Do not attempt to install the unit yourself unless you are a trained service technician. Otherwise,
this may affect the safety and proper functioning of the unit.
Read this manual thoroughly and carefully before beginning to use the unit, ensuring safety and
proper function. Please keep it well for later reference.
Features
Drying hands without contact is hygienic.
Electricity cost saving because of drying hands at high speed.
Do not use towels and tissues, no dispose of waste.
Anti-bacteria and environmental materials, no pollution.
Thanks to heater switch is possible to set the cool or warm drying temperature:
• Heating switch to 1 (on), means the heating is always on, ambient temperature can not effect
the heating.
• Heating switch to 0 (on), means the heating is automatic working, this means:
» When the ambient temperature is below 22°C, the heating is on working, the hand dryer can
bring the warm air to the user.
» When the ambient temperature is over 22°C, the heating is not working, the hand dryer only
Thank you for purchasing our product.
Before using this unit, please read this manual in order to avoid improper handling and use
of the device.
Packing List
Unit
1
Mounting plate
1
5mm Expansion pipe
6
5x30mm Self-tapping screw
6
User Manual (include Packing List and Warranty Card)
1
Method of use figure
1
The English version of the manual is an exact translation of the original manufacturer‘s instructions.
Images used in this manual are for illustrational purposes only and may differ from the actual product.
EN
bring the cool wind.

EN
drain tank
air flow
air inlet
1
No need windpipe
Contents
Contents Features Specifications 1
Warning 2
Part name and Dimensions 3
Using the Dryer 4
Routine cleaning
Electrical schematic
5
6
7
8-9
9
0
Trouble shooting & Precautions before installation
Installation Procedures
Test run
Packing list
Features
Touchless hand dryer with less gap of u-shape, high efficiency air filter highlights hygiene.
Electricity cost saving because of drying hands at high speed.
,
It s economical & practical.
Anti-damage timer, use unworried.
Do not use towels & tissues, no dispose of waste.
Anti-bacteria & environmental materials, no pollution.
Automatic heating, drying hands comfortably during the winter.
Drying hands with ambiant air during the summer.
Anti-damage timer
Installed anti-damage timer : this machine will stop after working 25 seconds. Draw out your hands and
put again into the dryer to continue to use it.
Specifications
2
High and low sensors Design in accordance with
human engineering.
3
Heating Type
Motor Type
Rated Power
N.W. / G.W.
Heating Power
Rated Voltage
Wind Velocity
Dimensions
Induction Method
9.5/11.5KG
550W
AC110-130V
PTC PTC
1000-1300W 1250-1650W
Heater Strip Heater Strip
1300-1750W 1450-1900W
95-100m/s
300x220x699mm
IR Bolcking
1000W
AC220-240V
Brushless DC Motor Brush Motor
7/9KG
separate air supply, quite hygienic
No drip comes into the unit Prevent water drops from
spattering on the body ease of use
15

Prohibited
Do not use in
the bathtub
or shower room
Do not allow
The unit get wet
Prohibit
disassembling
Please do
complying
with instruction
Ground
WARNING
Do not open the front panel. Otherwise,
this may get an electric shock
Children forbidden hanging on the machine,
there are risk of falling.
Do not use in a wet environment, for example, near the
bathroom where it may get the direct water and the places
where the condensation may form. Otherwise, this may
cause electric shock and unit malfunction.
Do not allow the unit get wet.otherwise,
it will cause electric shock
Do not modify and disassemble the unit unnecessarily.
Otherwise,this may cause a fire,electric shock,or personal injury.
Rated power is required.
If power tolerance is over +/-10%, there will be breakdown
If using incorrect power supply, fire, electric shock
and machine malfunction will happen.
Please use dedicated socket
If using together with other appliances, the socket
may cause abnormal heat leading to fire.
Power must be cut off when maintenance to prevent
the risk of electric shock.
Drain tank and air filter must be installed.
Do not switch on after power connected for 10 seconds.
,
If the machine doesnt work or have abnormal conditions,
please cut off power to prevent accidents; and close leakage
circuit breaker and ask supplier to check and repair, or it may
lead to fire because of electricity leakage and short circuit
It must have the reliable grounding wire (only for brushless motor machines),
otherwise it may cause electric shock risk when the unit failure or leakage
Attention when installation:
Do not install when the machine is power connected.
The installation must be operated by a professional technicien.
If the installation is incorrect, it may cause electric shock and fire accident
This appliance is not intended to be used by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they are supervised
or instructed concerning use of the
appliance by a person responsible for their safety.
If the cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
For additional protection, the installation of a residual current
device (RCD) having a reted residual operating current not
exceeding 30mA is advisable in the electrical circuit supplying
the bathroom. Ask your installer for advice.
WARNING
personal injury accidents will happen if use improperly

Part name and Dimensions
Installation Panel fixed screw
(4x25 tapping screw)
Installation Panel
Accessories
……………6
……………………………1
HEPA Filter
Drain Tank
Drainage Line
Power Switch Heat Switch
Speed Governor
699mm
699mm
220 mm
70 93
Top View
Drain tank
201mm

Using the Dryer
Stretch out both hands and insert them all the way in.
The unit starts to run automatically.
Pull them out slowly, letting the air blow the water off.
Pull them out completely.
Self-check indicator
When a malfunction or error occurs, the self-check indicator on the right side will either light up
or flash.
Turn off the power switch, wait about 40 seconds until all the indicators go off, then turn on the
power switch.
If the indicator still lights up or flashes, turn off the power, disconnect the unit from the socket, and
contact your dealer immediately.
when using the unit
Turn on the power switch.
The power indicator lights up.
The lamp lights up.
The cover of power supply is closed.
Using the Dryer
Stay 5 seconds.

1
Routine Cleaning
Cleaning the Unit body
Before it gets obviously dirty
Clean the unit with a soft cloth.
If the unit gets very dirty, clean with a soft cloth dampened with neutral
agent, then clean with a dry soft cloth.
Remove the dirt from the sensor. (to prevent malfunction)
Only use the neutral cleaning agents.
Do not use thinner, acidic or alkaline toilet cleaners, or nylon
brush. (Otherwise, they may damage the smoothness of
surface)
Only use the alcohol to clean the U-shaped groove(hand
-drying area).(Do not use alcohol anywhere else)
※Alcohol here means the alcohol used for disinfection
(concentration under 83%).
If you use a chemical cloth, please read instruction first.
Desinfecting agents will damage your unit.
Draining and Cleaning the drain tank
Before it fills up (at least once a week)
The water blown off the hands is called “drain water”.
Empty the drain water at any moment, in order to prevent
accumulated water from exceeding the full level.
It will start smelling if the accumulated water remains in
the tank for too long time.
Pull the drain tank out in the
horizontal direction.
This ensures the drain water
does not splatter out.
Open the cover and empty
the water.
Pull the cover up with your fingers
in the direction of the arrow on top
of the cover, and then remove the
cover completely.
Wash out the interior of the
drain tank.
Close the water tank cover, and
Re-attach it to the unit as originaly.
Pay attention that the two locations
are firmly inserted.
If you wash the air filter with water,
and dry it as much as possible.
Before you clean the unit,
turn off the power switch.
Do not splatter water on
the unit
Wear gloves when cleaning.
The antibacterial coating is effective when
the bacteria exposed the coated surfaces
(See the shade areas on the figure)
The antibacterial coating becomes not
effective when the surfaces get very dirty.
Use the specific screwtool with
six angles with a screwdriver to
open the side panel.
Wipe it with a cloth.
Regular cleaning drainage routes,
can effectively inhibit bacterias.
Remove the air filter
Pull out the handle of the air filter.
Cleaning the air filter
Beat it lightly by hand or
use a vacuum cleaner.
If it is very dirty, wash it off
with cold or warm water.
Re-attach to the unit.
Insert it all the way in, until it
stops.(If it is not in place, the
dirt or dust will enter the unit
and shorten its service life.)
2
3
1
2
Note
WARNING
Caution
Cleaning the air filter
Around once a week
Note
Full level
Full level
Full level
Cover
Cover
Drain tank
Air filter
If the machine is equipped with HEPA
filter,please be sure to replace the filter every 6
months at least to prevent the air duct is blocked.
Do not expose to the fire.
(Not for HEPA filter)

Electrical schematic
Hand dryer control Electrical circuit Schematic:
POWER
POWER
AC220V
AC220V
50/60HZ
50/60HZ
Power Switch
Power Switch
PTC electric heater themoustat
PTC electric heater thermostat
Hand Dryer (BLDC Motor) Circuit
Hand Dryer (Brush Motor) Circuit
BLDC Motor
Brush Motor
Fuse
Protector
Fuse
Protector
Sensor Board
Sensor Board
Transmitter Board
Transmitter Board
Perating
indicator
Perating
indicator
Power
indicator
Power
indicator
Speed
Control
Speed
Control
Hertor Gontrol
Hertor Gontrol
Hall sensor
Temperature
Detector
Temperature
Detector
LED
LED
MOTOR-
MOTOR+
HOT
HOT
LN
NPE L

The mounting screw holes
Fixing screw
Fixing screw
Machine hanging hole
Wall screw into position
Expansion screw drilling
Do not install in the following types of location, otherwise this may cause malfunction:
Locations where the temperature can exceed -10 C or 40 C.
Locations where the unit may come into direct contact with water.
Locations where the unit is under direct or strong sunlight.
Locations where there is a lot of condensation.
Locations where corrosive, neutral, or reductive gases are present.
Places lower than -20m or higher than 2000m above sea level.
Installation location
Install the unit where it will be easy to use, as shown in the figure.
If the unit is installed too low, water may get on it when the floor is being cleaned. (The bottom of the
unit must be at least 150 mm higher than the floor or any objects under it.)
The left side of the unit must be at least 150 mm away from any walls, because the side door to
access to drainage route is located on the left.
Ensure there are no mirrors or walls near the right side, as drops of water may splatter to the right
when drying hands. (Recommended distance is at least 100 mm.)
Avoid locations where people or doors might bump to the unit.
Choose a completely flat surface on the wall to install the unit.
Installation Base
If your space is limited and the condition of wall is not strong enough,
you can purchase an installation base to install this unit.
Trouble shooting & Precautions before installation
If you discover the following circumstance, please inspect and handle as following:
Problem
No air blows when
stretch hands into
U-shaped groove
Machine works long
time after hands
drawn out, finally
stop
No hot wind
Airflow is too low
Status Indicator
flashes Is the reaction plate
activated for a long
time
Firstly turn off the machine, put a screen that
block 3-way sensor completely in the middle of
the sensor. Then turn on the machine over 3s,
remove the screen. Start to detect 1-3 sensors, let
it respectively and automatically flash, try to work
properly after completion of the focus.
can
Check
Do the display indicators
lights up?
Is the power switch on?
Are you putting your hands
all the way in?
Any dirt or foreign body
on sensor?
There is a Built-in heater
in the unit. Any dirt on
heating sensor?
Fuse inside terminal box
blown?
Is the speed button on
low level?
Action
Turn the ground-fault circuit breaker on.
Turn the power switch on.
Put your hands in again.
Switch off the power button, and then remove
dirt or foreign body on sensor after the power
light off When finished, switch on power
button.
Is the ambient temperature higher than 22°C?
Switch off power, remove front cover. There is
a terminal box inside. Take down the cover of
terminal box. Check the fuse inside box which
is blown or not.
Put speed button on the high level.

Installation Procedures:
Attach the installation panel to the wall
using the 6 installation screws.
If the wall is concrete, use commercially
available metal screw plugs (curl plugs,
etc.).
If the wall is not concrete, reinforce it
before installation.
2
USE Uni directional AC power supply (Do not be used with a power supply exceeding 10% )
+
_
2 2 2 2
Use a multiplied wire power cord which is 1.5mm - 2.0mm multiplied wire (Cords other than 1.5mm - 2.0mm
single-core cords cannot be used.) 2
(A drop in voltage is possible if the power cord exceeds 11 m length, so we recommend using a 2mm cord.)
Before installing the product please remove the test line.
Wire the unit.
Embed the switchbox in the installation location
(1 switchbox no cover) and wire the power cord
(with the green and yellow combined is ground line).
If no switchbox is used, the power cord will be
pushed out, and prevent the unit from being
installed firmly against the w
all.
1Power cords
(with ground line)
630mm
400mm
Pull the separate line power cord into the
unit and secure inside.
(1) Pull the power cord through the power cord
hole on the rear of the unit, attach the rear
side to the 3 hooks on the installation panel,
and secure with the installation screws
(temporarily fixed on the unit side) while
pushing the unit against the wall lightly.
The installation screws for the unit will not
tighten completely if the hooks at the bottom
of the installation panel are not in place.
Ensure the lower hooks are completely
hooked to the rear of the unit.
Note: Ensure the unit is hooked on the
installation panel, tightened the safety
screws (at the low right), otherwise, the
unit may drop or may be theft easely.
3
Strip the wire sheath as shown in the figure at
right.
Loosen the screws on the terminal box and
connect the power cord to the terminal box.
Remove the protective seal attached to the
terminal box before connecting the ground wire.
Tighten the screws on the terminal box and pull
the power cord to make sure it is secured firmly.
Bind the power cord using the clip to the right of
the terminal box and fix it to its original location.
Wire the terminal box. (There is no polarity.)
4
Do not connect ground line
(Brush motor machine)
Connect ground line
(Brushless motor machine)
15mm
The mounting screw holes
Fixing screw
Fixing screw
Machine hanging hole
Wall screw into position
Expansion screw drilling

Place the terminal box tabs into the holes and
return the cover to its original position, secure
it with the screw.
Attach the terminal box cover.
1.Attach the drain tank.
2.Make sure the air filter is all the way in.
Test Run
1
2
3
4
5
Step Check Result
Check the voltage of power supply
Turn the ground-fault circuit breaker on
Turn the power switch on
Dry hands
Check the unit
Is single-phase alternating current 210V-250V
used?
Does the power indicator light up?
Is the air blowing?
Is the unit installed firmly? Any vibration or
strange noise?
Do not turn the unit power switch on with your hands inside.
If the self-check indicator in the display lights or is flashing, turn the power switch off, and turn the power back on when all
the indicators go off (after 40 seconds).
5
6
Test Run
front panel
drain tank
installation screw

N’installez pas l ’appareil vous-même si vous n’êtes pas un technicien expérimenté. Autrement,
vous pourriez nuire au bon fonctionnement de celui-ci.
Lisez ce manuel attentivement avant de commencer à l’utiliser. Prennez connaissance des
consignes de sécurité. Gardez ce manuel pour vous y référer ultérieurement.
Ecologie : Consommation électrique faible grâce à l’air pulsé permettant un séchage rapide.
Plus de papier, plus de tissus = Moins d’empreinte carbone = Moins de pollution.
Grâce au commutateur de chauffage, chauffez ou pas l ’air diffusé :
• Chauffage sur 1 (on): le chauffage fonctionne en continu, la température ambiante n’a aucune
influence.
• Chauffage sur 0 (on), le chauffage est auto-régulé :
» Quand la température ambiante est inférieure à 22°C, le chauffage est activé.
» Quand la température ambiante est supérieure à 22°C, le chauffage est désactivé.
Merci d’avoir acheté notre produit.
Avant d’utiliser celui-ci, veuillez lire ce manuel d’utilisation afin d’éviter tout risque et de
profiter pleinement de ses performances.
Liste de Colisage
Sèche Main
1
Plateau de Montage
1
5mm Chevilles
6
5x30mm Visses à Tapper
6
Manuel d’utilisation (avec Packing List et carte de Garantie)
1
Figurine d’utilisation
1
La version française de ce manuel est la traduction exacte de celui fourni par le fabricant en anglais.
Les images utilisées sont fournies afin de fournir un support visuel et peuvent différer de la réalité.
Caractéristiques Générales
Hygiène : Se sécher les mains sans contact. Surfaces traitées Antibactériennes.
FR

FR
Caractéristiques Techniques
Type de chauffage
Type de Moteur
Puissance d’entrée
Poids Net/Poids Brut
Puissance Chauffage
Voltage
Vitesse de l’air
Dimensions
Méthode d’Induction
9.5/11.5KG
550W
AC220-240V
PTC PTC
1000-1300W 1250-1650W
Bande Chauffante
1300-1750W 1450-1900W
95-100m/s
300x220x699mm
Bloquant IR
1000W
AC220-240V
Brushless DC Motor (moteur Digital) Brush Motor (moteur à balais)
7/9KG
15
Bande Chauffante

ATTENTION
Un mauvais Usage de cet appareil peut causer des blessures

Nom des composants et Dimensions
Visses d’Installation du Paneau
(4x25 tapping screw)
Panneau d’Installation
Accessoires
……………6
…………………………1
Super Filtre
Réservoir
Ligne de Drainage
Commutateur Température
Régulateur de vitesse
699mm
699mm
220 mm
70 93
Vue du Haut
Réservoir
201mm

Utilisation de l’appareil
Utilisation

1
Nettoyage Usuel
Nettoyer le corps de l ’appareil
AVANT qu’il ne soit trop sale
Vidanger et Nettoyer le réservoir de Drainage
AVANT qu’il ne soit Plein et Minimum une fois par Semaine
1. Ouvrir le couvercle et vider l’eau.
Retirer le réservoir en le tirant
horizontalement.
Retirer ensuite le couvercle.
2. Nettoyer à grande eau l’Intérieur
du Réservoir.
3. Close the water tank cover, and
Re-attach it to the unit as original.
Assurez-vous que les deux
entailles sont bien insérées
Si vous nettoyez le filtre à air à l’eau,
Séchez-le le mieux possible.
Couper l’alimentation avant
de nettoyer l’appareil.
Ne pas éclabousser
l’appareil.
Porter des Gants lors du Nettoyage
Utiliser l’outil à 6 pans
fourni pour Ouvrir le
Panneau Latéral,
Nettoyer avec un Chiffon.
Un nettoyage régulier,
diminue considérablement
Retirer le filtre
Enlever le Filtre de son support.
Nettoyer le Filtre à Air
Battre le Filtre légèrement avec la main
Utiliser ensuite un aspirateur.
Le Laver à l’eau chaude ou froide
s’il est vraiment sale.
Rattacher le Filtre à l’appareil
Insérer le Filtre jusqu’à la butée.
Un Filtre mal positionné laisse
passer des poussières et des
saletés. Ce qui peut réduire la
2
3
1
2
AVERTISSEMENT
ATTENTION
Nettoyer le filtre à air
au moins une fois par semaine
Note
Niveau Max
Couvercle
Filtre
Si vous appareil est équipé d’un filtre HEPA,
Assurez-vous de le remplacer, au moins, 2
fois par an, afin de prévenir les blocages.
Ne pas exposer au feu.
les bactéries le long du canal
de drainage.
Niveau Max
Couvercle
durée de vie de votre appareil.
Le traitement Antibactérien est effectif dès
qu’une bactérie touche la surface traitée.
Le traitement Antibactérien est inéficace
quand la surface est trop sale.

Schémas électriques
Hand dryer control Electrical circuit Schematic:
POWER
POWER
AC220V
AC220V
50/60HZ
50/60HZ
Power Switch
Power Switch
PTC electric heater themoustat
PTC electric heater thermostat
Hand Dryer (BLDC Motor) Circuit
Hand Dryer (Brush Motor) Circuit
BLDC Motor
Brush Motor
Fuse
Protector
Fuse
Protector
Sensor Board
Sensor Board
Transmitter Board
Transmitter Board
Perating
indicator
Perating
indicator
Power
indicator
Power
indicator
Speed
Control
Speed
Control
Hertor Gontrol
Hertor Gontrol
Hall sensor
Temperature
Detector
Temperature
Detector
LED
LED
MOTOR-
MOTOR+
HOT
HOT
LN
NPE L

Dépannage & Précautions avant installation
This manual suits for next models
1
Table of contents
Languages:
Popular Dryer manuals by other brands

Zanussi
Zanussi ZDC82B4PW user manual

Whirlpool
Whirlpool Gold GGQ8831LL0 Cycle descriptions

Maytag
Maytag Performance Series W10057353A Use and care guide

Whirlpool
Whirlpool Cabrio W10720369C quick start guide

Whirlpool
Whirlpool WED9250WH installation instructions

Whirlpool
Whirlpool LEV4634JQ0 installation instructions