QUICK GUIDE
BREEZER - ADIABATIC COOLER
Delta-Temp Belgium
Lange Ambachtstraat 13, 9860 Oosterzele
T: +32 (0)9 362 74 87
www.delta-temp.be
Delta-Temp Germany
Carl-Still-Straße 19, 45659 Recklinghausen
T: +49 800 4048120
www.delta-temp.de
1. Mounting the fan head:
• Lock each of the rear wheels by pressing down
on the brakes.
• Lift the fan head straight up and out of the tank
and align it with the fan head support pole.
• Turn the fan head until you feel it engage.
• Once installed, the atomizer (metal disk) will be
facing the tank, air will be blown over the tank
when the unit is turned on.
3. Insert water inlet hose:
• Remove water inlet hose from the front hole in
the tank and insert into bulkhead tting. Ensure
that connection is sealed.
2. Fan Head power connector
• Insert fan head power connector into fan head.
Ensure female end of power connector is aligned
to male connector and twist together.
4. Insert atomizer drain hose:
• Insert atomizer drain hose into the front hole
on top of the tank, from where the water inlet
hose was originally removed.
• Atomizer drain hose should not be submerged
below water line.
• Once assembled, the atomizer drain hose should
be exible, but not so loose that water gets
backed up in the hose.
I. SETUP
>>