Blueprint®Controllers put the power of automation to work in garden environments everywhere. For safety and optimal performance,
please carefully read this document in full before installing and operating this Blueprint®CO2Generator.
rev:92014
Features
• Two,four,eightortenpreinstalledliquidpropaneornaturalgasburners
• Electronicignitionprovidesreliablestarts
• Dualsolenoidvalveseliminateopenpilotame
• Includesgasregulator,12’hoseandhanginghardware
• Built-insafetytip-overswitch
• Three-yearwarranty
Liquidpropanehose
with regulator
Natural gas hose
with regulator
24-VDCpowersupply Hardware
Specifications
LiquidPropane(LP)
Max. Area
Size(CuFt)
Max.CO2
(CuFt/Hr) BTU Rating VariableOutput Gas Pressure Power
Requirements Dimensions
CGLP-2 2,000 5.3 2,263-4,526 1-2burners
11” WC/2.8 kPa 400mA@24-VDC
9” x 10” x 18”
CGLP-4 4,000 10.6 2,263-9,052 1-4burners 15” x 8.5” x 18”
CGLP-4H 4,000 8.4 1,788-7,152 1-4burners 15” x 8.5” x 18”
CGLP-8 8,000 21.2 2,263-18,104 1-8burners 15” x 9.8” x 18”
CGLP-8H 8,000 16.7 1,788-14,304 1-8burners 15” x 9.8” x 18”
CGLP-10 10,000 26.5 2,263-22,630 1-10burners 15” x 9.8” x 18”
NaturalGas(NG)
Max. Area
Size(CuFt)
Max.CO2
(CuFt/Hr) BTU Rating VariableOutput Gas Pressure Power
Requirements Dimensions
CGNG-2 2,000 5.4 2,767-5,534 1-2burners
4.5” WC/1.15 kPa 400mA@24-VDC
9” x 10” x 18”
CGNG-4 4,000 10.8 2,767-11,068 1-4burners 15” x 8.5” x 18”
CGNG-4H 4,000 9.6 2,455-9,820 1-4burners 15” x 8.5” x 18”
CGNG-8 8,000 21.6 2,767-22,136 1-8burners 15” x 9.8” x 18”
CGNG-8H 8,000 19.2 2,455-19,640 1-8burners 15” x 9.8” x 18”
CGNG-10 10,000 27.7 2,767-27,670 1-10burners 15” x 9.8” x 18”

•Failuretoreadandunderstandtheseinstructionsbeforeinstallingoroperatingthisproductcouldresultin
personalinjuryorpropertydamage.
•Installationandconnectionofgaslinesmustbecompletedincompliancewithlocalandnationalregulations.
•Donotstoregasolineorotherammablegasesorliquidsneartheunit.
•KeepobjectsawayfromtheGeneratorastheelectrodesproducesparks.
•InstalltheGeneratorinanadequatelyventilatedarea.Withoutadequateventilation,CO2canreachtoxiclevels.
Levelsabove2500ppmcancauseheadachesandothersymptoms,andlevelsabove5000ppmaretoxic.
•DonotusethestandardGeneratorataltitudeshigherthan4,500ftabovesealeveliftheburnersareproducing
yellowame.
•TheGeneratorisdesignedtobeoperatedonlywhilehanging.DonotoperatetheGeneratoronatableorother
surfacebecausetheunitrequiresunrestrictedairowthroughthebottomoftheunit.
•DonotturnontheGeneratorwithoutreadingthe“Start-upProcedure”section.
Installation
1. Use the provided hardware to securely hang the Generator from an overhead support, such as a ceiling beam. Leave
atleast20”betweentheunitandthewall,ceiling,orothersurfacesorobjects.Installthescrewhooksintothe
overhead support, then use the S hooks to attach the chain to the unit and the screw hooks. Bend the S hooks
to secure the chain.
2.VerifytheGeneratorishanginglevel.Theunithasabuilt-intip-overswitch,apendulum-likesafetyfeaturethatwillturn
offthegassupplytotheburnersiftheunittipsover,fallsorisn’tlevel.
3.Connecttheprovidedgasregulatortotheliquidpropaneornaturalgassupply.ThegassupplytotheGenerator
mustberegulatedtoaverylowpressure(11”WCor½psiforliquidpropane,and4.5”WCor¼psifornaturalgas).
4.Useawrenchtoconnectoneendoftheincluded12’hosetothearettingontheunitandtheotherendtothe
provided gas regulator.
5.Toverifytheconnectionsaresecure,checkforleaksbysprayingasoapsolutionontothegasconnectionttingswiththe
shut-offvalveinopenposition.Ifbubblesappear,closetheshut-offvalve,retightentheconnectionandrepeat
the process.
LEDIndicators
TherearefourLEDindicatorsonthesideoftheGenerator,nearthepowerswitch.
•The“MainPowerON”LEDilluminateswhenthepowersupplyisconnectedandtheunitisturnedon.
•The“LockOutError”LEDashestoindicatetheignitioncontrolmodulehasshutoffthesolenoidvalvesandtheunitwill
not operate until it has been disconnected from and reconnected to power.
•The“PilotValveON”LEDilluminateswhentheignitioncontrolmoduleprovidesasparkfor15secondswhilethepilot
solenoidisactivated.TheLEDwillremainilluminatedduringoperation.
•The“MainValveON”LEDilluminateswhentheamesensordetectsaame.LEDremainsonduringoperation.
Start-upProcedure
1.Beforeinitiatingthestart-upprocedure,verifythepowerswitchisoffandtheGeneratorisnotpluggedin.
2.Pressurizethegaslinesbyopeningtheshut-offvalvesonthegassupply.Testforgasleaks,especiallyifthisistherst
time the unit has been used.
3.PlugtheGenerator’s24-VDCpowersupplyintoa120Vpowersource.
4.Connecttheotherendofthe24-VDCpowersupplycordtotheinletjackontheGenerator.
5.Turnthepowerswitchon.TheLEDlabeled“MainPowerON”willilluminate.
6.Theignitioncontrolmodulewillattempttoignitetheburnersforapproximately5seconds.TheLEDlabeled“PilotValve
ON” will illuminate.
7.Theburnersmaynotigniteinitiallyifthisisthersttimetheunitisbeingused.After30seconds,theunitwillattemptto
ignitetheburnersfor15seconds.Theunitwillcontinueuntiltheburnerignitesorforamaximumofveattempts.
8.Ifveunsuccessfulattemptsaremade,themodulewilllockitselfoutandtheLEDlabeled“LockOutError”
willilluminate.TurnofftheGenerator,closetheshut-offvalve,andwait5minutestoallowthegastodissipatebefore
attempting to restart the unit.
9.Whentheburnershaveignited,lookundertheunittoconrmtheameisblueandsteady,resemblingaowerorstar.
•Immediatelyturnofftheunitiftheameappearsyellow,excessivelylarge,orweakandlazy.Highgaspressure
orincorrectgastypemayleadtoyelloworexcessivelyhighames.Lowgaspressuremaycausesmallorweak
blueames.
•AftertheGeneratorhasbeentestedwithallburnersoperating,connecttheGeneratortoacontrollerortimer
thatwillcontrolthefrequencyanddurationoftheunit’soperation.
Warning
Warning

ModifyingCO2Output
ItisstronglyrecommendedtouseacontrollerortimingdevicetoproperlymanagetheoutputoftheGenerator.Ifthisis
notpossible,theGenerator’sCO2andheatoutputcanbemodiedbyusingtheprovidedbrasspipeplugstoreducethe
numberofactiveburners.Additionalplugsmaybepurchasedseparately.TheSpecicationstableshowsthesizeofthe
growing area that is appropriate for each model as well as how much CO2and heat are produced at maximum capacity.
EachburnerreplacedwithabrasspipeplugwillreducetheGenerator’soutputby2.65cuft/hrofCO2and2,263BTUfor
astandardliquidpropaneunit,2.7cuft/hrofCO2and2,767BTUforastandardnaturalgasunit,2.1cuft/hrofCO2and
1,788BTUforahighaltitudeliquidpropaneunit,and2.4cuft/hrofCO2and2,455BTUforahighaltitudenaturalgasunit.
TheCGLP-10andCGNG-10featuretheabilitytovaryCO2outputwiththeipofaswitch.Themainpowerswitchactivates
the two burners nearest the electrodes, and two additional selector switches independently activate two separate banks
offourburnerseach.Brasspipeplugsarealsoprovidedforfurthermodication.Todeterminetheappropriatenumberof
burnerstoactivateforthegrowingarea,dividethesizeofthegrowingarea(incubicfeet)by1,000.Forexample:Activate
six burners in a growing area of 6,000 cu ft.
ElectronicIgnitionControlModule
TheGenerator’selectronicignitioncontrolmoduleproducesasparkthatlightstheburners,eliminatingtheneedforanopen
pilotameandprovidingconsistent,controlledstarts.Themodulecontrolsdualredundantsolenoidvalves.
HighAltitudeGenerators
High Altitude Generators are specially designed to operate and compensate for reduced oxygen levels at altitudes higher
than4,500ftabovesealevel.BTUandCO2outputs will be reduced because there is less oxygen in the air at high altitudes
(seeSpecicationstable).
A High Altitude Generator may be operated at altitudes as low as 2,500 ft above sea level, but the unit should be tested
before use to ensure all burners ignite correctly and consistently.
FAQ
• Ismellgasaroundthegenerator,isthatnormal?
No.Turnoffthegassupplyimmediately.Donotturnonanyelectricaldevices.Ventilatetheareaandleaveuntilthegassmell
dissipates.Turnthegassupplybackon,thendeterminewheretheleakisbysprayingsoapywateronthegasconnections.Retighten
the connections where bubbles appear.
• Whatdoesaashing“LockOutError”LEDmean?
Thegassupplymayhavebeeninterrupted.“LockOut”isasafetyfeatureactivatedwhenthepilotdoesnotigniteafterveattempts.
Whentheproblemhasbeenxed,resetthe“LockOut”byturningthepowerofffor30secondsandthenbackon.Theunitwillreset
automatically after 20 minutes and attempt to ignite the burners.
• ShouldtheGeneratorproducebuzzingorsparkingnoises?
TheGeneratorwillproducebuzzingorsparkingnoisesonlywhentheunitisattemptingtoignitetheburners.
• Whatshouldtheameslooklike?
Theamesshouldburncleanandblue,resemblingaowerorstar.Donotoperatethegeneratoriftheameisyellow,excessively
large, or weak and lazy.
• Doesitmatterwhichburnersarereplacedwiththepipeplug?
Theburnernearesttheelectrodesmustremaininplace.Removeandreplaceburnersstartingwiththeburnerfarthestawayfrom
the electrodes.
Troubleshooting
• Whyisn’ttheGeneratorworkingandwhyaren’ttheLEDsilluminatingeventhoughthepowerisconnected?
Thetip-overswitchmayhavebeentriggered.Toreset,tilttheunittothesideandlistenforaclickingnoise.Ensuretheunitislevelto
avoid triggering the switch.
• Whywon’ttheburnersigniteeventhoughtheunitisattemptingtoignitethem?
Verifytheunitisgeneratingasparkandtheburnerclosesttotheelectrodesisactive.Ensuretherearenokinksortwistsinthegas
lineandthegassupplyisadequate.Turnoffthegasregulatorfor30seconds,thentryagain.
• Whyisn’ttheCO2levelincreasingtothedesiredppm?
Checkforairleakageinthegrowingarea.DonotoperateexhaustfanswhileCO2is being produced.
• Whatifthegrowingareagetstoohumidorhot?
Reducethesettingsonthecontrollerortimingdevice.Ifanoutputcontrolisnotbeingused,burnerscanberemovedandreplaced
with the provided brass pipe plugs.

rev:92014
Blueprint®CO2GeneratorLimitedWarranty
WhatThisWarrantyCovers
Thiswarrantycoversdefectsinmaterialsandworkmanshipundernormaluse,withanyexceptionslistedbelow.
WhoThisWarrantyCovers
Thiswarrantyappliestotheoriginalpurchaserofthisproductwiththeoriginalproofofpurchase.
HowLongWarrantyCoverageLasts
Thiswarrantyisineffectforaperiodofthreeyearsfromtheoriginaldateofpurchase.
WhatThisWarrantyDoesNotCover
Thiswarrantydoesnotcoverdamageordefectsresultingfromtheimproperinstallation,alteration,abuse,accidentaldamage,unauthorized
repairormisuseofthisproduct.Misuseincludesbutisnotlimitedtooutdooruse.Thiswarrantydoesnotapplytocosmeticdefectsorother
defectsthatdonotaffectthefunctionalityoftheproduct,andisvoidiftheproducthasbeendamagedasaresultofre,ood,orothernatural
disaster.SunleavesGardenProducts(“Sunleaves”)shallnotberesponsibleforanyincidentalorconsequentialdamagesofanynature,including
damageorinjurycausedtootherproducts,machinery,buildingsorproperty;lossofprots,timeorproduct;orinconvenience.Thiswarrantyis
giveninlieuofallotherwarranties,expressorimplied,includingwithoutlimitationmerchantabilityandtnessforaparticularpurpose.
Somestatesdonotallowtheexclusionorlimitationofincidentalandconsequentialdamages,orlimitationsonhowlonganimplied
warrantylasts,sotheabovelimitation(s)maynotapplytoyou.
WhatSunleavesWillDo
IfSunleavesdeterminesthewarrantedproductisdefectiveinmaterialorworkmanshipduringthewarrantyperiod,thenSunleaves,atitsoption,
willeitherrepairorreplacetheproduct.Innoeventshallthecostofrepairorreplacementexceedtheoriginalpurchaseprice.
HowtoObtainWarrantyService
Returnthisproductalongwiththeoriginalproofofpurchasetotheplaceofpurchaseinaccordancewithstorepolicy.Theoriginalproofof
purchaseMUSTaccompanytheBlueprint®product for this warranty to be valid.
HowStateLawApplies
Thiswarrantygivesyouspeciclegalrights,andyoumayalsohaveotherrightswhichvaryfromstatetostate.
Fortechnicalsupportandwarrantyinformation,calltoll-free888-464-9676oremail[email protected].
This manual suits for next models
11
Popular Portable Generator manuals by other brands

Shindaiwa
Shindaiwa DG150MM Owners and operation manual

Mosa
Mosa GE 17054 HBT Use and maintenance manual

Winco
Winco DR45F4/1 Installation & operator's manual

Harrison
Harrison Hydra-Gen Operation and installation guide

Briggs & Stratton
Briggs & Stratton 01810-0 Installation and start-up manual

Pulsar
Pulsar G465GN Operator's manual