Dormakaba Muto Comfort M50 User manual

Muto Comfort M50
Ceiling mount less Dormotion
Installation instructions
936021 – 05-2018
| EN |

2MUTO Comfort 05-2018
936021
dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
Table of Contents
Table of contents
1 Technical specifications 3
. Overview
.. General information
.. Intended use
.. Glass requirements and fittings
.. Requirements for glass panel
.. Safety instructions
.. Symbols used - Safety/Installation
.. Maintenance, care, repair
.. Disposal
2 Installation instructions 4
. Overall
. Securing track to mounting surface
. Door/wall dimensions
. Specifications - technical data
. Installing roller carriers:
on monolithic glass ONLY
. Installing end stops
. Install glass/rollers in track
. Engaging anti-jump
. Install floor guide
. Install floor guide: continued
. Adjustment door height
. Adjustment end stop location:
LEADING end stop
Adjustment end stop location:
TRAILING end stop
. Cover clips
. Install brush profile
. Install cover
. Install end caps

dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort 05-2018936021 3
Technical specifications
. Overview
These instructions are for installation of MUTO
COMFORT sliding door system M for the following
mounting and style versions:
1. Ceiling mount
.. General information
• dormakaba requires use of tempered monolithic or
tempered laminated glass.
• dormakaba glass hardware is not suitable for
application in rooms where chemicals (e.g. chlorine)
are used as indoor swimming pools, saunas or
salt-water pools.
• Never move sliding panels faster than walking
speed and always stop the door manually before it
reaches end position.
• Do not slide doors with excessive force. Install
limiting stop to prevent door from opening too far.
.. Intended use
• For sliding door in dry indoor areas only
• For manual slowly opening and closing only
.. Glass requirements and fittings
• The substructure/wall must be able to bear
permanent loads and be level (max. tolerance:
/” [] per ” [m]).
• Fasteners must be sufficiently dimensioned for the
substructure/wall and weight of the door.
• When adjusting glass components, always stick to
the required clearance for the respective
hardware. Adjust clearance so glass does not
come in contact with any hard surfaces such as
glass, metal or concrete.
• Do not use excessive force when installing the
glass (avoid over tightening screws).
.. Requirements for glass panel
• dormakaba requires use of fully tempered glass,
which complies with ASTM C and ASTM C
. Secondary heat soaking processes are
recommended but not required. This applies to
both tempered monolithic and tempered laminated
glass.
• Clamping area must be flat and uncoated (no
self-cleaning coating!)
• Never use glass with conchoidal fractures and/or
damaged edges.
.. Safety instructions
• Installation requires two people.
• Only properly qualified and specially trained staff
are authorized to mount dormakaba glass
hardware.
• Due to crushing hazards and possible injury caused
by breakage of glass during mounting,
corresponding protective clothing (especially gloves
and protective goggles) is required.
• Never clamp metal fitting hardware directly to
glass surface.
.. Symbols used - Safety/Installation
CAUTION
Mounting components must meet the
requirements of substructure/wall and door
weight. Please read the technical information
for fittings.
WARNING
Risk of breaking glass. When installing the
door, support the door panel with a block of
wood or similar object.
TIPS AND RECOMMENDATIONS
Information note
CLOSING EDGE
.. Maintenance, care, repair
• Immediately replace damaged parts.
• Always use original dormakaba parts.
• Clean clamping area with alcohol-based standard
commercial cleaning agent before mounting the
glass hardware.
• Use a damp clothe for occasional cleaning,
especially the track.
• Always use silicone - and oil-free cleaners (e.g.
acetone).
• Check glass hardware at regular intervals for
proper positioning and smooth operation and
correct adjustment.
• High traffic door systems require inspection by
properly qualified staff (specialized companies or
installation firms.)
.. Disposal
Disposal in accordance with local, state and national
regulations.
1 Technical specifications

dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort 05-2018936021
4
Overall
. Cover
. Brush strip
. Track
. End cap
. Overall
2 Installation instructions
. End stop
. Cover clips
. Roller carrier
. Floor guide
.
..
.
.
.
.
.
. .. .

dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort 05-2018936021 5
Track
Track
NOTE:
OVERHEAD REINFORCEMENT:
The overhead reinforcement must be a minimum of ¼”
[6] x 3” [76] steel angle, 16 gauge metal stud, or two
pieces of 1 1/2” [38] thick wood blocking (double
stacked), secured to studs or joists on a maximum 16”
[406] centers for the length of the track. The overhead
reinforcement may be flush on the overhead surface or
on the interior of this surface.
Track mounting screws must fully penetrate the steel
angle, metal stud, or at a minimum of 2” [51] into wood
blocking, utilizing the predrilled holes in the MUTO
track.
Consult with a structural engineer to determine if
reinforcement is adequate for your specific application
or to meet specific codes in your location.
.. Ensure the track is properly level and secure it to
the ceiling per the appropriate measurements on
the following page.
• NOTE: SEE DIMENSION INSTRUCTIONS ON NEXT
PAGE FOR REFERENCE.
.. Use appropriate fasteners according to the
following recommendations.
. Securing track to mounting surface
Fig

dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort 05-2018936021
6
Technical specifications
Single door mount
-/"
[]
-/"
[]
clear
opening
height
(CH)
clear opening
width (CW)
Glass
door
Glass
door
panel
(DW)
/"
[]
Bottom of
glass to floor
Back of track to
center of mounting
hole in track
"
[]
Single Door
M50
Ceiling
mount
Door leaf weight lbs [kg] * ≤lbs
[≤]
* Including weight of auxiliary hardware.
. Door/wall dimensions
. Specifications - technical data

dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort 05-2018936021 7
Roller carriers
End stops
.. Slide roller carriers onto glass.
.. Slide glass gasket and metal shim between
glass and roller carrier.
NOTE: Orient gasket with rubber side facing the glass.
.. Secure roller carriers to glass using appropriate-
size hex key at ft lbs [ Nm].
DETERMINE THE LEADING (X) VERSUS TRAILING (Z) EDGE OF THE GLASS.
"LEADING IS SIDE CLOSEST TO LATCH CLOSED."
Secure Legend
Closing edge
of door
Hex key size
M mm
[Back of] Glass [Back of] Glass
X
Z
-/”
[]
-/”
[]
Glass
gasket
Roller
carrier
. Installing roller carriers: on monolithic glass ONLY
Fig
.. Slide end stops into each end of the track.
NOTE: DO NOT FULLY TIGHTEN.
NOTE: Exact location/adjustments will be determined in
“Adjustment End Stop Location” step.
Hex key size
M mm, .mm
Track
End stops
. Installing end stops
Fig
NOTE: FULLY CLEAN SURFACE OF GLASS WITH AN ALCOHOL-BASED MILD GLASS AND SURFACE
CLEANER.
ENSURE GASKET IS FREE OF DEBRIS.
ENSURE ROLLER CARRIER WHEELS ARE FREE OF DEBRIS.

dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort 05-2018936021
8
Track
Anti-jump
.. Place glass on setting blocks on floor for
stability.
.. Tip glass and rollers upward and rest rollers on
track.
ENSURE ROLLERS AND TRACK ARE FREE OF DEBRIS.
Setting blocks
. Install glass/rollers in track
Fig
.. Temporarily engage anti-jump on roller carrier. .. Using appropriate-size ball-end hex key, turn
adjustment screw CLOCKWISE to engage
anti-jump.
Hex key size
M mm
Anti-
jump
Anti-jump
adjustment
screw
. Engaging anti-jump
Fig
Rollers

dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort 05-2018936021 9
Floor guide
Glass
.. Align centerline of glass with centerline of floor
guide.
.. Be sure the glass is plumb.
.. Mark appropriate floor guide measurements.
.. DISENGAGE ANTI-JUMP.
.. TEMPORARILY REMOVE GLASS AND
ROLLERS FROM TRACK.
.. Pre-drill into mounting surface using a /"
drill bit.
.. Secure floor guide anchor with included
fasteners.
Glass
X
Floor
guide
M50
X1-1/4” - (T/2)
[31.5 - (T/2)]
Floor
guide
anchor
1-7/16"
[36]
13/16"
[20]
Wall
T
. Install floor guide
Fig
.. SET GLASS AND ROLLERS BACK ONTO
TRACK.
.. Slide floor guide over floor guide anchor and
tighten with set screws.
.. Remove setting blocks.
NOTE: Be sure glass is centered in floor guide.
.. Adjust using set screws.
Floor
guide
Floor
guide
anchor
Glass
Set screws
Hex key size
M .mm
. Install floor guide: continued
Fig

dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort 05-2018936021
10
Height adjustment
.. Set height of glass door.
.. Using appropriate-size hex key, turn height
adjustment screw CLOCKWISE or COUNTER-
CLOCKWISE to raise or lower glass.
NOTE: Be sure glass is level during this adjustment.
.. Re-engage anti-jump by turning anti-jump
adjustment screw CLOCKWISE.
NOTE: Anti-jump should NOT touch track.
Door height
adjustment tolerance
M
+/" [+]
-/" [-]
Glass
Floor
guide 3/8"
[10]
==
Hex key size
M .mm
Anti-jump
adjustment
screw
[ < X < /" (.)]
X
Height
adjustment
screw
. Adjustment door height
Fig

dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
End stops
MUTO Comfort 05-2018936021 11
M
torque
ft lbs
[ Nm]
NOTE: bi-folding:
Be sure there is a
1/4” [6] gap between
the right and left hand
sets.
Set end stop locations:
.. Slide end stop
to desired
location on
track. Bumper
should touch
edge of roller
carrier.
Hex key size
M mm,
.mm
Set end stop locations:
.. Slide end stop
to desired
location on
track. Bumper
should touch
edge of roller
carrier.
NOTE: bi-folding:
Be sure there is a
1/4” [6] gap between
the right and left hand
sets.
mm
END STOP LOCATION:
LEADING EDGE
Bumper Edge of roller
carrier
End
stop
Door closed
Door
pull
Jamb
edge
Glass
edge
max. -/"
[]
Glass overlap
on wall
Door pull to jamb distance.
*Verify with local jurisdiction.*
Bumper
Secure
Bumper
Secure
Hex key size
M mm,
.mm
M
torque
ft lbs
[ Nm]
Door opened
mm
Jamb
edge
Glass
edge
END STOP LOCATION:
TRAILING EDGE
Bumper
Edge of
roller
carrier
End
stop
Door pull to jamb distance.
*Verify with local jurisdiction.*
Door
pull
. Adjustment end stop location: LEADING end stop
Adjustment end stop location: TRAILING end stop
Fig
Fig

dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort 05-2018936021
12
Cover clips
Brush profile
.. Insert cover clips into track. (One clip per foot) .. Insert perpendicular to track, and turn
CLOCKWISE to snap into place.
.. Measure and cut brush to appropriate length. .. Slide brush into track.
Cover
clip
Brush
Track
. Cover clips
. Install brush profile
Fig
Fig

dormakaba MUTO M50 Ceiling Mount less Dormotion
Installation Instructions
MUTO Comfort 05-2018936021 13
Cover
End caps
.. Secure cover to clips and snap into place. NOTE: Roll cover from the bottom upwards. Ensure the
bottom of the cover is supported by the groove in the
cover clip.
.. Snap end caps onto track.
End
cap
End
cap
Cover
. Install cover
. Install end caps
Fig
Fig
Cover
Cover
clip

www.dormakaba.com
dormakaba USA, Inc.
1 Dorma Drive, Drawer AC
Reamstown, PA 17567
USA
T: 717-336-3881
F: 717-336-2106
Table of contents
Other Dormakaba Rack & Stand manuals