EcoSpring ES300 Operating instructions

INSTALLATION & OWNER’S MANUAL
Thank you very much for purchasing our product,
Before using your unit, please read this manual carefully and keep it for future reference.
ALL IN ONE Type Air-source Heat Pump Water Heater
EcoSpring ES300

HOT WATER CAN BE DANGEROUS
Warning – Hot water burns. As a safety precaution, young children should always be supervised around
hot water fixtures.
Heat pump water heaters can store water at temperatures that can cause scalding. Water temperatures
over 50°C can scald and care needs to be taken to ensure that injuries do not occur through incorrect
use of your water heater.
As heat pump water heaters can generate water temperatures in excess of 60°C, regulations require
that a tempering valve be fitted to the heater to prevent water temperatures going to the home exceed-
ing a preset safe maximum. The tempering valve must be connected to the hot water outlet line from
the water heater. The valve must be fitted by an authorized plumber at the time of installation or in retro-
fitting to existing systems.
Care should be taken to avoid coming into contact with any pipe work or fixtures associated with the
water heater pipe lines.
Under NO circumstances should any ‘home handy man’ type modifications be
attempted.
• This appliance is not intended for use by persons (including children) with reduced physical sensory
or mental capabilities, or lack of experience and knowledge, that prevents them from using the appli-
ance safely without supervision or instruction.
Children should be supervised by a responsible
person for their safety to ensure that they do not play with the appliance.
• DANGER: Failure to operate the relief valve easing gear at least once every six months may result
in the water heater exploding. Continuous leakage of water from the valve may indicate a problem
with the water heater.
•
THE INSTALLATION MUST COMPLY WITH THE REQUIREMENTS OF AS/NZS 3500.4, AS/NZS 3000, and
all local codes and regulatory authority requirements. In New Zealand, the installation must conform
to the New Zealand Building Code G12.
The power supply must be protected by an individual circuit breaker at the main electrical supply
switchboard and rated to suit the booster size. The supply to the heat pump water heater can be oper-
ated directly from the switchboard or via a remotely mounted switch or time clock as requested by the
customer. The heater must be provided with a suitable means for disconnecting the power supply.
WARNING
This unit is required reliable earthing
before usage, may otherwise result in
death or injury.
If you can't make sure that your house power supply is earthed
well, please don't install the unit.
The unit must be installed by a licensed tradesperson and in
accordance with:
•
EcoSpring installation instructions.
•
AS/NZS 3500.4-"National Plumbing and Drainage Code Hot
Water Supply Systems-Acceptable Solutions".
•
AS/NZS 3000-Wiring Rules.
•
Local authority regulations.
•
NZ Building Code.
•
Local Occupational Health and Satety (OH&S) Regulations.
This water heater must be installed by a licensed person as required by the Building Code. Only a
licensed person will give you a compliance certificate, showing that the work complies with all the
relevant standards.
NOTICE TO CUSTOMERS
Please read and understand this booklet.If you have any questions,please contact our service repre-
sentative on 0800 200 510.

PARTS NAMES
NOTE
All pictures in this manual are for explanation purpose only. They may be slightly different from the heat pump water heater you
purchased. The actual unit shall prevail.
Front Cover
Electronic Control Box
Compressor
Display
Front Decorative Board
Electric Element Cover
Thermostat TCO
Electric Element
TPR Valve
Water Outlet
Rear Cover
Junction Box
Junction Box Cover
Top Cover
Air Inlet
Fan Unit
Evaporator
Filter
Air Outlet
Thermostat Cover
Thermostat TOD
Water Inlet
Anode Rod
Drain Pipe
Solar Sensor
Solar Water Inlet
Solar Water Outlet

3
Installation & Owner‘s Manual
CONTENTS PAGE
WARNING
2. SAFETY INFORMATION
Please read thoroughly all of the instrucitons before installing or
operating the unit.
The following safety warnings are very important, always read and
obey all safety symbols:
● The unit must be earthed effectively.
●This appliance must be installed in accordance to AS/NZS stan-
dards and the NZ Building code.
● A RCD breaker must be installed adjacent to the power supply.
●
Do not remove, cover or deface any permanent instructions,
lables, or the data label from either the outside of the unit or
inside of unit panels.
●Only qualified persons should perform the installation of this unit
in accordance with local national regulations and this manual.
Improper installation may result in water leakage, electric shock
or fire.
● Ask qualified person for relocating, repairing and maintaining the
unit.
Improper installation may result in water leakage, electric shock
or fire.
●Electric connection work should comply with the instructions of
local power company, local electric utility and this manual.
●Never use an incorrectly fuse rated, otherwise the unit may break
down and risk of electrical fire.
● Do not insert fingers, rods or other objects into the air inlet
or outlet. The fan is rotating at high speed, and may cause injury.
● Never use a flammable spray such as hair spray, lacquer paint
near the unit. It may cause a fire.
●
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
NOTE
Above calculations are based on ideal conditions, the final
amount will be different the actual running will vary with
conditions, such as running period, ambient temperature, etc.
01234567 8 9 10 11 12 13
HWHP
Gas Burner
E-heater
Running Cost
Fig.1-1
1. BASIC OPERATION PRINCIPLE
We know from experience, the natural flow of heat, moves from a
higher to a lower temperature source, a heat pump can transfer heat
from a lower temperature source to a higher temperature source with
high efficiency.
The advantage of a heat pump water heater is that it can supply more
heat energy, normally 3:1 times than input electricity power by
extracting the heat from ambient atmosphere in a free-of charge way
and transfer to Sanitary Hot Water. Compared to a traditional water
heater, such as electric water heater or gas burner water heater, their
efficiency is normally less than 1:1, which means you can dramatically
cut off the bill of family daily SHW by the application of heat pump
water heater, the following examples will show more details.
Power consumption comparison under the same condition to heat 1
ton of water from 15˚C to 55˚C.
Q=cM(T1-T2)=1(kCal/kg*℃)X1000(kg)X(55-15)(℃)=40000kCal=168MJ
=46.67kW*h
3
3
4
6
12
12
18
20
21
BASIC OPERATION PRINCIPLE..........................................................
SAFETY INFORMATION......................................................................
BEFORE INSTALLATION......................................................................
INSTALLATION......................................................................................
OPERATING INSTRUCTIONS...........................................................
OPERATION ..........................................................................................
TROUBLE SHOOTING.........................................................................
MAINTENANCE.....................................................................................
SPECIFICATIONS..................................................................................
Table 1-1
HPWH Gas Burner E-heater
Energy
Resource Air,Electricity Gas Electricity
Transfer Factor 860kCal/kW*h 8905kCal/m³860kCal/kW*h
Average
Efficiency
(W/W) 3.5 0.8 0.95
Unit Cost 0.25 NZD/kW*h 2.2C/MJ 0.25 NZD/kW*h
Running Cost
NZD 12.284.623.33
13.33kW*h 210MJ 49.13 kW*h
Energy
Consumption

4
Installation & Owner‘s Manual
Table 3-1
Accessory Name Qty. Sharp Purpose
1
Owner’s & Installation
Manual
Installation and use instruction
This manual
1
Drain pipe for
water condensation
Use for draining the condensate
water (Has been connected to
the lower condensate drain port)
by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
●
If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person.
●
DISPOSAL: Do not dispose this product as
unsorted municipal waste. Collection of such
waste separately for special treatment is neces-
sary. Do not dispose of electrical appliances as
unsorted municipal waste, use separate collec-
tion facilities. Contact your local government for
information regarding the collection systems
available.
3. BEFORE INSTALLATION
3.1 Unpacking
3.1.1 Accessories
3.1.2 How to transport
1) In order to avoid scratching or deforming
the unit surface, apply guard boards
to the contacting surfaces.
No contact of fingers and other things
with the vanes.
Don’t incline the unit more than 45°
in moving, and keep it vertical when
installing.
2) This unit is heavy, it needs to be carried by two or more persons,
othewise might cause injury and damage.
3.2 Location requirements
1) preserved.
2) The air inlet and outlet should be free from obstacles and strong
wind.
3) The base surface should be flat, surface should be inclined no
more than 2° and able to bear the weight of the unit and suitable
for installing the unit without increasing noise or vibration.
4) The operating noise and air flow expelled should not affect
neighbors.
5) No flammable gas nearby.
6) It should be convenient for piping and wiring.
7) If it is installed in indoor space, it might cause indoor temperature
to decrease and noise disturbance, Please take preventive
measures for this.
8) If the unit has to be installed on a metal part of building, make
sure the electric insulation meets the relevant local electric
Gradient limit>45°
CAUTION
●The earthing pole of socket must be well grounded, make sure
that powersupplysocket andplugare dry and connected tightly.
● Before cleaning, be sure to stop the operation and turn the
breaker off or pull out the power plug. Otherwise, an electric
shock and injury may be caused.
●Watertemperatureover50℃can
cause severe burns instantly or
death from scalds. Children,
disabled and elderly are at
highest risk of being scalded.
Feel water before bathing or
showering. Water temperature
limiting valves are required as
●Do not operate the unit with a wet hand. An electric shock may
be caused.
●The installation height of power supply should be over 1.8m, if
there is any water exposure, steps must be taken to separate
the power supply from water.
well as an isolation value.
during operation. But, if there is a large volume of water, call
your service agent for instructions.
After long term use, check
the unit base and fittings. If damaged, the unit maysink, resulting
in injury. Arrange the drain pipe to ensure smooth draining.
Improper drainage work may cause wetting of the building,
furniture etc.Do not touch the inner parts of the controller or
remove the front panel. Some parts inside are dangerous to
touch, and damage may be caused.
●
Do not turn off the power supply.
System will stop or restart heating automatically. A continuous
power supply for water heating is necessary, except service
and maintenance.

5
Installation & Owner‘s Manual
Place like kitchen where oil permeates.
Place where strong electromagnetic waves exist.
Place where flammable gases or materials exist.
Place where acid or alkali gases evaporate.
Other special environments.
Use appropriate tools and equipments to transport the unit,
and ensure the unit is not damaged during transportation.
If the unit has to be installed on a metal part of the building,
electric insulation must be installed, and the installation must
meet relevant AS/NZS standards for electric devices.
Installation space and duct connection
Before installing the unit, leave enough space for sufficient air
flow and ease of maintenance as shown in figure 3-1 to 3-6
below.
Fig.3-2
Indoor installation
Display
≥100mm
≥150mm
190mm
Air inletAir outlet AB
Fig.3-1
Water inlet &
outlet
Anode & Coil
PTR Valve
Display
≥100mm
≥500mm
190mm
Air inlet
Air outlet A
Fig.3-3
Water inlet &
outlet
Anode & Coil
PTR Valve
≥450mm
Display
≥100mm
≥150mm
190mm
Air inletAir outlet B
Fig.3-5
Fig.3-6
Water inlet&
outlet
Anode& Solar
Coil
PTR Valve
≥600mm
Fig.3-4
Do not install the unit near the following.
Note:
The insataller will need to check on water quality before
installation. This could have an impact on the operation of the unit
and the warranty.

6
Installation & Owner‘s Manual
Fig.4-1
WARNING
4. INSTALLATION
Ask your
installer to install the air-source heat pump water
heating unit. Incorrect installation performed may result in
water leakage, electric shock, or fire.
Unit installed in a complete unsheltered open area is not
allowed.
The unit must be securely fixed and level, or else may result in
noise and vibration.
Make sure that there is space around the unit.
In places where there is strong wind such as seashore or
hillside, fix the unit in a location protected from the wind.
Carry the unit onto the site
In order to avoid scratch or deformation of the unit surface,
apply guard boards to the contacting surface.
Do not incline the unit more than 45° when moving, and
keep it vertical when installing.
This system is very heavy, it need to be carried by 2 or more
people, otherwise may cause injury or unit damage.
Install the unit.
The circulating air for every unit should be more than 700m3/h.
Make sure there is enough installation space.
Outline dimensional drawing(see Fig.4-1,Fig.4-2)
1920 mm
650 mm
Installation with cover
Different duct connection may result in slightly different system
efficiency
Fig.3-7
Outdoor Installation
190mm
Air inlet and outletboth connect with ducts.
Air inletAir outlet A+B≤10m
AB
Fig.3-8
Installation takeadvantage of warmer air source and cooler
air dispensed for other us
Air inletAir outlet
190mm
Outdoor water proof cover seperatethe inlet
and outlet air
Duct Description
≥100mm
Water inlet &
outlet
Anode & Coil
PTR Valve
Display
Display
≥100mm
≥150mm
Water inlet &
outlet
Anode & Coil
PTR Valve

7
Installation & Owner‘s Manual
CAUTION
NOTE
● Do not dismantle the TPR valve,
● Do not block off the drainage pipe,
Explosion and injury may be caused if installation do not
comply with the above instruction.
EXPLOSION
Handle
Drainage
pipe
All installed valves including Pressure Limiting Valve, Filter,
Non-return Valve, Cold Water Expansion Valve, and
Tempering Valve, must be installed as perAustrilia
and New Zealand Standards.
For indoor installation, a water tray as suggested in Fig 5-2 is
recommended to prevent leakage due to blockage during
draining.
Fig.5-2
50mm larger than
the dia. of HPWH
Max.22mm
TPR valve should be checked by lifting the valve handle up every
six months to ensure there is no blockage of the valve.
Please beware of burn caused by the high
temperature of water. The drainage pipe
should be well installed, in order to avoid
freezing in cold weather.
Hot Water
Heat Pump
Fig.4-2
5. PIPELINE CONNECTION
Pipeline Connection Sketch
Water Inlet
Anode rod
Drainpipe
Drain
TPR Valve Water Outlet
Upper
Condensate Outlet
Lower
Condensate Outlet
Coil sensor pocket
Coil water inlet
Coil water outlet
650 mm
190 mm
Junction box
Handle
Tempering Valve
Pressure Limiting &
Strainer & Non-return valve
Cold water
expansion valve
User
Fig.5-1
When installing the heat pump, please install an isolationg valve at the
drain line to the drain.
Pipeline Connection Explanation
Install the water inlet/outlet pipes/valves and pipe for TPR valve in
accordance with the AS/NZS standards.

8
Installation & Owner‘s Manual
190mm
6. DUCT CONNECTIONS
Air inlet without duct, air outlet connected to duct.
Air inlet and outlet both connected with ducts.
Air inletAir outlet
Air inletAir outlet
Air inletAir outlet
A+B≤10m A≤10m
A≤10m
Installation that does not want to have the cooler air affect the
temperature of the room.
Installatoin takes advantage of a warmer air source and
discharges the cold air into the room.
ABA
A
Different duct connection may result in slightly different system
efficiency
Fig.6-1 Fig.6-3
Fig.6-2
Air inlet connected to duct, air outlet without duct.
6.1 Indoor Installation
Installation takes advantage of the warmer air source
and ducts the cold air to other rooms where required.

9
Installation & Owner‘s Manual
Installation with rain cover Different duct connection may result in slightly different system
efficiency
Fig.6-4
6.2 Outdoor Installation
Installation uses outdoor air.
Air inletAir outlet
190mm
Outdoor rain cover seperates the inlet
and outlet air flow.
≤2
≤2
≤10
≤10 ≤2
≤2
≤5
≤5
Straight-line length (m) Bend pressure drop(Pa/Bend) Bend qty.
Straight-line pressure drop (Pa/m)
Duct Description
Duct
Round duct
Rectangle duct
Other shaped duct
Φ190
190X190
Refer to above data
Dimension (mm)

10
Installation & Owner‘s Manual
WARNING
Different duct connections may result in slightly different system
efficiency
For heat pump air outlet connected with duct, when heat pump is
operating, condensated dew will be generated outside the air
outlet duct. Please pay attention to the discharge of conden-
sated water.
The diameter of the
duct must ≥190mm, total length of the ducts should not be
longer than 10m and the maximum static pressure should not
exceed 50kPa. Bear in mind that the number of bends
should not exceed five.
There is a filter on the inlet. In terms of the heat pump connected
with duct, additional filter may be put forward to the air inlet of
duct to protect possible blockage.
(Fig.6-9 and Fig.6-10)
To drain condensated water from evaporator, please install the
heat pump on a level platform. The maximum allowed inclination
angle of the unit to the ground should be no more than 2° to the drain
vent side.
Fig.6-8
Fig.6-7
Fig.6-6
Rain
Weather shed
Rain
Weather shed
Heat pump.
Rain
Heat pump is not recommend to be installed outdoors where
there is no rain cover or weathershed.
Warning: In case of rain entering the internal components of the
heat pump, components might be damaged hence causing
physical danger. (Fig.6-6)
ΦD
Fig.6-9 Fig.6-10
Fig.6-11 Fig.6-12
Filter
Filter
inletoulet
Filter mesh
sizeshould be
approximately
1.2mm.
Drain Drain
≤2
o
In cases where the heat pump is installed outdoors, a reliable
water-resistant measure must be used to avoid water
ingress into the heat pump.
(Fig.6-7 and Fig. 6-8)

11
Installation & Owner‘s Manual
Table.7-1
7.1 Specifications of Power Supply
RSJ-35/300RDN3-B
4
15/5
30 mA
≤
0.1sec
Creepage Breaker
Earth Wire(mm )
Manual Switch(A) Capcity/Fuse
Model Name
Power Supply
MIin. Diameter of Power
Supply Line(mm
2
)
220-240V~50Hz
4
Fig.7-1
7.2 Electric Wiring Illustration
WARNING
Theunit must be installed with an Creepage Breaker near the power
and it must be effectively earthed.
Please select power cables according to above table, and
it should comply with ASNZS standards.
The power cord type designation is H05RN-F.
The power supply for the unit must be specialized according
to the rated voltage.
Earthing must be included in the power circuit, and it must be
connected with the effective external ground wire.
The wiring must be performed by qualified electrician
according to the circuit diagram.
Electric leakage protector should be set according to the
relevant AS/NZS electrical standards.
The power cord and additional display connection cord shall
be laid out neatly and properly without mutual interference
or in contact with the connection pipes or valves.
After wiringconnectionis finished, check again to ensure
the installation is correct before power is supplied.
CAUTION
7. ELECTRIC CONNECTION
2
T3:
Evaporator tube temperature sensor
TOD: Thermostat TOD
TCO: Thermostat TCO
T4:
Ambient temperature sensor
T5U:
Tank temperature sensor (upper)
TP: Discharge temperature sensor
Earthing
T5L:
Tank temperature sensor (lower)
TH: Return air temperature sensor

12
Installation & Owner‘s Manual
CAUTION
CAUTION
Don’t operate the heat pump before filling water.
Draining: If the heat pumps needs cleaning or moving, the tank should be emptied. Turn off the power supply.
See Fig.8-2:
8.1 Operating steps
8. OPERATING INSTRUCTIONS
Fig.8-2
Operation without water in water tank may result in
damage of electric element which is not covered by
warranty.
High temperature hot water may result in serious burn.
Special attention should be paid to children, disabled and
elderly in case of water burn.
Water filling Hot water outlet
Close
Water out
When water flows out of the water
outlet, the tank is full. Turn off the hot
water outlet valve and water filling
is finished.
Open
Open the cold water inlet and
hot water outlet
Cold water inlet Hot water outlet
Open
Fig.8-1
Draining
Close
Open
Drainpipe
Open
Cold water inlet
Close the cold water inlet, open the hot
water outlet and open drainpipe.
Hot water outlet
Drainpipe
Close
After draining, clost the drain pipe.
Replace the nut of drainpipe if necessary.
Before turning on this Heat Pump, please follow the steps below.
Filling water: If the heat pump is used for the first time or used again after draining the tank, please make sure that the tank
is full of water before power is turned on.
See Fig.8-1

13
Installation & Owner‘s Manual
8-2 Operating Steps
1 Control Panel Explanation
2 Display Explanation
Fig.8-3
Display
Operation
ECONOMY MODE
ALARM
FILL WATER
HIGH TEMP
TIME ON TIME OFF TIMER
CONFLICT
TEMP-SET
OUTLET TEMP
HYBRID MODE
E-HEATER MODE
ON\OFF
CLOCK
CANCEL MODE
TIME
ON
Fig.8-4
① ② ③
⑤
④
⑧
⑦
⑩ ⑨
⑥
111213
14
15
16
HIGH TEMP indicator:When the setting temperature
exceeds 50
℃
,
this indicator will illuminate..
FILL WATER indicator: When the power supply is turned
on,
it illuminates to remind you to refill water if necessary.
ALARM indicator: It will flash due to a malfunction or
protection.
TEMP-SET indicator: Shows error code if there is a problem
and displays the pre-set target temperature at other times.
LOCK
indicator
: Illuminates when display is locked.
②
①
③
④
⑤
Table.8-5
Water temperature indicator: Illuminates when the actual
water temperature exceeds 60
℃.
Water temperature indicator: Illuminates when the actual
water temperature exceeds 40
℃.
OUTLET TEMP indicator: Displays water temperature of
the upper part of the tank.
TIMER CONFLICT indicator: Illuminates when the
temperature set through Wired Controller conflicts with
that through display.
TIME OFF indicator: Illuminates when time off mode
has been set.
TIME ON indicator: Illuminates when time on mode
has been set.
CLOCK indicator: Display present time
, blanks
when screen protection is activated.
E-HEATER MODE
indicator: Illuminates when user sets
the E-heating Mode.
HYBRID MODE indicator: Illuminates when user sets the
Hybrid Mode.
ECONOMY MODE indicator: Illuminates when user set the
Economy Mode.
⑧
⑨
⑩
11
12
13
14
15
16
3 Operation Panel
Fig.8-6
Preparation before running the unit.
When you turn on the power supply, all the indicators on the
display will light for 3 seconds, the buzzer will sound and
then display the preset screen. After no operation
for 1 minute, all indicators will go out automatically except
for the Fill Water indicator flashing and tank temperature
indicator. Buzzer will sound when you press it.
When the tank is full, press the ON\OFF key, the Fill Water
indicator will stop flashing and you can continue to set other
settings. When all settings have been finished, press the
ON\OFF key again and the Fill Water indicator will go out. Then
unit can operate.
When the unit is in operation, if there is no operation or
malfunction for 20 seconds, the backlight of the display will go
out automatically except lights for the operation mode, outlet
temperature and lock indicator .
4 Operation Instruction
ON\OFF
CLOCK
CANCEL MODE
Used to turn the
unit on or off
Used to set
time
Used to cancel
timer and lock Used to set
different modes
Used to set the
OFF timer
Used to increase
time or temp.
Used to decrease
time or temp.
U
sed to set the
ON timer
ECONOMY MODE
ALARM
FILL WATER
HIGH TEMP
TIME ON TIME OFF TIMER
CONFLICT
TEMP-SET
OUTLET TEMP
HYBRID MODE
E-HEATER MODE
TIME
OFF
TIME
ON TIME
OFF
LOCK
LOCK
⑥
Water temperature indicator: Illuminates when the actual
water temperature exceeds 50
℃.
⑦

14
Installation & Owner‘s Manual
ECONOMY MODE
E-HEATER MODE
HYBRID MODE
Fig.8-7
Lock and Unlock
In order to prevent unintended operation, a special lock setting
function has been designed. If there is no operation for 1
minute, the unit will be locked automatically, and the lock
indicator will be displayed.
When the unit is locked, no settings can be changed.
Clock Setting
The clock is for a 24-hour system and the initial time is 00:00.
To make better use of this unit, it is recommended to set the
unit to accurate local time. Every time the unit is powered off,
the clock will be reset to the initial time of 00:00.
To set time
CANCEL
To unlock, press the CANCEL key for 3
seconds, the lock indicator will disappear,
all keys can be operated normally.
CLOCK
Press the CLOCK key, the minute digit of
the clock on the display will flash slowly.
CLOCK
Press the CLOCK key again, the minute
digit stops flashing while the hour digit
starts.
Press the UP and DOWN key, to adjust
the minute.
Press the UP and DOWN key, to adjust
the hour.
Fig.8-8
Press CLOCK key again or stop operation
for about 10 seconds, flashing will stop and
clock set is complete.
Fig.8-9
Mode Selection
The unit is enhanced with three operation modes, Economy
Mode, Hybrid Mode and E-heater Mode.
: The unit heats water only by compressor drive
according to heat-pump principle. Use when the ambient
temperature is high.
: The unit heats water by both compressor and
electric element. Use when the ambient temperature is low.
: The unit heats water only by electric element. Use
when the ambient temperature is very low.
To change mode
MODE
Press the MODE key, operation mode will
be shifted among the three modes in a
cycle, meanwhile the corresponding
indicator on the display will light up.
Temperature Setting
Temperature displayed is the water temperature in the upper
part of the tank. Default is 55℃, setting range is 38~60℃.

15
Installation & Owner‘s Manual
Fig.8-10
Fig.8-11
Press the UP and DOWN key, you can
Increase or decrease the water temperature.
When the set temperature is higher than
50
℃,the HIGH TEMP indicator will illuminate.
HIGH TEMP
Timer
User can set up an operating start and stop time by using the
timer function. The least duration of timer is ten minutes.
TIME ON: User can set up a start time by this. The unit will
automatically operate from the set time to 24:00 on the same
day.
To set start time
Fig.8-12
Fig.8 -13
Cancel:
CANCEL
In the unlocked state, press the CANCEL
key for 3 seconds and the TIME ON
function will be canceled.
Press the TIME ON key again or wait for
about 10 seconds, flashing stops and
TIME ON set is finished.
TIME
ON
Press the TIME ON key, the minute digit
of the clock on the display will flash slowly.
Press the TIME ON key again, the minute
digit stop flashing and the hour digit starts.
Press the UP and DOWN key, you can
adjust the minute.
Press the UP and DOWN key, you can
adjust the hour.
TIME ON and TIME OFF: Users can set up an operating start
and stop time. When the start time is earlier than the stop time,
the unit will run between the set time. When the start time is
later than the stop time, the unit will run between the start time
today and the stop time the next day, when user sets the same
start and stop time, the stop time will be automatically delayed
by ten minutes.
TIME
ON
To set temperature

16
Installation & Owner‘s Manual
To set stop time
CANCEL
In the unlocked state, press the CANCEL
key for 3 seconds, the Time on and Time
off function will be canceled
Fig.8-15
Press the TIME OFF key, the minute digit
on the display will flash slowly.
Press the UP and DOWN key, you can
adjust the minute.
Cancel:
Stop operation for 10 seconds, flashing
stops and TIME OFF is completed.
TIME
OFF
Press the TIME OFF key again, the minute
digit stops flashing and the hour digit starts.
Press the UP and DOWN key, you can
adjust the hour.
Fig.8-14
ON\OFF
NOTE
TIME ON and TIME OFF
cannot be set to the same time. If they
are the same, the stop time will delay 10 minutes automatically.
For example,
TIME ON and TIME OFF
set to 1:00 at the same
time, then the stop time will adjust to 1:10 automatically.
TIME OFF function cannot be used alone. The key can be used
only after TIME ON has been set.
User can press the ON\OFF key manually if long period is
requied.
ON/OFF key
Power On and Power Off
Press ON\OFF button after setting has been selected and the
system will run at that setting.
Fig.8-16
Operation status
The Low Ambience (LA) code from the screen of TEMP-SET
will appear to remind user when ambience temperature does not
meet the operation condition of heat pump unit
(beyond -7~43℃).
In such case, the unit will automatically switch to E-heater mode.
The unit will return to original setting automatically when the
ambient temperature meets the operating conditions of the heat
pump mode and the LA code will be disappear at the same time,
the screen will then display nomally.
TIME
OFF
Fig.8-17
Warning Code of disagree
with heat pump mode
TEMP-SET

17
Installation & Owner‘s Manual
WARNING
The covers of the electric element should not be
opened unless by a qualified electrician in order
to prevent electric shock and other dangers.
Fig.8-18
The light will illuminate in error
ALARM
Warning Code of disagree with
heat pump mode
Temp.Set
Fig.8-19
Trouble Shooting
If an error occurs, the buzzer will sound 3 times every minute
and the ALARM indicator will flash fast. Hold CANCEL for 3
seconds to stop the buzzer however the light will keep
illuminating.
The light illuminates in error
ALARM
CANCEL
Hold CANCEL key to stop the buzzer.
Fig.8-20
The error code from the screen of TEMP-SETwill display when
a malfunction happens, the system will display error code after
one minute, and when the key is pressed again and the screen
will display set temperature.
When a malfunction happens in economy mode, the system
may still be used when switched to E-heater mode. However, in
this case, the system will not reach the expected efficiency.
Error Code Explanation (See t
able.8-21
)
Fig.8-21
Display the error code
TEMP-SET
When ambient temperature does not meet the heat
pump operational requirement (outside the range -7~43℃) for
over 20 hours. “LA” will display at TEMP-SET screen and
ALARM indicator flashes simultaneously to alarm that the
temperature is not suitable for heat pump performance, only
E-heater mode could be selected at such circumstance.
Please switch to E-heater mode manually to ensure there
is adequate hot water to be supplied. Note that if change of
mode is done manually, the desired mode will not return
automatically upon unit returning to normal working process.
Desired mode must be changed back manually.

18
Installation & Owner‘s Manual
ECONOMY MODE
HYBRID MODE
Display
E0
E1
E2
E4
E5
E6
E7
E8
P2
P3
Malfunction Description*
Upper tank temperature sensor (T5U) error
Lower tank temperature sensor (T5L) error
Tank and Wired Controller communication error
Evaporator tube temperature sensor (T3) error
Ambient temperature sensor (T4) error
Discharge temperature sensor (TP) error
Heat Pump system error
Electric leakage protection
Discharge pipe temperature overheat protection
No current flowing in Compressor
Table.8-21
P4
P8
P9
Compressor overloaded protection
Upper E-heater overloaded protection
If the errors occur, please contact your installer.
Low Ambience error, ambient temperature is not in
the range of -7~43
。
C
LA
Before start, please check the following first:
Correct installation of the system;
Correct connection of pipeline, wiring and earthing;
Drainpipe connected;
Suitable pipe insularion;
Correct transportation of unit;
Correct power supply;
No obstacles outside the air inlet and outlet;
Complete bleeding air out of hot water cylinder and pipes;
Effective electric leakage protector;
Sufficient inlet water pressure(≥150kPa)
Water-heating Operating Capability
There are three types of heat sources that can be used by the
heat pump water heater: electric element, heat pump and coil.
These three sources do not work together at the same
time. Do not use the coil without consulting the supplier.
This unit has two temperature sensors in the hot water cylinder,
they are installed at the upper 1/4 and bottom 1/2. The upper one
tests the upper temperature, shown in the figure below, and the
bottom one is used to test the lower water temperature, which
will control the operation of the heating automatically.
Water-heating Operating Modes
: In this mode, the unit heats water only by compressor
drive according to heat-pump principle.
(Water outlet temp. range 38~60
℃
,running ambient -7~43
℃)
: In this mode, the system will adjust the working
capabilities of electric element and heat pump according to the
tank water temperature.
(Water outlet temp. range 38~60
℃
,running ambient -30~43
℃)
9. RUNNING AND CAPABILITY
9.1 Trial Run
9.2 Operating Capability
Tank Coil
Upper sensor
Bottom sensor
electric heater
Inlet
outlet
Fig.9-1
No current flowing in electric heater
P3
P1 System high pressure protection
P2
E9 Return air temperature sensor (TH) error
* Details refer to page 9, Fig.7-1.

19
Installation & Owner‘s Manual
Heat-up Time
E-HEATER MODE
Hybrid Mode: -30~43℃
E-heater Mode: -30~43℃
Water Temperature Display
The temperature on the display is the water temperature in the
upper part of the water tank this is approximately 75L of water
The 6 indicators beside the water temperature on the display
are for the temperature in the lower part of the tank. When the
temperature is higher than 40℃, the blue indicator will light up;
when higher than 50℃, the yellow indicator will also light up;
when higher than 60℃, all three colour indicators (blue, yellow
and red) will light up. When all indicators light up, the water
temperature has reached the set point.
When using water, the temperature of the lower part may
decrease while the upper part still keeps at a high one, and the
system will start heating the lower part. This is normal.
Trouble Shooting
When error code appears on the display or the unit is not
operating, please contact your installer.
When an error occur, the buzzer will buzz in every minute,
the warning light flashes, the display will indicate the error code
and water temperature alternatively. Press CANCEL button for
3 seconds to stop the alarm.
Restart after a period of disuse over one year
Please follow the draining and filling water instructions on
page 10 to refill the water.
NOTE
Economy mode should be used when the ambient temperature
is between -7~43℃. When the ambient temperature is under
-7℃, the energy efficiency would decrease, E-heater mode
should be used in this circumstance.
NOTE
In the E-heater mode, the water above the electric element that
is being heated is approximately 150L.
: In this mode, the compressor and the fan motor will
not run but the electric element work only.
(Water outlet temp. range 38~60
℃
,running ambient
-30~43
℃).
Defrost during Water-heating
In the Economy and Hybrid Modes, if the evaporator froze
in a cold environment, the system will defrost automatically.
(3~10 min).
Ambient Temperature
The system’s operation temperature is within -30~43℃and
below are the operation temperature for each mode.
Economy Mode: -7~43℃
NOTE
If the unit fails to restart after self-protection, Switch the power
supply off manually and restart after the error has been resolved.
Mode Selection
Different modes are designed to meet different demand and the
following are recommended selections.
Economy Mode: -7~43℃, continuous hot water demand below
250L (60℃);
Hybrid Mode: -30~43℃, continuous hot water demand between
300L~350L (60℃);
E-heater Mode: -30~43℃, continuous hot water demand around
150L (60℃).
Self-Protection
Self protection starts in the following circumstances:
Air inlet or outlet is blocked; Error Code: P1
The filter is covered with too much dust; Error Code: P2
Incorrect power supply (exceeding the range of 220-240V)
Error Code: P4
When self-protection occurs, the system will stop and begin
self-check, and restart when the problem is resolved; system will
not restart automatically if problem persists, in such case,
contact your installer
When the self-protection happens, the buzzer will buzz every
minute, the ALARM indicator flashes and the display indicates the
error code and water temperature alternatively. Press CANCEL
key for 3 seconds to stop the alarm. Buzzing and flashing stops
when the problem is resolved and error code disappears on the
display.
②
①
③
1)
2)
3)
02:00:00
03:00:00
04:00:00
05:00:00
06:00:00
07:00:00
08:00:00
-7 -2 2 7 10 15 20 25 30 35 40 43
Ambient Temp(℃)
Time(h)
15--45
15--50
15--55
15--60
Other manuals for ES300
1
Table of contents
Popular Air Conditioner manuals by other brands

Midea
Midea MSC-09HRFN1-QD2E Service manual

Artidor
Artidor AR-054 series user manual

Mitsubishi Electric
Mitsubishi Electric PLFY-P15VCM-E2 Technical & service manual

Fujitsu
Fujitsu AR A45LCTU Series Design & technical manual

Mitsubishi Electric
Mitsubishi Electric City Multi PKFY-WL NLMU-E Series installation manual

DeLonghi
DeLonghi PAC N130HPE instruction manual

Hitachi
Hitachi RAC-35N5 installation manual

BALAY
BALAY 3XD610E Instructions for use

Sinclair
Sinclair ASFU-09A user manual

Dometic
Dometic Royale Penguin 610115.411 Installation & operating instructions

Carrier
Carrier WeatherExpert 48N4 installation instructions

Mitsubishi Electric
Mitsubishi Electric CITY MULTI PEFY-P30NMAU-E5 Operation manual