Firenzo Viking AG User manual

Please read this booklet and keep for future reference for the safe
installation and operation of your:
Viking ag
WET
WETWET
WET
AG
= Clean Air
FREESTANDING WOODBURNER
All installations must be in accordance
with these instructions. Consult
with the building authority having
jurisdiction to determine the need for
a permit prior to commencing the installation.
Failure to follow these instructions may also
void your fire insurance and warranty.

Viking AG Wet
2
Please leave these instructions with owner when installation is complete.
INDEX
Page No: Item No: Topic:
1 Warnings
4 2 Installation Responsibilities
4 Floor Protector Requirements
5 4 Installation Clearances
6 5 Assembly Instructions
7 6 Wetback
8 7 Flue Installation
9 Minimum Height of Flue System
Exit
Edited 4/ / 010

Viking AG Wet
1. WARNINGS
THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL
TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS.
The Viking AG is tested to N.Z. Standards AS/NZS 2918:2001.
If this heater is incorrectly installed a house fire may result. For your safety follow the
installation instructions carefully.
Do NOT connect the heater to a chimney serving another appliance.
Although the exterior of the heater may appear cool, contact with the unit may cause
burns, warn children and others of the possibility of injury should they touch the
heater.
Do NOT dry clothing or unseasoned wood directly in contact with the heater.
Keep all household combustible materials at least 600mm away from front of the
heater. This includes clothing, furniture, wood, newspaper, plastic, matches, etc.
DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY
OF THIS APPLIANCE WHEN IT IS OPERATING.
Use caution when reloading with fuel. Do NOT attempt to load fuel into the heater
when the fire inside the stove is at or near its peak.
Do NOT burn large quantities of paper or combustible material that would create an
extremely hot/quick fire.
Do NOT burn highly coloured paper or brochures (junk mail).
USE ONLY DRY WOOD. AVOID BURNING WET OR GREEN WOOD.
THE USE OF SOME TYPES OF PRESERVATIVE TREATED WOOD AS A FUEL
CAN BE HAZARDOUS.
TIMBER TREATED WITH COPPER CHROMIUM AND ARSENIC TYPE
PRESERVATIVES WILL LEAVE TOXIC RESIDUES IN THE ASH, FIREBOX OR
WITHIN THE FLUE, TIMBER OFFCUTS FROM BUILDING CONSTRUCTION
WILL OFTEN CONTAIN BORIC SALTS. THE COMBUSTION OF THIS
MATERIAL OVER PROLONGED PERIODS CAN PRODUCE ADVERSE
EFFECTS ON REFACTORY LINING IN SOLID FUEL APPLIANCES. EMISSION
OF POISONOUS GASES CAN ALSO BE EXPERIENCED WITH THE BURNING
OF TREATED WOOD.
Driftwood with salt content will also cause rapid deterioration of the heater and should
not be used.

Viking AG Wet
4
2. INSTALLATION RESPONSIBILITIES
WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED
IN ACCORDANCE WITH AS NZ 2918 AND THE APPROPRIATE
REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY IS
CONSIDERED
TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE
WITH AS NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM
DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION
OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE
SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE
CONSULTED IN THE FIRST INSTANCE.
Strict adherence to these instructions will meet these standards.
Any variation from these installation instructions or any doubt about them must be
checked against the requirements of the Standards.
Please leave this manual with the owner when installation is complete.
3. FLOOR PROTECTOR REQUIREMENTS
The heater should always be installed on top of its base due to high temperatures
sustained over long periods. The base must be anchored to both the floor protector and
the floor for seismic restraint. Anchor points are provided in the base.
If the heater is installed on or within 500mm of a heat sensitive floor,
then an ash
floor protector using a minimum of 6mm thick tiles will be required.
This
floor protector shall extend under the appliance and not less than 00mm beyond the
front of the fuel loading or ash removal openings. The width of the floor protector
shall be not less than the width of the appliance, and shall extend not less than 200mm
from each side of the fuel loading or ash removal openings unless it forms an abutment
with a wall or heat shield at a lesser distance.
Where the floor protector consists of a number of components, it shall include a
continuous layer of heat-resistant material extending under the appliance to the
perimeter of the floor protector. All joints shall be fixed to prevent accidental
separation, and shall be sealed to prevent any spilt ash or embers contacting any heat
sensitive material.

Viking AG Wet
5
4. INSTALLATION CLEARANCES
Firebox Size: Height 40 mm
Width 20 mm
Depth 500 mm
Flue Size: 150mm
Heating Area approx 200sqm
CLEARANCES
A B C D E F G H J K L M N O
WITH FLUE
SHIELD
100 320 300 120 50 260 590 350 780 1040 1280 1060 780 410
Clearances are shown with an ash floor protector using 6mm ceramic tiles