Blueprint®Controllers put the power of automation to work in garden environments everywhere. For safety and optimal performance,
please carefully read this document in full before installing and operating this Blueprint®CO2Generator.
rev:92014
Features
• Two,four,eightortenpreinstalledliquidpropaneornaturalgasburners
• Electronicignitionprovidesreliablestarts
• Dualsolenoidvalveseliminateopenpilotame
• Includesgasregulator,12’hoseandhanginghardware
• Built-insafetytip-overswitch
• Three-yearwarranty
Liquidpropanehose
with regulator
Natural gas hose
with regulator
24-VDCpowersupply Hardware
Specifications
LiquidPropane(LP)
Max. Area
Size(CuFt)
Max.CO2
(CuFt/Hr) BTU Rating VariableOutput Gas Pressure Power
Requirements Dimensions
CGLP-2 2,000 5.3 2,263-4,526 1-2burners
11” WC/2.8 kPa 400mA@24-VDC
9” x 10” x 18”
CGLP-4 4,000 10.6 2,263-9,052 1-4burners 15” x 8.5” x 18”
CGLP-4H 4,000 8.4 1,788-7,152 1-4burners 15” x 8.5” x 18”
CGLP-8 8,000 21.2 2,263-18,104 1-8burners 15” x 9.8” x 18”
CGLP-8H 8,000 16.7 1,788-14,304 1-8burners 15” x 9.8” x 18”
CGLP-10 10,000 26.5 2,263-22,630 1-10burners 15” x 9.8” x 18”
NaturalGas(NG)
Max. Area
Size(CuFt)
Max.CO2
(CuFt/Hr) BTU Rating VariableOutput Gas Pressure Power
Requirements Dimensions
CGNG-2 2,000 5.4 2,767-5,534 1-2burners
4.5” WC/1.15 kPa 400mA@24-VDC
9” x 10” x 18”
CGNG-4 4,000 10.8 2,767-11,068 1-4burners 15” x 8.5” x 18”
CGNG-4H 4,000 9.6 2,455-9,820 1-4burners 15” x 8.5” x 18”
CGNG-8 8,000 21.6 2,767-22,136 1-8burners 15” x 9.8” x 18”
CGNG-8H 8,000 19.2 2,455-19,640 1-8burners 15” x 9.8” x 18”
CGNG-10 10,000 27.7 2,767-27,670 1-10burners 15” x 9.8” x 18”
•Failuretoreadandunderstandtheseinstructionsbeforeinstallingoroperatingthisproductcouldresultin
 personalinjuryorpropertydamage.
•Installationandconnectionofgaslinesmustbecompletedincompliancewithlocalandnationalregulations.
•Donotstoregasolineorotherammablegasesorliquidsneartheunit.
•KeepobjectsawayfromtheGeneratorastheelectrodesproducesparks.
•InstalltheGeneratorinanadequatelyventilatedarea.Withoutadequateventilation,CO2canreachtoxiclevels. 
 Levelsabove2500ppmcancauseheadachesandothersymptoms,andlevelsabove5000ppmaretoxic.
•DonotusethestandardGeneratorataltitudeshigherthan4,500ftabovesealeveliftheburnersareproducing
 yellowame.
•TheGeneratorisdesignedtobeoperatedonlywhilehanging.DonotoperatetheGeneratoronatableorother 
 surfacebecausetheunitrequiresunrestrictedairowthroughthebottomoftheunit.
•DonotturnontheGeneratorwithoutreadingthe“Start-upProcedure”section.
Installation
1. Use the provided hardware to securely hang the Generator from an overhead support, such as a ceiling beam. Leave
 atleast20”betweentheunitandthewall,ceiling,orothersurfacesorobjects.Installthescrewhooksintothe  
overhead support, then use the S hooks to attach the chain to the unit and the screw hooks. Bend the S hooks
to secure the chain.
2.VerifytheGeneratorishanginglevel.Theunithasabuilt-intip-overswitch,apendulum-likesafetyfeaturethatwillturn
 offthegassupplytotheburnersiftheunittipsover,fallsorisn’tlevel.
3.Connecttheprovidedgasregulatortotheliquidpropaneornaturalgassupply.ThegassupplytotheGenerator 
 mustberegulatedtoaverylowpressure(11”WCor½psiforliquidpropane,and4.5”WCor¼psifornaturalgas).
4.Useawrenchtoconnectoneendoftheincluded12’hosetothearettingontheunitandtheotherendtothe 
provided gas regulator.
5.Toverifytheconnectionsaresecure,checkforleaksbysprayingasoapsolutionontothegasconnectionttingswiththe
 shut-offvalveinopenposition.Ifbubblesappear,closetheshut-offvalve,retightentheconnectionandrepeat
the process.
LEDIndicators
TherearefourLEDindicatorsonthesideoftheGenerator,nearthepowerswitch.
•The“MainPowerON”LEDilluminateswhenthepowersupplyisconnectedandtheunitisturnedon.
•The“LockOutError”LEDashestoindicatetheignitioncontrolmodulehasshutoffthesolenoidvalvesandtheunitwill
not operate until it has been disconnected from and reconnected to power.
•The“PilotValveON”LEDilluminateswhentheignitioncontrolmoduleprovidesasparkfor15secondswhilethepilot 
 solenoidisactivated.TheLEDwillremainilluminatedduringoperation.
•The“MainValveON”LEDilluminateswhentheamesensordetectsaame.LEDremainsonduringoperation.
Start-upProcedure
1.Beforeinitiatingthestart-upprocedure,verifythepowerswitchisoffandtheGeneratorisnotpluggedin.
2.Pressurizethegaslinesbyopeningtheshut-offvalvesonthegassupply.Testforgasleaks,especiallyifthisistherst
time the unit has been used.
3.PlugtheGenerator’s24-VDCpowersupplyintoa120Vpowersource.
4.Connecttheotherendofthe24-VDCpowersupplycordtotheinletjackontheGenerator.
5.Turnthepowerswitchon.TheLEDlabeled“MainPowerON”willilluminate.
6.Theignitioncontrolmodulewillattempttoignitetheburnersforapproximately5seconds.TheLEDlabeled“PilotValve
ON” will illuminate.
7.Theburnersmaynotigniteinitiallyifthisisthersttimetheunitisbeingused.After30seconds,theunitwillattemptto
 ignitetheburnersfor15seconds.Theunitwillcontinueuntiltheburnerignitesorforamaximumofveattempts.
8.Ifveunsuccessfulattemptsaremade,themodulewilllockitselfoutandtheLEDlabeled“LockOutError”  
 willilluminate.TurnofftheGenerator,closetheshut-offvalve,andwait5minutestoallowthegastodissipatebefore 
attempting to restart the unit.
9.Whentheburnershaveignited,lookundertheunittoconrmtheameisblueandsteady,resemblingaowerorstar.
•Immediatelyturnofftheunitiftheameappearsyellow,excessivelylarge,orweakandlazy.Highgaspressure
 orincorrectgastypemayleadtoyelloworexcessivelyhighames.Lowgaspressuremaycausesmallorweak
 blueames.
•AftertheGeneratorhasbeentestedwithallburnersoperating,connecttheGeneratortoacontrollerortimer 
 thatwillcontrolthefrequencyanddurationoftheunit’soperation.
Warning
Warning
ModifyingCO2Output
ItisstronglyrecommendedtouseacontrollerortimingdevicetoproperlymanagetheoutputoftheGenerator.Ifthisis
notpossible,theGenerator’sCO2andheatoutputcanbemodiedbyusingtheprovidedbrasspipeplugstoreducethe
numberofactiveburners.Additionalplugsmaybepurchasedseparately.TheSpecicationstableshowsthesizeofthe
growing area that is appropriate for each model as well as how much CO2and heat are produced at maximum capacity.
EachburnerreplacedwithabrasspipeplugwillreducetheGenerator’soutputby2.65cuft/hrofCO2and2,263BTUfor
astandardliquidpropaneunit,2.7cuft/hrofCO2and2,767BTUforastandardnaturalgasunit,2.1cuft/hrofCO2and
1,788BTUforahighaltitudeliquidpropaneunit,and2.4cuft/hrofCO2and2,455BTUforahighaltitudenaturalgasunit.
TheCGLP-10andCGNG-10featuretheabilitytovaryCO2outputwiththeipofaswitch.Themainpowerswitchactivates
the two burners nearest the electrodes, and two additional selector switches independently activate two separate banks
offourburnerseach.Brasspipeplugsarealsoprovidedforfurthermodication.Todeterminetheappropriatenumberof
burnerstoactivateforthegrowingarea,dividethesizeofthegrowingarea(incubicfeet)by1,000.Forexample:Activate
six burners in a growing area of 6,000 cu ft.
ElectronicIgnitionControlModule
TheGenerator’selectronicignitioncontrolmoduleproducesasparkthatlightstheburners,eliminatingtheneedforanopen
pilotameandprovidingconsistent,controlledstarts.Themodulecontrolsdualredundantsolenoidvalves.
HighAltitudeGenerators
High Altitude Generators are specially designed to operate and compensate for reduced oxygen levels at altitudes higher
than4,500ftabovesealevel.BTUandCO2outputs will be reduced because there is less oxygen in the air at high altitudes
(seeSpecicationstable).
A High Altitude Generator may be operated at altitudes as low as 2,500 ft above sea level, but the unit should be tested
before use to ensure all burners ignite correctly and consistently.
FAQ
• Ismellgasaroundthegenerator,isthatnormal?
 No.Turnoffthegassupplyimmediately.Donotturnonanyelectricaldevices.Ventilatetheareaandleaveuntilthegassmell 
 dissipates.Turnthegassupplybackon,thendeterminewheretheleakisbysprayingsoapywateronthegasconnections.Retighten
the connections where bubbles appear.
• Whatdoesaashing“LockOutError”LEDmean?
 Thegassupplymayhavebeeninterrupted.“LockOut”isasafetyfeatureactivatedwhenthepilotdoesnotigniteafterveattempts. 
 Whentheproblemhasbeenxed,resetthe“LockOut”byturningthepowerofffor30secondsandthenbackon.Theunitwillreset 
automatically after 20 minutes and attempt to ignite the burners.
• ShouldtheGeneratorproducebuzzingorsparkingnoises?
 TheGeneratorwillproducebuzzingorsparkingnoisesonlywhentheunitisattemptingtoignitetheburners.
• Whatshouldtheameslooklike?
 Theamesshouldburncleanandblue,resemblingaowerorstar.Donotoperatethegeneratoriftheameisyellow,excessively 
large, or weak and lazy.
• Doesitmatterwhichburnersarereplacedwiththepipeplug?
 Theburnernearesttheelectrodesmustremaininplace.Removeandreplaceburnersstartingwiththeburnerfarthestawayfrom
the electrodes.
Troubleshooting
• Whyisn’ttheGeneratorworkingandwhyaren’ttheLEDsilluminatingeventhoughthepowerisconnected?
 Thetip-overswitchmayhavebeentriggered.Toreset,tilttheunittothesideandlistenforaclickingnoise.Ensuretheunitislevelto
avoid triggering the switch.
• Whywon’ttheburnersigniteeventhoughtheunitisattemptingtoignitethem?
 Verifytheunitisgeneratingasparkandtheburnerclosesttotheelectrodesisactive.Ensuretherearenokinksortwistsinthegas 
 lineandthegassupplyisadequate.Turnoffthegasregulatorfor30seconds,thentryagain.
• Whyisn’ttheCO2levelincreasingtothedesiredppm?
 Checkforairleakageinthegrowingarea.DonotoperateexhaustfanswhileCO2is being produced.
• Whatifthegrowingareagetstoohumidorhot?
 Reducethesettingsonthecontrollerortimingdevice.Ifanoutputcontrolisnotbeingused,burnerscanberemovedandreplaced 
with the provided brass pipe plugs.
rev:92014
Blueprint®CO2GeneratorLimitedWarranty
WhatThisWarrantyCovers
Thiswarrantycoversdefectsinmaterialsandworkmanshipundernormaluse,withanyexceptionslistedbelow.
WhoThisWarrantyCovers
Thiswarrantyappliestotheoriginalpurchaserofthisproductwiththeoriginalproofofpurchase.
HowLongWarrantyCoverageLasts
Thiswarrantyisineffectforaperiodofthreeyearsfromtheoriginaldateofpurchase.
WhatThisWarrantyDoesNotCover
Thiswarrantydoesnotcoverdamageordefectsresultingfromtheimproperinstallation,alteration,abuse,accidentaldamage,unauthorized
repairormisuseofthisproduct.Misuseincludesbutisnotlimitedtooutdooruse.Thiswarrantydoesnotapplytocosmeticdefectsorother
defectsthatdonotaffectthefunctionalityoftheproduct,andisvoidiftheproducthasbeendamagedasaresultofre,ood,orothernatural
disaster.SunleavesGardenProducts(“Sunleaves”)shallnotberesponsibleforanyincidentalorconsequentialdamagesofanynature,including
damageorinjurycausedtootherproducts,machinery,buildingsorproperty;lossofprots,timeorproduct;orinconvenience.Thiswarrantyis
giveninlieuofallotherwarranties,expressorimplied,includingwithoutlimitationmerchantabilityandtnessforaparticularpurpose.
Somestatesdonotallowtheexclusionorlimitationofincidentalandconsequentialdamages,orlimitationsonhowlonganimplied
warrantylasts,sotheabovelimitation(s)maynotapplytoyou.
WhatSunleavesWillDo
IfSunleavesdeterminesthewarrantedproductisdefectiveinmaterialorworkmanshipduringthewarrantyperiod,thenSunleaves,atitsoption,
willeitherrepairorreplacetheproduct.Innoeventshallthecostofrepairorreplacementexceedtheoriginalpurchaseprice.
HowtoObtainWarrantyService
Returnthisproductalongwiththeoriginalproofofpurchasetotheplaceofpurchaseinaccordancewithstorepolicy.Theoriginalproofof
purchaseMUSTaccompanytheBlueprint®product for this warranty to be valid.
HowStateLawApplies
Thiswarrantygivesyouspeciclegalrights,andyoumayalsohaveotherrightswhichvaryfromstatetostate.
Fortechnicalsupportandwarrantyinformation,calltoll-free888-464-9676oremail[email protected].

This manual suits for next models

11

Popular Portable Generator manuals by other brands

Shindaiwa DG150MM Owners and operation manual

Shindaiwa

Shindaiwa DG150MM Owners and operation manual

Mosa GE 17054 HBT Use and maintenance manual

Mosa

Mosa GE 17054 HBT Use and maintenance manual

Winco DR45F4/1 Installation & operator's manual

Winco

Winco DR45F4/1 Installation & operator's manual

Harrison Hydra-Gen Operation and installation guide

Harrison

Harrison Hydra-Gen Operation and installation guide

Briggs & Stratton 01810-0 Installation and start-up manual

Briggs & Stratton

Briggs & Stratton 01810-0 Installation and start-up manual

Pulsar G465GN Operator's manual

Pulsar

Pulsar G465GN Operator's manual

RDL STICK-ON ST-RG1 quick start guide

RDL

RDL STICK-ON ST-RG1 quick start guide

NORTHMARK YDE2800X/E user manual

NORTHMARK

NORTHMARK YDE2800X/E user manual

Fischer Panda AGT 6000 PVMV-N manual

Fischer Panda

Fischer Panda AGT 6000 PVMV-N manual

Stow LT-12D Operation manual

Stow

Stow LT-12D Operation manual

Cebora POWER SPOT 5500 Service manual

Cebora

Cebora POWER SPOT 5500 Service manual

Hyundai HY3600SEi operating instructions

Hyundai

Hyundai HY3600SEi operating instructions

DUROMAX XP4850EH-081418 user manual

DUROMAX

DUROMAX XP4850EH-081418 user manual

Yamaha EF6300iSDE owner's manual

Yamaha

Yamaha EF6300iSDE owner's manual

Chamberlain A7008890 manual

Chamberlain

Chamberlain A7008890 manual

K&S BASIC KSB 12i S manual

K&S BASIC

K&S BASIC KSB 12i S manual

Champion 201230 quick start

Champion

Champion 201230 quick start

Fluke Wavetek-Datron 395 User handbook

Fluke

Fluke Wavetek-Datron 395 User handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.