USER’S MANUAL
-7-
PRODUCT INTRODUCTION
〖Protect Functions〗
Protect functions can prolong the air conditioner’ s service life and provide more comfortable airflow.
Delay-starting protection for the compressor
The compressor will restart working at least 3 minutes after being turned off to keep the pressure balance
of the cooling system.
Remarks:
Defrosting (not available for cooling-only type air conditioner)
The outdoor heat exchanger may frost if the outdoor temperature is low and humidity is high. In this case,
auto-defrosting has operated for sometimes. pause indicator will be on, indoor and outdoor fan stop.
Heating overload protection (not available for cooling-only type air conditioner)
When the temperature of indoor pipe is too high, air conditioner enters heating overload protection.
Blowing residual heat function (not available for cooling-only type air conditioner)
Indoor fan will keep running at low fan speed for some seconds when air conditioner is stopped in heating
mode.
Cooling airflow proof (not available for cooling-only type air conditioner)
In the first several minutes of heating operation, PAUSE indicator lights; indoor fan doesn’t run and louver
blades can not be controlled. About some minutes later, air conditioner will blow heat airflow, PAUSE
indicator is off.
Freeze-prevention
To prevent indoor heat exchanger freezing in cooling and dehumidification operation, compressor or
outdoor fan may stop running; indoor fan speed will be adjusted to a higher gear automatically.
Dry for enzyme-prevention (optional)
Indoor fan motor will go on running for 3 minutes at low fan speed when turned off in cooling mode in order to
keep dry condition inside the unit.
Reset power or Auto restart( alternative)
Reset power: When there is a power suspension, air conditioner will automatically switch off. When the
power is back, the unit will automatically reset power. For energy saving if there is no person in the room,
air conditioner will stay in PAUSE status. User needs to turn on Air conditioner by remote controller.
Auto restart: The unit memories the operation mode, air flow setting, temperature setting etc., so that
should there be a power failure when the unit is in operation, it will automatically return the same
operating conditions when the power is restored.
Cooling overload working (optional)
Drip proof (optional)
In cooling and dehumidification operation, louver blades can change the position automatically to prevent
from dripping.