Setting
Taclite
Setting
Blend #1
O2%
Bridge Contacts 1 & 2
with wetted fingers to
access Logbook.
Short Contacts 1 & 2 with a Coin
selects the next programming option.
Dive Logbook
Main Menu Selection
Bridge Contacts 1 & 2
with wetted fingers to
access Blend #1 O2%..
Short Contacts 1 & 2 with a Coin
selects the next programming option.
Set Blend #1
Main Menu Selection
Bridge Contacts 1 & 2
with wetted fingers to
access Taclite on Time.
Short Contacts 1 & 2 with a Coin
selects the next programming option.
Taclite Dwell Time
Main Menu Selection
Bridge Contacts 1 & 2 with wetted
fingers to select next digit.
Short Contacts 2 & 3 with Coin
to increment digit value.
(Digit being programmed flashes)
Bridge Contacts 1 & 2 with wetted
fingers to select next digit.
Short Contacts 2 & 3 with Coin
to increment digit value.
(Digit being programmed flashes)
Surface Interval
(Amount of time
prior to the dive)
..
NDC
A
S
C
T
N
E
DEPTHMAXBOTTOM
TEMPREMAIN TIME
SURF
Main
Screen
Alternate
Screen
Ascent Rate Water Temperature
(Maximum Ascent
Rate during dive)
Nitrox O2%
(Of current Blend
set point).
NDC Time Remain
(Amount of NDC time)
Normal Dive
CNS Oxygen
Toxicity in %
Battery
Voltage
OTU Oxygen
Toxicity in %
Bottom Time
(Of the dive)
Max Depth
(Of the dive)
Blend #1 O2 percentage can be set from 21.0 to 50.0%
Taclite delay time can be set from 1 to 98. 0 = Taclite always off. 99 = Taclite always on.
Use only fresh 3.0 volt Lithium batteries (CR12600SE).
Rinse the unit with clean fresh water after each dive.
Do not put the Commander away while wet.
Do not subject unit to compressed air.
Do not remove the lens from the unit.
Do not use a screwdriver to remove the battery cap.
Menu
Screen
W/Dive #
Dive Number.
(Most recent displayed first,
then next previous)
Bridge Contacts 1 & 2 with
wetted finger to select next dive.
Alternate
Screen
Primary
Screen
Minutes
00 to 59
Hour
00 to 24
Month
(Of the dive)
Date
(Of the dive)
Year
(Of the dive)
3
..
Information
Screen
NDC
DEPTH
REMAIN TIME
..
Predict
Screen
Setting
Depth
Setting
Conservatism
Short Contacts 1 & 2 with a Coin
selects the next programming option.
PreDive Prediction
Main Menu Selection
Predict Time (h:mm)
(Programmed FO2 or PO2
value influences time).
Bridge Contacts 1 & 2
with wetted fingers to
access PreDive Prediction.
Predict Depth
(Bridge Contact 1 & 2
with wetted finger to
increment depth).
Calculated PO2
(Computed from FO2
Blend #1 Set Point
for predict depth.)
Bridge Contacts 1 & 2
with wetted fingers to
access Information.
Short Contacts 1 & 2 with a Coin
selects the next programming option.
Bridge Contacts 1 & 2
with wetted fingers to
access Conservatism.
CNS Oxygen
Toxicity in %
Battery
Voltage
OTU Oxygen
Toxicity in %
Short Contacts 1 & 2 with a Coin
selects the next programming option.
Information Screen
Main Menu Selection
Mode/Blend Identifiers
(F0=Air only, F1=1 FO2
F2=2 FO2, P1=1 PO2,
P2=2PO2 ).
Depth Alarm
Main Menu Selection Short Contacts 2 & 3 with Coin
to increment digit value.
(Digit being programmed flashes)
Short Contacts 1 & 2 with a Coin
selects the next programming option.
Conservatism
Main Menu Selection
Bridge Contacts 1 & 2 with wetted
fingers to select next digit.
Bridge Contacts 1 & 2 with wetted
fingers to select next digit.
Short Contacts 2 & 3 with Coin
to increment digit value.
(Digit being programmed flashes)
Conservatism can be set from 0 (no conservatism) to 50 (Maximum conservatism)
Depth Alarm can be set from 0 to 320 Feet
-To activate touch programming, the unit
needs to be in a Normal Surface Interval.
-Shorting contacts 1 & 2 with a coin
changes the top level menu selection.
Touch Programming
-Shorting contacts 1 & 2 with wet finger
takes you into that menu selection.
-The digit that is flashing is the one that
is going to be incremented.
-Shorting contacts 2 & 3 with a wet finger
or coin increments the digit that is flashing.
-Shorting contacts 1 & 2 with a wet finger makes the next digit flash.
-Touch Programming is automatically terminated after 5 minutes of no activity.
-Touch Programming is automatically terminated if a dive is started.
-Always scroll back through data to ensure it was entered and stored as desired.
-CLOCK comes from the factory disabled. If enabled, “CLC” will be the first
screen seen in Touch Programming. See back page for details.
CONTACT #3
CONTACT #2
CONTACT #1
Bridge Contacts 1 & 2
with wetted fingers to
access Depth Alarm.
2
TEMP
.
Main
Screen
Alternate
Screen
DEC
A
S
C
T
N
E
DEPTHMAXBOTTOM
CEILREMAIN TIME
SURF
Deco Dive
Short Contacts 1 & 2 with
a Coin exits programming. CNS Oxygen
Toxicity in %
Battery
Voltage
OTU Oxygen
Toxicity in %
Nitrox O2%
(Of current Blend
set point).
Max Deco
Ceiling
DEC Time Remain
(Max amount of Deco time)
Deco Dive
(Water Temperature)
This is indicated by the ‘SURF’ legend flashing once per second.
D
I
V
E
DEPTHMAXBOTTOM
TEMPFLY
SURF
..
BATT
..
Main
Screen
Alternate
Screen
POST DIVE INTERVAL
The first ten minutes after a dive the Commander will be
in the Post Dive Interval Mode.
If a dive is initiated while the Commander is in this mode it will
be considered a continuation of the previous dive.
Bottom Time
(Of the last dive)
Surface Interval
(Amount of time
since the last dive)
Dive of “Day”
(Repetitive Dive
Number)
Time To Fly
(Hours before
safely flying.)
Max Depth
(Of the last dive) Battery
Voltage
CNS Oxygen
Toxicity in %
Nitrox O2%
(Blend #1 Set Point)
OTU Oxygen
Toxicity in %
SURF legend
(Flashing.)
Ascent Rate Bar Graph in Feet Per Minute (fpm)
Greater than 60 Feet Per Minute,
WARNING and top bar of graph will flash.
A
S
C
T
N
E
10 To 19 fpm
20 To 29 fpm
30 To 39 fpm
40 To 49 fpm
50 fpm or more
Fixed at 60 fpm
Current factory settings for the Ascent
Rate Bar Graph are: Variable-by-depth,
Proportional, with a Sensitivity of ‘3’
(Nominal). Subject to change without
notice.
Depth Greater than 60 ft
A
S
C
T
N
E
10 To 19 fpm
20 To 29 fpm
30 To 39 fpm
40 To 49 fpm
50 fpm or more
A
S
C
T
N
E
5 To 9 fpm
10 To 14 fpm
15 To 19 fpm
20 To 24 fpm
25 fpm or more
Depth less than 30 ft
Via the Analyst, the Ascent Bar Graph can be set to:
- Variable-by-depth where Bar value determined by
depth: 60 feet and deeper - 60 fpm
59 to 30 feet - fpm equal to depth
Less than 30 feet - 30 fpm
- Proportional Each Bar is 20% of selected rate
- Fixed (Speed) Each bar is 10 fpm
- Sensitivity from 0 to 7 (See Manual)
Variable-by-depth and Proportional Selected
4