Dupline GAP 1605 User manual

Du line
®
Fieldbus Installationbus
Specifications are subject to change without notice (04.03.2009) 1
Dupline®is a registered trademark. A product of the CARLO GAVAZZI Group
Produc Descrip ion Ordering Key
Type:
Dupline®Programmer
Type no.
Programming Uni
Type GAP 1605
•Portable programming unit
• Individual coding of every input or output
• Group coding of an entire module
• Reading of codes
• Editing of channel codes
• On/off-line coding of Dupline®modules type G ....
• LED display 4 x 8 LEDs
• 5-key tactile keyboard
• Battery powered
•Easy-to-handle plug-type connection
• Switch for turning power on/off
Programming unit for Dupline®
modules G..(..) .... Provides
means of reading and pro-
gramming of channel codes.
Coding of I/O's as either 2, 4
and successive channels or
individually for each I/O.
Unused inputs/outputs can be
defined as non-coded.
Supply Ordering no.
Internal battery GAP 1605
Type Selec ion Supply Specifica ions
Power supply
9 V Alkaline
400 mAH
Battery type IEC 6F22
Rated operational power
Stand-by < 25 µA
Operating < 22 mA
Battery lifetime Typ. 1 year
General Specifica ions
Output
Connection 6/6 modular socket
Display 4 x dots
Type LED
Size 1. mm
Keyboard Tactile keys
No. of keys 5
Cable
GAP 1605 to Dupline®system
Connectors 2 x 6/6 modular plugs
Length 75 cm
Produc Specifica ions
Environment
Degree of protection IP 40
Pollution degree 3 (IEC 60664)
Operating temperature 0° to +50°C (+32° to +122°F)
Storage temperature -20° to +60°C (-4° to +140°F)
Humidity (non-condensing) 20 to 0% RH
Mechanical resistance
Shock 15 G (11 ms)
Vibration 2 G (6 to 55 Hz)
Material ABS, grey
Weight 225 g
GAP 1605

Du line
®
Fieldbus Installationbus
2Specifications are subject to change without notice (04.03.2009)
Dupline®is a registered trademark. A product of the CARLO GAVAZZI Group
GAP 1605
Mode of Opera ion
The GAP 1605 is a portable
programming unit used for
reading or programming
channel code(s) in the series
of Dupline
®
products.
The external switch turns
the power on/off.
When the battery is installed
and the power is on, the
GAP 1605 is ready for use.
Connect the cable between
the programming unit and a
Dupline
®
module type G..
5 keys provide the means of
operating the GAP 1605:
two keys are used for read-
ing and programming, two
keys for changing Groups
and Channels and one key
for selecting the desired
Input/Output.
The current coding is dis-
played by 4 x LEDs. The
top row of LEDs displays the
selected input or output.
The two middle rows display
the current channel group,
while the bottom row dis-
plays the current channel
code.
« In/Out - Key
This key is used to scroll
through the I/O's of a mod-
ule. If a new module is con-
nected or if consecutive
channel codes are allocated
to the I/O's, pressing the
«In/Out » key has no effect
since all Dupline
®
modules
are preprogrammed to their
physical number of inputs/
outputs. This key is also
used to switch between
consecutive and individual
coding of the I/O's. To
change the mode, keep
« In/Out pressed for more
than 2 seconds.
« Group - Key
Used to select the Group
address within the range A
to P. The Group LED will
shift one position right for
each key activation.
« Channel - Key
Used to select the chan-
nel(s) within the group. The
Channel LED will shift right
one, two or four positions,
depending on the number of
inputs/outputs. If consecu-
tive channels are selected,
then pressing the « Channel
key will have no effect.
« Read / On - Key
Used to turn on the GAP
1605 and to read the chan-
nel codes of the connected
module. When the reading is
completed, the display will
show the channel code of
the module: either 1, 2, 4 or
inputs/outputs.
2, 4 or In/Out LED's being
ON indicates that consecu-
tive channel codes are allo-
cated to the I/O's, e.g. input
1 coded to P1, input 2 to P2
... input to P .
If only one In/Out LED is
ON, then the I/O's are cod-
ed individually, e.g. input 1
to C5, input 2 to D4 etc. The
code for each I/O is indicat-
ed by a group LED and a
channel LED.
If the GAP 1605 is not con-
nected to a Dupline
®
system,
it will turn off within two se-
conds.
« Prog - Key
When the displayed I/O-
coding corresponds to the
desired channel configura-
tion, the codes will be
downloaded to the Dupline
®
module when pressing the
« Prog key.
After programming is exe-
cuted, a verification takes
place. If this verification
fails, all activated LEDs in
the display will flash two
times, and the programming
unit will switch off.
If such behaviour occurs re-
peatedly on the same mod-
ule, the module may be
faulty. If several modules fail
to download, the GAP 1605
may be faulty.
Individual In/Out channel
programming
The GAP 1605 features an
additional mode of single-
channel editing. Pressing
« In/Out for more than 2
seconds will change the
operating mode to single-
point programming. The
« In/Out key is now used
to select one of the eight
possible inputs/output, thus
making individual channel
coding possible. The In/Out-
LEDs assign the display
channel code to the corre-
sponding physical input/out-
put of the module.
In singlemode the « Chan-
nel key also has the ability
to disable an In/Out-position.
« Channel must simply be
pressed past channel ,
whereby both the Channel
LED and the Group LED will
turn off. To reenable, just
press « Channel again.
It is possible to change all
eight Inputs/Outputs, even
though some Dupline mod-
ules are built for only 1, 2 or
4 Inputs/Outputs.
To exit single channel pro-
gramming, just keep the
« In/Out key pressed for 2
seconds.
Output status setting
On receivers it is possible to
configure the status of the
outputs during Dupline
®
fail-
ure. Normally, any output of
a receiver will go off during
Dupline failure. In some cas-
es the inverted function is
desirable (e.g. light applica-
tions - turn on light if the
Dupline
®
is down).
To change output status, the
GAP 1605 must be put into
configuration mode. This is
done as follows:
• Remove any connected
Dupline
®
system.
• Keep both « In/Out and
« Group pressed, while
pressing « Read/On .
The first In/Out LED now
turns on. Connect the Dupline®
system, and press « Read/
On . If output status is set,
then channel LED 1 will illu-
minate. Pressing « Channel
will toggle the output status
On/Off.
Press « Prog to store.
If « Read/On is pressed
when no Dupline
®
system is
connected, the LEDs will
flash to indicated a false
condition. Only a successful
reading will reset this condi-
tion.

Du line
®
Fieldbus Installationbus
Specifications are subject to change without notice (04.03.2009) 3
Dupline®is a registered trademark. A product of the CARLO GAVAZZI Group
GAP 1605
Mode of Opera ion (con .)
Other features
To code a Dupline
®
module
off-line, neither Dupline nor
power to supply the module
is required. Simply connect
the module to the program-
mer and start coding.
If On-line coding (module
connected to an operating
Dupline
®
system) is per-
formed, the module auto-
matically disconnects ifself
from the Dupline
®
and
returns to normal operation
after the programmer cable
is disconnected.
The GAP 1605 automatically
turns off when no key has
been pressed within the last
30 seconds.
If the connection cable is re-
moved from the Dupline
®
module, the GAP 1605 will
switch off within 2 seconds.
Low battery indication
When battery is low, the
In/Out row of LEDs will roll
centerwards in an eye-
catching manner.
Warning
When using the GAP 1605
you must connect the cable
to the GAP 1605 before
connecting the cable to any
Dupline
®
module that is to
be coded. Even so, the
cable must first be removed
from the Dupline
®
module
before disconnecting it from
the GAP 1605.
Without observing these pre-
cautions you may destroy
the ASIC inside the Dupline
®
module through static dis-
charges.
Caution
To ensure long battery life,
always remember to turn the
“switch off” on the GAP
1605.
Additional information
Scope of supply:
1 x programming unit
GAP 1605
1 x cable
GAP CAB
1 x user manual
MAN GAP ENG
Not supplied:
1 x 9 V battery type 6LR61

Below is a list of articles with direct links to our shop Electric Automation Network where you
can see:
• Quote per purchase volume in real time.
• Online documentation and datasheets of all products.
• Estimated delivery time enquiry in real time.
• Logistics systems for the shipment of materials almost anywhere in the world.
• Purchasing management, order record and tracking of shipments.
To access the product, click on the green button.
Product Code Reference Product link
Selected parameters MODULE TYPE Accessory HOUSING
Handheld POWER SUPPLY Battery I/O TYPE None NUMBER
OF I/O 0 Others MODULE TYPE Coding Unit HOUSING
Handheld I/O TYPE None POWER SUPPLY 9V Alkaline MAIN
CHARACTERISTICS Address coding unit for Dupline
GAP1605
Buy on EAN
Table of contents
Popular Transceiver manuals by other brands

Toshiba
Toshiba ZS-7222A Service data

Vertex Standard
Vertex Standard Spirit VXA-700 operating manual

Kenwood
Kenwood TS-430S instruction manual

Connex
Connex CX-4400 HP Service manual

Technisonic Industries Limited
Technisonic Industries Limited TiL-91-DE/S Installation and operating instructions

LNR
LNR Mountain Topper manual

signal one
signal one millspec 1030c Operating and technical manual

uAvionix
uAvionix SkyEcho Installation and Pilot's Guide

XCOM
XCOM 760 Installation and user manual

Yaesu
Yaesu FT-950 Update

GRASS VALLEY
GRASS VALLEY IQMIX25 Series user manual

Delta Electronics
Delta Electronics LCP-155B4MSRx Series Specification sheet