Broseley Hestia 5 EV-A5-CD1 Manual

Hestia EVA5/A7 Issue 1 30/06/2014 1
Installation & Operating
Instructions
Covering Models:
Hestia 5 & Hestia 7
(EV-A5-CD1 & EV-A7-CD1)
Wood Burning Stoves
Tested to EN 13240
These appliances must be installed and commissioned by a HETAS registered engineer

Hestia EVA5/A7 Issue 1 30/06/2014 2
Contents
Introduction 3
PackingList 3
Health&Safety 4
Specifications 5
Dimensions 6
Hearth Requirements & Clearances 7
Chimney Requirements 8
Combustion Air Requirements 9
Assembly 10
Commissioning/Handover 12
Stove Operation
Controls Layout 13
Controls Explained 14
AirwashSystem 14
AshPan 14
Recommended Fuels 15
Lighting the Stove
Kindling Stage 16
Burning Wood 17
Smoke Exempt Requirements 18
Lighting sequence (in smoke controlled areas) 19
WarningNotes 19
Maintenance
AshRemoval 20
ChimneyFires 20
Chimney Sweeping 20
General Stove Cleaning 20
GlassCleaning 20
Annual Stove Service 20
Prolonged Periods of Shut-down 20
Trouble-shooting 21
Commissioning Statement 22
SpareParts 23
ECDeclaration 25
Annual Service Record 27
Warranty 28

Hestia EVA5/A7 Issue 1 30/06/2014 3
Introduction
May we take this opportunity to thank you for choosing one of our stoves?
These appliances are designed to burn wood logs and wood derived fuels. It is essential
that your wood has been seasoned to ensure that it is sufficiently dry for burning. You can
determine the moisture content of your logs by using a digital moisture meter, your logs
need to be below 20% moisture content before they are considered dry enough for
burning.
Never burn wood that contains paint, glue or any other chemicals
See the section “Lighting the Stove” for further details.After reading this document, if there
is anything you are unsure about, please contact your dealer or our Technical Support
Department.
These instructions cover the basic principles to ensure the satisfactory installation of the
stove, although detail may need slight modification to suit particular local site conditions. In
all cases the installation must comply with current Building Regulations, Local Authority
By-laws and other specifications or regulations as they affect the installation of the stove.
It should be noted that the Building Regulations requirements may be met by adopting the
relevant recommendations given in British Standards BS 8303 and BS EN 15287-1 2007 +
A1 2010 as an alternative means to achieve an equivalent level of performance to that
obtained following the guidance given in Approved Document J.
Please note that it is a requirement under the Broseley Fires warranty system that the
installation of the stove is carried out by a Competent Person registered with a
Government approved Competent Persons Scheme. HETAS Ltd operate such a Scheme
and a listing of their Registered Competent Persons can be found on their website at
www.hetas.co.uk.
Packing List
1x Steel Bodied Stove 1x Spigot
1x Rear Firebrick (5 kW) 2x Rear Firebrick (7 kW)
2x Side Firebricks 1x Grate
1x Instruction Booklet 3x Lower Firebricks (surrounding the grate)
1x SteelAsh Pan
All parts will be inside the main stove body upon delivery. The spigot may be bolted to the
outside of the stove body.

Hestia EVA5/A7 Issue 1 30/06/2014 4
Health & Safety
Special care must be taken when installing the stove such that the requirements of the Health and
Safety at WorkAct are met.
Installation
This appliance MUST be installed and commissioned by a HETAS registered installer in England
and Wales and a fully qualified Heating Engineer in Scotland and Ireland.
Handling
Adequate facilities must be available for loading, unloading and site handling.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into contact with the
skin. In case of contact wash immediately with plenty of water.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of
installation then please seek specialist guidance and use appropriate protective equipment.
Metal Parts
When installing or servicing this stove care should be taken to avoid the possibility of personal
injury.
CO Alarms
Building regulations require that whenever a new or replacement fixed solid fuel or wood/biomass
appliance is installed in a dwelling an audible carbon monoxide alarm must be fitted in the same
room as the appliance. Further guidance on the installation of the carbon monoxide alarm is
available in BS EN 50292:2002 and from the alarm manufacturer’s instructions. Provision of an
alarm must not be considered a substitute for either installing the appliance correctly or ensuring
regular servicing and maintenance of the appliance and chimney system.
Fire Guards
When using the stove in situations where children, aged and/or infirm persons are present a
fireguard must be used to prevent accidental contact with the stove. The fireguard should be
manufactured in accordance with BS 8423:2002, Fireguards for use with solid fuel appliances.
Aerosol Sprays
Do not use an aerosol spray on or near the stove when it is alight.
Stove Surfaces
It is important to note that all surfaces of the stove will become extremely hot during operation, it is
therefore highly recommended that no surface or control is touched without appropriate heat proof
gloves.

Hestia EVA5/A7 Issue 1 30/06/2014 5
Specifications
In the UK these stoves have been approved by HETAS Ltd as intermittent heating
appliances for burning wood logs only.
This product is designed and tested for intermittent use.
European standards need to be complied with when installing this
appliance.
Hestia 5 (EV-A5-CD1) Hestia 7 (EV-A7-CD1)
Nominal Heat Output
(Wood) to Room kW 57
Efficiency % 77.8 76.6
Weight Kg 42 53
Flue Diameter mm 125 125
Flue Diameter Inches 5 5
Flue Draft Min Pa 12 12
Flue Draft Max Pa 18 18
Operating Flue Temp °C 257 213
Flue Gas Mass Flow G/S 4.6 9.2
Wood consumption Kg/Hr 0.96 1.3
This manual suits for next models
1
Table of contents