufacturer examination shows the
sealed compressor to be defective. Lack of maintenance will result in a voided warranty. This extended warranty does
not apply for any electrical controls, accumulator or wiring harnesses which are covered by the standard warranty.
9

NO CLAIMS CAN BE MADE AGAINST THIS WARRANTY FOR LOST PRODUCT.
What Is Not Covered By This Warranty
Spoilage of Product - No claims can be made against this warranty for any spoilage of products, such as food, loss of
sales, or consequential damages. BLUE AIR is not responsible for the repair or replacement of any parts that BLUE AIR
determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accidents, damage
durin
g
transit o
r
installation
,
fire
,
flood
,
o
r
acts of God.
g
,
,
,
Warranty Is Non Transferable - This warranty is not assignable and applies only to the original purchaser/user to
whom delivered. Any such assignment or transfer will void this warranty and all other warranties implied.
Improper Usage - BLUEAIR is not liable in any way for parts or labor coverage for component failure or other damages
resulting from improper usage or installation or failure to clean and/or maintain product as mentioned in the warranty
packet provided with the unit.
Outside U.S. (Including Alaska) - This warranty does not apply to, and BLUE AIR is not responsible for, any warranty
claims made on products sold or used outside the United States.
Improper Electrical Connections -BLUE AIR is not responsible for the repair or replacement of failed or damaged
components resulting from electrical power failure, the use of extension cords, low voltage, or voltage interference to the
it
un
it
.
No Implied Warranty of Merchantability or Fitness for a Particular Purpose - There are no other warranties,
expressed, implied or statutory, except the one (1) year parts and labor warranty and the additional four (4) years
compressor warranty as described above. These warranties are exclusive and in lieu of all other warranties, including
implied warranty and merchantability or fitness for a particular purpose. There are no warranties, which extend beyond
this mentioned description.
Remote Condensers - BLUE AIR warrants the original purchaser of the remote cabinet one year parts and labor
coverage for all cabinet parts thereof to be free from defects in material or workmanship, under proper use and
maintenance service, as specified by BLUE AIR. This warranty is limited to the cabinet only. BLUE AIR it not liable for
remote condensin
g
units.
g

Warranty Registration Card
Customer Name
B
usiness
N
ame
Blue Air Commercial Refrigeration Inc.
223 W. Rosecrans Ave, Gardena, CA 90248
Tel, 310-808-0102, Fax, 310-808-0242
Telephone : ( ) Telephone : ( )
Address (Customer) Address (Business or Installation Site)
Place of Purchase
Date Purchased
Date Installed
Street
City State Zip
Street
City State Zip
Place
of
Purchase
Date
Purchased
Date
Installed
Model Name Product Serial No.
ExtendedWarrantyOption
Additional 1 Year Parts & Labor extended Warranty available
Please make check payable to Blue Air and return with this registration Card.
□Yes, I would like the extended warrant
y
. / □No, I would not like the extended warrant
y
.
Cutalongdottedlineandmail it back to; BLUE AIR Customer Service Dept. 223 W. Rosecrans Ave, Gardena, CA 90248
y
y
Signature of Business Owner Date
※
The Warranty becomes void if the attached warranty card is not filled out and returned to Blue Air within 15 days from the purchase date.
※
The Warranty becomes void if the attached warranty card is not filled out
and returned to Blue Air within 15 days from the purchase date.
Cut along dotted line and mail it back to ;
BLUE AIR Customer Service Dept
BLUE
AIR
Customer
Service
Dept
.
223 W. Rosecrans Ave, Gardena, CA 90248
11

223 W. Rosecrans Ave, Gardena, CA 90248
Toll Free
,
1-866-677-8500
BLUE AIR
,
TEL, (310) 808-0102
Fax, (310) 808-0242/0262
Visit our website at www.blueairinc.com
This manual suits for next models
47
Table of contents
Other Blueair Refrigerator manuals