Drazice AIR 2,6 kW Specification sheet

CAREFULLY READ THIS MANUAL BEFORE INSTALLING!
Dear Customer,
The Works Cooperative of Dražice - Machine Plant, Ltd., would like to thank you for your decision to use
a product of our brand.
The product is not intended to be controlled by
a) people (including children) with reduced physical, sensual or mental capacities, or
b) people with insufficient knowledge and experiences unless supervised by responsible person,
or unless properly instructed by such responsible person.
CONTENTS
Safety instructions 3
Preparation before use 4
Safety Precautions 5
Installation instruction 14
Installation diagram 14
Select the installation locations 15
Connecting of the cable 16
Wiring diagram 17
Outdoor unit installation 18
Air purging 18
Please read this use and installation instructions carefully before installing and using this appliance
and keep this manual for future reference.
Caution: Risk of fire / flammable materials
WARNING: Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be carried out
under the supervision of the person competent in the use of flammable refrigerants.

- 3 -
•To guarantee the unit work normally, please read the manual carefully before
installation, and try to install strictly according to this manual.
•Do not let air enter the refrigeration system or discharge refrigerant when moving the
air conditioner.
•Properly ground the air conditioner into the earth.
•Check the connecting cables and pipes carefully, make sure they are correct and firm
before connecting the power of the air conditioner.
•There must be an air-break switch.
•After installing, the consumer must operate the air conditioner correctly according
•to this manual, keep a suitable storage for maintenance and moving of the air
conditioner in the future.
•Fuse of indoor unit: T 3.15A 250VAC.
•For 2,6 kW~3,5 kW models, fuse of outdoor unit: T 15A 250VAC.
•For 5,3kW models, fuse of outdoor unit: T 20A 250VAC
•The installation instructions for appliances that are intended to be permanently
connected to fixed wiring and have a leakage current that may exceed 10 mA, shall
state that the installation of a residual current device (RCD) having a rated residual
operating current not exceeding 30 mA is advisable.
•Warning: Risk of electric shock can cause injury or death: Disconnect all remote
electric power supplies before servicing.
•The maximum length of the connecting pipe between the indoor unit and outdoor unit
should be less than 5 meters. It will affect the efficiency of the air conditioner if the
distance longer than that length.
•This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning use
of the appliance in a safe way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user maintenance shall not be made
by children without supervision.
•The batteries in remote controller must be recycled or disposed of properly. Disposal
of Scrap Batteries - Please discard the batteries as sorted municipal waste
at the accessible collection point.
•If the appliance is fixed wiring, the appliance must be fitted with means
for disconnection from the supply mains having a contact separation in all poles
that provide full disconnection under over voltage category III conditions, and these
means must be incorporated in the fixed wiring in accordance with the wiring rules.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons to avoid a hazard.
•The appliance shall be installed in accordance with national wiring regulations.
Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be
carried out under the supervision of the person competent in the use of flammable
refrigerants.
•The appliance shall not be installed in the laundry.
Safety instructions

- 4 -
•For the multi system, the refrigerant refers to the multi outdoor unit.
•When charging refrigerant into the system, make sure to charge in liquid state,
if the refrigerant of the appliance is R32.Otherwise, chemical composition
of refrigerant (R32) inside the system may change and thus affect performance
of the air conditioner.
•According to the character of refrigerant (R32, the value of GWP is 675), the pressure
of the tube is very high, so be sure to be careful when you install and repair
the appliance.
•If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons to avoid a hazard.
•Installation of this product must be done by experienced service technicians’
professional installers only in accordance with this manual.
•The temperature of refrigerant circuit will be high, please keep the interconnection
cable away from the copper tube.
Before using the air conditioner, be sure to check and preset the following.
•Remote Control presetting
Each time after the remote control is replaced with new batteries or is energized, remote control auto
presetting
heat pump. If the air conditioner you purchased is a Cooling Only one, heat pump remote controller can also be
used.
•Back-light function of Remote Control (optional)
Hold down any button on remote control to activate the back light. It automatically shuts off 10 seconds
later.
Note: Back-light is an optional function.
•Auto Restart Presetting
The air conditioner has an Auto-Restart function.
This appliance is made of recyclable or re-usable material. Scrapping must be carried out in compliance
with local waste disposal regulations. Before scrapping it, make sure to cut off the mains cord so that the
appliance cannot be re-used.
For more detailed information on handling and recycling this product, contact your local authorities who
deal with the separate collection of rubbish or the shop where you bought the appliance.
SCRAPPING OF APPLIANCE
This appliance is marked according to the European Directive 2012/19/EC, Waste
Electrical and Electronic Equipment (WEEE).
This marking indicates that this product should not be disposed
with other household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal,recycle it responsibly
to promote the sustainable reuse of material resources. To return your used device,
please use the return and collection systems or contact the retailer where the product
was purchased. They can take this product for environmentally safe recycling.
Preparation before use
Note
Preset
Safeguarding the environment

- 5 -
Safety precautions
Symbols in this Use and Care Manual are interpreted as shown below.
Be sure not to do.
Pay attention to such a situation.
Grounding is essential.
Warning: Incorrect handling could
cause a serious hazard, such as death,
serious injury, etc.
Use correct power supply in
accordance with the rating plate
requirement. Otherwise, serious
faults or hazard may occur, or a
fire maybe break out.
Keep the power supply circuit
breaker or plug from dirt.
Connect the power supply cord
to it firmly and correctly, lest an
electric shock or a fire break out
due to insufficient contact.
Do not use the power supply
circuit breaker or pull off the plug
to turn it off during operation.
This may cause a fire due to
spark, etc.
It is harmful to your health ifthe cool
air reaches you for a long time. It is
advisable to let the air flow be
deflected to all theroom.
Preventtheair flow from reaching
the gas burners andstove.
Do not touch the operation buttons
when your hands are wet.
Never insert a stick or similar obstacle
to the unit. Since the fan rotates at high
speed, this may cause an injury.
Do not repair the appliance by yourself.
If this is done incorrectly, it may cause
an electric shock, etc.
Do not put any objects on the outdoor
unit.
ON
OFF
SMART MODE
TEMP.
SUPER
FANSP EED
TEMP.
FE EL SLEEP
It is the user's responsibility to
make the appliance be grounded
according to local codes or
ordinances by a licenced
technician.
CLOC K TI MERON TIMER O FF
QUI ET DI M MER ECONOMY
Turn off the appliance by remote
control firstly before cutting off
power supply if malfunction occurs.
Do not knit, pull or press the power
supply cord, lest the power supply cord
be broken. An electric shock or fire is
probably caused by a broken power
supply cord.
ON
OFF
ON
OFF
This manual suits for next models
2
Table of contents
Other Drazice Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual