GENERAL INFORMATION SPECIFICATIONS
OPERATION
OVERLOAD PROTECTION
THANK YOU FOR PURCHASING A
COMFORT HOME PRODUCT
Take the time to read the instructions carefully before using this
appliance. We strongly recommend that you keep this instruction
manual in a safe place for future reference.
Before use, read the following instructions carefully. Closely following
these instructions will eliminate potential operating problems, assuring
years of trouble-free service.
WARNING
WARNING
CAUTION
CAUTION
Risk of electric shock. The pump is supplied with a grounding
conductor and grounding-type attachment plug. To reduce the risk of
electric shock, install only on a circuit protected by ground-fault circuit-
interrupter. Always disconnect the pump from the power source before
handling or making adjustments. Always wear rubber boots when
servicing in wet areas. Make sure the pump power source is a separately
fused, grounded 3-wire type receptacle of 15-amp capacity. DO NOT
REMOVE GROUND PRONG OR PLUG. DO NOT USEAN EXTENSION
CORD. Check to make sure installation is in accordance with the
National Electric Code and all applicable local codes. Installation and
servicing are to be conducted by qualified personnel.
● DO NOT pump flammable liquids
● DO NOT use around explosive materials
● DO NOT handle unit with wet hands or while standing in water
● DO NOT lift the pump by the power cord
●
DO NOT connect to any voltage other than that listed on the
nameplate
1.Set pump on hard surface in water before starting.
2.
Use the included garden hose adapter for properly discharge line
or disconnect the adapter to use a properly discharge.
3.
Plug power cord into properly grounded AC power outlet. Will operate
continuously whether partly or fully submerged. Submersible utility
pumps are intended to pump water at temperatures up to 104˚F(40˚C).
4.
To prevent unnecessary wear, unplug the pump from the power
output when not in use.
5.
The pump is supplied with the garden hose adapter. For use with
plastic pipe, remove the adapter and install the desired properly
fitting. DO NOT OVERTIGHTEN THE HOSE OR PLASTICADAPTER
FITTING. Finger tight plus 1/2 turn is sufficient.
6.
Pump equipped with Optional
Float switch. When the pump
senses that it is no longer
pumping water, the pump will
shut off automatically.
● DO NOT use in water over 104˚F (40˚C).
● DO NOT modify the pump in any way
● DO NOT expose pump or discharge to freezing temperatures
●
DO NOT use this product to pump salt water or brine. Use with
salt water or brine will void the warranty. Pump water only.
●
Do not set pump directly on sand, dirt or mud. Sand or mud-choked
pumps can Be back-flushed clean.
●
Do not handle or carry the pump by the power cord. Use the handle.
●
Extended usage of the pump in a partially submerged or non
-
submerged situation may cause the pump to overheat due to lack
of heat dissipation from the water. If this occurs, the pump will shut
itself off until the motor cools to its normal temperature. Repeated
overheating may cause damage to the pump.
This pump series has a built in thermal protection switch. The pump
stops if an overload condition occurs.
The motor restarts automatically after it has cooled down.
TROUBLESHOOTING CHECKLIST
(CAUTION: SHUT OFF POWER TO PUMP)
PROBLEMS POSSIBLE CAUSES
Pump does
not run
and hums
●Line circuit breaker is off, or fuse is burned or loosed.
●
Water level in sump has not reached turn-on level as indicated in
installation drawing.
●Pump cord is not making contact in receptacle. 
●Float is stuck. It should operate freely in basin.
●If all of the above are OK, and then the motor could be operate.
Head
(Pressure) Pipe
Connection
Flow
(Capacity)
Phase Power
1
1
1
1
Rated
(M)
5
4
5
6
Max.
(M)
7
6.5
8
9
mm
5
3
5
5
Rated
(L/Min)
60
35
80
120
Max.
(L/Min)
140
70
180
220
mm
32
25
40
50
inch
1-1/4
1
1-1/2
2
Model
UP25/(A)
UP15/(A)
UP
UD
UP35/(A)
UP50/(A)
HP
1/4
1/6
1/3
1/2
Watt
200
100
300
400
Weight
(kg)
4.2/(4.7)
3.1/(3.6)
6.6/(7.1)
7.6/(8.1)
Head
(Pressure) Pass
Solid
(Dia)
Pass
Solid
(Dia)
Pipe
Connection
Flow
(Capacity)
Phase Power
1
1
Rated
(M)
4.3
3.6
Max.
(M)
6.5
5.5 mm
5
5
Rated
(L/Min)
90
60
Max.
(L/Min)
180
120
mm
32
32
lnch
1-1/4
1-1/4
Model
UD25/(A)
UD15/(A)
HP
1/4
1/6
Watt
200
120
Weight
(kg)
3.8/(4.3)
3.2/(3.7)
UP & UD Series
Installation and Operating Instructions
Limited Warranty:
Products of Comfort Home are warranted to the first user only to be free
of defects in material and workmanship for a period of 12 months from date
of installation, but no more than 18 months from date of manufacture.
Comfort Home's liability under this warranty shall be limited to repairing or
replacing at our election, without charge, FOB Comfort Home's distribution
center or authorized service agent. Comfort Home will not be liable for
any cost of removal, installation, transportation or any other charges that
may arise
in connection with warranty claim.
The warranty period commences on the date of original purchase of the
equipment. Proof of purchase and installation date, failure date, and
supporting installation data must be provided when claiming repairs
under
warranty.
This warranty is subject to due compliance by the original purchaser with
all directions and conditions set out in the installation and operating
instructions. Failure to comply with these instructions, damage or breakdown
caused by fair wear and tear, negligence, misuse, incorrect installation,
inappropriate chemicals or additives in the water, inadequate protection
against freezing, rain or other adverse weather conditions, corrosive or
abrasive water, lightning or high voltage spikes or through unauthorized
persons attempting repairs are not covered under warranty.
Comfort Home will not be liable for any incidental or consequential damages,
losses, or expenses, arising from installation, use, or any other causes.
There are no express or implied warranties, including merchantability
or fitness for a particular purpose, which extend beyond those
warranties described or referred to above.
Certain countries do not permit the exclusion or limitation of incidental
or consequential damages or the placing of limitations on the duration
of an implied warranty, therefore, the limitations or exclusions herein
may not apply. This warranty sets forth specific legal rights and
obligations, however, additional rights may exist, which may vary from
countries to countries.
Supersedes all previous publications.
Submersible Utility Pump
CCBUPUDE01
Pump runs
but does
not deliver
water.
●Check valve is installed backwards.
Arrow on valve should point in direction of flow.
●Discharge shut-off valve (if used) may be closed.
●Impeller or volute openings are fully or partially clogged.
Remove pump and clean.
●
Pump is air-locked. Start and stop several times by plugging and
unplugging cord. Check for clogged vent hole in pump case.
●Inlet holes in pump base are clogged. Remove pump and clean
the openings.
●
Vertical pumping distance is too high. Reduce distance or change
the discharge fittings of the pump.
Pump runs
and pumps
out sump,
but does
not stop.
●
Float is stuck in up position. Be sure float operates freely in
basin.
●Defective float switch. Replace with float switch.
●Defective vertical switch. Replace with vertical switch.
Pump runs
but delivers
only a small
amount of
water.
●
Pump is air-locked. Start and stop several times by plugging and
unplugging cord. Check for clogged vent hole in pump case.
●
Vertical pumping distance is too high. Reduce distance or change
the discharge fitting of the pump. Inlet holes in pump base are
clogged. Remove pump and clean the strainer and openings.
●Impeller or volute openings are fully or partially clogged.
Remove pump and clean.
●
Pump impeller is partially clogged with tar or paint, causing motor
to run slow and overload. Remove pump and clean.
Fuse blows
or circuit
breaker
trips when
pump starts.
Motor runs
for a short
time, then
stops.
●
Pump impeller is partially clogged with tar or paint, causing motor
to run slow and overload. Remove pump and clean.
●Motor stator may be defective.
●Fuse size or circuit breaker may be too small.
●Impeller or volute opening are fully or partially clogged.
Remove pump and clean.
●Inlet holes in pump base are clogged. Remove pump and clean
the openings.
●
Pump impeller is partially clogged with tar or paint, causing motor
to run slow and overload. Remove pump and clean.
●Motor stator may be defective.
●Impeller or volute openings are fully or partially clogged.
Remove pump and clean also clean the strainer if you had installed.
WEBSITE : www.everyfluid.com
E-MAIL : [email protected]
R
Comfort Home
Water Solutions
Comfort Home
R
Comfort Home

This manual suits for next models

13

Other Comfort Home Water Pump manuals

Comfort Home IDS Series User manual

Comfort Home

Comfort Home IDS Series User manual

Comfort Home ASB Series User manual

Comfort Home

Comfort Home ASB Series User manual

Popular Water Pump manuals by other brands

MULTIQUIP ST-2010 Series Operation and parts manual

MULTIQUIP

MULTIQUIP ST-2010 Series Operation and parts manual

EUROM Flow Pro 550CW operating instructions

EUROM

EUROM Flow Pro 550CW operating instructions

Edwards 18B4B instruction manual

Edwards

Edwards 18B4B instruction manual

KTM TRILINE Operation and maintenance manual

KTM

KTM TRILINE Operation and maintenance manual

Wilo Wilo-IPL Installation and operating instructions

Wilo

Wilo Wilo-IPL Installation and operating instructions

MasterCraft 062-3503-8 instruction manual

MasterCraft

MasterCraft 062-3503-8 instruction manual

Speck pumpen Aquacell A Series Assembly and operating instructions

Speck pumpen

Speck pumpen Aquacell A Series Assembly and operating instructions

TorcUP EP500 Owner's operation and maintenance manual

TorcUP

TorcUP EP500 Owner's operation and maintenance manual

ProMinent Sigma 2 S2Ca operating instructions

ProMinent

ProMinent Sigma 2 S2Ca operating instructions

Flotec FPI800DCC owner's manual

Flotec

Flotec FPI800DCC owner's manual

Grundfos SL1 Series Safety instructions

Grundfos

Grundfos SL1 Series Safety instructions

T.I.P. BRIO 2000 M operating instructions

T.I.P.

T.I.P. BRIO 2000 M operating instructions

Flotec WATERPRESS 1000 Use and maintenance manual

Flotec

Flotec WATERPRESS 1000 Use and maintenance manual

Pentair D65-20AVD Operator's and service manual

Pentair

Pentair D65-20AVD Operator's and service manual

MULTIQUIP ST-45HRM Operation and parts manual

MULTIQUIP

MULTIQUIP ST-45HRM Operation and parts manual

Erduro BTS ENGINEERING Fluid Solutions BTKF-I user manual

Erduro

Erduro BTS ENGINEERING Fluid Solutions BTKF-I user manual

Moog RKP-D user manual

Moog

Moog RKP-D user manual

GE UPK3 installation instructions

GE

GE UPK3 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.