Dhatec Pipe Hook Premium User guide

Elskensakker 8, NL-5571 SK
Bergeijk, The Netherlands
Tel +31 497 542 527
Fax +31 497 555 399
Web www.dhatec.nl
Page 1of 7
Application Procedure Specification Dhatec Pipe Hook
Dhatec Document No.: DHA415-APS-PH
Rev.
Date
Status
Prepared by
Reviewed by
Approved by
00
08.04.2015
For Construction
M.Hol
A.S.Sridharan
A.S.Sridharan
01
20.01.2016
For Construction
M.Hol
D.Neutkens
I.v.Assema
02
29.01.2018
For Construction
M.Voets
M. Bayens
M. Bayens
©Dhatec BV. The following document shall be considered as copyright and the design right reserved. Copying and/or disclosure of
the information contained within the following document to any third-party, other than specifically for the purpose of the project is
forbidden without prior written permission of the proprietor.

Elskensakker 8, NL-5571 SK
Bergeijk, The Netherlands
Tel +31 497 542 527
Fax +31 497 555 399
Web www.dhatec.nl
Page 2of 7
Change Record
Rev.
Description of Revision
00
First Issue
01
General update + layout
02
Font style

Document Ref: DHA415-APS-PH
Revision: 02
Page 3of 7
General Information
Equipment
Pipe Hook
Supplier Name
Dhatec B.V.
Telephone No.
+31 497 542 527
Fax No.
+31 497 555 399
Contact email address
Disclaimer of liability: Every effort has been made to ensure that the information in this document is accurate and
correct to the best of our knowledge, correct at the date of publication. However, Dhatec B.V. cannot be held
responsible for consequences that follow from the claims that were made in this document.
Do not carry out any repairs or modifications on the equipment without consulting Dhatec B.V., doing so will invalidate
the guarantee. The guarantee is also invalidated if accidents and damage of any form are caused as a result of
improper use and/or not obeying the warnings in general as explained in this user guide. Dhatec B.V. accepts no
responsibility for any personal accidents as a consequence of not following the safety instructions and warnings.
This is also the case for consequential loss in any form.

Document Ref: DHA415-APS-PH
Revision: 02
Page 4of 7
Safety Requirements
These are general guidelines, all personnel involved should adhere to the safety requirements of the particular
location at which they are performing their operations.
Dhatec recommends wearing of suitable PPE while handling their products. This includes gloves, safety shoes,
safety glasses, safety helmet, hearing protection and suitable work clothing.
The working areas should be kept tidy at all times in order to minimize the risk of trips and slips.
All personnel involved should use suitable manual handling techniques and follow industry recommended
guidelines for lifting and moving, such as those described in “Ergonomic Guidelines for Manual Material Handling”
published by the National Institute for Occupational Safety and Health (Publication 2007-131), or those otherwise
prescribed by the client.
The Pipe Hooks are exclusively for horizontal lifting and transporting of pipes. The Pipe Hooks can only be used in
pairs while using a two-leg sling or spreader beam. All the Pipe Hooks and Shackles supplied by Dhatec, are
provided with a unique registration mark. Never use a Pipe Hook or Shackle without these registration marks or
when there is no valid test certificate available.
The operating temperature of the Dhatec Pipe Hooks is between -30 ⁰C (-22 ⁰F) and +80 ⁰C (176 ⁰F). For other
ambient temperatures, contact Dhatec.

Document Ref: DHA415-APS-PH
Revision: 02
Page 5of 7
Equipment
The Pipe Hook Premium (figure 1.) is available
with a WLL of 5 ton/set up to 60 ton/set.
The Pipe Hook Standard (figure 2) is available
with a WLL of 4 ton/set up to 20 ton/set.
The Main Shackle (figure 3) is used to connect the Premium
Pipe Hook to the chain or sling of the crane. A Shackle
Protector (figure 4) is used to prevent damage to the pipe or
coating that can be caused by the shackle.
To extend the lifetime of the Pipe Hooks, they must be stored in a dry and
clean environment. The Pipe Hook Box (figure 5) can be used to store the
Pipe Hook in a proper way.
If the plastic covers of the Pipe Hooks are damaged, they can be replaced
with the Replacement Cover Set (figure 6). For replacement, use only
original Dhatec parts. The cover sets are available for the Pipe Hook
Premium and Pipe Hook Standard.
Figure 5. Pipe Hook Box
Figure 6. Replacement Cover Set
Figure 1. Pipe Hook Premium
Figure 2. Pipe Hook Standard
Figure 3. Main Shackle
Figure 4. Shackle Protector

Document Ref: DHA415-APS-PH
Revision: 02
Page 6of 7
General instructions for lifting with Dhatec Pipe Hooks
-Before lifting check if the working load limit of the Pipe Hook and main Shackle is sufficient for the weight of
the pipe. The Pipe Hook Standard comes with a shackle pin whereas Pipe Hook Premium is to be used
together with a main shackle provided by Dhatec.
-Remove grease and dirt from the Pipe Hook and Shackle so the equipment can be checked properly.
-Check visually if the Pipe Hook or shackle is damaged, cracks or deformation (which is indicative of overload).
In case of any doubts, please contact Dhatec before using the equipment.
-Inspect the plastic parts of the Pipe Hook for wear and defects (the plastic parts must be free of contamination,
dry and undamaged). The plastic parts must be replaced when the wear and tear or damages exceeds 10mm.
-Each type of Pipe Hook has its specific lifting angle. Below you can find the required lifting angles for the Pipe
Hook Standard and Pipe Hook Premium.
-Connect the Pipe Hook to the lifting equipment (make sure all attachment devices are approved and certified
for the corresponding tonnage).
-Place the Pipe Hook as deep as possible in the pipe, until it sits firmly in the back end of the jaws. Make sure
that the hook is positioned in such a way as to balance the load when it is being lifted.
-Lift steadily to allow effective gripping by the Pipe Hooks.
-Make sure the load is stably positioned before the Pipe Hooks are removed.
Pay attention to your own safety and to that of people around you!
Keep a safe distance during lifting operations and never walk or stand under a lifted load.
Figure 7. Lifting angle Pipe Hook Standard
Figure 8. Lifting angle Pipe Hook Premium
α
α
α= 0° - 60°
α= 30° - 90°

Document Ref: DHA415-APS-PH
Revision: 02
Page 7of 7
Guidelines to check if the Pipe Hook is applied properly
The Pipe Hook should be positioned leveled in the pipe end before starting lifting:
The Pipe Hook must be placed completely inside the pipe until it sits firmly in the back end of the Pipe Hook:
-The Pipe Hook should be
leveled in the pipe end.
-The horizontal part must
be in full contact with the
internal surface of the
pipe.
-There should be no
distance between the
pipe and vertical part of
the Pipe Hook.
This manual suits for next models
1
Table of contents