Ver.1.05
AIO-163202FX-USB 2
Plug-ins for the dedicated libraries, this product also supports
MATLAB and LabVIEW.
We offer a dedicated library [ML-DAQ], which allows you to use this
product on MATLAB by The MathWorks as well as another dedicated
library [VI-DAQ], which allows you to use the product on LabVIEW by
National Instruments. These dedicated libraries are available, free of
charge (downloadable), on our web site.
*1 Do not connect the device other than that of CONTEC’s USB to the USB port included on the AIO-163202FX-
USB. Otherwise, this may cause a failure or malfunction.
*2 When connecting multiple units with USB HUB function and set up them, do one at a time and complete
setup for the previous unit before starting to do the next unit.
*3 When using the optional connector conversion cable ADC-68M/96F.
*4 There are some differences of the specifications between this product and AIO-163202F-PE, ADA16-
32/2(PCI)F and ADA16-32/2(CB)F. For more details on this, refer to “Chapter7, Difference from AIO-163202F-
PE, ADA16-32/2(PCI)F and ADA16-32/2(CB)F”
*4 This product cannot be stacked up for installation.
Single-Ended Input or Differential Input
32channels (Single-Ended Input) 16channels (Differential Input)
Bipolar ±10V, ±5V, ±2.5V
or Unipolar 0 - +10V, 0 - +5V, 0 - +2.5V
Absolute max. input voltage
sec/ch (Max.) *3 [500KSPS]*4
128K data FIFO or 128K data RING
Software, conversion data compare, external trigger, and event controller
output etc.,
Settings include data save complete, conversion data compare,
external trigger, event controller output, and software etc.,
LVTTL level (Rising or falling edge can be selected by software)
LVTTL level (Rising or falling edge can be selected by software)
LVTTL level (Rising or falling edge can be selected by software)
External status output signal
LVTTL level : 2
Sampling clock output
Number of output channels
Bipolar ±10V, ±5V, ±2.5V, ±1.25V
or Unipolar 0 - +10V, 0 - +5V, 0 - +2.5V
Absolute max. output
current
128K data FIFO or 128K data RING
Software, external trigger, and event controller output etc.,
Settings include data save complete, external trigger, event controller output,
and software etc.,
LVTTL level (Rising or falling edge can be selected by software)
LVTTL level (Rising or falling edge can be selected by software)
LVTTL level (Rising or falling edge can be selected by software)
External status output signal
LVTTL level : 2
Sampling clock output
Non-isolated input 8channels (LVTTL level positive logic)
Number of output channels
Non-isolated output 8channels (LVTTL level positive logic)
FFFFFFFFh (Binary data, 32bit)
Number of external inputs
LVTTL level : 2 (Gate/Up)/ch,
Gate (High level), Up (Rising edge)
Number of external outputs
LVTTL level : 1/ch,
Count match output (positive logic, pulse output)
USB Specification 2.0/1.1 standard
12Mbps (Full-speed), 480Mbps (High-speed) *5
Attached AC adapter
(POA200-20-2)
90 - 264VAC 5.0VDC±5% 2.0A (Max.)
Cable length : about 1.5m, AC Cable length : about 1.5m
96-pin half pitch connector [M(male)type]
PCR-96LMD+ [HONDA TSUSHIN KOGYO CO., LTD.] or equivalence to it
Number of terminals used at
the same time
0 - 50°C, 10 - 90%RH (No condensation)
* When using the attached AC adapter POA200-20-2, it is 0 - 40°C
180(L) x 140(D) x 34(H) (No protrusions)
VCCI Class A,
CE Marking (EMC Directive Class A, RoHS Directive)
*1: A linearity error approximately 0.1% of full-range may occur when operated at 0ºC or 50ºC ambient
temperature.
*2: At the time of the source use of a signal which built in the high-speed operational amplifier.
*3: The required time is indicated in the analog to digital translation of one channel. When AD of two or more
channels is converted, time of the a few minutes of the channel is necessary. Conversion time = Number of
conversion channelsx2µsec
*4: SPS = Samplings Per Second. The number of data that can be converted in one second is shown.
*5: The USB transfer speed depends on the host PC environment used (OS and USB host controller).
*6: The supplied current is insufficient in the bus power. Please use the attached AC adaptor (POA200-20-2).
*7: As a USB hub is also counted as one device, you cannot just connect 127 USB terminals.
*8 To suppress the heating, ensure that there are spaces for ventilation (about 5cm) around this product..
AC adapter environmental condition (environmental specification)
47.5(W) x 75(D) x 27.3(H) (No protrusions)
20 - 80%RH(No condensation)
4 years at the ambient temperature 40 ºC
(When 100VAC is input and 1.3A is output)
Allowable time of short
interruption
15ms (Max.) (When 100VAC is input and 1.3A is output) *1
Voltage corresponding to the
attached AC cable
*1 When the short interruption occurs and the defective operation of the equipment is generated, please insert
the power supply of the equipment after pulling out it.
Driver Library API-AIO(WDM)
[Stored on the bundled disk driver library API-USBP(WDM)]
The API-AIO(WDM) is the Windows version driver library software that
provides products in the form of Win32 API functions (DLL). Various
sample programs such as Visual Basic and Visual C++, etc and
diagnostic program *1useful for checking operation is provided.
Data Logger Software C-LOGGER
[Stored on the bundled disk driver library API-USBP(WDM)]
C-LOGGER is a data logger software program compatible with our
analog input products. This program enables the graph display of
recorded signal data, zoom observation, file saving, and dynamic
transfer to the spreadsheet software “Excel”. No troublesome
programming is required. For details on the supported operating
systems and applicable languages and to download the latest version,
see the services on the CONTEC website
LabVIEW VI Library for Data Acquisition DAQfast for LabVIEW
(Available for downloading (free of charge) from the CONTEC web
site.)
This is a data collection library to use our devices in the LabVIEW by
National Instruments. With Polymorphic VI, our design enables a
LabVIEW user to operate seamlessly. Our aim is for the customers to
perform easily, promptly what they wish to do.
For more details on the library and download of DAQfast for LabVIEW,
please visit the CONTEC’s Web site.
Data acquisition VI library for LabVIEW VI-DAQ
(Available for downloading (free of charge) from the CONTEC web
site.)
This is a VI library to use in National Instruments LabVIEW. VI-DAQ is
created with a function form similar to that of LabVIEW's Data
PLUG-IN
Electronic
GmbH
•
Am
Sonnenlicht
5
•
82239
Alling
•
Tel.:
+49
(0)
8141
3697-0
•
[email protected] •
www.plug-in.de