Blueprint®Controllers put the power of automation to work in garden environments everywhere. For safety and optimal performance,
please carefully read this document in full before installing and operating this Blueprint®CO2Generator.
rev:92014
Features
• Two,four,eightortenpreinstalledliquidpropaneornaturalgasburners
• Electronicignitionprovidesreliablestarts
• Dualsolenoidvalveseliminateopenpilotame
• Includesgasregulator,12’hoseandhanginghardware
• Built-insafetytip-overswitch
• Three-yearwarranty
Liquidpropanehose
with regulator
Natural gas hose
with regulator
24-VDCpowersupply Hardware
Specifications
LiquidPropane(LP)
Max. Area
Size(CuFt)
Max.CO2
(CuFt/Hr) BTU Rating VariableOutput Gas Pressure Power
Requirements Dimensions
CGLP-2 2,000 5.3 2,263-4,526 1-2burners
11” WC/2.8 kPa 400mA@24-VDC
9” x 10” x 18”
CGLP-4 4,000 10.6 2,263-9,052 1-4burners 15” x 8.5” x 18”
CGLP-4H 4,000 8.4 1,788-7,152 1-4burners 15” x 8.5” x 18”
CGLP-8 8,000 21.2 2,263-18,104 1-8burners 15” x 9.8” x 18”
CGLP-8H 8,000 16.7 1,788-14,304 1-8burners 15” x 9.8” x 18”
CGLP-10 10,000 26.5 2,263-22,630 1-10burners 15” x 9.8” x 18”
NaturalGas(NG)
Max. Area
Size(CuFt)
Max.CO2
(CuFt/Hr) BTU Rating VariableOutput Gas Pressure Power
Requirements Dimensions
CGNG-2 2,000 5.4 2,767-5,534 1-2burners
4.5” WC/1.15 kPa 400mA@24-VDC
9” x 10” x 18”
CGNG-4 4,000 10.8 2,767-11,068 1-4burners 15” x 8.5” x 18”
CGNG-4H 4,000 9.6 2,455-9,820 1-4burners 15” x 8.5” x 18”
CGNG-8 8,000 21.6 2,767-22,136 1-8burners 15” x 9.8” x 18”
CGNG-8H 8,000 19.2 2,455-19,640 1-8burners 15” x 9.8” x 18”
CGNG-10 10,000 27.7 2,767-27,670 1-10burners 15” x 9.8” x 18”
•Failuretoreadandunderstandtheseinstructionsbeforeinstallingoroperatingthisproductcouldresultin
 personalinjuryorpropertydamage.
•Installationandconnectionofgaslinesmustbecompletedincompliancewithlocalandnationalregulations.
•Donotstoregasolineorotherammablegasesorliquidsneartheunit.
•KeepobjectsawayfromtheGeneratorastheelectrodesproducesparks.
•InstalltheGeneratorinanadequatelyventilatedarea.Withoutadequateventilation,CO2canreachtoxiclevels. 
 Levelsabove2500ppmcancauseheadachesandothersymptoms,andlevelsabove5000ppmaretoxic.
•DonotusethestandardGeneratorataltitudeshigherthan4,500ftabovesealeveliftheburnersareproducing
 yellowame.
•TheGeneratorisdesignedtobeoperatedonlywhilehanging.DonotoperatetheGeneratoronatableorother 
 surfacebecausetheunitrequiresunrestrictedairowthroughthebottomoftheunit.
•DonotturnontheGeneratorwithoutreadingthe“Start-upProcedure”section.
Installation
1. Use the provided hardware to securely hang the Generator from an overhead support, such as a ceiling beam. Leave
 atleast20”betweentheunitandthewall,ceiling,orothersurfacesorobjects.Installthescrewhooksintothe  
overhead support, then use the S hooks to attach the chain to the unit and the screw hooks. Bend the S hooks
to secure the chain.
2.VerifytheGeneratorishanginglevel.Theunithasabuilt-intip-overswitch,apendulum-likesafetyfeaturethatwillturn
 offthegassupplytotheburnersiftheunittipsover,fallsorisn’tlevel.
3.Connecttheprovidedgasregulatortotheliquidpropaneornaturalgassupply.ThegassupplytotheGenerator 
 mustberegulatedtoaverylowpressure(11”WCor½psiforliquidpropane,and4.5”WCor¼psifornaturalgas).
4.Useawrenchtoconnectoneendoftheincluded12’hosetothearettingontheunitandtheotherendtothe 
provided gas regulator.
5.Toverifytheconnectionsaresecure,checkforleaksbysprayingasoapsolutionontothegasconnectionttingswiththe
 shut-offvalveinopenposition.Ifbubblesappear,closetheshut-offvalve,retightentheconnectionandrepeat
the process.
LEDIndicators
TherearefourLEDindicatorsonthesideoftheGenerator,nearthepowerswitch.
•The“MainPowerON”LEDilluminateswhenthepowersupplyisconnectedandtheunitisturnedon.
•The“LockOutError”LEDashestoindicatetheignitioncontrolmodulehasshutoffthesolenoidvalvesandtheunitwill
not operate until it has been disconnected from and reconnected to power.
•The“PilotValveON”LEDilluminateswhentheignitioncontrolmoduleprovidesasparkfor15secondswhilethepilot 
 solenoidisactivated.TheLEDwillremainilluminatedduringoperation.
•The“MainValveON”LEDilluminateswhentheamesensordetectsaame.LEDremainsonduringoperation.
Start-upProcedure
1.Beforeinitiatingthestart-upprocedure,verifythepowerswitchisoffandtheGeneratorisnotpluggedin.
2.Pressurizethegaslinesbyopeningtheshut-offvalvesonthegassupply.Testforgasleaks,especiallyifthisistherst
time the unit has been used.
3.PlugtheGenerator’s24-VDCpowersupplyintoa120Vpowersource.
4.Connecttheotherendofthe24-VDCpowersupplycordtotheinletjackontheGenerator.
5.Turnthepowerswitchon.TheLEDlabeled“MainPowerON”willilluminate.
6.Theignitioncontrolmodulewillattempttoignitetheburnersforapproximately5seconds.TheLEDlabeled“PilotValve
ON” will illuminate.
7.Theburnersmaynotigniteinitiallyifthisisthersttimetheunitisbeingused.After30seconds,theunitwillattemptto
 ignitetheburnersfor15seconds.Theunitwillcontinueuntiltheburnerignitesorforamaximumofveattempts.
8.Ifveunsuccessfulattemptsaremade,themodulewilllockitselfoutandtheLEDlabeled“LockOutError”  
 willilluminate.TurnofftheGenerator,closetheshut-offvalve,andwait5minutestoallowthegastodissipatebefore 
attempting to restart the unit.
9.Whentheburnershaveignited,lookundertheunittoconrmtheameisblueandsteady,resemblingaowerorstar.
•Immediatelyturnofftheunitiftheameappearsyellow,excessivelylarge,orweakandlazy.Highgaspressure
 orincorrectgastypemayleadtoyelloworexcessivelyhighames.Lowgaspressuremaycausesmallorweak
 blueames.
•AftertheGeneratorhasbeentestedwithallburnersoperating,connecttheGeneratortoacontrollerortimer 
 thatwillcontrolthefrequencyanddurationoftheunit’soperation.
Warning
Warning
ModifyingCO2Output
ItisstronglyrecommendedtouseacontrollerortimingdevicetoproperlymanagetheoutputoftheGenerator.Ifthisis
notpossible,theGenerator’sCO2andheatoutputcanbemodiedbyusingtheprovidedbrasspipeplugstoreducethe
numberofactiveburners.Additionalplugsmaybepurchasedseparately.TheSpecicationstableshowsthesizeofthe
growing area that is appropriate for each model as well as how much CO2and heat are produced at maximum capacity.
EachburnerreplacedwithabrasspipeplugwillreducetheGenerator’soutputby2.65cuft/hrofCO2and2,263BTUfor
astandardliquidpropaneunit,2.7cuft/hrofCO2and2,767BTUforastandardnaturalgasunit,2.1cuft/hrofCO2and
1,788BTUforahighaltitudeliquidpropaneunit,and2.4cuft/hrofCO2and2,455BTUforahighaltitudenaturalgasunit.
TheCGLP-10andCGNG-10featuretheabilitytovaryCO2outputwiththeipofaswitch.Themainpowerswitchactivates
the two burners nearest the electrodes, and two additional selector switches independently activate two separate banks
offourburnerseach.Brasspipeplugsarealsoprovidedforfurthermodication.Todeterminetheappropriatenumberof
burnerstoactivateforthegrowingarea,dividethesizeofthegrowingarea(incubicfeet)by1,000.Forexample:Activate
six burners in a growing area of 6,000 cu ft.
ElectronicIgnitionControlModule
TheGenerator’selectronicignitioncontrolmoduleproducesasparkthatlightstheburners,eliminatingtheneedforanopen
pilotameandprovidingconsistent,controlledstarts.Themodulecontrolsdualredundantsolenoidvalves.
HighAltitudeGenerators
High Altitude Generators are specially designed to operate and compensate for reduced oxygen levels at altitudes higher
than4,500ftabovesealevel.BTUandCO2outputs will be reduced because there is less oxygen in the air at high altitudes
(seeSpecicationstable).
A High Altitude Generator may be operated at altitudes as low as 2,500 ft above sea level, but the unit should be tested
before use to ensure all burners ignite correctly and consistently.
FAQ
• Ismellgasaroundthegenerator,isthatnormal?
 No.Turnoffthegassupplyimmediately.Donotturnonanyelectricaldevices.Ventilatetheareaandleaveuntilthegassmell 
 dissipates.Turnthegassupplybackon,thendeterminewheretheleakisbysprayingsoapywateronthegasconnections.Retighten
the connections where bubbles appear.
• Whatdoesaashing“LockOutError”LEDmean?
 Thegassupplymayhavebeeninterrupted.“LockOut”isasafetyfeatureactivatedwhenthepilotdoesnotigniteafterveattempts. 
 Whentheproblemhasbeenxed,resetthe“LockOut”byturningthepowerofffor30secondsandthenbackon.Theunitwillreset 
automatically after 20 minutes and attempt to ignite the burners.
• ShouldtheGeneratorproducebuzzingorsparkingnoises?
 TheGeneratorwillproducebuzzingorsparkingnoisesonlywhentheunitisattemptingtoignitetheburners.
• Whatshouldtheameslooklike?
 Theamesshouldburncleanandblue,resemblingaowerorstar.Donotoperatethegeneratoriftheameisyellow,excessively 
large, or weak and lazy.
• Doesitmatterwhichburnersarereplacedwiththepipeplug?
 Theburnernearesttheelectrodesmustremaininplace.Removeandreplaceburnersstartingwiththeburnerfarthestawayfrom
the electrodes.
Troubleshooting
• Whyisn’ttheGeneratorworkingandwhyaren’ttheLEDsilluminatingeventhoughthepowerisconnected?
 Thetip-overswitchmayhavebeentriggered.Toreset,tilttheunittothesideandlistenforaclickingnoise.Ensuretheunitislevelto
avoid triggering the switch.
• Whywon’ttheburnersigniteeventhoughtheunitisattemptingtoignitethem?
 Verifytheunitisgeneratingasparkandtheburnerclosesttotheelectrodesisactive.Ensuretherearenokinksortwistsinthegas 
 lineandthegassupplyisadequate.Turnoffthegasregulatorfor30seconds,thentryagain.
• Whyisn’ttheCO2levelincreasingtothedesiredppm?
 Checkforairleakageinthegrowingarea.DonotoperateexhaustfanswhileCO2is being produced.
• Whatifthegrowingareagetstoohumidorhot?
 Reducethesettingsonthecontrollerortimingdevice.Ifanoutputcontrolisnotbeingused,burnerscanberemovedandreplaced 
with the provided brass pipe plugs.
rev:92014
Blueprint®CO2GeneratorLimitedWarranty
WhatThisWarrantyCovers
Thiswarrantycoversdefectsinmaterialsandworkmanshipundernormaluse,withanyexceptionslistedbelow.
WhoThisWarrantyCovers
Thiswarrantyappliestotheoriginalpurchaserofthisproductwiththeoriginalproofofpurchase.
HowLongWarrantyCoverageLasts
Thiswarrantyisineffectforaperiodofthreeyearsfromtheoriginaldateofpurchase.
WhatThisWarrantyDoesNotCover
Thiswarrantydoesnotcoverdamageordefectsresultingfromtheimproperinstallation,alteration,abuse,accidentaldamage,unauthorized
repairormisuseofthisproduct.Misuseincludesbutisnotlimitedtooutdooruse.Thiswarrantydoesnotapplytocosmeticdefectsorother
defectsthatdonotaffectthefunctionalityoftheproduct,andisvoidiftheproducthasbeendamagedasaresultofre,ood,orothernatural
disaster.SunleavesGardenProducts(“Sunleaves”)shallnotberesponsibleforanyincidentalorconsequentialdamagesofanynature,including
damageorinjurycausedtootherproducts,machinery,buildingsorproperty;lossofprots,timeorproduct;orinconvenience.Thiswarrantyis
giveninlieuofallotherwarranties,expressorimplied,includingwithoutlimitationmerchantabilityandtnessforaparticularpurpose.
Somestatesdonotallowtheexclusionorlimitationofincidentalandconsequentialdamages,orlimitationsonhowlonganimplied
warrantylasts,sotheabovelimitation(s)maynotapplytoyou.
WhatSunleavesWillDo
IfSunleavesdeterminesthewarrantedproductisdefectiveinmaterialorworkmanshipduringthewarrantyperiod,thenSunleaves,atitsoption,
willeitherrepairorreplacetheproduct.Innoeventshallthecostofrepairorreplacementexceedtheoriginalpurchaseprice.
HowtoObtainWarrantyService
Returnthisproductalongwiththeoriginalproofofpurchasetotheplaceofpurchaseinaccordancewithstorepolicy.Theoriginalproofof
purchaseMUSTaccompanytheBlueprint®product for this warranty to be valid.
HowStateLawApplies
Thiswarrantygivesyouspeciclegalrights,andyoumayalsohaveotherrightswhichvaryfromstatetostate.
Fortechnicalsupportandwarrantyinformation,calltoll-free888-464-9676oremail[email protected].

This manual suits for next models

11

Popular Portable Generator manuals by other brands

Siemens SINAMICS S220 Equipment manual

Siemens

Siemens SINAMICS S220 Equipment manual

Miller Big Blue 500X Eco Pro owner's manual

Miller

Miller Big Blue 500X Eco Pro owner's manual

Toyama TDMLG4004-T9C owner's manual

Toyama

Toyama TDMLG4004-T9C owner's manual

Mosa GE 60 FSX-5 Use and maintenance manual

Mosa

Mosa GE 60 FSX-5 Use and maintenance manual

Tegam 2411B Operation manual

Tegam

Tegam 2411B Operation manual

Power SUA2301i quick start guide

Power

Power SUA2301i quick start guide

Siemens SG020 Series owner's manual

Siemens

Siemens SG020 Series owner's manual

Craftsman 580.675512 Operator's manual

Craftsman

Craftsman 580.675512 Operator's manual

National Instruments NI PXIe-5450 SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION

National Instruments

National Instruments NI PXIe-5450 SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION

Firman W03383 owner's manual

Firman

Firman W03383 owner's manual

Tektronix FG501 instruction manual

Tektronix

Tektronix FG501 instruction manual

Sycamore 3500L owner's manual

Sycamore

Sycamore 3500L owner's manual

Rohde & Schwarz SMBV-K48 operating manual

Rohde & Schwarz

Rohde & Schwarz SMBV-K48 operating manual

Pulsar PG7750B owner's manual

Pulsar

Pulsar PG7750B owner's manual

Briggs & Stratton 14000 Series installation instructions

Briggs & Stratton

Briggs & Stratton 14000 Series installation instructions

King Canada 1500W Gasoline Generator KCG-1500G instruction manual

King Canada

King Canada 1500W Gasoline Generator KCG-1500G instruction manual

Champion 75531i Owner's manual & operating instructions

Champion

Champion 75531i Owner's manual & operating instructions

Powermate PC0525302.05 owner's manual

Powermate

Powermate PC0525302.05 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.