Elementia Materials Plycem Eureka Tank User manual

IMPACT
RESISTANT
LIGHTWEIGHT HERMETIC HYGIENIC
DURABLE EASY TO
INSTALL
ECO-FRIENDLY EASY TO CLEAN
EUREKA TANK
Installation guide

V. 07-21
www.plycem.com
V. 10-21
www.plycem.com
1INSTALLATION GUIDE FOR EUREKA TANK
Eureka Tanks are manufactured using the most advanced
technology in rotomolding, using polyethylene resins of the highest
quality, which provides great strength, lightness and durability,
maintaining unchanged the physical properties of the stored water.
Eureka Tanks provide high resistance due to their characteristic
reinforcement belts and are o ered in two presentations; Two
layer, with a white interior layer and its traditional black color
on the outside, or three-layer with a third sand-colored layer
that provides better protection, durability and aesthetics.
Eureka Tanks are easy and quick to install, avoiding the high
masonry costs required for a traditional tank. They are also
the only ones in the market that o er a 100-year warranty.
• With an internal layer of polyethylene foam for thermal
insulation. This layer is smooth and prevents particles in
suspension from adhering.
The white color of the three-layer tanks allows to observe the
quality of the water.
• With black, sand or blue (two-layer) outer coating prevents
penetration of UV rays and sunlight (prevents algae).
• With an intermediate layer (three-layer) that resists UV
rays and protects against solar rays (prevents algae and
microorganisms).
• Lid with Click lock, seals the tank and makes it easy to close or
remove the lid.
• The flange, cover and ring are replaceable as well as the lter
and other components.
• With reinforcement struts and structured bottom
to avoid deformation of the walls and fl oor.
• In addition, Eureka Tanks are:
- Easy to install.
- Lightweight, hygienic and do not rust or deteriorate
over time.
- Easy to clean.
- They conserve water temperature.
- Resistant, durable, practical and economical.
- Protect water from algae, moss and bacteria.
-Storage tanks on a fl at surface free of objects that could damage
the tank walls or fl oor.
-Stack according to size in no more than two levels, placing the
tanks on the highest level between the two lines below. Do not
stack on top of the lower tank lids.
-Avoid storing tanks on mezzanine edges or places where they can
fall and be knocked over.
-When handling, they should not be thrown from heights, dragged
or knocked against walls or fl oors.
-Protect the connection plans and other components of the system
during handling and storage.
450-1100 liters 2500 liters
CHARACTERISTICS
PRESENTATION
STORAGE AND HANDLING

V. 07-21
www.plycem.com
V. 10-21
www.plycem.com
2INSTALLATION GUIDE FOR EUREKA TANK
Multi connector
valve
Inlet valve
Float
Filter
(120 mesh discs)
Air jug
Ask for available stock.
M-inox Filter
**
Note:
*Ask for the accessories kit content. Filter may be included or optional
depending on country. The type of filter will depend on inventory
availability.
Build a level, fl at base to place your tank on.
To obtain adequate pressure in the distribution line, verify that from
the base of your tank to the highest expected height (faucet or
shower), there is a minimum height of 2 meters as shown.
According to the installation diagram on page 2, we show below
the plastic accessories (PVC) necessary for its correct operation
(not included).
1 1/2” female adapter.
2 reductions from 3/4” to 1/2”.
2 3/4” male adapters.
3 1/2” male adapters.
2 1/2” elbows.
1 1/2” check valve.
1 tee of 1/2”.
1 ball valve of 1/2”.
1/2” pipe.
Connection accessories
Before installing the tank at the installation site, aspects such
as topography, soil types, fl oodable areas, nearby vegetation,
etc., among others, should be reviewed, nearby vegetation,
etc., and others. This is in order to avoid that any of the before
mentioned factors may interfere with the proper functioning
of the system or jeopardize the structural integrity of the tank.
A bad selection of the installation site may cancel the warranty.
Step 1
MEASUREMENTS INSTALLATION INSTRUCTIONS
COMPLEMENTARY ACCESSORIES
2500 1610 1540 10
litros
A
mm
B
mm
250 875 570 1-2
450 905 865 2
750 1100 1300 4
1100 1160 1265 5
41
Capacity
liters
A
mm
B
mm People
-
11
15
19
Weight
Three-layer
(Kg)
Weight
Two-layer(Blue)
(Kg)
29
7
9
11
14.5

V. 07-21
www.plycem.com
V. 10-21
www.plycem.com
3INSTALLATION GUIDE FOR EUREKA TANK
• Make sure the level of the support surface of the tank.
• Make sure that the support surface is larger than the bottom
of the tank.
• Do not place the tank on irregular fl oor.
• Do not place the tank on separate parts or beams.
• Do not install the tank underground.
• Do not place the tank on irregular surfaces, vegetation, roots
or elements that may damage the bottom of the tank.
Installation precaution
◾Tanks should be washed before installation.
◾The tank should be always cleaned every six months. Check the
lter and connections and make the necessary adjustments
and repairs.
◾The tank should be always covered.
◾When using a pumping system, the pipe should be anchored at
the tank inlet to absorb any movement over the tank connector.
◾The system should be installed in an easily accessible location
to allow for inspection and to facilitate proper maintenance.
◾When storing the tank prior to installation, be sure to keep it in an
upright position on a smooth, level surface.
◾The temperature of the liquid to be stored must not exceed 60°
Celsius.
◾For the installation of additional accessories to the tank, it
is important to consult with your distributor warehouse. It is
important that you consult your authorized supplier beforehand.
Installation provisions
Multi connector installation.
Y o u r t a n k ( 1 ) h a s a t h r e a d e d fl a n g e ( 2 ) . S c r e w o n t h e
multi connector (3) with 1/2” or 3/4” outlet. Use the one that
corresponds to the diameter of your distribution pipe (5). Use only
your hands to tighten it. Turn until the threaded plug of the air jug
(4) is facing upwards and the cleaning plug (6) is on one side as
shown in the gure. Remove the plug and insert the air jug tube (4).
Connect the multi-connector (3) to the distribution pipe.
Step 3
1
2
3
4
5
6
Control alternatives (1 and 2) valve and fl oat.
To install the valve and fl oat your tank has a hole (3) in the top neck
to insert the water supply tube (5), at the end of the tube, using a
union (4) (not included). Install the valve and fl oat (1 and 2) as shown.
2. Electronic level (electrode not included). Its new tank has a
special base that allows the placement of an electrode.
Place Tefl on tape (not included) on all pipe threads and ttings to
be installed.
Step 2
12345
Male adapters
1
/
2
”
Float Filter
Multi connector
valve
Tee PVC
1
/
2
”
PVC elbow
1
/
2
”
Shut-o
valve
Water inlet and
outlet
Outlet pipe
support
Connecting
ange
PVC elbow
1
/
2
”
Check
valve
Air jug

V. 07-21
www.plycem.com
V. 10-21
www.plycem.com
4INSTALLATION GUIDE FOR EUREKA TANK
NOTE:
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
_______________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
_______________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
Plycem warrants that if a product of its brand proves to be defective
in materials or in the manufacturing process within 100 years (5 years
for accessories) from the date of manufacture, it will, at its option,
either repair or replace such product. Plycem’s liability is limited solely
to the value of the product and excludes the cost of installation,
removal of damaged product or any consequential damages.
Neither Plycem nor its authorized distributors in Central America
shall be liable for indirect damages or defects caused by an incorrect
installation or by the omission of any of the points described in this
document. Neither does it cover transportation or labor costs that may
be generated by the incorrect application of the installation procedures
indicated.
The factory warranty covers only manufacturing defects. It is not
recommended that a Eureka Tank product be used for any purpose
other than as described in this document. Any other use will void
the Plycem Eureka Tank product warranty either express or implied.
In no event shall Plycem be held liable for consequential damages.
This standard limited warranty does not apply to damages resulting
from misuse, misapplication of recommended materials, accidents,
installation, omission of procedures or improper maintenance.
Warranty
◾Shut o the water supply to the
Eureka tank.
◾Empty your Eureka tank to about
5 cm of water at the bottom.
◾Shut o the water supply to your
house by closing the valve.
◾Wash the inside walls and bottom of
your Eureka tank with a plastic brush
and liquid disinfectant soap.
◾Remove the multi connector
discharge plug, remove all contents
and rinse.
◾Make a nal cleaning of the inside
walls and bottom with a clean, dry
rag or mop.
◾Install the discharge plug on the
multi connector and open the valve
that supplies water to your home.
◾Turn on the water supply to your
Eureka tank, wait for it to ll and it is
ready to use.
Maintenance
1
2
3
4
5
6
7
8

Para mayor información contáctenos a los teléfonos:
www.plycem.com contactoply[email protected]
Find us in:
PLYCEM Construsistemas El Salvador S.A.
PLYCEM Construsistemas Costa Rica S.A.
INTE/ISO 14001:2015
SGA-008/01/2010
SISTEMA DE GESTIÓN
AMBIENTAL
CERTIFICADO
001-CP-2001
PRODUCTO
CERTIFICADO
069-CP-2013
PRODUCTO
CERTIFICADO
INTE/ISO 45001:2018
SST-009/2020
SISTEMA DE GESTIÓN DE
LA SEGURIDAD Y SALUD
EN EL TRABAJO
CERTIFICADO
INTE/ISO 45001:2018
SST-006/2020
SISTEMA DE GESTIÓN DE
LA SEGURIDAD Y SALUD
EN EL TRABAJO
CERTIFICADO
Manufactured by:
Table of contents
Popular Storage manuals by other brands

Seagate
Seagate NAS OS 4 U user manual

Seagate
Seagate Barracuda 36ES2 ST336938LW installation guide

Western Digital
Western Digital WD1600AVBB Specifications

Seagate
Seagate Pipeline HD ST1500VM002 product manual

Hitachi
Hitachi 2.5-INCH Travelstar HTS542525K9A300 datasheet

Transcend
Transcend USB JetFlash user manual