Elder Audio Beta Three E200 User manual

Beta three
RR
User Manual
PROFESSIONAL POWER AMPLIFIER
E200 E300
E500 E800
ED-B3-MA-061012-001
00
-2-2
-4-4
-6-6
-8-8
-10-10
-12-12
-14-14
-16-16
-18-18
-20-20
-24-24
00
-2-2
-4-4
-6-6
-8-8
-10-10
-12-12
-14-14
-16-16
-18-18
-20-20
-24-24
E800

P1
P1
P2
P6
P7
P7
P8
P8
P9
P11
P11
P11
P12
TO USERS
Thanks for choosing Series E power amplifier(s). Please read this manual carefully prior to use
of the product. Operation must be done strictly following the instructions stated in this manual.
Please consult your â3 dealer or visit our website www.elderaudio.com for detailed information
when you have any questions.
TABLE OF CONTENTS
2.Performance Features
3.Technical Specifications
4.Installation Diagram
7.Power Supply
8.Input/Output Connection
9.Function Setting and Signal Connection
10.Operation Steps
11.Description of Front Panel Indicators
12.Protection Functions
13.Troubleshooting
1.Precautions
5.Front Panel
6.Rear panel

1
Do not remove the cover to avoid high voltage hazard. Please refer servicing to qualified
personnel.
Do not explore the unit to rain or moisture.
Do not block the ventilation of the unit to ensure cooling efficiency.
Check whether the local voltage is identical with the operating voltage of the unit.
Please disconnect the unit from the power supply when it is not to be used for a long time.
Do not let the equipment run for a long time with overload.
1.PRECAUTIONS
2.PERFORMANCE FEATURES
Symbol Definition
The equilateral triangle containing a arrowheaded lightning symbol is intended to alert the
user of the presence of uninsulated ''angerous voltage'' within the equipment's enclosure
that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The equilateral triangle containing a exclamation mark is intended to alert the user to the
presence of important operating and maintenance instructions in the literature accompanying
the appliance.
Series E products are high-performance big-power professional amplifiers which suit various
applications for sound reinforcement. The following shows the main features of Series E models.
1. High power output, big driving capacity.
2. Adoption of optimized heatsink structure and high quality cooling fans ensures system
reliability and allows the unit to run long hours with high power output.
3. Series E features interactive control over temperature of loaded impedance, power and
working voltage. Speed of the cooling fans can change automatically according to inner
temperature. When the loaded impedance is too low or the inner temperature is too high,
the equipment will adjust the power supply voltage and reduce the power supply impedance,
which helps to protect the system, and improve sound quality and reliability efficiently.
4. Low distortion
5. High slew rate helps to boost definition and achieve better sound
6. Low noise with the S/N ratio>108dB(A)
7. Frequency response: 20Hz-20KHz <+0/-0.25dB
8. 2U-rack compact design
9. E800 is specially designed for driving low impedance load, capable of driving 2 load for
a long time.

<0.05%(10% rated power
<0.1%(60Hz/7KHz,10% rated power
483 310 88mm
12Kg
AC 220V~230V,50~60Hz,250VA
90%
1V
>50V/ s
20Hz~20KHz(+0/-0.25dB)
<15
>800(8 /100Hz)
- 75dB
>108dB(A weight)
32 0.5dB
<0.25dB
8
8
16
200W
200W
400W
300W
300W
600W
4
4
8
2
3.TECHNICAL SPECIFICATIONS OF E200
Rated power
THD
Intermodulation distortion
Frequency response
Phase deviation
Damping factor
Crosstalk
S/N ratio
Total gain
Channel gain error
Input sensitivity
Slew rate
Input impedance
Input connector
Output connector
Cooling method
Front panel control
Rear panel control
Front panel indicator
Amplifier protection
Net dimensions
Net weight
Power supply
Environmental temperature
Environmental moisture
Stereo mode
Parallel mono mode
Bridged mono mode
unbalanced 10K input, balanced 20K input
3-pin XLR/6.35 socket
NL4 binding post
four stepless fans, front-to-rear airflow
AC power switch, channel 1/ channel 2 gain knob
parallel/stereo/bridge mode option, lowcut/grouding/limit parameter selection
yellow-bridge, red-overload, green-signal
short circuit/DC/overheat/overload protection
work temperature:-10 ~40 storage temperature:-25 ~80

3
<0.05%(10% rated power
<0.1%(60Hz/7KHz,10% rated power
483 375 88mm
14Kg
AC 220V~230V,50~60Hz,400VA
90%
1V
>50V/ s
20Hz~20KHz(+0/-0.25dB)
<15
>800(8 /100Hz)
- 75dB
>108dB(A weight)
33.8 0.5dB
<0.25dB
8
8
16
300W
300W
600W
500W
500W
1000W
4
4
8
Rated power
THD
Intermodulation distortion
Frequency response
Phase deviation
Damping factor
Crosstalk
S/N ratio
Total gain
Channel gain error
Input sensitivity
Slew rate
Input impedance
Input connector
Output connector
Cooling method
Front panel control
Rear panel control
Front panel indicator
Amplifier protection
Net dimensions
Net weight
Power supply
Environmental temperature
Environmental moisture
Stereo mode
Parallel mono mode
Bridged mono mode
unbalanced 10K input, balanced 20K input
3-pin XLR/6.35 socket
NL4 binding post
four stepless fans, front-to-rear airflow
AC power switch, channel 1/ channel 2 gain knob
parallel/stereo/bridge mode option, lowcut/grouding/limit parameter selection
yellow-bridge, red-overload, green-signal
short circuit/DC/overheat/overload protection
work temperature:-10 ~40 storage temperature:-25 ~80
3.TECHNICAL SPECIFICATIONS OF E300

4
<0.05%(10% rated power
<0.1%(60Hz/7KHz,10% rated power
483 375 88mm
17Kg
AC 220V~230V,50~60Hz,600VA
90%
1V
>50V/ s
20Hz~20KHz(+0/-0.25dB)
<15
>800(8 /100Hz)
- 75dB
>108dB(A weight)
36 0.5dB
<0.25dB
8
8
16
500W
500W
1000W
800W
800W
1600W
4
4
8
Rated power
THD
Intermodulation distortion
Frequency response
Phase deviation
Damping factor
Crosstalk
S/N ratio
Total gain
Channel gain error
Input sensitivity
Slew rate
Input impedance
Input connector
Output connector
Cooling method
Front panel control
Rear panel control
Front panel indicator
Amplifier protection
Net dimensions
Net weight
Power supply
Environmental temperature
Environmental moisture
Stereo mode
Parallel mono mode
Bridged mono mode
unbalanced 10K input, balanced 20K input
3-pin XLR/6.35 socket
NL4 binding post
four stepless fans, front-to-rear airflow
AC power switch, channel 1/ channel 2 gain knob
parallel/stereo/bridge mode option, lowcut/grouding/limit parameter selection
yellow-bridge, red-overload, green-signal
short circuit/DC/overheat/overload protection
work temperature:-10 ~40 storage temperature:-25 ~80
3.TECHNICAL SPECIFICATIONS OF E500

5
<0.05%(10% rated power
<0.1%(60Hz/7KHz,10% rated power
483 378 88mm
20Kg
AC 220V~230V,50~60Hz,900VA
90%
1V
>70V/ s
20Hz~20KHz(+0/-0.25dB)
<15
>800(8 /100Hz)
- 75dB
>108dB(A weight)
35 0.5dB
<0.25dB
8
8
16
800W
800W
1600W
1300W
1300W
2500W
4
4
8
Rated power
THD
Intermodulation distortion
Frequency response
Phase deviation
Damping factor
Crosstalk
S/N ratio
Total gain
Channel gain error
Input sensitivity
Slew rate
Input impedance
Input connector
Output connector
Cooling method
Front panel control
Rear panel control
Front panel indicator
Amplifier protection
Net dimensions
Net weight
Power supply
Environmental temperature
Environmental moisture
Stereo mode
Parallel mono mode
Bridged mono mode
unbalanced 10K input, balanced 20K input
3-pin XLR/6.35 socket
NL4 binding post
four stepless fans, front-to-rear airflow
AC power switch, channel 1/ channel 2 gain knob
parallel/stereo/bridge mode option, lowcut/grouding/limit parameter selection
yellow-bridge, red-overload, green-signal
short circuit/DC/overheat/overload protection
work temperature:-10 ~40 storage temperature:-25 ~80
3.TECHNICAL SPECIFICATIONS OF E800

76.2mm
376mm
371mm
465.7mm
360.5mm
482.4mm
465.0mm
ÆøÁ÷·½ÏòÆøÁ÷·½Ïò
Æø
Á÷
·½ÏòÆø
Á÷
·½Ïò
376mm
355mm
433.0mm
87.9mm
ÆøÁ÷·½ÏòÆøÁ÷·½Ïò
6
76.2mm
310mm
302.5mm
298mm
292.5mm
482.4mm
465.0mm
ÆøÁ÷·½
Ïò
ÆøÁ÷·½
Ïò
ÆøÁ÷·½ÏòÆøÁ÷·½Ïò
310mm
303mm
433.0mm
87.9mm
Æø
Á÷
·½ÏòÆø
Á÷
·½Ïò
E800/E500/E300:
E200:
4.INSTALLATION DIAGRAM
Airflow
Airflow

UA SERIESUA SERIES
RRPRO DESIGN
BETA THREE E800
BRIDGE
PEAK
SIGNAL
00
-2-2
-4-4
-6-6
-8-8
-10-10
-12-12
-14-14
-16-16
-18-18
-20-20
-24-24
00
-2-2
-4-4
-6-6
-8-8
-10-10
-12-12
-14-14
-16-16
-18-18
-20-20
-24-24
CHBCHA
POWER
ON
12
3
4
5
6
789
CHA
BRIDGE IN
CHB
PIN1:
SIGNAL GND
PIN2:
SIGNAL +
PIN3:
SIGNAL -
BRIDGE
PARALLEL
STEREO
MODE LF FILTER GROUND
CLIPLIMITER
ON
OFF
50HZ
25HZ
ON
OFF
CHB OUTPUT
CHA OUTPUT
POWER
CABLE
FUSE
ELDER AUDIO MANUFACTORY
INPUT
DELAY
T 15A/250V
AC 220V 50/60Hz
900VA
-
B
+
-
A
+
-
+
5HZ
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
BRIDGE
!
12
345
67
89
10 11
12
13 14
RMS:
STERO:
8 1 000W 2
BRIDGE: 16 2 000W
OUTPUT ASSIGNMENT:
BRIDGE MONO OUTPUT:
CHA :
PIN1+ : SIGNAL GND
CHA:
4 1 600W2
8 3 200W
PIN 1+ :
PIN 1 - :
PIN 2+ :
PIN 2 - :
CHA SIGNAL
CHA GND
CHB SIGNAL
CHB GND
CHB: PIN 1+ :
PIN 1 - :
PIN 2+ :
PIN 2 - :
CHB SIGNAL
CHB GND
PIN2+ :
7
5.FRONT PANEL
6.REAR PANEL
1.Ventilation entrance
2.Channel 1 signal indicator
3.Channel 1 overload indicator
4.Bridged mode indicator
5.Channel 2 overload indicator
6.Channel 2 signal indicator
7.Power supply switch
8.Channel 1 gain pot
9.Channel 2 gain pot
Take E800 as an example.
Take E800 as an example.
1.Channel 1 signal input (XLR connector)
2.Channel 1 signal input (1/4'' mic socket)
3.Work mode switch
4.Clip limiter switch
5.Channel 2 signal output (binding post)
6.Channel 1 signal output (binding post)
7.Fuse
8.Channel 2 signal input (XLR connector)
14.Power cable
9.Channel 2 signal input (1/4'' mic socket)
10.Filter switch
11.Grounding switch
12.Channel 1 signal output (NL4 socket)
13.Channel 2 signal output (NL4 socket)

8
7.POWER SUPPLY
8.INPUT/OUTPUT CONNECTION
Before connecting the power amplifier to the power supply, check whether the operating
voltage (AC 220V~230V, 50~60Hz) is identical with your local power supply and confirm
that neither the power supply socket nor the power cord is damaged. Remember to pull
the cord plug out of the outlet when the unit is turned off.
Input connection
The input XLR and 1/4'' mic sockets of the same channel are linked in parallel.
Signal can be input via any input socket, output via the other socket of the same channel
and then input to another power amplifier in daisy chain mode.
Too many stages of daisy chain may affect sound quality, so do not input signals via two
interfaces of the same channel.
Output connection
The output binding post and the NL4 socket of the same channel are linked in parallel.
Do not connect both outputs of the same channel with load simultaneously.
Connect the red (hot) binding post to the positive pole of loudspeaker and the black post
to the negative pole.
Connect the output end only with load that can match the power rating and load impedance
of the power amplifier.

9
CLIP
LIMITER
OFF
ON
CLIP
LIMITER
OFF
ON
+1
-2
-3
-4
-5
-6
0dB
-1
20 30 40 50 60 80 100 200 300 400 500 Hz
+1
-2
-3
-4
-5
-6
0dB
-1
20 30 40 50 60 80 100 200 300 400 500 Hz
LF FILTER
50HZ
25HZ
5HZ
LF FILTER
50HZ
25HZ
5HZ
1. Setting of clip limiter switch
When the switch is in OFF position, the clip limiter is turned off and the limiter circuit is out
of function. Excessive signal input in such situation will easily cause clipping distortion in
output signal and loudspeaker overloading.
When the switch is in ON position, the clip limiter is turned on. When there is excessive
signal input, the limiter circuit will work automatically to adjust the total gain to reduce
distortion and control the power output without affecting the instantaneous peak output.
This function offers loudspeaker protection capability while ensuring dynamic range of music.
Switching on the clip limiter is recommended when use.
2. Setting of low cut switch
Turning the low cut switch to 50Hz position equals to add a 50Hz high-pass filter in series
into the input circuit, so signals below 50Hz will be attenuated properly, which can limit the
noneffective excursion of loudspeaker and reduce the distortion, as shown in the following
diagram.
When the low cut switch is turned to 25Hz position, it is equal to add a 25Hz high-pass filter,
which will attenuate signals below 25Hz, as shown in the following diagram.
9.FUNCTION SETTING AND SIGNAL CONNECTION

10
+1
-2
-3
-4
-5
-6
0dB
-1
20 30 40 50 60 80 100 200 300 400 500 Hz
LF FILTER
50HZ
25HZ
5HZ
MODE
BRIDGE
PARALLEL
STEREO
XLR unbalanced
XLR asymetrique
unsymetri is che XLR
XLR no balanceado
1
2
3
TRS unbalanced
TRS asymetrique
TRS no balanceado
Unsymetriscbe jStereoklinke
Unbalanced
Asymetrique
Unsymmetrisch
No balanceado non-inverting input +
Ground
12
3
Balanced
Symetrique
Symmetrisch
Balanceado
Ground
inverting input -
non-inverting input +
When the low cut switch is turned to 5Hz position, all
signals within the frequency range will be amplified
accordingly, as shown in the right diagram.
1. Mode selection and signal connection
Connection diagram
Cable pin diagram
A.Stereo mode
Firstly turn the mode switch to STEREO position
on the rear panel, as shown in the picture on the
right.
In stereo mode, signals through Channel 1 and Channel
2 of the power amplifier are treated as independent
ones, which means that Channel 1 input signal will go
only to Channel 1 output, and the same is to Channel 2,
as shown in the diagram.
C.Bridged mode
Firstly turn the mode switch to BRIDGE position
on the rear panel, as shown in the picture on the right.
In bridged mode, signal can be only input via
Channel 1. Signal input via Channel 2 will not make
any sound. The positive pole of Channel 1 output
is also the positive pole of the bridged circuit. The
positive pole of Channel 2 is the negative pole of
the bridged circuit, as shown in the diagram.
To avoid electric shock that can be caused by the dangerous high output voltage, please
turn off the equipment before connecting in bridged mode!
E800 power amplifier is recommended for driving 4 load in bridged mode.
B.Parallel mono mode
Firstly turn the mode switch to PARALLEL position
on the rear panel, as shown in the picture on the right.
In parallel mono mode, signals through Channel 1
or Channel 2 of the power amplifier have the same
effect, which means that Channel 1 input signal will
go to both Channel 1 and Channel 2 outputs, and
the same is to Channel 2, as shown in the diagram.
But do not input signals simultaneously to both
Channel 1 and Channel 2.
Attention: Parallel mono mode described here is
only refered to the parallel mode of the input signals.
Please do not use the output connectors in parallel
mode.
9.FUNCTION SETTING AND SIGNAL CONNECTION

11
10.OPERATION STEPS
11.DESCRIPTION OF FRONT PANEL INDICATORS
12.PROTECTION FUNCTIONS
Please follow the operation steps below when using the equipment.
1. Start the equipment
a.Set functions and do connection in accordance with the detailed information described
in item 9.
b.Check whether the output connection is short-circuited and the load impedance is too low.
c.Check whether the local voltage is identical with the operating voltage.
d.Make sure the power supply switch on the front panel is in the ''0'' position and the volume
is minimized.
e.Connect the equipment to the power supply, turn on the sound source equipment, pre-
equipment, and effectors in sequence and confirm that all work normally.
f.Turn on the power supply switch (settled at ''1'' position ).
g.Adjust the volume by turning the knob clockwise to a proper position.
2. Turn off the equipment
a. Minimize the volume by turning the knob anticlockwise.
b. Turn off the power supply switch on the front panel (to ''0'' position).
c. Turn off the pre-equipment, effectors and sound source equipment in sequence.
1. Flashing of the signal indicator indicates that there is signal output through the two channels.
2. Flashing of the peak indicator indicates that the input level is too high and the volume must
be attenuated.
3. If the peak indicator is on continuously, it indicates that the unit is in abnormal operation
condition which is possibly caused by too low impedance load, short circuit, or overheating.
The unit must be turned off for checking and debugging before being turned on again.
4. If the bridged mode indicator is on, it indicates that the power amplifier is already in bridged
mode.
E Series power amplifiers feature full protection functions which can protect the power amplifier
and loudspeaker system against damage potentially caused by short circuit, DC output or
overheating trouble.
1. Short circuit protection:
When short-circuit problem occurs in the load end, the unit will automatically switch off the
signal input therefore protect the equipment effectively.
2. DC protection:
When there is DC element in the output signal resulting from malfunction of the unit, the
unit will automatically switch off the signal output therefore effectively protect the loudspeaker
system from the potential damage caused by DC element.
3. Overheat protection:
When the temperature of the heatsink is higher than the permitted level, the temperature
sensor inside in the power amplifier will inform the protection circuit to switch off the output
automatically, therefore avoid damage to the unit and harm to the user.

12
13.TROUBLESHOOTING
No. Troubleshooting guide
Check whether the power plug of the unit and the power
supply socket are in bad contact.
Check whether there is AC 220V/230V 50Hz/60Hz voltage
output from the power supply socket.
Check whether the fuse on the rear panel is already burnt.
Check whether the music signal cables are in good contact.
Check whether both the power supply switch and the
volume pot of the music source equipment have been
turned on.
Check whether the volume pot of the power amplifier has
been turned on.
Check whether there is excessive-amplitude signal input
from the source equipment.
Check whether the CLIP LIMMITER switch is in ON position
Check whether there exists short circuit problem in the
load end connection and ensure the load impedance to
be proper. Turn on the power amplifier again when the
problems are solved.
Check and make sure that the LF FILTER switch is in LF
50Hz or LF 25Hz position.
Check and make sure that the MODE switch is in PARALLEL
position.
Check whether the input signal level is matchable. Increase
the input level if it is not enough.
Check and make sure that the MODE switch is in BRIDGE
position.
Check and make sure that the local voltage is identical
with the operating voltage of the unit.
Check and make sure that all settings and connections
of the unit are correct in accordance with the related
instructions in the user's manual.
Consult professional personnel in the local authorized â3
products servicing centre or visit our website:
www.elderaudio.com.
1
1
2
2
3
3
1
2
3
1
1
1
1
1
2
2
Description of failures
There is no sound. The
power supply indicator is off.
There is no sound.
The power supply indicator is
on but the SIG. indicator is off.
The CLIP (overload)
indicator is on, and
there is abnormal sound.
LF sound is not enough.
One channel is silent in
paralleled mono mode.
Output is weak
in bridged mode.
Fuss is burnt after the
unit is turned on.
Other failures.

PROFESSIONAL POWER AMPLIFIER
E SERIES
RR
User Manual
www.elderaudio.com
This manual suits for next models
3
Table of contents
Other Elder Audio Amplifier manuals