CME America BodyGuard 323 User manual

Ambulatory Infusion Pump
BodyGuardT\\\ 323
Clinician Quick Reference
Using the Extended-Life Rechargeable Battery
CMEAmericaTM
Confirming Battery Charge Status When Pump Running
1. Press twice.
2. Battery Level display will appear.
3. In about 20 seconds, display will return to infusion status.
Confirming Battery Charge Status When Infusion Stopped
1. Press twice.
2. Press to scroll to Review Set-Up command.
3. Press twice to select command.
4. Battery Level display will appear.
Recharging Battery
• During pump operation, battery will charge as long as pump is connected to Wall Charger.
• When pump not operating, battery will charge when Wall Charger is plugged into AC power.
• Fully-depleted battery takes 6 hours to recharge. Battery does not need to be empty to charge.
• For Wall Charger instructions see reverse side of this sheet.
Helpful Tips
• To avoid complete loss of power, check battery life each morning.
• When Low Battery alert occurs, connect Wall Charger to pump as soon as possible. You have
about 30 minutes before total loss of battery power.
• If End Battery alarm occurs, infusion will stop. If this happens, turn off pump. Then plug in
Wall Charger. Wait 2 minutes before turning pump on and resuming infusion.
Info
Info
Info
Info
0
START
OK
Battery Level
Empty Full
Battery Level
Empty Full
Volume Infused
Program Lock
Review Set up
Change Set up
Important
• To avoid disrupting infusion therapy, periodically recharge
Extended-Life Rechargeable Battery using Wall Charger.
• If you experience problems with pump operation, do not remove
Extended-Life Rechargeable Battery. Contact the pharmacist.
Approximate Battery Life
At 1000 ml/hr: 20 hrs
At 125 ml/hr: 72 hrs
At 5 ml/hr: 170 hrs
Ambulatory Infusion Pump
BodyGuardTM 323
Clinician Quick Reference
Using the Wall Charger
For 24/7 clinical and technical support, call: 877.263.0111
CAUTION: Before use, the user must become thoroughly familiar with the information contained in the device operating instructions.
Note: This Clinician Quick Reference provides a convenient information summary. For complete information on proper use of the BodyGuard
pump refer to the device operating instructions supplied with the product. © 2008 by CME America, LLC. All rights reserved. The following are
trademarks of CME America, LLC: BodyGuard, BodyComm, TSyringePump, the CME America logotype with “swirl” logomark and the tag line
“Drug Delivery Designed for the Way You Deliver Care.” SM-0016 07/2008
CMEAmericaTM
Drug Delivery Designed for the
Way You Deliver CareTM
CME America, LLC
14998 W. 6th Ave., Suite 830
Golden, CO 80401 USA
What’s Required to Power Pump
Wall Charger Pump DC Port Charger-to-Pump Connection
Wall Charger light shows red
until pump battery fully
charged. Then light turns green.
To Confirm Wall Power Is On
When Wall Power Removed
• Pump screen display remains
lit for short interval.
• Battery symbol will appear on
screen display.
To Disconnect Charger From Pump
1. Press and hold black button located on
Wall Charger connector.
2. Pull connector straight out.
Green light flashes on
pump front panel.
Pump
screen
display
remains
lit.

Popular Water Pump manuals by other brands

dosatron D8R owner's manual

dosatron

dosatron D8R owner's manual

Debem MB 100 Instructions for use and maintenance

Debem

Debem MB 100 Instructions for use and maintenance

Kärcher SP 6 Flat Inox manual

Kärcher

Kärcher SP 6 Flat Inox manual

Edwards STP-XA2703 Series instruction manual

Edwards

Edwards STP-XA2703 Series instruction manual

Wilo Varios PICO Installation and operating instructions

Wilo

Wilo Varios PICO Installation and operating instructions

PRAKASH SP-R5A-8 Installation, maintenance and operation manual

PRAKASH

PRAKASH SP-R5A-8 Installation, maintenance and operation manual

Atmos Laddomat 22 user manual

Atmos

Atmos Laddomat 22 user manual

Oase Aquarius Universal 21000 operating instructions

Oase

Oase Aquarius Universal 21000 operating instructions

Watson Marlow Pumps 521CC manual

Watson Marlow Pumps

Watson Marlow Pumps 521CC manual

Pentair VLR 2B-30/2A manual

Pentair

Pentair VLR 2B-30/2A manual

Schmalz EVE-OG-25 F Installation and operation instructions

Schmalz

Schmalz EVE-OG-25 F Installation and operation instructions

Regulus CSE SOL G SRS1 T-E Installation and operation manual

Regulus

Regulus CSE SOL G SRS1 T-E Installation and operation manual

Becker dvt 3.140 operating instructions

Becker

Becker dvt 3.140 operating instructions

Xylem FLYGT APP 412 Installation, operation and maintenance manual

Xylem

Xylem FLYGT APP 412 Installation, operation and maintenance manual

Siccom Mini FLOWATCH 2 installation instructions

Siccom

Siccom Mini FLOWATCH 2 installation instructions

Tuxhorn tubra-PGS 01 Assembly and operating instructions

Tuxhorn

Tuxhorn tubra-PGS 01 Assembly and operating instructions

Becker VARIAIR DTLF 2.500/0-400 operating instructions

Becker

Becker VARIAIR DTLF 2.500/0-400 operating instructions

GÜDE RFP 12-201-04 Translation of the original instructions

GÜDE

GÜDE RFP 12-201-04 Translation of the original instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.