Carel humiFog Touch User manual

NO POWER
& SIGNAL
CABLES
TOGETHER
READ CAREFULLY IN THE TEXT!
ENG
INSTALLATION MANUAL
humiFog Touch
pumping station
humiFog Touch
+0300113EN - ENG
Up to date version available on
www.carel.com


3
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
GENERAL WARNINGS
FAILURE TO CAREFULLY HEED THE WARNINGS SHOWN IN THIS MAN-
UAL COULD LEAD TO FIRE OR EXPLOSION AND CONSEQUENT DAM-
AGE TO PROPERTY, INJURY OR DEATH.
CAREL Industries humidiers are advanced products, whose operation is
specied in the technical documentation supplied with the product or
can be downloaded, even prior to purchase, from the website www.carel.
com. Each CAREL product, in relation to its advanced level of technology,
requires setup/conguration/programming to be able to operate in the
best possible way for the specic application. Failure to complete such
operations, which are required/indicated in the user manual, may cause
the nal product to malfunction; CAREL accepts no liability in such cases.
The customer (manufacturer, developer or installer of the nal equipment)
accepts all liability and risk relating to the conguration of the product in
order to reach the expected results in relation to the specic nal instal-
lation and/or equipment. CAREL may, based on prior agreements, act as
a consultant for the installation/commissioning/use of the unit, however
in no case does it accept liability for the correct operation of the humid-
ier and the nal installation if the warnings or suggestions provided in
this manual or in other product technical documents are not heeded. In
particular, as well as observing the above warnings and suggestions, the
following warnings must be observed for correct use of the product:
ELECTRIC SHOCK HAZARD: the humidier contains live electrical com-
ponents.Disconnect the mains power supply before accessing inside
parts or during maintenance and installation.
WATER LEAK HAZARD: the humidier automatically and constantly lls/
drains certain quantities of water. Malfunctions in the connections or in
the humidier may cause leaks.
CAUTION
The installation of the product must include an earth connection, using
the special yellow-green terminal available in the humidier.
Caution:
• Disconnect the appliance from the mains power supply before access-
ing any internal parts.
• Environmental and power supply conditions must conform to the val-
ues specied on the product rating labels.
• The product is designed exclusively to humidify rooms either directly or
through distribution systems (ducts).
• Only qualied personnel who are aware of the necessary precautions
and able to perform the required operations correctly may install, oper-
ate or carry out technical service on the product.
• Only water with the characteristics indicated in this manual must be
used to produce the spray.
• All operations on the product must be carried out according to the
instructions provided in this manual and on the labels applied to the
product. Any uses or modications that are not authorised by the manu-
facturer are considered improper. CAREL declines all liability for any such
unauthorised use.
• Do not attempt to open the appliance in any way other than described
in the manual.
• Observe the standards in force in the place where the humidier is in-
stalled.
• The appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of expe-
rience and knowledge, unless they have been given supervision or in-
struction concerning use of the appliance by a person responsible for
their safety.
• Do not install and use the product near objects that may be damaged
when in contact with water (or condensate). CAREL declines all liability
for direct or indirect damage following water leaks from the humidier.
• Do not use corrosive chemicals, solvents or aggressive detergents to
clean the inside and outside parts of the humidier, unless specically
indicated in the user manual.
• Do not drop, hit or shake the humidier, as the inside parts and the lin-
ings may be irreparably damaged,
CAREL adopts a policy of continual development. Consequently, CAREL
reserves the right to make changes and improvements to any product
described in this document without prior warning. The technical speci-
cations shown in the manual may be changed without prior warning.
The liability of CAREL in relation to its products is specied in the CAREL
general contract conditions, published on the website www.carel.com
and/or by specic agreements with customers; specically, to the extent
where allowed by applicable legislation, in no case will CAREL, its employ-
ees or subsidiaries/aliates be liable for any lost earnings or sales, losses of
data and information, costs of replacement goods or services, damage to
things or people, downtime or any direct, indirect, incidental, actual, puni-
tive, exemplary, special or consequential damage of any kind whatsoever,
whether contractual, extra-contractual or due to negligence, or any other
liabilities deriving from the installation or use of the product, even if CAREL
or its subsidiaries/aliates are warned of the possibility of such damage.
DISPOSAL
Fig. 1 Fig. 2
PLEASE READ AND KEEP.
WITH REFERENCE TO EUROPEAN UNION DIRECTIVE 2012/19/EU IS
SUED ON 4 JULY 2012 AND RELATED NATIONAL LEGISLATION, PLEASE
NOTE THAT:
• Waste Electrical and Electronic Equipment (WEEE) cannot be disposed
of as municipal waste but must be collected separately so as to allow
subsequent recycling, treatment or disposal, as required by law;
• users are required to take Electrical and Electronic Equipment (EEE) at
end-of-life, complete with all essential components, to the WEEE collec-
tion centres identied by local authorities. The directive also provides
for the possibility to return the equipment to the distributor or retailer
at end-of-life if purchasing equivalent new equipment, on a one-to-one
basis, or one-to-zero for equipment less than 25 cm on their longest
side;
• the equipment may contain hazardous substances: the improper use or
incorrect disposal of such may have negative eects on human health
and on the environment;
• the symbol (crossed-out wheeled bin, see Figure 1), if shown on the
product or on the packaging, indicates that the equipment must be dis-
posed of separately at end-of-life;
• if at end-of-life the EEE contains a battery (Figure 2), this must be re-
moved following the instructions provided in the user manual before
disposing of the equipment. Used batteries must be taken to appropri-
ate waste collection centres as required by local regulations;
• in the event of illegal disposal of electrical and electronic waste, the
penalties are specied by local waste disposal legislation.
Warranty on materials: 2 years (from production date, excluding consum-
ables).
Approval: the quality and safety of CAREL products are guaranteed by the
ISO 9001 certied design and production system, as well as the
, and marks.
Avvertenze

4
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221

5
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
Index
1. PURPOSE OF THE MANUAL ..................................... 7
2. HOW TO READ THE MANUAL .................................. 7
3. General safety information and instructions ...... 8
3.1 Intended use........................................................................................................8
3.2 General safety instructions .........................................................................8
3.3 Personal protective equipment...............................................................9
4. Introduction............................................................. 10
4.1 Components..................................................................................................... 10
4.2 Air handling unit (AHU)..............................................................................10
4.3 Pumping station............................................................................................. 13
4.4 Opening the packaging ............................................................................ 13
4.5 Positioning.........................................................................................................14
4.6 Opening...............................................................................................................14
4.7 Identication.....................................................................................................14
4.8 Structure..............................................................................................................15
4.9 Accessories ........................................................................................................15
5. Installation notes .................................................... 18
5.1 Network connection....................................................................................18
5.2 Distribution system ...................................................................................... 19
5.3 Functional diagrams - room....................................................................19
5.4 Backup and rotation.....................................................................................21
6. Installation ............................................................... 22
6.1 Water connections........................................................................................22
6.2 Feedwater........................................................................................................... 23
6.3 Electrical connections.................................................................................23
6.4 Control connections....................................................................................24
6.5 Solenoid valve connections.................................................................... 25
6.6 Inputs and outputs.......................................................................................25
7. Maintenance ............................................................ 27
7.1 Routine maintenance ................................................................................. 27
7.2 One-o service and repairs..................................................................... 27
7.3 Pump maintenance......................................................................................28
8. Technical data.......................................................... 29
8.1 Technical specications............................................................................. 29
8.2 Terminal tightening torque.....................................................................29
8.3 Fuse chart ...........................................................................................................29
9. Checklist ................................................................... 30
10. ANNEXES .................................................................. 31
Annex A: Wiring diagrams...................................................................................31
Annex B: Accessories and spare parts kits.................................................33
Indice


7
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
This manual contains instructions for the installation, use and maintenance of the models of humiFog unit manufactured by:
CAREL INDUSTRIES
Via dell’Industria, 11, 35020
Brugine - Padova (Italy)
Tel. (+39) 049.9716611 - Fax (+39) 049.9716600
e-mail: carel@carel.com - www.carel.com
1. PURPOSE OF THE MANUAL
The manual is divided into chapters and paragraphs. Each paragraph is a sub-level of the corresponding chapter. References to
headings or paragraphs are indicated by the abbreviation“Chap.” or “Par.” followed by the number.
Example:“Chap. 2”or “Par. 2.1”.
The gures in this manual are numbered consecutively according to the corresponding chapter, for example Figure 1.c is the
third gure in chapter one. References to the gures are indicated by the abbreviation “Fig.” followed by the number. Example:
“Fig. 1.c”.
The components shown in the gures are marked with numbers. A reference to component 1 in gure 2, chapter 3 will be indi-
cated as follows:“See 1 - Fig. 3.b”or simply “(1 - Fig. 3.b)”.
IMPORTANT
The gures shown in this manual are purely indicative. The actual components may vary from those illustrated. If in doubt,
contact an authorised service centre.
In addition to the instructions for installation, use and maintenance, this manual contains safety information that requires special
attention. This information is denoted by the symbols described below:
DANGER
Failure to comply with this warning will lead to an imminently hazardous situation which, if not avoided, will result in death
or serious injury.
WARNING
Failure to comply with this warning will lead to potentially hazardous situation which, if not avoided, could result in death
or serious injury.
CAUTION
Failure to comply with this warning will lead to a potentially hazardous situation which, if not avoided, may result in minor
or moderate injury.
IMPORTANT
Failure to comply with this warning will lead to a potentially hazardous situation which, if not avoided, could cause minor
damage to the unit.
Notice: provides supplementary information to the above safety instructions.
2. HOW TO READ THE MANUAL

8
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
3. GENERAL SAFETY INFORMATION AND
INSTRUCTIONS
3.1 Intended use
humiFog is a high pressure adiabatic humication system for humidity control and evaporative cooling. It can be used both to
condition the air in an AHU (air handling unit), and for direct humidication or cooling in rooms.
IMPORTANT: the product must only be used for its intended purpose, as envisaged by CAREL. CAREL declines all
liability, both contractual and extra-contractual, for any damage to people, animals or things due to installation, control or main-
tenance errors or improper use.
3.2 General safety instructions
When using products that require electricity and a source of high-pressure water, a number of fundamental safety rules need to
be observed, including:
• The appliance must not be used by children or people with reduced physical, sensory or mental capabilities, or people lacking
the necessary experience or knowledge or who are not familiar with the operating instructions.
• People without specic qualications and skills must not use the pumping station.
• People must not come into contact with the appliance if barefoot or any of the parts of their body are wet.
• No technical or cleaning operations are allowed until the appliance has been isolated from the power supply by moving the
main system switch to“o”and the main switch on the appliance to “OFF”.
• The safety and control devices must never be adjusted without the manufacturer’s authorisation.
• The pictograms and labels axed to the pumping station must not be removed. These must remain legible and the corre-
sponding instructions must be observed at all times. If they are no longer legible, they must be replaced with equivalent
pictograms or safety labels.
• The water connections must never be loosened during operation. Improperly secured pipes or hoses may detach without
warning, resulting in injury.
• Do not block or obstruct the water drain.
• Do not pull, disconnect or twist the electrical cables coming out of the appliance, even when this is disconnected from the
mains power supply.
• Never expose the appliance to the elements. It is designed for indoor use only.
• Do not dispose of the packaging material in the environment and keep it out of the reach of children, as it is a potential hazard.
It must be disposed of in accordance with current legislation.
• Do not activate the pumping station without it being adequately supplied with water.
• The customer is responsible for ensuring that the humidication system complies with local guidelines on occupational
health and safety and prevention of bacterial proliferation.
• In the event of water leaks, disconnect the pumping station from the power supply, shut o the water supply and promptly
notify CAREL’s Technical Service or other professionally qualied personnel.
• Periodically check that the water circuit operating pressure is above 1 bar and below than the maximum limit specied for the
appliance. Otherwise, contact CAREL’s Technical Service or other professionally qualied personnel.
• If the pumping station is not used for an extended period, the following operations need to be carried out:
- Turn the main switch on the appliance to“OFF”
- Turn the main system switch to“o”
- Close the system water taps
- Empty the system if there is the risk of freezing.
• This instruction manual is an integral part of the appliance and consequently must be kept with care and must ALWAYS
accompany the pumping station even if it is transferred to another owner or installed in another system. If damaged or loss,
another copy can be ordered from CAREL’s local Technical Service.
• Read this instruction manual read carefully to ensure proper and safe installation, operation and maintenance of the appli-
ance. The owner must be adequately informed and trained on how to use the appliance. Users must be familiar with all the
information needed for safe operation of the system.
• Before connecting the pumping station to the water and power supply, it can be exposed to temperatures between -10°C and
40°C. Once commissioned, it can be exposed to temperatures between 5°C and 40°C.
• Periodically check that the water drains are not blocked.

9
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
3.3 Personal protective equipment
DANGER: strictly follow the instructions provided in the manual.
Personal protective equipment (PPE) means any equipment intended to be worn and kept by workers in order to protect them-
selves against one or more risks likely to threaten their health or safety during work, as well as any device or accessory intended
for this purpose.
All PPE described in this manual are intended to protect personnel from health and safety risks.
Below is a list of personal protective equipment to be used and the procedures to be adopted to protect workers from the re-
sidual risks that exist during the various phases of the humidier’s life cycle.
GLOVES TO PROTECT AGAINST PHYSICAL ELEMENTS:
these must protect the person's hands against cuts, abrasion and heat.
NON-SLIP SAFETY FOOTWEAR: these must prevent falls on slippery surfaces and protect the person's feet from
impact, crushing and puncture wounds.
SAFETY HARD HAT: this must protect the person's head against bumps or material accidentally falling from above.
SAFETY GLASSES: these must protect the person's eyes from all risks due to contact with hazardous substances or
materials.
PROTECTIVE MASK: this protects the wearer’s respiratory tract against all risks associated with the inhalation of
dangerous substances.
PROTECTIVE CLOTHING: this guarantees the body adequate protection against thermal and chemical agents.
EARMUFFS: these must attenuate noises that would otherwise be harmful to the person's hearing.
INSTRUCTION MANUAL: this must be referred to whenever necessary, in order to avoid adopting unsafe proce-
dures.

10
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
4. INTRODUCTION
4.1 Components
• Pumping station, comprising the system pump and the electrical panel;
• zone electrical panel;
• distribution system and droplet separator for humidication in air handling units;
• blower unit for in-room humidication.
The range includes the pumping station in the humiFog multizone and humiFog multizone Touch versions, which dier in terms
of the components supplied, the accessories available and the dierent system conguration modes.
The system can comprise:
• single zone: 1 pumping station with 1 atomisation system;
• multizone: 1 pumping station that supplies up to 12 independent atomisation systems.
Notice:
• to connect the pumping station to the blowers, use the water circuit assemblies and electrical panels supplied separately by
Carel (see the list of accessories);
• to facilitate commissioning, plates already equipped with electrical connectors are available for simply and quickly connecting
the electrical panels to the solenoid valves on the distribution manifolds.
The following diagrams provide an overview of the systems that can be implemented.
4.2 Air handling unit (AHU)
Internal rack valves
1
10
6
7
8
9
3
5
4
2
Fig. 4.a
Ref. Description
1 Pumping station
2 Electrical cables
3 Distribution manifolds
4 Zone-electrial panel
5 Droplet separator
6 Drain trap
7 Open funnel drain (after droplet separator)
8 Open funnel drain (before droplet separator)
9 High pressure water line
10 Line drain valve
Tab. 4.a

11
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
Multizone
2
1
3
3
Fig. 4.b
Ref. Description
1 Pumping station
2 Ethernet cable
3 Zone electrical panel
Tab. 4.b
Notice: for the Ethernet connection from the pumping station to the zone electrical panels, see“Installation notes”.

12
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
4.2.1 Room
Single zone
Direct Box
Direct Box
1
5
3
Sensore
di umidità
Quadro
elettrico
di zona
4
2
Fig. 4.c
Multizone
Direct Box
Direct Box
1
2
6
5
Direct Box
Direct Box
Quadro
elettrico
di zona 2
Quadro
elettrico
di zona 1
Zona 1 Zona 2
Sensore
di umidità 1
Sensore
di umidità 2
3
4
Alimentazione
Fig. 4.d
Ref. Description
1 Pumping station
2 Directbox hydraulic
3 Blower unit
4 Zone electrical panel
5 Directbox electric
6 Ethernet cable
Tab. 4.c
Humidity
sensor
Zone
elecrical
panel
Zone
1- elecrical
panel Power supply
Zone
2- elecrical
panel
1-Humidity
sensor
2-Humidity
sensor
Zone 1 Zone 2

13
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
4.3 Pumping station
4.3.1 Part numbers
humiFog multizone Touch models
U A * * * * * 5 0 *
Range Flow-rate kg/h Model Power supply and approval Revision no. Customisation Pump type
UA:
humiFog
150: 150 kg/h 1: humiFog
multizone
Touch
2: 230 Vac 50/60 Hz, 1~, UL
U: 208 Vac 50/60 Hz, 1~, UL
M: 460 Vac 50/60 Hz, 3~, UL
5: Fifth
revision
0: Carel
0: Brass
300: 300 kg/h 1: Stainless steel
500: 500 kg/h 2: Silicone-free stain-
less steel
800: 800 kg/h
1K2: 1200 kg/h
Tab. 4.a
Notice: in accordance with the requirements of UL998 in the most recent edition.
4.3.2 Dimensions - inches
37.0
48.5
33
1
9
38.4
44.7
2
4
.
4
Fig. 4.e
4.3.3 Weight - lb
humiFog multizone Touch models Weight with/without packaging [lb]
UA150**500/UA150**501/UA150**502 229/ 207
UA300**500/UA300**501/UA300**502 231/ 209
UA500**500/UA500**501/UA500**502 253/ 231
UA800**500/UA800**501/UA800**502 280/ 258
UA1K2**500/UA1K2**501/UA1K2**502 278/ 256
Tab. 4.b
4.4 Opening the packaging
• check that the packaging is intact upon delivery and notify the carrier immediately, in writing, of any damage that may be due
to improper or negligent transport;
• move the pallet with the pumping station to the installation site before removing it from the packaging, lifting the box using
suitable lifting/handling equipment;
• place it near the position where it will be installed;
• remove the packaging.
IMPORTANT: make sure the load does not swing when lifting it.
4.4.4 Material supplied
After opening the packaging and removing the front panel, check that
the following are present:
• 1 cable gland (A) for the power supply cable;
• 1 cable gland (B) for the electric cable coming out of the pumping
station;
• 1 key (C) for opening the panels,
• NPT ttings (D)
• installation manual
A B C D
Fig. 4.f

14
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
4.5 Positioning
Install the pumping station on the oor, indoors, so as to ensure:
• accessibility of the display and that this can be clearly read;
• opening of the front panel;
• easy access to the internal parts;
• connection of the water supply and drain lines;
• power and control electrical connections.
min
19 in
min
19 in
min
19 in
min
39 in
Entrata
ARIA
Uscita
ARIA
Fig. 4.g
Notice:
• check with a spirit level that the
unit is placed on a horizontal
surface;
• if the unit is positioned up
against a wall, do not place
any objects on it that block the
cooling air.
4.6 Opening
Open the panels using the key supplied (gure) to access the electrical panel (A) and the water circuit section (B).
APERTO
APERTO
A
B
Fig. 4.h
4.7 Identication
The pumping station can be identied by the rating plate located inside the electrical panel.
TYPE
Pnom kW
Qnom kW
G20(nat.gas)
G25(nat.gas)
Vac
Hz
PH
kW
kg / h
IP
NOx cl
Date
CODE
IP
Date
Part No.
Serial No.
Rev.
MADE IN ...
CAREL INDUSTRIES
Via dell'Industria, 11, 35020 Brugine
(Padova) Italy
Fig. 4.i
IMPORTANT: tampering, removal or absence of the rating plate or anything else that does not allow certain identi-
cation of the product will make any installation or maintenance operations dicult and will void the manufacturer’s warranty.
Inlet
AIR
Outlet
AIR
min min
min
min
OPEN
OPEN

15
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
4.8 Structure
3
4
5
6
7
8
9
14
15
16
17
18
10
19
21
23
20
11
2
1
22
13
24
25
1
12
Fig. 4.j
Ref. Description
1 Opening for the power cable
2 On/O switch
3 Inlet pressure gauge
4 Low pressure probe
5 Water inlet
6 Supply solenoid valve
7 Cooling fan
8 High pressure switch
9 Temperature probe
10 Thermostat
11 User terminal
12 Electrical panel
13 Openings for cable glands
14 High pressure outlet pressure gauge
15 High pressure control valve
16 High pressure probe
17 Piston pump
18 Elastic joint (internal)
19 Water outlet
20 Cabinet drain solenoid valve
21 Cabinet drain
22 Oil collection tank drain
23 Pressure relief valve
24 Conductivity meter
25 Damper
Tab. 4.c
4.9 Accessories
Zone electrical panel
Electrical panel to be connected to the pumping station for managing multizone in-room or duct systems.
Fig. 4.k
Ref. Description
UA000SU500 208 V 60 Hz electrical panel
UA000S2500 230 V 60 Hz electrical panel
Tab. 4.d

16
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
4.9.1 In-room humidication
directBOX hydraulic
Water circuit assembly for interfacing the pumping station with the blowers for in-room humidication. It contains the solenoid
valves for pressurising 1/2 water lines (zone/step). See technical leaet +050001828.
Fig. 4.l
Ref. Description
UAKDLASV10 directBOX hydraulic for managing 1 zone/step
UAKDLASV20 directBOX hydraulic for managing 2 zones/steps
Tab. 4.e
directBOX electric
Electrical panel for interfacing the pumping station with the blowers for in-room humidication. It receives the control signal
for the ll and drain valve (1 or 2 zones/steps) and relays this to the directBOX hydraulic to actuate the valves. At the same time
it controls the blower fans, which are only activated when there is a humidication request. See technical leaet +050001828.
Fig. 4.m
Ref. Description
UAKDLAEL10 directBOX electric for managing 1 zone/step
UAKDLAEL20 directBOX electric for managing 2 zones/steps
Tab. 4.f
Blower unit
The blowers are positioned directly in the room to be humidied and cooled. They dier in terms of ow rate and direction of
spray. They are connected to the pumping station via the directBOX hydraulic and directBOX electric accessories. See technical
leaet +050001852.
Fig. 4.n
Ref. Description
DLA0****00 Blower with 2 nozzles, 1.45 l/h, 230 V 50 Hz, front delivery
Tab. 4.g
Notice:
• X: 2/4/8 = 2/4/8 nozzles
• P: D/U = 230V - 50 Hz/120V - 60 Hz power supply
• T: F/B = delivery from front/front and rear
• Y: 0/1/2 = 1.45/2.80/4.00 l/h.

17
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
Manifolds with nozzles
The distribution system is designed according to the specic application and comprising manifolds, solenoid valves, nozzles,
pipes and ttings.
Fig. 4.o
4.9.2 Ducted humidication
Racks
The distribution system is designed according to the specic application and comprising manifolds with nozzles and xing
frame in the duct, available in the fully- or partially-assembled versions.
Fig. 4.p
The racks are available with:
• horizontal or vertical collectors;
• solenoid valves tted on the rack or outside of the air handling unit.
Droplet separator
Frame with stainless steel or berglass modules.
Notice: the modules are sized according to the specic application.
Fig. 4.q

18
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
5. INSTALLATION NOTES
5.1 Network connection
See the technical data table for the specications of the connection cables.
5.1.1 Zone panel connection
The connection is made using an Ethernet cable from the pumping station to the zone panels, as shown in the gure.
IMPORTANT: the maximum allowed length of an Ethernet connection between two devices is 100 m (for longer dis-
tances, use switch P/N KITSE08000).
...
Quadro
di zona
1
Quadro
di zona
2
Quadro
di zona
12
NOL
Zona 1 Zona 2 Zona 12
NOV NOV NOV
Fig. 5.a
Ref. Description
NOL Normally open line drain valve
NOV Normally open vent valve
Tab. 5.b
5.1.2 Supervisor connection
The connection to the supervisor network can be made in two ways:
• between the Ethernet port on the pumping station and the supervisor network
• via RS485 serial link between the BMS2 port on the pumping station controller and the supervisor network. In the latter case,
the communication settings need to be changed when commissioning the system.
Eth1
Eth2
28
17
J25 BMS2
J25 BMS2
Tx/Rx
Tx/Rx
GND
GND
17
J25 BMS2
Tx/Rx GND
Fig. 5.b
Zone 1 Zone 2
Zone 1
panel
Zone 2
panel
Zone 12
panel
Zone 12

19
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
5.2 Distribution system
5.2.1 Drain valve management (NOL)
The pumping station manages and controls the line drain valve (NOL, normally open). The zone panel can also manage a con-
nected line drain valve.
Notice: the line drain valve must be tted at the lowest point in the water circuit and wired to the nearest electrical pan-
el (pumping station or zone panel), so that when opened, the entire system is emptied.
Case 1: Pumping station located below the distribution manifolds
Connect the drain valve near to pumping station that will control its opening.
Case 2: Pumping station located above the distribution manifolds, placed at dierent heights.
The drain valve must be connected near to the lowest distribution manifold.
Notice: the control signal for the zone 12 drain valve is output J12 NO3 on the zone electrical panel controller. See the
corresponding manual.
Case 3: Distribution manifolds located both above and below the pumping station
Connect multiple drain valves at the lowest points in the water circuit.
...
Quadro
di zona
2
Quadro
di zona
12
Quadro
di zona
11
Quadro
di zona
1
NOV
NOL
NOL
NOV NOV
Zona 1 Zona 2 Zona 11
Zona 12
Fig. 5.c
5.3 Functional diagrams - room
IMPORTANT: the blower ll and drain valves are contained in the directbox hydraulic panel. The maximum allowable
length for the water line leaving and re-entering the directbox or that, if no directbox is installed, connects the ll valve to the
drain valve, is 1181 inches.
Notice: when making the water connections, always observe the following warnings:
• limit as much as possible the length of the ll/drain line on each distribution circuit;
• ensure a minimum slope of the piping to assist emptying during the drain cycle.
Zone 12
panel
Zone 2
panel
Zone 1
panel
Zone 11
panel
Zone 1 Zone 2 Zone 11

20
ENG
humiFogTouch +0300113EN rel. 1.0 - 15.03.20221
Case 1: 1 zone with 1 steps
NOL
Zona 1
NC1 NO1
Alimentazione
230V
Direct Box
Direct Box
Sensore
di umidità
Quadro
di zona
1
24V
Fig. 5.d
Case 2: 1 zone with 2 steps
NOL
Step 1
Direct Box
Direct Box
NC1 NO1
Alimentazione Alimentazione
230V
Step 2
Direct Box
Direct Box
230V
24V NC2 NO2
24V
Sensore
di umidità
Quadro
di zona
1
Fig. 5.e
Case 3: 2 zones with 1 step
NOL
Zona 1Zona 2
NC1 NO1
Alimentazione Alimentazione
24V
Sensore
di umidità 1
Sensore
di umidità 2
Direct Box
Direct Box
Direct Box
Direct Box
Quadro
di zona
1
Quadro
di zona
2
Fig. 5.f
Humidity
sensor
Power supply
Zone 1
Zone
panel
1
Humidity
sensor
Humidity
sensor 1
Humidity
sensor 2
Power supply
Power supply
Power supply
Power supply
Step 1
Zone 1
Step 2
Zone 2
Zone
panel
1
Zone
panel 1
Zone
panel 2
Table of contents
Other Carel Water Pump manuals
Popular Water Pump manuals by other brands

SprayTECH
SprayTECH EP2510 owner's manual

Quincy
Quincy QSV 2200 instruction manual

PVR
PVR DRY 100 Operating and maintenance instructions

XPOtool
XPOtool 63004 user manual

Dover
Dover PSG Wilden PRO-FLO P1500 ENGINEERING OPERATION & MAINTENANCE MANUAL

Wilo
Wilo VeroLine IPH Series Installation and operating instruction