Table of Contents
INTRODUCTION .............................................................................................3
Labeling and Terminology ..................................................................................3
Foreword ...............................................................................................3
Tools ..................................................................................................3
Measurements...........................................................................................3
IMPORTANT PRECAUTIONARY INFORMATION ........................................................... 5
SECTION 1 – OUTDOOR FURNACE INSTALLATION........................................................ 6
PLANNING THE LOCATION ....................................................................................6
INSTALLATION PRECAUTIONS.................................................................................7
Chimney Recommendations ................................................................................7
GENERAL INSTALLATION INFORMATION ........................................................................8
Foundation..............................................................................................8
Potable Water ...........................................................................................8
Antifreeze ..............................................................................................8
Corrosion Inhibitor Plus™ ..................................................................................8
Shut-Off Valves ..........................................................................................9
Ground Rod Kit ..........................................................................................9
SUPPLY AND RETURN LINES ..................................................................................9
Temporary Above Ground or Winter Installations ...............................................................10
Digging the Trench ......................................................................................10
Underground Electric Wire ................................................................................10
Connecting to Existing Heating System ......................................................................10
INSTALLING LP TANK & GAS PIPING ...........................................................................11
HIGH ALTITUDE INSTALLATIONS ..............................................................................11
CIRCULATION PUMPS.......................................................................................11
Water Flow.............................................................................................11
Access to Ports on Outdoor Furnace ........................................................................11
Pump Selection .........................................................................................11
Installing Circulation Pumps ...............................................................................12
Shut-Off Valves .........................................................................................14
Filters.................................................................................................14
Thermostatic Valves .....................................................................................14
Thermostatic Valve Exemption .............................................................................14
Optional Gas-red Wood Ignition Burner......................................................................16
Purging Air from the System - Manual Air Bleeders .............................................................16
WATER HEATER INSTALLATION...............................................................................16
EXISTING FORCED AIR INSTALLATION.........................................................................17
Thermostatic Controls ....................................................................................20
HEATING MULTIPLE ZONES ..................................................................................21
HYDRONIC INSTALLATIONS ..................................................................................22
Pressurized Boiler System Installations ......................................................................23
Water-to-Water Heat Transfer System........................................................................23
Vented System Installation ................................................................................24
Direct Circulation Baseboard Installation......................................................................25
Radiant Floor System Installations ..........................................................................26
Pool and/or Hot Tub Heating ...............................................................................29
FILLING OUTDOOR FURNACE WITH WATER AND PURGING AIR....................................................30
SECTION 2 – OPERATING INSTRUCTIONS .............................................................. 32
Wood Selection and Preparation............................................................................32
FIRESTAR CONTROLLER ....................................................................................32
Operating the E-Classic for Maximum Efciency and Performance .................................................32
Importance of Properly Seasoned Wood......................................................................33
Air Flow and Maintaining the Coal Bed .......................................................................33
Ash Removal Frequency ..................................................................................34
COLD START FIRING ........................................................................................34
Cold Start Firing.........................................................................................34
Cold Start Firing with Power Ignition .........................................................................35
ADDING HEAT LOAD ........................................................................................36
LOAD WOOD TO REDUCE CONDENSATION.....................................................................37
SECTION 3 – MAINTENANCE ......................................................................... 40
CONTROL LOCATIONS ......................................................................................41
ROUTINE MAINTENANCE ....................................................................................41
WATER QUALITY AND MAINTENANCE .........................................................................49
Water Test Kits and Test Results ............................................................................49
Testing Supply Water.....................................................................................49
Corrosion Inhibitor Plus™ and Initial Treatment ................................................................50
Testing Treated Water in the Outdoor Furnace .................................................................50
System Maintenance .....................................................................................50
POST HEATING SEASON MAINTENANCE .......................................................................51
Flushing the System .....................................................................................51
SECTION 4 – SERVICEABLE ITEMS.................................................................... 52
FIREBOX DOOR SEAL.......................................................................................52
FIREBOX DOOR LATCH BEARING ADJUSTMENT ................................................................52
REACTION CHAMBER DOOR SEAL ............................................................................53
EXTERIOR LED LIGHTS .....................................................................................53
CIRCUIT BREAKER .........................................................................................53
BYPASS DOOR ROPE .......................................................................................54
SOLENOID ................................................................................................54
SECONDARY AIR CHARGE TUBE AND REFRACTORY MODULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
THERMOCOUPLE ..........................................................................................55
SECTION 5 – TROUBLESHOOTING .................................................................... 56
SECTION 6 – GENERAL INFORMATION.........................................................................63
E-CLASSIC 1450 WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
E-CLASSIC 1450 WIRING DIAGRAM - OPTIONAL POWER IGNITION .................................................65
GLOSSARY ................................................................................................66
1-YEAR LIMITED WARRANTY ..........................................................................Back Cover