Butterfly Energy Systems BESM-24AO23 User manual

Thank you for choosing BuƩerfly Energy Systems, please review installaƟon guide
before installaƟon and retain for future reference.
BuƩerfly Energy Systems
Air Intelligence Series
InstallaƟon Guide
(For Outdoor MulƟ-Head Systems)
BESM-24AO23


1
2
3
4
4
5
7
7
8
8
9
Technical Data
Electrical Connections
Installing The Outdoor Unit
Maintenance
Installation Dimension Diagram
Check After Installation
Bleeding
Conformity And Range
The Instructions Before Use
Name of Parts
Outdoor Unit Working Temperature Range
GENERAL
INSTALLER INFORMATION
CONTENTS
1
In line with the company’s policy of continual product improvement, the aesthetic and dimensional characteristics,
technical data and accessories of this appliance may be changed without notice.
CONFORMITY AND RANGE GENERAL INFORMATION
GENERAL INFORMATION
Please read this owner's manual carefully before operating the unit and keep it carefully for consultation.
Product diagrams in this manual may appear different from your actual model.
.
The air conditioner you have purchased conforms with the following American Directives
UL1995:
Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every
possible condition and situation. As with any electrical household appliance, common sense and caution are
therefore always recommended for installation, operation and maintenance.

2
GENERAL INFORMATION
fire or electrical shock when operating an electrical appliance including
the following:
2.This appliance is hot when in use. To avoid burns,do not touch bare
skin on hot surfaces. Keep combustible materials such as clothing,
pillows, bedding, and curtains away from the front of the appliance.
And keep objects at least 1 meter away from the sides of the appliance.
3.This appliance is cold when in use. Be mindful of the coldair blowing
from the front. Arrange household items such as furniture and plants
accordingly.
4.This appliance is moving when in operation. To avoid injury, do not touch
moving pieces or apply force to moving pieces in any manner.
5.Do not insert or allow foreign objects to enter any ventilation or exhaust
opening. This many cause injury, electrical shock, fire or damage to the
appliance.
6.To prevent a possible fire, do not block air intakes or exhaust in any
manner.
7.Do not stand or rest any object on top of the appliance.
8.Do not operate if there is any damage to the appliance.
9.The installation, repairs, and modifications to the appliance are only to
be performed by a trained technician.
10.Children, persons with reduced mental, sensory, or physical capabilities,
or lack of knowledge and experience should not operate this appliance,
unless they have been given supervision or instruction.
11.Use this appliance only as described in the manual.Any otheruse not
recommended by the manufacture may cause fire, electricshock, or
injury to persons.
1.Read all instructions before using the appliance.
IMPORTANT REMINDERS
Basic precautions should be taken to reduce the risk of injury to person,

Note:the above figures are only intended to be a simple
diagram of the appliance and may not correspond to
the appearance of the units that have been purchased.
OUTDOOR UNIT
No. Description
1Air outlet grille
2Valve
The temperature of refrigerant circuit will be high,please keep the
interconnection cable away from the copper tube.
Be sure to cut off the power supply before cleaning the air conditioner;
otherwise electric shock might happen.
Wetting of air conditioner may cause the risk of electric shock. Make
sure not to wash your air conditioner in any case.
Volatile liquids such as thinner or gasoline will cause damage to the
appearance of air conditioner. (Only use soft dry cloth moist cloth clean
the air conditioner cabinet).
Collection of such waste separately for special treatment
is necessary.
or its service agent or a similarly qualified person in order to avoid a hazard.
3
GENERAL INFORMATION
1
2
BESM-24AO23
NAME OF PARTS
Warning
If the supply cable is damaged, it must be replaced by the manufacturer
Do not dispose this product as unsorted municipal waste.

Maximumcooling
Minimum cooling
Maximumheating
Minimum heating
OutdoorsideDB/WB( )
48/-
-5/-
27/-
-15/-
OUTDOOR UNIT WORKING TEMPERATURE RANGE GENERALINFORMATION
4
TECHNICALDATA GENERAL INFORMATION
P
L
A
B
H
Minimum power cable section 40
4.0 g
mm
mm
mm
mm
mm
L
P
H
A
B
Fuse or air switch
2200
890
362
700
560
368
MODE BESM-24AO23
208/230V/1~60Hz
mm2
Refrigerant gas(R410A)
Electrical data
Electricity supply
Size and clearance
c

2
.
3.
4.
5.
Remove the cable clamp, connect the connection cable
and power cable with the terminal at the row of connection
and fix the connection. The fitting line distributing must be
consistent with the indoor unit terminal of line bank.
1.
Remove the handle at the right side plate of the
outdoor unit (ten screw).
Wiring should meet that of indoor unit.
Fix power connection wire by wire clamp.
Ensure wire has been fixed well.
Install the handle.
ELECTRICAL CONNECTIONS INSTALLER
BESM-24AO23
Wrong wire connection may cause malfunction of some
electric components.After fixing cable, ensure that
An all-pole disconnection switch having a contact
separation of at least 3mm in all pole should be
connected in fixed wiring.
leads between connection to fixed point have some space.
The connection pipes and the connectiong wirings of
the unit A ,unit B and unit C must be corresponding to each
other respective.
The appliance shall be installed in accordance with
national wiring regulations.
Do not install the outdoor unit where it is exposed
to the sunlight.
Note: the above figures are only intended to be a simple
ehtotdnopserroctonyamdnaecnailppaehtfomargaid
appearance of the units that have been purchased.
To the power supply
To unit B
To unit A
cable
connection
power connection
cable
cable
To unit C
connection
cable
Outdoor unit
Indoor unit
L1 L2
L1
L1
L2
L2
Power
cable
A
B
C
D
connection cable
connection cable
connection cable
connection cable
1) The power cable should be put in from the hole under
connection cable cover.
2) If connecting with two indoor units, the connection cable
should be put in from hole A and hole B.
3) If connecting with three indoor units, the connection cable
should be put in from hole A , B and C.
4) If connecting with four indoor units, the connection cable
should be put in from hole A, B , C and D.
All power cables and connection cables must be protected with conduits.
5

HANDLING USER
After having removed the packaging, check that the
contents are intact and complete.
The outdoor unit must always be kept upright.
Handling must be done by suitably equipped qualified
technical personnel using equipment that is for suitable
the weight of the appliance .
6

Vacuum pump
INSTALLER
Humid air left inside the refrigerant circuit cancausecom-
pressor malfunction. After having connected the indoor
and outdoor units, bleed the air and humidity from the
refrigerant circuit using a vacuum pump.
(1) Unscrew and remove the caps from the 2-way and 3-
way valves.
(2) Unscrew and remove the cap from the service valve.
(3) Connect the vacuum pump hose to the service valve.
(4) Operate the vacuum pump for 10-15 minutes until an
absolute vacuum of 10 mm Hg has been reached.
(5) With the vacuum pump still in operation, close the
low-pressure knob on the vacuum pump coupling.Stop
the vacuum pump.
(6) Open the 2-way valve by 1/4 turn and then close it
after 10 seconds.Check allthe joints for leaks using
liquid soap or an electronic leak device.
(7) Turn the body of the 2-way and 3-way valves. Discon-
nect the vacuum pump hose.
(8) Replace and tighten all the caps on the valves.
BLEEDING INSTALLER
INDOOR
UNIT
Vacuum pump Vacuum pump
Connect to the
indoor unit
Location
Twisting moment (N.m)
35-40
60-65
45-50
70-75
ĭ2
ĭ9
Diameter (mm)
ĭ.52
ĭ6
15-20
ĭ
(9) If the specification of outdoor unit gas valve is 3/8",
but curstomer needs to install 1/2"indoor unit so that
it is need to use a “pipe joint subassembly” (Code 06643008)
to make a conversion joint with outdoor unit gas valve and
connection pipe, as show in following.
conversion joint
Refrigerant fluid direction of flow
3-way valve
2-way valve
Service
inlet
(2)Turn
(8) Secure
(7)Turn to open fully
(2)Turn
(8) Secure
Valve cap
(6) Open by 1/4 turn
(7)Turn to open fully
(2)Turn
(8) Secure
Valve cap
Drain-water hole
Bottom frame
Drain plug
Hose (available commercially,
inner dia. 16mm)
Drain connecter
Use bolts to secure the unit to a flat, solid floor.
When mounting the unit on a wall or the roof, make
sure the support is firmly secured so that it cannot
move in the event of intense vibrations or a strong
wind.
Do not install the outdoor unit in pits or air vents
Installing the pipes
Install the drain fitting and the drain hose(for
model with heat pump only)
Condensation is produced and flows from the outdoor unit
when the appliance is operating in the heating mode. In order
not to disturb neighbours and to respect the environment,
install a drain fitting and a drain hose to channel the conden-
sate water. Install the drain fitting and rubber washer on the
outdoor unit chassis and connect a drain hose to it as shown
in the figure.
Use suitable connecting pipes and equipment for the
refrigerant R410A.
Wrap all the refrigerant pipes and joints.
Tighten the connections using two wrenches working
in opposite directions.
Caution: Installation Must be Performed in Accordance
with the NEC/CEC by Authorized Personnel Only
Models(m) 18K 24/30K
Max. connection pipe length 20 70
Max. connection pipe length(Simple
one indoor unit) 10 20
The refrigerant pipes must not exceed the maximum
heights 5m(18K) or 10m(24K&30K).
INSTALLING THE OUTDOOR UNIT
7

MAINTENANCE INSTALLER
INSTALLATION DIMENSION DIAGRAM
The installation must be done by trained and qualified service personnel with reliability according to this manual.
This is just the schematic plan, please refer to the actual product.
BESM-24AO23
30cm
(Air inlet side)
or above
50cm
or above
Spacetothewall
200cm
(Air outlet side)
or above
30cm
Space to the cover
or above
or more
Space to the cover
50cm
INSTALLER
Use suitable instruments for the refrigerant R410A.
Do not use any other refrigerant than R410A.
Do not use mineral oils to clean the unit.
Contact service center before installation to avoid the malfunction due to unprofessional installation.
When picking up and moving the units, you must be guided by trained and qualified person.
Ensure that the recommended space is left around the appliance .
8

INSTALLER
CHECK AFTER INSTALLATION
Check Items Problems Owing to Improper Installation
Is the installation reliable? The unit may drop, vibrate or make noises
Has the gas leakage been checked? May cause unsatisfactory cooling (heating)
effect
Is the thermal insulation of the unit
sufficient?
May cause condensation and water dropping
Is the drainage smooth? May cause condensation and water dropping
Does the power supply voltage accord
with the rated voltage specified on the
nameplate?
The unit may bread down or the components
may be burned out
Are the lines and pipelines correctly
installed?
The unit may bread down or the components
may be burned out
Has the unit been safely grounded? Risk of electrical leakage
Are the models of lines in conformity
with requirements?
The unit may bread down or the components
may be burned out
Are there any obstacles near the air
inlet and outlet of the indoor and outdoor
units?
The unit may bread down or the components
may be burned out
Have the length of refrigerating pipe
and refrigerant charge amount been
recorded?
It is not easy to decide the charge amount
of refrigerant.
9

66129915030
Table of contents
Popular Air Conditioner manuals by other brands

Retro Aire
Retro Aire R30C Installation, operation & maintenance manual

American Standard
American Standard 4A6V8024A1000B Service facts

Daikin
Daikin H-Series engineering data

Maplin
Maplin A75TB user manual

Haier
Haier HDU-42HT03/H Operating & installation manual

Sears
Sears Kenmore P/N93SR-D02 owner's manual