Deye DGWA2-ACDCBLW12K User manual

Photovoltaic DC/AC Split System Air Conditioner
Installation Manual

Revision 10 Nov 2020 Page 1 of 32
Table of contents
Contents
Table of contents ................................................................................................................................... 1
Table of Revisions ................................................................................................................................. 2
Model Applicability ................................................................................................................................. 2
Equipment description ........................................................................................................................... 3
Accessories ............................................................................................................................................ 2
Standards reference .............................................................................................................................. 4
Disclaimer .............................................................................................................................................. 4
Symbols used ........................................................................................................................................ 4
Safety Precautions ................................................................................................................................. 5
Indoor unit mounting instructions ........................................................................................................... 6
Outdoor unit mounting Instructions ........................................................................................................ 8
Outdoor unit required clearances .......................................................................................................... 8
Refrigerant pipe Specifications .............................................................................................................. 9
Refrigerant fill capacity .......................................................................................................................... 9
Maximum Length of piping ................................................................................................................... 10
Addition of refrigerant per pipe length .................................................................................................. 10
Connecting the Refrigerant piping ....................................................................................................... 10
Pressure Testing the System ............................................................................................................... 11
Evacuate the System ........................................................................................................................... 11
Releasing the refrigerant into the system ............................................................................................ 12
Electrical Connections ......................................................................................................................... 13
Installation of Solar Modules ................................................................................................................ 14
Solar Array Maximum Voltage. ............................................................................................................ 14
Solar Array maximum current .............................................................................................................. 15
Galvanic considerations outdoor unit. .................................................................................................. 15
Solar Module installation ...................................................................................................................... 15
Solar Array Mechanical installation ...................................................................................................... 18
Solar Array Wiring ................................................................................................................................ 20
Earth Fault Protection Solar DC .......................................................................................................... 22
Signage ................................................................................................................................................ 23
Solar Disclaimer ................................................................................................................................... 22
Electrical and Gas Leak checks. .......................................................................................................... 24
Gas Leak checks ................................................................................................................................. 24
Electrical Safety checks ....................................................................................................................... 24
Test Run .............................................................................................................................................. 25
Maintenance ........................................................................................................................................ 26
Operation ............................................................................................................................................. 27
Remote control operation ................................................................................................................. 27
Android or I phone app .................................................................................................................... 29
Troubleshooting and Repair ................................................................................................................ 30

Revision 10 Nov 2020 Page 2 of 32
Table of Revisions
Table of Revisions
Revision Date
Reason for revision
Revision By
10 November
Initial writing
George Abernathy
Model Applicability
This manual applies to the following models
Table of Models
Model
DGWA2-ACDCBLW-
12K
DGWA1-ACDCBLW-
18K
DGWA1-ACDCBLW-
24K
Indoor unit
DGA2-ACDCBLW-12K
DGA1-ACDCBLW-18K
DGA1-ACDCBLW-24K
Outdoor
unit
DWA3-ACDCBLW-12K
DWA3-ACDCBLW-18K
DWB2-ACDCBLW-24K
Accessories
Components Supplied
Number
Quantity
Name
1
1
Indoor unit
2
1
Indoor unit Mounting plate
3
1
Remote Controller
4
2
AAA battery
5
1
Connecting cord 3 meters
6
1
Outdoor unit
7
1
Connecting pipe 3 meters
8
1
Connecting wire 3 meters
9
1
Wrapping tape weather protection
10
1
Drainpipe 1.5 meters 15 mm diameter
11
1
Wall sleeve
12
1
Sealant putty
13
1
User Manual
14
1
Installation manual
15
1
MC 4 style connector set for outdoor unit

Revision 10 Nov 2020 Page 3 of 32
Equipment description
The equipment consists of an indoor unit and an outdoor unit air conditioning system. The
system produces heating or cooling as required.
The system can be powered in several ways.
•By DC solar alone. It will start up and run on just the solar
•By DC solar and a small amount of AC 240 Volt power.
•By AC 240 volt only. This would be applicable at night.
Installation is the same as a standard split system air conditioner with the addition of Solar
PV modules to supply the DC input.
The system is controlled by an optical remote control.

Revision 10 Nov 2020 Page 4 of 32
Standards reference
The standards listed here may not be all applicable standards. Check local and national standards for
additional applicability. Check for the latest revisions and clauses.
Standards
AS/NZS 1319
AS/NZS 1571
AS/ NZS 3000
As/ NZS 3500
AS/NZS 4777
AS/NZS 5033
AS/NZS 5149
IEC 62109
National construction code volume 3 plumbing code of Australia.
Australia and New Zealand Refrigerant Handling code of practice part 2
US Electrical code NEC 2005 Article 690.5 Ground fault protection
Disclaimer
This equipment requires the handling and installation of High-pressure gasses, and hazardous levels
of AC and DC voltages. Only fully qualified licenced personnel may install this equipment.
Personal Protection Equipment (PPE) must be used while installing this equipment. Care must be
taken that all required PPE and precautions are taken. The manufacturer and resellers of this
equipment assume no responsibility for any failure to properly protect personnel. Any
recommendations are only for advisory purposes.
The references to standards in this manual are advisory. Failure to follow all applicable standards will
void the equipment warranty.
All Electrical work must be performed by a licenced technician according to local regulations and the
instructions given in this manual.
The illustrations in this manual are for explanatory purposes. The actual shape of your units may be
slightly different.
Symbols used
General Warnings beware of a hazard and take preventative measures
Freezing and frost bite, beware escaping refrigerant and take preventative
measures
High voltage or Electric Shock. Make certain that all electrical circuits are not
energized
Explosion risk, High pressure gasses used in testing and operation
High pressure gas bottle Caution risk of electric shock
This manual suits for next models
8
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual