Blueair BACB53 User manual

Please read this manual completely before installing or operating this unit!
BACB53
BACB71
BACB53M
BACB71M
BACB71
BACB74
BACB83
BACB86
BACB96
BACB71M
BACB74M
BACB83M
BACB86M
BACB96M
Blue Air reserves the right to make product modification at any time. Specifications and Designs are subject to change without notice.
IMPORTANT SAFETY INSTRUCTION ( SAVE THESE INSTRUCTIONS )
Visit our website at www.blueairinc.com
Installation & Operation Manual
Chef Base

Contents
♦Specifications ………………………………....
♦
Itllti
3
♦
I
ns
t
a
ll
a
ti
on …………………………………….
♦Maintenance & cleaning ……………………..
♦Operation ……………………………………...
♦Trouble-Shootin
g
……………………………..
4
4
5
6
g
♦Installing Castors ..…………………………..
6
7
Service Contact
Blue Air Refrigeration has a Nationwide Service Network
to provide timely services to our customer’s needs.
Please call or fax us at the following numbers.
Blue Air Refrigeration Nationwide Service Network
Toll Free, 1-866-677-8500
TEL, (310) 808-0102
Fax (310) 808
-
0242/0262
Fax
,
(310)
808
-
0242/0262
2

Specifications
Product Chef Bases
Model BACB53(M) BACB71(M) BACB74(M) BACB83(M) BACB86(M) BACB96(M)
Capacity (cu.ft) 9.8 14.3 14.3 17.2 17.2 21.4
W 52 3/4 70 1/2 73 1/16 83 1/2 86 1/2 96
Exterior Dimensions
(Including 4”Casters)
[in]
D 32 1/4 32 1/4 32 1/4 32 1/4 32 1/4 32 1/4
H 25 1/2 25 1/2 25 1/2 25 1/2 25 1/2 25 1/2
Net Weight (lbs) 236 298 304 342 348 364
Type
of
refrigeration
Idi li (F bl i )
Type of refrigeration
system
I
n
di
rect coo
li
ng
(F
an
bl
ow
i
ng
)
Control Thermostat Control
Drawers 244444
Rated Voltage AC115V /60Hz
Type of Power Cord NEMA 5-15
Amps 2.5 3.2 3.2 3.9 3.9 3.9
Compressor (HP) 1/5 HP 1/5 HP 1/5 HP 3/8 HP 3/8 HP 3/8 HP
Refri
g
erant R-134a
g
Range of Temperature 32~40°F
♦Models that has “M” on last digit of the Model Name have “V” shape of Top
♦
Specifications and Designs are subject to change without notice
♦
Specifications
and
Designs
are
subject
to
change
without
notice
.
♦The name plate (including Serial No.) is located on the upper left side of the cabinet interior.
3

Installation
Installation
1. INDOOR USE ONLY
1) This unit is intended for indoor use only.
2. FOR LOCATION
1
)
Be sure that the location is stron
g
enou
g
h to su
pp
ort the total wei
g
hts of the unit and the
)ggppg
content.
2) Keep the unit away from sunlight and other heat generating equipment.
3) The minimum clearance between the back of the unit and the wall should be 7 inches at least.
3. INSTALLING CASTORS
1) Be sure that castors with brake should be installed in front.
4 LEVELING
4
.
LEVELING
1) The unit should be leveled to provide adequate drainage.
5. ELECTRICAL CONNECTION
1) The unit should be plugged into a 115V/60Hz, grounded wall receptacle to
prevent electrical shock and fire hazards.
2) Do not plug other electrical units into same wall receptacle this unit is plugged into.
3) Do not use an extension cord.
Maintenance & Cleaning
3)
Do
not
use
an
extension
cord.
4) Compressor warranties are void if the compressor burns out due to low voltage.
Maintenance & Cleaning
1. To maintain proper refrigeration performance , the condenser fins should be
checked monthly and clean with a soft brush or vacuum cleaner as needed.
2. Wait at least 6mimutes after unplugging the unit before plugging in.
3Thiti d ti fth it b l d i l i i t
3
.
Th
e
i
n
t
er
i
or an
d
ex
t
er
i
or o
f
th
e un
it
can
b
e c
l
eane
d
us
i
ng p
l
ugg
i
ng
i
n wa
t
er.
1) Do not use an abrasive cleaners to avoid scratches on the surfaces.
4. The door-gasket should be cleaned to avoid maintain proper sealing.
4

Operation
1. The temperature controller (thermostat) is located on the upper left of the back side of the
cabinet interior.
2. The controller has been preset "NORMAL" position at the factory.
3. Set the control-knob toward "COOL" for higher temperature and "COLD"
for lower temperature.
4. The thermostat controls compressor's ON/OFF by sensing inside temperatures of cabinet.
5. The unit is equipped with an off-cycle defrost.
5

Troubleshooting
Problem Possible Cause Action
Compressor
will not start
Power connection failure Check Power Cord and plug it in
Power switch is in off position Change it on position
Temperature set point is too high Correct temperature set point
The door is opened too frequently -
Loading of too much warm or
moist
product
-
The unit does not
refrigerate well
moist
product
Not enough ventilation Move the unit in a well
ventilated place with at least 7
inches of clearance on all sides
Condenser is clogged Clean it
Condensation
on cabinet exterior High moisture air can produce
dews during the rainy season Wipe with cloth
※The following is not an indication of problem or malfunction;
A water-flowing sound can be heard when the unit is operating.
Thiith df fi tfl i
Thi
s
i
s
th
e soun
d
o
f
re
f
r
i
geran
t
fl
ow
i
ng.
6

Installing Casters
1. Remove the outer packing.
2. Install the castors in the area.
3. Maker sure that castors with brakes should be installed in front.
7

8
WARRANTY CERTIFICATE
Warranty Valid Only In the USA
This warranty is subject to all of the terms and conditions listed below. On-line warranty registration or Warranty card furnished with this unit must be
properly executed and returned to BLUE AIR immediately after installation. Failure to complete on-line registration or, to return the warranty registration
card to provided location will automatically void all warranties.
Standard Warranty
One(1) Year Parts & Labor Warranty: (On Selected Products – Chest Freezers)
BLUE AIR warrants to the original purchaser of the BLUE AIR unit sold and all parts thereof to be free from defects in material or workmanship, under
normal use and service for a period of one (1) year from the date of sale by Distributor or Dealer, or fifteen (15) months from date of shipment by Blue
Air, whichever occurs first. Unit lamps are NOT included in the warranty. Our obligation under this warranty shall be limited to repairing or replacing
F.O.B. factory any of such products that prove to be defective and which our examination shall disclose to our satisfaction to be defective.
Two (2) Years Parts and Labor Warranty: (On Selected Products – All refrigeration equipment except Chest Freezers)
BLUE AIR warrants to the original purchaser the BLUE AIR unit sold and all parts thereof to be free from defects in material or workmanship, under
normal use and service for a period of one and two years from the date of sale or twenty one (27) months from date of shipment by Blue Air, whichever
occurs first. Unit lamps are NOT included in the warranty. Our obligation under this warranty shall be limited to repairing or replacing F.O.B. factory any
of such products that prove to be defective and which our examination shall disclose to our satisfaction to be defective.
A) Any part returned to the company under the terms of this warranty must be accompanied by the record of the cabinet model number,
serial number, return authorization number and such return shall be on the basis of TRANSPORTATION CHARGES PREPAID.
B) Improper operation due to low voltage condition, inadequate wiring and accident damages are not manufacturing defects and are
strictly the responsibility of the purchaser.
C) Condenser coils must be cleaned at regular intervals. Failure to do so may cause the compressor to malfunction and will void the
warranty. This contract does not apply outside the limits of the U.S.A. nor does it to any part which has been subject of misuse,
neglect, alteration, accident or to any damage caused by transportation, flood, fire, or the acts of God. This contract is not effective
unless the BLUE AIR Warranty Card, furnished with each unit, is properly filled out and mailed back to BLUE AIR within twelve (12)
days from the date of installation. The term “Original Purchaser” as used herein shall be deemed to refer to that person, firm,
association, or company for whom the refrigeration unit refers to herein is originally installed.
Extended Warranty
One (1) year extended warranty for parts & labor is available for purchase at the time of purchasing equipment from our dealers.
Five-Year Compressor Warranty
BLUE AIR warrants the hermetically sealed compressor for an 60 months, for the STAINLESS STEEL REACH-INS, PREP TABLES, PIZZA
PREP UNDERCOUNTERS, CHEFBASES, UNDERBAR REFRIGERATION EQUIPMENT, GLASS DOOR REACH-INS, CHEST
FREEZERS/COOLERS and COUNTER TOP REFRIGERATION EQUIPMENT. Not to exceed sixty three(63) months from the date of
shipment from Blue Air warehouse, provided upon receipt of the compressor manufacturer examination shows the sealed compressor to be defective.
Lack of maintenance will result in a voided warranty. This extended warranty does not apply for any electrical controls, accumulator or wiring harnesses
which are covered by the standard warranty.
Warranty Claims
All labor claims or parts must include copy of original invoice submitted directly to Blue Air. All claims must included: a copy of original invoice (Customer
Name, address, model name, and Date of Sale) Customer Name, Phone Number, Model & Serial No of unit, date of sale, Distributors or Dealers name
and brief description of complaint. On all compressor warranties the compressor model tag must be returned to Blue Air along with the above
information. All claims must be reported to Blue Air within one (1) year of occurrence. All compressors have five (5) years warranty coverage. This
warranty will not be effective unless the warranty card is returned or registered (www.blueairinc.com) to Blue Air within 12 days of installation. Confirm
receipt of warranty registration by contacting Blue Air directly (1-866-677-8500)
Non Warranty Claims
Blue Air’s warranty service is limited to labor of repairing merchandise and/or parts replaced. This warranty does not authorize any person(s) to assume
any obligation or liability other than what the warranty permits. This warranty will be void if such action occurs. Any attempt to repair BLUE AIR products
without an official job number issued by BLUE AIR will not be covered by warranty and the services will not be compensated. This warranty does not
apply to any part, which has been subject to misuse, neglect, alteration, accident, or to any visible or concealed damage caused by transportation, flood,
fire, acts of God, etc.
Concealed Damage Example
Styrofoam may hide any hidden dents on the shipment that may not be completely visible. You must inspect all corners and grills thoroughly. If the
carrier stacks any contents on the units this can cause glass on the glass door units to break from the inside. All units are checked for any damages
before they are released.

9
No claims can be made against this warranty for lost product.
W
hat Is Not Covered By This Warranty
S
poilage of Product - No claims can be made against this warranty for any spoilage of products, such as food, loss of sales, or consequentia
l
d
amages. BLUE AIR is not responsible for the repair or replacement of any parts that BLUE AIR determines have been subjected after the date o
f
m
anufacture to alteration, neglect, abuse, misuse, accidents, damage during transit or installation, fire, flood, or acts of God.
W
arranty Is Non Transferable - This warranty is not assignable and applies only to the original purchaser/user to whom delivered. Any suc
h
a
ssignment or transfer will void this warranty and all other warranties implied.
I
mproper Usage - BLUEAIR is not liable in any way for parts or labor coverage for component failure or other damages resulting from improper usag
e
o
r installation or failure to clean and/or maintain product as mentioned in the warranty packet provided with the unit.
O
utside U.S. (Including Alaska) - This warranty does not apply to, and BLUE AIR is not responsible for, any warranty claims made on products sold o
r
u
sed outside the United States.
I
mproper Electrical Connections - BLUE AIR is not responsible for the repair or replacement of failed or damaged components resulting fro
m
e
lectrical power failure, the use of extension cords, low voltage, or voltage interference to the unit.
N
o Implied Warranty of Merchantability or Fitness for a Particular Purpose - There are no other warranties, expressed, implied or statutory, excep
t
p
arts and labor warranty and compressor warranty as described above. These warranties are exclusive and in lieu of all other warranties, includin
g
i
mplied warranty and merchantability or fitness for a particular purpose. There are no warranties, which extend beyond this mentioned description.
R
emote Condensers - BLUE AIR warrants the original purchaser of the remote cabinet one year parts and labor coverage for all cabinet parts thereo
f
t
o be free from defects in material or workmanship, under proper use and maintenance service, as specified by BLUE AIR. This warranty is limited to th
e
c
abinet only. BLUE AIR is not liable for remote condensing units.
BLUE AIR Commercial Refrigeration Inc.
223 W. Rosecrans Ave, Gardena, CA 90248
Phone: (866-677-8500), (310-808-0102),
Fax:(310) 808-0242
Email: info@blueairinc.com

MEMO
10

Warranty Registration Card
Customer Name Business Name
Blue Air Commercial Refrigeration Inc.
223 W. Rosecrans Ave. Gardena, CA 90248
Tel, 310-808-0102, Fax, 310-808-0242
Telephone : ( ) Telephone : ( )
suB(sserddA)remotsuC(sserddA iness or Installation Site)
desahcruPetaDesahcruPfoecalP
Date Installed
Street
City State Zip
Street
City State Zip
Place
of
Purchase
Date
Purchased
Date
Installed
Model Name Product Serial No.
Extended Warranty Option
Additional 1 Year Parts & Labor extended Warranty available
If you are interested, please contact Blue Air Customer Service Dept.
Yes, I would like the extended warrant
y
. / No, I would not like the extended warrant
y
.
Cut along dotted line and mail it back to ; BLUE AIR Customer Service Dept.223 W. Rosecrans Ave. Gardena, CA 90248
y
y
Signature of Business Owner Date
The Warranty becomes void if the attached warranty card is not filled out and returned to Blue Air within 15 days from the purchase date.
The Warranty becomes void if the attached warranty card is not filled out
and returned to Blue Air within 15 days from the purchase date.
Cut along dotted line and mail it back to ;
BLUE AIR Customer Service Dept.
223 W. Rosecrans Ave. Gardena, CA 90248

223 W. Rosecrans Ave. Gardena, CA 90248
Toll Free
,
1-86
6
-677-8500
BLUE AIR
,
TEL, (310) 808-0102
Fax, (310) 808-0242/0262
Visit our website at www.blueairinc.com
This manual suits for next models
11
Table of contents
Other Blueair Refrigerator manuals