DALCNET DLM Series Application guide

DLM Single Channel
Multi INPUT
EASY LINE
Device Manual FW 1.0
Made in Italy
Rev. 2018-07-30
pag. 1 7
FEATURES
• FADER+DIMMER+DRIVER
• DC Input: 12-24-48 Vdc or 12-24Vdc
• MULTI INPUT – Analogic Automatic Detection of the Local command:
- Normally Open push-button
- 0-10V
- 1-10V
- Potentiometer 10KOhm
• PUSH MENU’ – Possibility to set:
- Minimum value of dimming
- Fade In
- Fade Out
• Constant Voltage variant for Common Anode applications
• Voltage outputs for R-L-C loads, DLM1248-1CV variant
• Voltage outputs for R loads, DLM1224-1CV variant
• Memory function
• Adjusting the brightness of white light or monochromatic color
• Adjusting the brightness up to completed off
• Soft start and soft stop
• Sync function - Master Slave
• Optimized output curve
• Typical efficiency > 95%
• 100% Functional test - 5 Years warranty
➢ CONSTANT VOLTAGE VARIANTS
Application: Dimmer
CODE Input voltage Output Channels Analogic Auto Detection
DLM1248-1CV 12-48V DC 1 x 6,5A 1 N° 1 N.O. push button
N° 1 analog signal 0-10V
N° 1 analog signal 1-10V
N° 1 Potentiometer 10kOhm
DLM1224-1CV 12-24V DC 1 x 10A 1 N° 1 N.O. push button
N° 1 analog signal 0-10V
N° 1 analog signal 1-10V
N° 1 Potentiometer 10kOhm
The LED dimmer is produced by default with:
- Analogic Automatic Detection of local command set as N.O. ush Button
- Dimming minimum level 1%
➢ PROTECTIONS
DLM1248-1CV DLM1224-1CV
OTP Over temperature protection (*)
OVP Over voltage protection (**)
UVP Under voltage protection (**)
RVP Reverse polarity protection (**)
IFP Input fuse protection (**)
SCP Short circuit protection
OCP Open circuit protection
CLP Current limit protection
(*) Thermal Protection on the output channel in case of high temperature. The thermal intervention is detected by transistor (> 150°C).
(**) Only control Logic protection
DLM single channel
LED DRIVERS
DALCNET S.r.l.
Registered office: via Meucci, 35 - 36040 Brendola (VI) - Italy
Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy
Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453
VAT: IT-04023100235
info@dalcnet.com www.dalcnet.com
N
E
W
P
U
S
H
M
E
N
U

DLM Single Channel
Multi INPUT
EASY LINE
Device Manual FW 1.0
Made in Italy
Rev. 2018-07-30
pag. 2 7
➢ REFERENCE STANDARDS
EN 61347-1 Lamp controlgear - Part 1: General and safety requirements
EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and
similar equipment
EN 61547 Equipment for general lighting purposes - EMC immunity requirements
IEC 60929-E.2.1 Control interface for controllable ballasts - control by d.c. voltage - functional specification
ANSI E 1.3 Entertainment Technology - Lighting Control Systems - 0 to 10V Analog Control Specification
➢ TECHNICAL SPECIFICATIONS
DLM1248-1CV Variant DLM1224-1CV Variant
Constant voltage Constant voltage
Supply voltage min: 10,8 Vdc .. max: 52,8 Vdc min: 10,8 Vdc .. max: 26,4 Vdc
Output voltage = Vin = Vin
Output current 6,5A @40°C 1) 10A @40°C 1)
Absorbed nominal power 1) @12V 78 W 120W
@24V 156 W 240W
@48V 312 W -
Power loss in stand by mode <500mW <500mW
Type of Load R – L – C R
Thermal shutdown 2) 150°C -
D-PWM dimming frequency 300Hz 300HZ
D-PWM resolution 16 bit 16bit
D-PWM range 0,1 – 100% 0,1 – 100%
Storage Temperature min: -40 max: +60 °C min: -40 max: +60 °C
Ambient Temperature 1) min: -10 max: +40 °C min: -10 max: +40 °C
Protection grade IP20 IP20
Wiring 2.5mm² solid – 2.5mm² stranded - 30 12 AWG 1.5mm² solid - 1mm² stranded - 30 16 AWG
Wire preparation length 5.5 ÷ 6.5 mm 5 ÷ 6mm
Mechanical dimensions 44 x 57 x 25 mm 44 x 57 x 19 mm
Package dimensions 56 x 68 x 35 mm 56 x 68 x 35 mm
Casing material Plastic Plastic
Weight 40g 38g
1) maximum value, dependent on the ventilation conditions. This value is measured at 40°C, it is maximum ambient temperature.
2)The Temperature Protection, in case of high temperature, is detected by transistor (> 150°C) and is only on the output channel.
DLM single channel
LED DRIVERS
DALCNET S.r.l.
Registered office: via Meucci, 35 - 36040 Brendola (VI) - Italy
Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy
Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453
VAT: IT-04023100235
info@dalcnet.com www.dalcnet.com

DLM Single Channel
Multi INPUT
EASY LINE
Device Manual FW 1.0
Made in Italy
Rev. 2018-07-30
pag. 3 7
➢ INSTALLATION
To set the product, follow the instruction on the picture below:
1) connect the power supply (12-24 Vdc or 12-48Vdc depending on the dimmer model) to terminal blocks “DC IN” of the device.
2) connect the LOCAL COMMAND to the terminal blocks “INPUT” of the device.
3) connect the LED in the output terminal blocks “OUT” of the device.
DLM1248-1CV DLM1224-1CV
DLM single channel
LED DRIVERS
DALCNET S.r.l.
Registered office: via Meucci, 35 - 36040 Brendola (VI) - Italy
Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy
Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453
VAT: IT-04023100235
info@dalcnet.com www.dalcnet.com
SWITCHING
SU LY
SELV
+-
Vout
LN
230V
Pow r Supply
N.O USH
BUTTON
0-10V
COMMAND
1-10V
COMMAND
OTENTIOMETER 10K
IN 0V IN 0V
DLM-1CV
In: 12-24V
Out: 10A
DC IN OUT
INPUT
COM
SYNC
TX RX
DLM-1CV
In: 12-24V
Out: 10A
DC IN OUT
INPUT
COM
SYNC
TX RX
DLM-1CV
In: 12-24V
Out: 10A
DC IN OUT
INPUT
COM
SYNC
TX RX
DLM-1CV
In: 12-24V
Out: 10A
DC IN OUT
INPUT
COM
SYNC
TX RX

DLM Single Channel
Multi INPUT
EASY LINE
Device Manual FW 1.0
Made in Italy
Rev. 2018-07-30
pag. 4 7
➢PUSH DIMMER FEATURE
The intensity and the status change (ON/OFF) are controlled by the N.O. push button.
Button Intensity
Click
Double Click
Long pressure (>1s) from OFF
Long pressure (>1s) from ON
On Off
Maximum intensity
Turn ON at 1% (Nightly Time), then dimmer up down
Dimmer up down
15 Click in 5 second-time Enter in to PUSH MENU’
➢0-10V & 1-10V & POTENTIOMETER FEATURE
The intensity is controlled by input voltage variation.
Input Function Intensity
0÷10V
1÷10V
Potentiometer
Dimmer: 0-1V = 0% 10V=100%
➢PUSH MENU’
•FUN TIONS AVAILABLE
- MINIMUM VALUE OF DIMMING
- POWER-ON RAMP (FADE IN)
- POWER-OFF RAMP (FADE OUT)
•A ESS TO MENU’
When you turn-on the LED dimmer, the output is set at 100% and the minimum of dimming is at 1%.
To access the device menu, click the push button 15 times in 5 seconds-time.
When the Load flashes, you are in “MENU 1”.
•MENU’ 1 – MINIMUM VALUE OF DIMMING
Every single click make it changing the minimum value of dimming
There are six levels of minimum: 0,1%, 1%, 5%, 10%, 20%, 30% and 100%
After setting the minimum value of dimming press long to confirm.
A double flashing confirms the storage and you can go to “MENU’2”
Note: if you set the minimum level to 100%, once the setting is confirmed, the device automatically exits the MENU.
•MENU’ 2 – POWER-ON RAMP (FADE IN)
Every single click make it changing the power-on ramp
There are five levels of power-on ramp (FADE IN): instantaneous, 1 second, 2 seconds, 3 seconds, 6 seconds.
After setting the FADE IN press a long to confirm.
Three flashes confirm the storage and you can go to “MENU’3”
•MENU’ 3 – POWER-OFF RAMP (FADE OUT)
Every single click make it changing the power-off ramp
There are five levels of power-off ramp (FADE OUT): instantaneous, 1 second, 2 seconds, 3 seconds, 6 seconds.
After setting the FADE OUT press long to confirm.
Three quick flashes confirm the storage and you go out from the “DEVICE MENU’”
When you are out of the Menu’, the Lamp which is connected to the LED Dimmer turns on at the minimum level of dimming previously set.
DLM single channel
LED DRIVERS
DALCNET S.r.l.
Registered office: via Meucci, 35 - 36040 Brendola (VI) - Italy
Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy
Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453
VAT: IT-04023100235
info@dalcnet.com www.dalcnet.com
N
E
W
P
U
S
H
M
E
N
U

DLM Single Channel
Multi INPUT
EASY LINE
Device Manual FW 1.0
Made in Italy
Rev. 2018-07-30
pag. 5 7
➢LOCAL COMMAND
AUTOMATIC DETECTION OF THE TYPE OF LOCAL COMMAND
At the first switch the device is set by default to automatic recognition of push button N.O. command.
✔AUTOMATIC DETECTION OF THE 0 1-10V & POTENTIOMETER COMMAND
The automatic recognition of analog signal 0 1-10V or potentiometer starts as soon as a 0 1-10V value between 3V and 7V is sent out or setting the
potentiometer with a value included from 30% and 70%.
COMMAND 0-10V COMMAND 1-10V POTENTIOMETER
✔AUTOMATIC DETECTION OF THE N. O. PUSH BUTTON COMMAND
The N.O. push button is identified automatically after 5 clicks in rapid sequence. In mode N.O. push button, function memory is always active.
PUSH BUTTON N.O.
DLM single channel
LED DRIVERS
DALCNET S.r.l.
Registered office: via Meucci, 35 - 36040 Brendola (VI) - Italy
Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy
Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453
VAT: IT-04023100235
info@dalcnet.com www.dalcnet.com
IN COM
INPUT
0-10V
+ -
SYNC
TX RX IN COM
INPUT
1-10V
+ -
SYNC
TX RX
POTENTIOMETER
10KΩ
IN COM
INPUT SYNC
TX RX
IN COM
INPUT SYNC
TX RX
M
U
L
T
I
I
N
P
U
IN
A
N
A
L
O
G
I
C
A
U
T
O
M
A
T
I
C
D
E
T
E
C
T
I
O
PA TENT
PENDING

DLM Single Channel
Multi INPUT
EASY LINE
Device Manual FW 1.0
Made in Italy
Rev. 2018-07-30
pag. 6 7
➢SYNC INSTALLATION
SYNC FUNCTION WITH SINGLE POWER SUPPLY
It is possible to connect multiple device of the family DLM-1CV among them in mode Master Slave.
Connect the local command desired to the device used as Master. Connect master “TX” signal to the “RX” entrances of slave.
Example of Master Slave.
SYNC FUNCTION WITH ONE POWER SUPPLY FOR DIMMER
In the case multiple power supplies are used to power “master” dimmer and “slave” dimmers, connect all the “COM” inputs of the LedDimmer to each
other.
NOTE FOR MASTER / SLAVE INSTALLATION
1) Using one power supply every single dimmer, first power on the Master unit and after that give power to the Slave.
2) When doing maintenance on the installation take care of shutting down power to the Slave units first and than to the Master.
3) When power to the Master unit is missing, the Slave set up automatically to the default ex-factory settings (power on 100%) or to the settings
previously saved.
DLM single channel
LED DRIVERS
DALCNET S.r.l.
Registered office: via Meucci, 35 - 36040 Brendola (VI) - Italy
Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy
Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453
VAT: IT-04023100235
info@dalcnet.com www.dalcnet.com
SWITCHING
SU LY
+-
Vout
L N
230V
Pow r Supply
Local Command
DLM-1CV
In: 12-24V
Out: 10A
DC IN OUT
INPUT
COM
SYNC
TX RX
DLM-1CV
In: 12-24V
Out: 10A
DC IN OUT
INPUT
COM
SYNC
TX RX
DLM-1CV
In: 12-24V
Out: 10A
DC IN OUT
INPUT
COM
SYNC
TX RX
MASTER SLAVE SLAVE
Pow r
Supply
Local Command
DLM-1CV
In: 12-24V
Out: 10A
DC IN OUT
INPUT
COM
SYNC
TX RX
DLM-1CV
In: 12-24V
Out: 10A
DC IN OUT
INPUT
COM
SYNC
TX RX
DLM-1CV
In: 12-24V
Out: 10A
DC IN OUT
INPUT
COM
SYNC
TX RX
MASTER SLAVE SLAVE
SWITCHING
SU LY
+-
Vout
LN
230V
SWITCHING
SU LY
+-
Vout
LN
230V
SWITCHING
SU LY
+-
Vout
L N
230V

DLM Single Channel
Multi INPUT
EASY LINE
Device Manual FW 1.0
Made in Italy
Rev. 2018-07-30
pag. 7 7
TECHNICAL NOTE
Installation:
• Installation and maintenance must be performed only by qualified personnel in compliance with current regulations.
• The product must be installed inside an electrical panel protected against overvoltages.
• The product must be installed in a vertical or horizontal position with the cover label upwards or vertically; Other positions are not permitted. It is not
permitted to bottom-up position (with the cover label down).
• Keep separated the circuits at 230V (LV) and the circuits not SELV from circuits to low voltage (SELV) and from any connection with this product. It is
absolutely forbidden to connect, for any reason whatsoever, directly or indirectly, the 230V mains voltage to the bus or to other parts of the circuit.
Power Supply:
• For the power supply use only a SELV power supplies with limited current, short circuit protection and the power must be dimensioned correctly.
In case of using power supply with ground terminals, all points of the protective earth (PE = Protection Earth) must be connected to a valid and certified
protection earth.
• The connection cables between the power source "low voltage" and the product must be dimensioned correctly and they should be isolated from every
wiring or parts at voltage not SELV. Use double insulated cables.
• Dimension the power supply for the load connected to the device. If the power supply is oversized compared with the maximum absorbed current, insert
a protection against over-current between the power supply and the device.
Command:
• The length of the connection cables between the local commands (N.O. Push button, 0-10 V, 1-10 V, Potentiometer or other) and the product must be
less than 10m; the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Use double insulated
shielded and twisted cables.
• The length and type of the connection cables at the BUS SYNC must be less than 3m and they should be isolated from every wiring or parts at voltage
not SELV. It is suggested to use double insulated shielded and twisted cables.
• All the product and the control signal connect at the bus and at the local command (N.O. Push Button, 0-10V, 1-10V, Potentiometer or other) must be
SELV (the devices connected must be SELV or supply a SELV signal)
Outputs:
• The length of the connection cables between the product and the LED module must be less than 10m; the cables must be dimensioned correctly and
they should be isolated from every wiring or parts at voltage not SELV. It is suggested to use double insulated shielded and twisted cables.
➢MECHANICAL DIMENSION
DLM1224-1CV DLM1248-1CV
DLM single channel
LED DRIVERS
DALCNET S.r.l.
Registered office: via Meucci, 35 - 36040 Brendola (VI) - Italy
Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy
Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453
VAT: IT-04023100235
info@dalcnet.com www.dalcnet.com
1,1
2,6
7,5
25
5,1 19,4
5,2
57,2
44,4
42,2
1,8
2,5Ø
5,1
2,3
57,6
7
B-B
Self-tapping screws countersunk head
d2.9x6.5 mm
Screws for pressed wood or chipboard
d2.5 mm for dowel fixing to wall
5,1
2,5Ø
5,1
57,2
42,8
44,4
57,6
1,8
15
5,3 0,5
19
13,4
2,6
1,6
1,1
R1,3
7,5
Other manuals for DLM Series
1
This manual suits for next models
2
Table of contents
Popular I/O System manuals by other brands

Allen-Bradley
Allen-Bradley POINT I/O 1734-IE2C installation instructions

National Instruments
National Instruments PXIe-7856R user manual

ICPDAS
ICPDAS WinCon-8000 Getting started

Omega Engineering
Omega Engineering 100/200 Series user manual

Johnson Controls
Johnson Controls IOM3711 installation instructions

Allen-Bradley
Allen-Bradley 1746 Series installation instructions