PD100 Display
Quick Start Guide
➢Use the RJ45-JST8 cable (in the product package) to connect
the PD100 display to the PanL Hub port. The Cable can reach
a maximum length of 100 meters if needed. The cable has an
RJ45 plug. Therefore, note that an RJ45 socket to RJ45 socket
adapter needs to be used if the extension cable is a plug-to-
plug type such as an Ethernet patch cable.
➢A PanL Hub port can only be connected to one PD100 display
at a time; Daisy chaining is not applicable.
➢An RS485 terminator is built into the PD100 display and
enabled.
PD100 allows different mounting options:
1. Wall Mount
2. Electrical Junction Box Mount
3. Glass Mount
➢ID switch on the back of the displays can be configured for
unique settings or left as factory default. Factory default is 0.
➢Use a Philips head screwdriver to set a unique number
between 0-7 (8- 9 are reserved).
Product Features
PSL Version
PRM Version
1
Ambient Light Sensor - Automatic screen brightness
control
2
Time of Flight Sensor - Reserved for Close Object
detection
3
Buzzer
4
Status indicator LED Strips - Refer to the LED Status
Indicator section for more details (PRM Version only)
Display Installation
Mounting
ID Switch Configuration
Please visit http://brtsys.com/warranty or scan the QR code
for warranty registration with the UUID and Product Key
below:
STICKER AREA
Glass
Double Sided Tape
Cover Sheet
(Back of Glass)
4. VESA Mount
Mounting
PD100 Display
Quick Start Guide
Status
LED Color (Normal Mode)
LED Color (Failsafe Mode)
Booting Up
Red
Red
Boot Success
Cyan
Red (Blink at 2Hz)
Lost Link to Hub
Orange
Red (Blink at 2Hz)
Communication Error
Red (Blink at 2Hz)
While communicating with Hub
NA
NA
Red (Blink at 2Hz)
Waiting for Recovery
NA
NA
Red <-> Cyan at 2Hz
Recovery in Progress
NA
NA
Red <-> Orange at 2Hz
Recovery Done
NA
NA
Cyan (Blink at 2Hz)
Waiting for Configuration
Orange (Blink at 2Hz)
NA
NA
License Expiry
Red
NA
NA
Note: PD100 enters Normal Mode when there are no failures; on the other hand, it enters FailSafe Mode if there are any failures. As an example, PD100 enters
FailSafe mode if an application image cannot be loaded. Use the application recovery feature to recover in this case.
The LED indicator at the side of the PD100 Display shows different display status as detailed in the table below -
Device Start up Animation/Image After Power Up
PD100 will display the following startup animation/image after connecting to the PanL Hub and powering ON. The LEDs on the PRM version will blink.
PSL Version
PRM Version
LED Status Indicator
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a building installation. This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be d etermined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
FCC Radiation Exposure Statement
This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This
equipment must not be co-located or operating in conjunction with any other antenna or transmitter.
FCC Statement
PD100 Display
Quick Start Guide

Popular Monitor manuals by other brands

Iiyama ProLite T2454MSC-B1AG user manual

Iiyama

Iiyama ProLite T2454MSC-B1AG user manual

LG Flatron L246WP Specifications

LG

LG Flatron L246WP Specifications

Philips 200P6 Declaration of conformity

Philips

Philips 200P6 Declaration of conformity

Asus VG27A Series user guide

Asus

Asus VG27A Series user guide

Philips 170B4BB Service manual

Philips

Philips 170B4BB Service manual

Philips 150T4FS user manual

Philips

Philips 150T4FS user manual

LG M2343A Service manual

LG

LG M2343A Service manual

Samsung WA65C user manual

Samsung

Samsung WA65C user manual

Transvideo Stargate Series Operator's manual

Transvideo

Transvideo Stargate Series Operator's manual

Philips 200V4Q user manual

Philips

Philips 200V4Q user manual

Philips Brillince 272P7 user manual

Philips

Philips Brillince 272P7 user manual

Sun Microsystems WDZF user guide

Sun Microsystems

Sun Microsystems WDZF user guide

Weldex WDL-1700MR Owner's instructions

Weldex

Weldex WDL-1700MR Owner's instructions

CCTV EX-17LBE user manual

CCTV

CCTV EX-17LBE user manual

Barco ILite 6 Service manual

Barco

Barco ILite 6 Service manual

Omega Engineering DP1632 Series user guide

Omega Engineering

Omega Engineering DP1632 Series user guide

Pioneer PDP-505PE quick start guide

Pioneer

Pioneer PDP-505PE quick start guide

Lenovo Y27qf-30 user guide

Lenovo

Lenovo Y27qf-30 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.