Using and Maintenance:
Dimension:(mm)
IP65
ta
45 ℃
SP
IP65
ta
45 ℃
STREET LIGHT STREET LIGHT
SP
1.The luminaires shall be installed and maintained by qualified electrician and
wired in accordance with the latest IEC electrical regualations or national
requirements.
2.If the external flexible cable or cord of this luminaire is damaged, it shall be
replaced by the manufacturer or his service agent or a similar qualified person.
3.To prevent the risk of electric shock, turn off power supply before
installation. It is not permitted to connect the luminaire to high-voltage AC
supply line directly.
4.The luminaire is in accordance with GB7000:1,GB7000.10 and national
requirements.
5.The luminaire must be wired and grounded correctly.The input voltage and
current must meet the requirements. The supplier will not be responsible for
the consequences for inappropriate operation.
6.The light source contained in this luminaire shall only be replaced by the
manufacturer orhis service agent or a similar qualified person.
7. The external flexible cable or cord of this luminaire cannot be replaced; if the cord
isdamaged, the luminaire shall be destroyed.
8. This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the environment
or human health from uncontrolled waste disposal, recycle it responsibly to promote
the sustainable reuse of material resources. To return your used device, please use
the return and collection systems or contact the retailer where the product was
purchased. They can take this product for environmental safe recycling.
Installation Instruction
Watts(W) L(mm) W(mm) H(mm) Pole
diameter(mm)
80/100/120 623
H
W
L
200 93 Φ48,60
Model Watts
(W)
Current
(A)
Rated voltage
Frequency
CCT
(K) Ra PF Tc
(℃)
diameter
(mm)
Weight
(Kg)
0.38
3.2
SP3-80
SP3-100 0.48 220-240V~50/60HZ 3000/4000/5700
SP3-120 0.58
80
70 0.95 -25~45 Ф48,60
100
120
M8 hexagon socket plain end screws
Wiring diagram please refer to picture A
Picture A
M8 hexagon socket plain end screws
M12 waterproof connector
M6 hexagon socket cap screws
Fit for 55-60mm
diameter pole
M12 waterproof connector
Thread the input cable through t
he adaptor and the waterproof
connector
Step 1: Loosen the M8 hexagon socket plain end screw with
4mm hexagon wrench. Open the xture cover by
pressing the sharpnel.
Step 3: Input cable should be 3*1mm² cable according to IEC60245
Step 4: Fix the M8 hexagon socket plain end screw( the torque is 23N.M),
and then x the waterproof connector
Step 6:Loosen the M6 hexaon socket cap screws with 5mm hexagon wrench,
and adjust the tilting for -10°, -5°,0°,5°, and 10°.After adjustment,tighten
M6 hexagon scoket cap screws.
Step 5: Close the xture cover, and the
cover should be rmly xed on
the body by the sharpnel.
Step 2: Loosen the the waterproof connector with 16mm hexagon wrench,
thread supply line through the pole adaptor and the waterproof
connector.
Sharpnel