Elumen8 MP60 User manual

MP60 LED Fresnel CW
User Manual
Order codes:
ELUM106 - Black Housing
ELUM106A - White Housing

www.prolight.co.uk MP60 LED Fresnel CW User Manual 2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thislightingxtureisforprofessionaluseonly-itis
notdesignedfororsuitableforhouseholduse.The
productmustbeinstalledbyaqualiedtechnicianin
accordancewithlocalterritoryregulations.Thesafetyof
theinstallationistheresponsibilityoftheinstaller.The
xturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingto
EN62471.Donotviewthelightoutputwithoptical
instrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Twoyearsfromdateofpurchase.

www.prolight.co.uk MP60 LED Fresnel CW User Manual 3
Product overview & technical specications
TheMPLEDFresnelfamilyarecompact,robustandeasytousegeneralpurposestagelightingxturesidealfor
smallstages,studiosanddisplaylightingapplications.Thesexturesprovideasuperblightoutputandbenet
fromtemperaturecontrolledfancoolingforwhisperquietoperation.The4pushbuttondisplayallowsusersto
selectDMXandmanualdimmingmodesalongwithdimmingcurves.
•1x60WcoolwhiteCOBLED(6500K)
•Manuallyadjustablebeamangle:10°-50°
•6930Lux@2m(fullon)
•1.8kHzrefreshrate
•DMXchannels:1or2selectable
•0-100%dimming
•4dimmingcurvesinbothLEDandhalogenproles:
Linear,squarelaw,inversesquarelawandS-curve
•4pushbuttonmenuwithLCDdisplay
•Captivepowerconnection
•3-PinXLRinput/output
•Filterframeandbarndoorsincluded
MP60 LED Fresnel CW
Specications MP60 LED Fresnel
Powerconsumption 70W
Powersupply 100~240V,50/60Hz
Dimensions 250x210x265mm
Weight 3.8kg
Ordercode ELUM106-BlackHousing
ELUM106A-WhiteHousing
0m 2m 3m 4m 5m
10° - Lux
50° - Lux
6930
1290
1m
27700
5170
3075
574
50°
1730
323
1110
207
10°
210mm
250mm
230mm
210mm
350mm
265mm

www.prolight.co.uk MP60 LED Fresnel CW User Manual 4
FUSE:
T1A 250V DMX INPUT DMX OUTPUT
POWER INPUT:
100-240V~50/60Hz
01 05 03 03 0802
09
11
12
08
04
06
07
10
Technical specications
01-Earthpoint
02-LCDdisplay
03-Functionbuttons
04-3-PinDMXinput
05-3-PinDMXoutput
06-Captivepowerconnection
07-FuseT1A250V
08-Adjustablezoomknob
09-Barndoors
10-Filterframe
11-Hangingbracket
12-Hangingbracketadjustableknob
Inthebox:1 x xture
& 1 x user manual

www.prolight.co.uk MP60 LED Fresnel CW User Manual 5
Operating instructions
DMX ADDR
Channel
DMX address setting
DMX ADDR
001
DMX ADDR
512
DMX channel mode
Channel
01
Channel
02
Manual dimming mode
Manual
DIMMER00
Manual
DIMMER99
Manual
DIMMER
DimCurve
Linear
DimCurve
Square
Dimmer curves
DimCurve
S-Curve
DimCurve
INV.Squa
DimCurve
LED/Halogen selection
LampCurv
LED
LampCurv
Halogen
LampCurv
Display timeout on (30 seconds)
Display timeout off
Reset factory settings
Display
ON
Display
OFF
Display
Fixture
Time
Version
Temp
MENU
Default Yes?
Fixture time
Software version
Temperature

www.prolight.co.uk MP60 LED Fresnel CW User Manual 6
DMX mode:
OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestexibilitywhenitcomes
tocustomisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthe
xtureandeachxtureindependently.
ToaccesstheDMXaddressmode,pressthe“MENU”buttononthefrontoftheunittoshow
“DMX ADDR” ontheLCDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttons
tosettherequiredDMXaddress.Pressthe“ENTER”buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
ToaccesstheDMXchannelmode,pressthe“MENU”buttononthefrontoftheunittoshow
“Channel” ontheLCDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonsto
chooseoneofthe1or2DMXchannelmodes.Pressthe“ENTER”buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Operating instructions
Channel Value Function
1 000-255 Masterdimmer(0-100%)
2000-030 LinearLEDdimmingcurve
031-060 LinearHalogendimmingcurve
061-090 SquareLEDdimmingcurve
091-120 SquareHalogendimmingcurve
121-150 InverseSquareLEDdimmingcurve
151-180 InverseSquareHalogendimmingcurve
181-210 S-curveLEDdimmingcurve
211-255 S-curveHalogendimmingcurve
2 channel mode:
Channel Value Function
1 000-255 Masterdimmer(0-100%)
1 channel mode:

www.prolight.co.uk MP60 LED Fresnel CW User Manual 7
Manual dimming mode:
Toaccessthemanualdimmingmode,pressthe“MENU”buttonontherearoftheunittoshow
“Manual”ontheLCDdisplay.Theunitisnowinmanualdimmingmode.Pressthe“ENTER”button
andusethe“UP”and“DOWN”buttonstosetthebrightnessfrom“0” - “99”.
Pressthe“ENTER”buttontoconrmthesetting.
(0 = LED off, 99 = LED at full brightness).
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Dimming curves
Toaccesstheunitsdimmercurves,pressthe“MENU”buttonontherearoftheunittoshow
“DimCurve”ontheLCDdisplay.Pressthe“ENTER”buttonandusethe“UP”and“DOWN”buttons
tosetthedimmingcurverequired.
“Linear”-LELineardimmingcurve
“Square”-LEDSquaredimmingcurve
“INV.Squa”-LEDInverseSquaredimmingcurve
“S-Curve”-LEDS-Curvedimmingcurve
Pressthe“ENTER”buttontoconrmthesetting.
TochoosebetweenHalogenandLEDdimmercurves,pressthe“MENU”buttonontherearoftheunitto
show“LampCurv”ontheLCDdisplay.Pressthe“ENTER”buttonandusethe“UP”and“DOWN”buttons
tosetthedimmingcurvemoderequired.
“LED”-LEDdimmingcurves
“Halogen”-Halogendimmingcurves
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Operating instructions

www.prolight.co.uk MP60 LED Fresnel CW User Manual 8
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk MP60 LED Fresnel CW User Manual 9
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup

www.prolight.co.uk MP60 LED Fresnel CW User Manual 10
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposed
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.

www.prolight.co.uk MP60 LED Fresnel CW User Manual 11

www.prolight.co.uk MP60 LED Fresnel CW User Manual 12
This manual suits for next models