Duraflo 60PRO130 User manual

DURAFLO® SECTION 077200 ROOF VENTS
www.duraflo.com
WE KNOW VENTILATION
by
Eective Date: Nov 1, 2015

- 2 -
Extreme weather conditions across the
country has increased the demand for a
weather resistant vent. Durao hasdeveloped
the WeatherPRO® Series line of roof vents,
which are available now through your local
distributor or retail store.
With the WeatherPRO® Series, you no longer
need to worry about extreme weather. Designed
to allow for high volumes of airow, while
providing excellent defence against weather
inltration, the patented WeatherPRO® internal
baes deect water and snow allowing for
harmless draining out the drainage openings.The
WeatherPRO® series also incorporates a patent
pending moisture control system which directs
precipitation away from the vent openings.
Combining manufacturing quality, with
Durao WeatherPRO® technology, and a patent
pending moisture control system, will ensure
the WeatherPRO® Series is the rst choice when
weather inltration is an issue.

- 3 -
Injection molded from pure, high grade polypropylene with premium UV inhibitor additives
that blocks harmful UV Rays.
•Over 15 years of accelerated
weathering testing
•Customized UV inhibitor package in all
molded products
•All colours contain UV inhibitors
•CSA evaluated
Evaluated and passed based on
the following criteria:
•ASTM G 155 Accelerated Weathering
•ASTM D 638 Tensile Strength Dierence
•ASTM D 2843 Smoke Density Rating
•ASTM D 635 Rate of Burning
Material & UV Protection
Material - Cold Impact Tested
WeatherPRO® Upward Venting
The solid sidewalls and upward venting design behind the WeatherPRO® vents have been engineered to increase
weather protection while improving ventilation in high wind areas. The solid sidewalls work in part with the interior
baes, providing the rst line of defense against driving rain and snow. The solid sidewalls also act to push wind up
and over the cap of the vent, as opposed to under, like a traditional roof vent. This airow over the cap of the vent
creates negative pressure to draw air from the attic.
The WeatherPRO® line of vents are manufactured from all virgin polypropylene allowing them to withstand the most
extreme climates. The material used in manufacturing the WeatherPRO® Series is cold impact tested at -40 degrees.
The material remains functional, exible and resilient to damage even when installed with a nail gun.
UV Protected
Polypropylene
0.06”
(1.52 mm)
0.009”
(0.229 mm)
UV Rays are
blocked
after only
.009”
(0.229 mm)
Interior
bae
shield
Interior bae shield Interior bae shield Interior bae shields

- 4 -
DESCRIPTION PART # SIZE -
IMPERIAL
SIZE -
METRIC
Black 60PRO150BL
21-1/8”
x 21-1/8”
x 22”
536 mm
x 536 mm
x 559 mm
Brown 60PRO150BR
Grey 60PRO150G
Weatherwood 60PRO150WW
DESCRIPTION PART # SIZE -
IMPERIAL
SIZE -
METRIC
Black 60PRO140BL
21-1/8”
x 21-1/8”
x 19-1/2”
536 mm
x 536 mm
x 495 mm
Brown 60PRO140BR
Grey 60PRO140G
Weatherwood 60PRO140WW
DESCRIPTION PART # SIZE -
IMPERIAL
SIZE -
METRIC
Black 60PRO130BL
21-1/8”
x 21-1/8”
x 17”
536 mm
x 536 mm
x 432 mm
Brown 60PRO130BR
Grey 60PRO130G
Weatherwood 60PRO130WW
STATIC VENTS - PROVentilator
, 1, 2 & 3 Tier Models
3 Tier 60PRO150 Model: 130 sq-in / 839 sq-cm
2 Tier 60PRO140 Model: 95 sq-in / 613 sq-cm
1 Tier 60PRO130 Model: 48 sq-in / 310 sq-cm
• Engineeredtoresistdenting,peeling,extremeheatandcoldimpactto-40
Black, Brown, Weatherwood, Grey
WeatherPRO’s patented internal baes deect water and snow, allowing for harmless draining out the drainage
openings. Designed to allow high airow while providing excellent defense against weather inltration.
Description:
Net Free Venting Area
Approved Certications
Durability
Colors Available
Weather Protection
Models: WeatherPRO® PROVentilators:
3 Tier #60PRO150 2 Tier #60PRO140 1 Tier #60PRO130
Multiple pivot stop
points for quick
leveling
Molded in
screw guides
External Drip tray
allows moisture to
drain harmlessly away
from vent openings
Easily adjust to roof
pitch with front
and back locking
tabs
Large top
cap improves
appearance of the
roof line
Unique bae
system wards o
wind driven snow
and rain
• CSAcertied-PlasticTypeBroofvents,forinstallationonslopingsurfaces
• MiamiDadeHighVelocityHurricaneZonecertied
Model
Heights: 21-1/8”
20”
19-7/8”
21-1/8”
22” 19-1/2” 17”
3 Tier 2 Tier 1 Tier
3 Tier, 2 Tier & 1 Tier
3, 2 or 1 Tier
models
• One3TierModelwillventilate1000-1200sq.ft.ofatticspace(approx)
• One2TierModelwillventilate400-500sq.ft.ofatticspace(approx)
• One1TierModelwillventilate200-300sq.ft.ofatticspace(approx)
• Patentedinternalweatherbaes
• ThechimneystyledesignallowsthePROVentilatortoharnesswindenergyandcreatepressurevariances
that powerfully draw air out from within the attic space.
• Roofpitchrange3/12–12/12
• Injectionmoldedfrompure,highgradepolypropylenewithpremiumUVinhibitors
• Lightweight,no-assemblydesignmakesforeasyhandling.Settingthepitchisquickandsimplewithcentralizedpivot
points, built-in adjustment tabs and pitch stops.
Common
Dimensions:

- 5 -
Net Free Venting Area
TURBINE VENTS - PROTURBO
DESCRIPTION PART # SIZE
IMPERIAL METRIC
Black 60PRO117BL 17-1/2”x 20” x 16-1/4” 445mm x 508mm x 413mm
Brown 60PRO117BR 17-1/2” x 20” x 16-1/4” 445mm x 508mm x 413mm
Weatherwood 60PRO117WW 17-1/2” x 20” x 16-1/4” 445mm x 508mm x 413mm
Grey 60PRO117G 17-1/2” x 20” x 16-1/4” 445mm x 508mm x 413mm
• Nointernalorexternalmovingparts–requiresnomaintenance
• OneTurbowillventilate1000sqft(93sq.meters)ofatticspace(approx)–regardlessofwindspeed
• Roofpitchrangefrom3/12to12/12
• Largeashingallowsforeasyinstallation
• Injectionmoldedfrompure,highgradepolypropylenewithpremiumUVinhibitors
• Availableasafullunit(includingbase)orasreplacementtoponly
• Lightweight,no-assemblydesignmakesforeasyhandling.Settingthepitchisquickandsimplewithcentralizedpivot
points, built-in adjustment tabs and pitch stops.
117 sq-in / 755 sq-cm
• CSAcertied-PlasticTypeBroofvents,forinstallationonslopingsurfaces
• MiamiDadeHighVelocityHurricaneZonecertied
• Engineeredtoresistdenting,peeling,extremeheatandcoldimpactto-40
Black, Brown, Weatherwood, Grey
WeatherPRO’s patented internal baes deect water and snow, allowing for harmless draining out the drainage
openings. Designed to allow high airow while providing excellent defense against weather inltration.
Net Free Venting Area
Approved Certications
Durability
Colors Available
Weather Protection
Model: WeatherPRO® PROTurbo # 60PRO117
Pivoting top with
locking pitch guide
tabs–3/12to12/12
Unique bae
system wards
o wind driven
snow and rain
Cold impact
resistant to -40
Crush, Dent &
UV resistant
polypropylene
117 Sq. In.
Net Free
Venting Area
17-1/2” 17-1/2”
16-1/4”
3-3/4”
20”
21”
21”
A
C
D
A
B
3/12 - 12/12
3/12 - 12/12
(580mm)
(95mm)
(445mm)(445mm)
(413mm)
(533mm)
Description:
Dimensions:

- 6 -
24”
(610 mm)
19”
(483 mm)
18”
(457 mm)
12”
(309 mm)
3-1/2”
(89 mm)
DESCRIPTION PART # SIZE
IMPERIAL METRIC
Black 60PRO50SLBL 18”x 24” x 3-1/2” 457 mm x 610 mm x 89 mm
Brown 60PRO50SLBR 18”x 24”x 3-1/2” 457 mm x 610 mm x 89 mm
Grey 60PRO50SLG 18”x 24”x 3-1/2” 457 mm x 610 mm x 89 mm
Weatherwood 60PRO50SLWW 18” x 24”x 3-1/2” 457 mm x 610 mm x 89 mm
2.
Drainage
openings
4.
Outer vertical
walls
5.
Protected vent
opening
Moisture drip
channels
1.
Air exits
over the
vent not under
3.
Diverts run-o
around cap
STATIC VENTS - PROSlantBack
• Patentedinternalweatherbaes
• FivePROSlantBack’swillventilate1000sq.ft.(93sq.meters)ofatticspace(approx)
• Roofpitchrange3/12–14/12
• Injectionmoldedfrompure,highgradepolypropylenewithpremiumUVinhibitors
• Topventingdesignuseschimneyeecttochannelmoistairawayfromroofeliminatingshinglestaining
• Ventcapdesignwithbuiltinweepingholeseliminatesbirdnestingandwaterpooling
• Uniquedesignallowsittobeusedasanintakewheresotventilationislimitedornotavailable
50 sq-in / 322 sq-cm
•CSAcertied–PlasticTypeBroofvents,forinstallationonslopingsurfaces
• MiamiDadeHighVelocityHurricaneZonecertiedNOA#11-0930.08
• Engineeredtoresistdenting,peeling,extremeheatandcoldimpactto-40
Black, Brown, Weatherwood, Grey
WeatherPRO’s patented internal baes deect water and snow, allowing for harmless draining out the drainage
openings. Designed to allow high airow while providing excellent defense against weather inltration.
Description:
Net Free Venting Area
Approved Certications
Durability
Colors Available
Weather Protection
Dimensions:
Model: WeatherPRO® SlantBack, # 60PRO50SL

- 7 -
Net Free Venting Area 2.
Drainage openings
1.
Air exits over the
vent not under
18-1/2”
(470 mm)
18-1/2”
(470 mm)
4-1/2”
(114 mm)
DESCRIPTION PART # SIZE
IMPERIAL METRIC
Black 60PRO50BL
18-1/2” x 18-1/2” x 4-1/2” 470 mm x 470 mm x 114 mm
Brown 60PRO50BR
18-1/2” x 18-1/2” x 4-1/2” 470 mm x 470 mm x 114 mm
Grey 60PRO50G
18-1/2” x 18-1/2” x 4-1/2” 470 mm x 470 mm x 114 mm
White 60PRO50W
18-1/2” x 18-1/2” x 4-1/2” 470 mm x 470 mm x 114 mm
Weatherwood 60PRO50WW
18-1/2” x 18-1/2” x 4-1/2” 470 mm x 470 mm x 114 mm
STATIC VENTS - PRO50
• Patentedinternalweatherbaes
• FiveWeatherPROPRO50’swillventilate1000sq.ft.(93sq.meters)ofatticspace(approx)
• Roofpitchrange3/12–14/12
• Injectionmoldedfrompure,highgradepolypropylenewithpremiumUVinhibitors
• Topventingdesignuseschimneyeecttochannelmoistairawayfromroofeliminatingshinglestaining
• Ventcapdesignwithbuiltinweepingholeseliminatesbirdnestingandwaterpooling
50 sq-in / 322 sq-cm
• CSAcertied–PlasticTypeBroofvents,forinstallationonslopingsurfaces
• MiamiDadeHighVelocityHurricaneZonecertied:NOA04.0401.01
• Engineeredtoresistdenting,peeling,extremeheatandcoldimpactto-40
Black, Brown, Weatherwood, Gray, White
WeatherPRO’s patented internal baes deect water and snow, allowing for harmless draining out the drainage
openings. Designed to allow high airow while providing excellent defense against weather inltration.
Description:
Net Free Venting Area
Approved Certications
Durability
Colors Available
Weather Protection
Dimensions:
Model: WeatherPRO® PRO50, model # 60PRO50
3.
Diverts run-o
around cap

- 8 -
STATIC VENTS - PRO75
5-1/2”
(140mm)
217/8”
(555.63mm)
15.-7/8”
(403.23mm)
21-7/8”
(556mm)
21-7/8”
(555.63mm
)
21-7/8”
(556mm)
15-7/8”
(403mm)
15-7/8”
(403.23mm)
15-7/8”
(403mm)
DESCRIPTION PART # SIZE
IMPERIAL METRIC
Black 60PRO75BL 21-7/8” x 21-7/8” x 5-1/2” 556 mm x 556 mm x 140 mm
Brown 60PRO75BR 21-7/8” x 21-7/8” x 5-1/2” 556 mm x 556 mm x 140 mm
Grey 60PRO75G 21-7/8”x 21-7/8” x 5-1/2” 556 mm x 556 mm x 140 mm
White 60PRO75W 21-7/8”x 21-7/8” x 5-1/2” 556 mm x 556 mm x 140 mm
Weatherwood 60PRO75WW 21-7/8” x 21-7/8” x 5-1/2” 556 mm x 556 mm x 140 mm
• Patentedinternalweatherbaes
• FourPRO75’swillventilate1000sqft(93sq.meters)ofatticspace(approx)
• Roofpitchrange3/12–12/12
• Injectionmoldedfrompure,highgradepolypropylenewithpremiumUVinhibitors
• Topventingdesignuseschimneyeecttochannelmoistairawayfromroofeliminatingshinglestaining
• Ventcapdesignwithbuiltinweepingholeseliminatesbirdnestingandwaterpooling
75 sq-in / 483 sq-cm
• CSAcertied-PlasticTypeBroofvents,forinstallationonslopingsurfaces
• Engineeredtoresistdenting,peeling,extremeheatandcoldimpactto-40
Black, Brown, Weatherwood, Grey, White
WeatherPRO’s patented internal baes deect water and snow, allowing for harmless draining out the drainage
openings. Designed to allow high airow while providing excellent defense against weather inltration.
Description:
Net Free Venting Area
Approved Certications
Durability
Colors Available
Weather Protection
Dimensions:
2.
Drainage
openings
5.
Protected vent
opening
Moisture drip
channels
1.
Air exits
over the
vent not under
3.
Diverts run-o
around cap
4.
Outer vertical
walls
Model: WeatherPRO® PRO75, model # 60PRO75

- 9 -
AirFoil
Designed Edge
(1219mm)
4 Ft.
4 Ft.
DESCRIPTION PART # A
IMPERIAL METRIC
Metric - Black 6072METBL 12-7/8” 327mm
Metric - Brown 6072METBR 12-7/8” 327mm
Metric - Weatherwood 6072METWW 12-7/8” 327mm
Imperial - Black 6073BL 11-5/8” 295mm
Imperial - Brown 6073BR 11-5/8” 295mm
Imperial - Weatherwood 6073WW 11-5/8” 295mm
CONTINUOUS RIDGE VENTS - WeatherPRO® Ridge
• EngineeredwithAirFoilTechnology–basedontheBernoulliprincipletomaximizeairlift
• FourpiecesofWeatherPRO®PRORidgeventwillventilate1000sq.ft.(93sq.meters)ofatticspace(approx)
• Patentedinternalweatherbaesystem
• Roofpitchrange3/12–12/12
• 4footsections,12piecespercarton
• Latchconnectorsoneachend,built-inendcapsevery3in/7.6cm
• Injectionmoldedfrompure,highgradepolypropylenewithpremiumUVinhibitors
• AvailableforusewitheitherMetricorImperialsizeshingles
18.3sq-inperlinearfoot(387sq-cmperlinearmeter)
• CSAcertied-PlasticTypeCridgevent,forinstallationonroofridge
• Engineeredtoresistdenting,peeling,extremeheatandcoldimpactto-40
Black, Brown, Weatherwood
WeatherPRO’s patented internal baes deect water and snow, allowing for harmless draining out the drainage
openings. Designed to allow high airow while providing excellent defense against weather inltration.
Description:
Approved Certications
Durability
Colors Available
Weather Protection
Dimensions:
Models: WeatherPROPRORidge,•Metric-6072MET•Imperial-6073
Net Free Venting Area
Net Free Venting Area

- 10 -
Ventilation Calculator
Ventilation requirements for your home
The included ventilation calculator is only a guide, please consult your local building code for specic ventilation requirements.
A home requires an equal amount of intake
(soffit) & exhaust (roof) ventilation.
Note: Roof pitches under 4/12 require double the amount of ventilation.
Use this chart to determine how many vents your attic requires.
Ventilation
Calculator
DESCRIPTION
NET FREE AREA
OF VENT
NUMBER OF VENTS NEEDED FOR
1000 sq. ft.
(93 sq. meters)
1500 sq. ft.
(139 sq. meters)
2000 sq. ft.
(186 sq. meters)
2500 sq. ft.
(232 sq. meters)
IMPERIAL METRIC OF ATTIC SPACE
3 TIER
WEATHERPRO
PROVENTILATOR
130
Sq. In.
839
Sq. cm 1 2 3 4
2 TIER
WEATHERPRO
PROVENTILATOR
95
Sq. In.
613
Sq. cm 2 3 4 5
1 TIER
WEATHERPRO
PROVENTILATOR
48
Sq. In.
310
Sq. cm 4 6 8 10
WEATHERPRO
TURBO
117
Sq. In.
755
Sq. cm 1 2 3 4
WEATHERPRO
SLANT BACK
50
Sq. In.
322
Sq. cm 5 8 10 12
WEATHERPRO
60PRO50
50
Sq. In.
322
Sq. cm 5 8 10 12
WEATHERPRO
60PRO75
75
Sq. In.
484
Sq. cm 4 5 7 8
WEATHERPRO
RIDGE VENTS
72
Sq. In.
465
Sq. cm 4 5 7 10

- 11 -
The included ventilation calculator is only a guide, please consult your local building code for specic ventilation requirements.
DESCRIPTION
NET FREE AREA
OF VENT
NUMBER OF VENTS NEEDED FOR
1000 sq. ft.
(93 sq. meters)
1500 sq. ft.
(139 sq. meters)
2000 sq. ft.
(186 sq. meters)
2500 sq. ft.
(232 sq. meters)
IMPERIAL METRIC OF ATTIC SPACE
3 TIER
WEATHERPRO
PROVENTILATOR
130
Sq. In.
839
Sq. cm 1 2 3 4
2 TIER
WEATHERPRO
PROVENTILATOR
95
Sq. In.
613
Sq. cm 2 3 4 5
1 TIER
WEATHERPRO
PROVENTILATOR
48
Sq. In.
310
Sq. cm 4 6 8 10
WEATHERPRO
TURBO
117
Sq. In.
755
Sq. cm 1 2 3 4
WEATHERPRO
SLANT BACK
50
Sq. In.
322
Sq. cm 5 8 10 12
WEATHERPRO
60PRO50
50
Sq. In.
322
Sq. cm 5 8 10 12
WEATHERPRO
60PRO75
75
Sq. In.
484
Sq. cm 4 5 7 8
WEATHERPRO
RIDGE VENTS
72
Sq. In.
465
Sq. cm 4 5 7 10
INSTALLATION - PROVentilator, 1, 2 & 3 Tier Models
4. Using a 1/2“ (1.3 cm) bead, apply a generous amount of
construction sealant to the base of the vent.
4.
Note: Use non-petroleum based sealants only. The use
of petroleum based sealants may void any
manufactures product warranty.
5.
5. Position the roof vent over the cut opening in the
roof. Center the vent by aligning edges of the vent
throat with the chalk lines previously marked. Using
the molded nail indicators, nail the top half of the vent
securely into place.
8.
8. Using the 4 screws supplied, secure vent into position as shown.
7.
7. Using the pitch tabs lower the top of the unit back to desired
pitch. Ensure the top of the unit is level.
Level Top
Pitch Tabs
24”
(61 cm)
12” x 12”
(30.5 cm x 30.5 cm)
1. Apply underlayment on the sheathing and in the
center of the rafters cut a 12”(30.5 cm) square hole.
The edge of the hole should be at least 12”(30.5 cm)
and no more than 24”(61 cm) from the roof peak.
2. Using a 1/2”(1.3 cm) bead, apply a generous amount
of construction sealant to the underlayment infront of
hole before applying next shingle course.
2.
Underlayment
Shingles
3. Install next shingle course over sealant bead
and mark extended chaulk lines to help position
vent over opening in next step.
3.
6. 6. Gently lift the pitch calculating tabs (Fig A.),
rotating the top of the unit up to make room
for nailing the bottom half of the ange (Note:
Ensure the vent throat overlaps (Fig B.). Using
the molded nail indicators, nail the remainder
of the vent securely into place.
Fig. B. Fig. A.
Note: For added
protection against
weather inltration
seal any exposed
nail heads.
For New Construction
Note: PROVentilator placement
and the balancing of intake and
exhaust venting are extremely
important in achieving ideal
ventilator performance. For more
information on ventilation systems
see Durao.com or consult the local
building code.

- 12 -
4.
4. Using a 1/2 inch bead, apply a generous amount of
construction sealant to the base of the vent.
Note: Use non-petroleum based sealants only. The use
of petroleum based sealants may void any
manufactures product warranty.
5.
5. Position the roof vent over the cut opening in the
roof. Center the vent by aligning edges of the vent
throat with the chalk lines previously marked. Using
the molded nail indicators, nail the top half of the vent
securely into place.
8.
8. Using the molded in screw guide in front of vent, secure vent into
position as shown with 1 screw supplied.
7.
7. Using the pitch tabs pivot the top of the unit to desired pitch.
Ensure the top of the unit is level.
Level Top
24”
12” x 12”
1. Apply underlayment on the sheathing and In the
center of the rafters cut a 12”round hole. The edge
of the hole should be at least 12”and no more than
24”from the roof peak.
2.
Underlayment
Shingles
3. Install next shingle course over sealant bead
and mark extended chaulk lines to help position
vent over opening in next step.
3.
6. 6. Gently lift the pitch calculating tabs (Fig A.),
pivoting the top of the unit up to and nail the
bottom half of the ange.
Note: For added
protection against
weather inltration
seal any exposed
nail heads.
Fig. A.
Pitch Tabs
Pitch Tabs
2. Using a 1/2 inch bead, apply a generous amount
of construction sealant to the underlayment infront
of hole before applying next shingle course.
INSTALLATION - PROTurbo
For New Construction
Installation of Durao WeatherPRO®
PROTurbo should comply with all
local standards and regulations.
Before beginning a job, determine
how much ventilation is required in
bothsotandroofventsandwhat
sizes of vent would best suit the job.
If required, refer to Durao Ventilation
Calculator for guidance.

- 13 -
INSTALLATION - PRO SlantBack
For New Construction or Re-Roong
1. Determine the location of vents:
Evenly space the roof vents along the width of
the roof, marking the location of all roof vents
before cutting holes. Centre the holes between
therafterswithintwofeet(24”)(61cm)from
the peak of the roof.
Cut and prepare the opening:
Cut the holes in the sheathing before applying
shingles,cuta6-1/2”x8-1/2”(16.5cmx21.6cm)
opening. Shingle up until the rst full course of
shingles covers the bottom of the hole. Cut the
excess shingles away from the hole.
2. Position the vent and nail the vent
in place:
Durao Roof Vents have a top arrow indicator.
Make sure the throat of the vent is in the proper
position centered over the opening. Using the
pre-marked nail holes, nail the vent securely
into place.
3. Complete the shingle installation:
Continue installing shingles, overlapping
the ange of the vent. Cut the shingles around
the top of the vent to match its shape.
Installation of Durao WeatherPRO® SlantBack Vent should comply with all local standards and regulations.
Beforebeginningajob,determinehowmuchventilationisrequiredinbothsotandroofventsandwhatsizes
of vent would best suit the job. If required, refer to Durao Ventilation Calculator for guidance.
Caution: DO NOT USE roong cement /
roong tar to seal the vent to the roof. The
wide ange and molded-in water guards
will force the water down the roof over
the shingles. The polypropylene ange
is large enough and exible enough to
eectively self seal against the roof without
the aid of roong tars. Roong tars are
potentially damaging to the roof vent and
the asphalt shingles. Use of roong tar
will void any warranty on the Durao Roof
Vents. Optional: Seal all nail heads with an
approved sealant, such as silicone. Make
sure the sealant is a non-petroleum product
(usuallyavailableinaplastictube).
6-1/2”
(16.5 cm)
8-1/2”
(21.6 cm)
24”
(61 cm)
Rough Cut Opening

- 14 -
INSTALLATION - PRO50 & PRO75
For New Construction or Re-Roong
1. Determine the location of vents:
Evenly space the roof vents along the width of
the roof, marking the location of all roof vents
before cutting holes. Centre the holes between
therafterswithintwofeet(24”)(61cm)from
the peak of the roof.
Cut and prepare the opening:
Cut the holes in the sheathing before applying
shingles,forPRO50cuta7-1/4”x7-1/4”
(18.4cmx18.4cm)opening,forthePRO75cuta
9-1/2”x9-1/2”(24cmx24cm)opening.Shingle
up until the rst full course of shingles covers the
bottom of the hole. Cut the excess shingles away
from the hole.
2. Position the vent and nail the vent
in place:
Durao Roof Vents have a top arrow indicator.
Make sure the throat of the vent is in the proper
position centered over the opening. Using the
pre-marked nail holes, nail the vent securely
into place.
3. Complete the shingle installation:
Continue installing shingles, overlapping
the ange of the vent. Cut the shingles around
the top of the vent to match its shape.
Installation of Durao WeatherPRO® PRO50 or PRO75 Roof Vent should comply with all local standards and
regulations.Beforebeginningajob,determinehowmuchventilationisrequiredinbothsotandroofvents
and what sizes of vent would best suit the job. If required, refer to Durao Ventilation Calculator for guidance.
Caution: DO NOT USE roong cement /
roong tar to seal the vent to the roof. The
wide ange and molded-in water guards
will force the water down the roof over
the shingles. The polypropylene ange
is large enough and exible enough to
eectively self seal against the roof without
the aid of roong tars. Roong tars are
potentially damaging to the roof vent and
the asphalt shingles. Use of roong tar
will void any warranty on the Durao Roof
Vents. Optional: Seal all nail heads with an
approved sealant, such as silicone. Make
sure the sealant is a non-petroleum product
(usuallyavailableinaplastictube).
PRO75
Rough Cut Opening
7-1/4”
(18.4 cm)
7-1/4”
(18.4 cm)
9-1/2”
(24 cm)
9-1/2”
(24 cm)
24”
(61 cm)
PRO50
Rough Cut Opening

- 15 -
INSTALLATION GUIDE
Step 1.
Cut a slot in sheathing along the ridge 2”(5 cm) wide 1” (2.5 cm)
on each side of peak).
If ridge beam is present, cut a slot 1”(2.5 cm) wide on each side of the
beam. A closed area of sheathing 12”(30.5 cm) in length should be at
both ends of ridge. The 12” (30.5cm) area should be coverd to prevent
inltration.
Step 2.
For step 2 it is recommended a chalk line be used to ensure the ridge
vent is installed straight along the roof peak.
Place the rst piece of vent with female end 1/2” (1.3 cm) from the
gable end. On one side of the peak fasten the rst piece using nails at
each end and in middle sections. Fold the vent over the peak and
fasten the second side using the same nail pattern. (2” (5 cm) nails are
minimum length). Continue installing additional pieces along
ridge connecting the female end over the male end.
Step 3.
When reaching the ridge end, the last vent section may need to
be cut to length. There are molded-in end caps every 3” (7.6 cm) on the
underside of the ridge vent. Measure and cut amount needed to
install to within 1/2” (1.3 cm) of ridge end.
After fastening the ridge vent to the roof peak install ridge caps
using a min 2” (5 cm) nail. The ridge caps should be centered on the
vent and sit between the outer raised bae walls.
Canplas Industries Ltd.
P.O Box 1800, 500 Veterans Drive
Barrie, Ontario, Canada L4M 4V3
Tel. (705) 726-3361
Toll Free 1-800-461-5300
Fax: (705) 726-2186
Canplas LLC
11402 East 53rd Ave.
Suite 200, Denver, CO, U.S.A. 80239
Tel: (303) 373-1923
Toll Free: 1-800-461-5307
Fax: (303) 373-1928
1
2B
2C
3
2A
Caution:
seal the vent to the roof.
with a non-petroleum based sealant product.
12” (30.5 cm)
INSTALLATION - WeatherPRO® RIDGE VENT
Installation of Durao WeatherPRO® PRORidge Vent should
comply with all local standards and regulations. Before
beginning a job, determine how much ventilation is required
inbothsotandroofventsandwhatsizesofventwouldbest
suit the job. If required, refer to Durao Ventilation Calculator
for guidance.

- 16 -
Specications
SECTION 077200 - ROOF VENTS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Roof vents of the following types:
1. Continuousridgevents.(WeatherPRORidge)
2. Turbinevents.(WeatherPROTurboVent).
3. Staticvents.(WeatherPRO75)(WeatherPro50)
(WeatherPROSlantBack)(WeatherPRO
PROVentilator)
1.2 RELATED SECTIONS
A. Section 07310 - Asphalt Shingles: Rough-in and
installation requirements.
1.3 SUBMITTALS
A. Submit under provisions of Section 01300.
B. Product Data: Manufacturer’s data sheets on each
product to be used, including:
1. Preparation instructions and recommendations.
2. Storage and handling requirements and
recommendations.
3. Installation methods.
1.4 QUALITY ASSURANCE
A. Manufacturer Qualications: Minimum 5 years
experience manufacturing similar products.
B. Installer Qualications: Minimum 2 years experience
installing similar products.
1.5 PRE-INSTALLATION MEETINGS
A. Convene minimum two weeks prior to starting
Work of this section.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Deliver and store products in manufacturer’s
unopened packaging bearing the brand name
and manufacturer’s identication until ready
for installation.
B. Handling:Handlematerialstoavoiddamage.
1.7 PROJECT CONDITIONS
A. Maintainenvironmentalconditions(temperature,
humidity,andventilation)withinlimits
recommended by manufacturer for optimum
results. Do not install products under
environmental conditions outside manufacturer’s
recommended limits.
1.8 SEQUENCING
A. Ensure that products of this section are supplied to
aected trades in time to prevent interruption of
construction progress.
1.9 WARRANTY
A. Warranty: Provide manufacturer’s standard limited
warranty, and as follows:
1. WeatherPRO Ridge: 35 year limited warranty
2. WeatherPRO Turbo Vent: 35 year limited
warranty
3. WeatherPRO 75: 35 year limited warranty
4. WeatherPRO 50: 35 year limited warranty
5. WeatherPRO Slantback: 35 year limited warranty
6. WeatherPRO PROventilator: 35 year limited
warranty
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer:
Canplas Industries Ltd.; 500 Veterans Dr.
P.O. Box 1800, Barrie, ON, Canada
L4M4V3.ASD.TollFreeTel:(800)461-1771.
Tel:(705)726-3361.Fax:(705)726-2186.
Web: http://www.canplas.com
B. Substitutions: Not permitted.
C. Requests for substitutions will be considered in
accordance with provisions of Section 01600.
2.2 ROOF VENTS
A. Roof ventilation shall be from a single source
of Durao Roong Ventilation products
manufactured by Canplas Industries Ltd.
2.3 CONTINUOUS ROOF VENTS
A. Product: WeatherPRO Ridge as manufactured by
Canplas Industries Ltd.
1. Design: Internal baes and drainage openings
easily deect and direct away extreme weather.
Airfoil designed edge allows smooth airow over
the ridge line maximizing eective ventilation
from the attic space. TriFold exibility for use on
full range of pitches. Code regulated insect grill.
NetFreeArea:18.3sq.in./lin.ft.(387sq.cm/lin.m).
2. MiamiDadeHighVelocityHurricaneZone
certied: NOA 05-0516.06.
SPEC NOTE: See www.arcat.com website for
MicrosoftWord(editable)document.
SPEC NOTE: Canplas LLC and Canplas Industries Ltd. are
members of the Aliaxis Group of companies, a global leader
of plastic solutions for uid transport in the eld of building
materials. The Aliaxis Group provides products for both
residential and commercial building markets, in new build and
renovation segments, as well as a wide range of solutions for
industrial and public utility applications.

- 17 -
Specications
3. CSA certied - Plastic Type C ridge vent, for installation
on roof ridge.
4. Construction: Injection molded from pure, high
grade polypropylene with premium UV inhibitor
additives. Engineered to resist denting, peeling,
extreme heat and cold impact to -40 degree F
(-40degreeC).
5. Model:Metric–Black(6072METBL).
6. Model:Metric–Brown(6072METBR).
7. Model:Metric–Weatherwood(6072METWW).
8. Model:Imperial–Black(6073BL).
9. Model:Imperial–Brown(6073BR).
10.Model:Imperial–Weatherwood(6073WW).
2.4 TURBINE VENTS
A. Product: WeatherPRO® Turbo Vent as manufactured
by Canplas Industries Ltd.
1. Design:Nointernalorexternalmovingparts–requires
no maintenance. Internal baes deect water and
snow, allowing for harmless drainage out the drainage
openings.
Allows high airow while providing excellent defense
against weather inltration. Two-piece base ts roof
pitchesfrom3/12to12/12.117sq.in.(755sq.cm)net
free area.
2. Construction: Injection molded from pure, high
grade polypropylene with premium UV inhibitor
additives. Engineered to resist denting, peeling,
extreme heat and cold impact to -40 degree F
(-40degreeC).
3. CSA certied - Plastic Type B roof vents, for installation
on sloping surfaces.
4. MiamiDadeHighVelocityHurricaneZonecertied
5. Model:Black(60PRO117BL)17-1/2inchesx20inches
x16-1/4inches(445mmx508mmx413mm).
6. Model:Brown(60PRO117BR)17-1/2inchesx20inches
x16-1/4inches(445mmx508mmx413mm).
7. Model:Weatherwood(60PRO117WW)17-1/2inchesx
20inchesx16-1/4inches(445mmx508mmx
413mm).
8. Model:Grey(60PRO117G)17-1/2inchesx
20inchesx16-1/4inches(445mmx508mmx
413mm).
2.4 STATIC VENTS
A. Product: WeatherPRO® 75 as manufactured by
Canplas Industries Ltd.
1. Design: Top venting design uses chimney eect to
channel moist air away from roof eliminating shingle
staining. Vent cap design with built in weeping holes
eliminates bird nesting and water pooling. Roof pitch
range 3/12 to 12/12. Net free venting area of
75sq.in.(483sq.cm).
2. Construction: Injection molded from pure, high grade
polypropylene with premium UV inhibitor additives.
Engineered to resist denting, peeling, extreme heat
andcoldimpactto-40degreeF(-40degreeC).
3. CSA certied - Plastic Type B roof vents, for installation
on sloping surfaces.
4. Model:Black(60PRO75BL)21.875inchesx21.875
inchesx5.5inches(556mmx556mmx140mm).
5. Model:Brown(60PRO75BR)21.875inchesx21.875
inchesx5.5inches(556mmx556mmx140mm).
6. Model:White(60PRO75W)21.875inchesx21.875
inchesx5.5inches(556mmx556mmx140mm).
7. Model:Grey(60PRO75G)21.875inchesx21.875inches
x5.5inches(556mmx556mmx140mm).
8. Model:Weatherwood(60PRO75WW)21.875inchesx
21.875inchesx5.5inches(556mmx556mmx
140mm).
B. Product: WeatherPRO® 50 as manufactured by
Canplas Industries Ltd.
1. Design: Top venting design uses chimney eect to
channel moist air away from roof eliminating shingle
staining. Vent cap design with built in weeping holes
eliminates bird nesting and water pooling. Roof pitch
range 3/12 to 14/12. Net free venting area of 50 sq. in.
(322sq.cm).
2. Construction: Injection molded from pure, high grade
polypropylene with premium UV inhibitor additives.
Engineered to resist denting, peeling, extreme heat
andcoldimpactto-40degreeF(-40degreeC).
3. CSAcertied–PlasticTypeBroofvents,forinstallation
on sloping surfaces.
4. MiamiDadeHighVelocityHurricaneZonecertied:
NOA 04.0401.01.
5. Model:Black(60PRO50BL)18-1/2inchesx18-1/2
inchesx4-1/2inches(470mmx470mmx114mm).
6. Model:Brown(60PRO50BR)18-1/2inchesx18-1/2
inchesx4-1/2inches(470mmx470mmx114mm).
7. Model:White(60PRO50W)18-1/2inchesx18-1/2
inchesx4-1/2inches(470mmx470mmx114mm).
8. Model:Grey(60PRO50G)18-1/2inchesx18-1/2inches
x4-1/2inches(470mmx470mmx114mm).
9. Model:Weatherwood(60PRO50WW)18-1/2inchesx
18-1/2inchesx4-1/2inches(470mmx470mmx
114mm).
C. Product: WeatherPRO® Slant Back as manufactured
by Canplas Industries Ltd.
1. Design: Top venting design uses chimney eect to
channel moist air away from roof eliminating shingle
staining. Vent cap design with built in weeping holes
eliminates bird nesting and water pooling. Roof pitch
range 3/12 to 14/12. Net free venting area of 50 sq. in.
(322sq.cm).
2. Construction: Injection molded from pure, high grade
polypropylene with premium UV inhibitor additives.
Engineered to resist denting, peeling, extreme heat

- 18 -
andcoldimpactto-40degreeF(-40degreeC).
3. CSAcertied–PlasticTypeBroofvents,forinstallation
on sloping surfaces.
4. MiamiDadeHighVelocityHurricaneZonecertied.
5. Model:Black(60PRO50SLBL)18inchesx24inches
x3-1/2inches(457mmx610mmx89mm).
6. Model:Brown(60PRO50SLBR)18inchesx24inches
x3-1/2inches(457mmx610mmx89mm).
7. Model:White(60PRO50SLW)18inchesx24inches
x3-1/2inches(457mmx610mmx89mm).
8. Model:Grey(60PRO50SLG)18inchesx24inches
x3-1/2inches(457mmx610mmx89mm).
9. Model:Weatherwood(60PRO50SLWW)18inchesx
24inchesx3-1/2inches(457mmx610mmx89mm).
D. Product: 3 TIER WeatherPRO PROVentilator as
manufactured by Canplas Industries Ltd.
1. Design: Chimney style design allows ventilator to
harness wind energy and create pressure variances
that draw air out from within the attic space. Roof
pitch range 3/12 to 12/12. Net free venting area of
130sq.in.(838sq.cm).
2. Construction: Injection molded from pure, high grade
polypropylene with premium UV inhibitor additives.
Engineered to resist denting, peeling, extreme heat
andcoldimpactto-40degreeF(-40degreeC).
3. Tested and passed the Miami Dade County TAS No.
100(A)-95110mph(177kmh)winddrivenraintest.
4. Model:Black(60PRO150BL)21-1/8inchesx21-1/8
inchesx22inches(536mmx536mmx559mm).
5. Model:Brown(60PRO150BR)21-1/8inchesx21-1/8
inchesx22inches(536mmx536mmx559mm).
6. Model:Gray(60PRO150G)21-1/8inchesx21-1/8
inchesx22inches(536mmx536mmx559mm).
7. Model:Weatherwood(60PRO150WW)21-1/8inches
x21-1/8inchesx22inches(536mmx536mm
x559mm).
E. Product: 2 TIER WeatherPRO PROVentilator as
manufactured by Canplas Industries Ltd.
1. Design: Chimney style design allows ventilator to
harness wind energy and create pressure variances
that draw air out from within the attic space. Roof
pitch range 3/12 to 12/12. Net free venting area of
95sq.in.(613sq.cm).
2. Construction: Injection molded from pure, high grade
polypropylene with premium UV inhibitor additives.
Engineered to resist denting, peeling, extreme heat
andcoldimpactto-40degreeF(-40degreeC).
3. Tested and passed the Miami Dade County TAS No.
100(A)-95110mph(177kmh)winddrivenraintest.
4. Model:Black(60PRO140BL)21-1/8inchesx21-1/8
inchesx19-1/2inches(536mmx536mmx495mm).
5. Model:Brown(60PRO140BR)21-1/8inchesx21-1/8
inchesx19-1/2inches(536mmx536mmx495mm).
6. Model:Grey(60PRO140G)21-1/8inchesx21-1/8
inchesx19-1/2inches(536mmx536mmx495mm).
7. Model:Weatherwood(60PRO140WW)21-1/8inches
x21-1/8inchesx19-1/2inches(536mmx536mm
x495mm).
F. Product: 1 TIER WeatherPRO PROVentilator as
manufactured by Canplas Industries Ltd.
1. Design: Chimney style design allows ventilator to
harness wind energy and create pressure variances
that draw air out from within the attic space. Roof
pitch range 3/12 to 12/12. Net free venting area of
48sq.in.(310sq.cm).
2. Construction: Injection molded from pure, high grade
polypropylene with premium UV inhibitor additives.
Engineered to resist denting, peeling, extreme heat
andcoldimpactto-40degreeF(-40degreeC).
3. Tested and passed the Miami Dade County TAS No.
100(A)-95110mph(177kmh)winddrivenraintest.
4. Model:Black(60PRO130BL)21-1/8inchesx21-1/8
inchesx17inches(536mmx536mmx432mm).
5. Model:Brown(60PRO130BR)21-1/8inchesx21-1/8
inchesx17inches(536mmx536mmx432mm).
6. Model:Grey(60PRO130G)21-1/8inchesx21-1/8
inchesx17inches(536mmx536mmx432mm).
7. Model:Weatherwood(60PRO130WW)21-1/8inches
x21-1/8inchesx17inches(536mmx536mm
x432mm).
PART 3 EXECUTION
3.1 EXAMINATION
A. Do not begin installation until substrates have been
properly prepared.
B. If substrate preparation is the responsibility of another
installer, notify Architect of unsatisfactory preparation
before proceeding.
3.2 PREPARATION
A. Clean surfaces thoroughly prior to installation.
B. Prepare surfaces using the methods recommended by
the manufacturer for achieving the best result for the
substrate under the project conditions.
3.3 INSTALLATION
A. Install in accordance with manufacturer’s instructions
and in proper relationship with adjacent construction.
3.4 FIELD QUALITY CONTROL
A. ProvideinspectioncerticatesofAuthorityHaving
Jurisdiction(AHJ).
3.5 PROTECTION
A. Protect installed products until completion of project.
B. Touch-up, repair or replace damaged products before
substantial completion.
END OF SECTION
Specications

- 19 -
Notes

- 20 -
Canplas, manufacturer of Durao ventilation
products,hasover45yearsofplasticsmanufacturing
experience. This expertise allows Durao to
continue as the innovation leader in roof ventilation.
Throughout our history Durao has listened to you,
the customer, to create solutions to meet your
building needs. In developing and maintaining an
open dialogue with both our internal and external
partners, we have created a wide variety of unique
products second to none in the marketplace.
CANADA
Canplas Industries Ltd.
P.O. Box 1800, 500 Veterans Drive
Barrie, Ontario
Canada L4M 4V3
1-800-461-5300
Tel: (705)726-3361
Fax: (705)726-2186
www.durao.com
USA
Canplas LLC
11402 East 53rd Ave., Suite 200
Denver, Colorado
U.S.A. 80239
1-888-461-5307
Tel: (303)373-1918
Fax: 1-888-461-5309
Molding a better future
®
www.arcat.com www.csc-dcc.ca www.csinet.org
PRINTED IN CANADAGD-02057-10-15
This manual suits for next models
2
Table of contents
Popular Fan manuals by other brands

Monte Carlo Fan Company
Monte Carlo Fan Company 3MO52 O-V1 Series Owner's guide and installation manual

Hunter
Hunter 21538 Manual de Installatión y Operatión

Hunter
Hunter 23979 Manual de instalacion y operacion

Hunter
Hunter 21575 Owner's guide and installation manual

Monte Carlo Fan Company
Monte Carlo Fan Company 5COM52 D Series Owner's guide and installation manual

Brandson
Brandson 301480 user manual