Elumen8 MP75 User manual

MP75 LED Fresnel RGBW
User Manual
Order codes:
ELUM105 - Black Housing
ELUM105A - White Housing

www.prolight.co.uk MP75 LED Fresnel RGBW User Manual 2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Before your initial start-up, please make sure that there is no damage caused during transportation.
• Should there be any damage, consult your dealer and do not use the equipment.
• To maintain the equipment in good working condition and to ensure safe operation, it is necessary
for the user to follow the safety instructions and warning notes written in this manual.
• Please note that damages caused by user modications to this equipment are not subject to warranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Never let the power cable come into contact with other
cables. Handle the power cable and all mains voltage
connections with particular caution!
• Never remove warning or informative labels from the unit.
• Do not open the equipment and do not modify the unit.
• Do not connect this equipment to a dimmer pack.
• Do not switch the equipment on and off in short intervals,
as this will reduce the system’s life.
• Only use the equipment indoors.
• Do not expose to ammable sources, liquids or gases.
• Always disconnect the power from the mains when
equipment is not in use or before cleaning! Only handle
the power-cable by the plug. Never pull out the plug by
pulling the power-cable.
• Make sure that the available mains supply voltage is
between 100~240V AC, 50/60Hz.
• Make sure that the power cable is never crimped or
damaged. Check the equipment and the power cable
periodically.
• If the equipment is dropped or damaged, disconnect the
mains power supply immediately and have a qualied
engineer inspect the equipment before operating again.
• If the equipment has been exposed to drastic
temperature uctuation (e.g. after transportation),
do not connect power or switch it on immediately.
The arising condensation might damage the equipment.
Leave the equipment switched off until it has reached
room temperature.
• If your product fails to function correctly, stop use
immediately. Pack the unit securely (preferably in the
original packing material), and return it to your Pro Light
dealer for service.
• Only use fuses of same type and rating.
• Repairs, servicing and power connection must only be
carried out by a qualied technician. THIS UNIT CONTAINS
NO USER SERVICEABLE PARTS.
• This lighting xture is for professional use only - it is
not designed for or suitable for household use. The
product must be installed by a qualied technician in
accordance with local territory regulations. The safety of
the installation is the responsibility of the installer. The
xture presents risks of severe injury or death due to re
hazards, electric shock and falls.
• Warning! Risk Group 2 LED product according to
EN 62471. Do not view the light output with optical
instruments or any device that may concentrate the beam.
• WARRANTY: Two years from date of purchase.

www.prolight.co.uk MP75 LED Fresnel RGBW User Manual 3
Product overview & technical specications
The MP LED Fresnel family are compact, robust and easy to use general purpose stage lighting xtures ideal for
small stages, studios and display lighting applications. These xtures provide a superb light output and benet
from temperature controlled fan cooling for whisper quiet operation. The 4 push button display allows users to
select DMX and manual dimming modes along with dimming curves.
• 1 x 75W quad-colour COB LED (RGBW)
• Manually adjustable beam angle: 10°- 50°
• 6031 Lux @ 2m (full on)
• 1.8kHz refresh rate
• DMX channels: 4/5 or 7 selectable
• 0-100% dimming
• 4 dimming curves in both LED and halogen proles:
Linear, square law, inverse square law and S-curve
• 4 push button menu with LCD display
• Captive power connection
• 3-Pin XLR input/output
• Filter frame and barn doors included
MP75 LED Fresnel RGBW
Specications MP75 LED Fresnel
Power consumption 86W
Power supply 100~240V, 50/60Hz
Dimensions 250 x 210 x 265mm
Weight 3.8kg
Order code ELUM105 - Black Housing
ELUM105A - White Housing
0m 2m 3m 4m 5m1m
50°
10°
10° - Lux
R
G
B
W
FULL ON
50° - Lux
R
G
B
W
FULL ON
4400
7640
1650
10800
24100
500
816
160
1110
2520
1104
1912
412
2694
6031
125
204
40
277
630
489
849
183
1200
2680
55
90
17
123
280
275
478
103
673
1510
31
51
10
69
158
176
306
65
430
965
20
32
6
44
101
210mm
250mm
230mm
210mm
350mm
265mm

www.prolight.co.uk MP75 LED Fresnel RGBW User Manual 4
FUSE:
T1A 250V DMX INPUT DMX OUTPUT
POWER INPUT:
100-240V~50/60Hz
01 05 03 03 0802
09
11
12
08
04
06
07
10
Technical specications
01 - Earth point
02 - LCD display
03 - Function buttons
04 - 3-Pin DMX input
05 - 3-Pin DMX output
06 - Captive power connection
07 - Fuse T1A 250V
08 - Adjustable zoom knob
09 - Barn doors
10 - Filter frame
11 - Hanging bracket
12 - Hanging bracket adjustable knob
In the box: 1 x xture
& 1 x user manual

www.prolight.co.uk MP75 LED Fresnel RGBW User Manual 5
Operating instructions
MENU
DMX ADDR DMX address setting
DMX ADDR
001
DMX ADDR
512
DMX channel mode
Channel Channel
05
Channel
04
Channel
07
Manual dimming mode
Manual
R00 G00
Manual
B00 W00
Manual
R99 G99
Manual
B99 W99
Manual
DIMMER
Sound sensitivity
Sound
00
Sound
31
Sound
DimCurve
Linear
DimCurve
Square
Dimmer curves
DimCurve
S-Curve
DimCurve
INV.Squa
DimCurve
Built-in programs
SPEED:00
SPEED:99
1.STATIC
2.CHANGE
4.AUTO
3.FADE
LED/Halogen selection
LampCurv
LED
LampCurv
Halogen
LampCurv

www.prolight.co.uk MP75 LED Fresnel RGBW User Manual 6
Operating instructions
MENU
CONT.
Display timeout on (30 seconds)
Display timeout off
Display
ON
Display
OFF
Display
Reset factory settings
Default Yes?
Fixture
Time Fixture Time
Temp Temperature
Version Software version

www.prolight.co.uk MP75 LED Fresnel RGBW User Manual 7
DMX mode:
Operating in a DMX control mode environment gives the user the greatest exibility when it comes
to customising or creating a show. In this mode you will be able to control each individual trait of the
xture and each xture independently.
To access the DMX address mode, press the “MENU” button on the front of the unit to show
“DMX ADDR” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons
to set the required DMX address. Press the “ENTER” button to conrm the setting.
To exit out of any of the above options, press the “MENU” button.
To access the DMX channel mode, press the “MENU” button on the front of the unit to show
“Channel” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to
choose one of the 4/5 or 7 DMX channel modes. Press the “ENTER” button to conrm the setting.
To exit out of any of the above options, press the “MENU” button.
Channel Value Function
1 000-100 Colour change (slow-fast)
101-200 Colour fade (slow-fast)
201-255 Sound active (sensitivity low-high)
2 000-255 Red (0-100%)
3 000-255 Green (0-100%)
4 000-255 Blue (0-100%)
5 000-255 White (0-100%)
6 000-030 Linear LED dimming curve
031-060 Linear Halogen dimming curve
061-090 Square LED dimming curve
091-120 Square Halogen dimming curve
121-150 Inverse Square LED dimming curve
151-180 Inverse Square Halogen dimming curve
181-210 S-curve LED dimming curve
211-255 S-curve Halogen dimming curve
7 000-255 Master dimmer (0-100%)
7 channel mode:
Channel Value Function
1 000-255 Red (0-100%)
2 000-255 Green (0-100%)
3 000-255 Blue (0-100%)
4 000-255 White (0-100%)
4 channel mode:
Channel Value Function
1 000-255 Red (0-100%)
2 000-255 Green (0-100%)
3 000-255 Blue (0-100%)
4 000-255 White (0-100%)
5 000-255 Master dimmer (0-100%)
5 channel mode:
Operating instructions

www.prolight.co.uk MP75 LED Fresnel RGBW User Manual 8
Built-in programs:
To access the built-in program, press the “MENU” button to show “01.STATIC” on the LCD display.
Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose one of the
4 built-in programs (01-04) (see table overleaf).
To choose one of the 15 colours in the “STATIC” mode, press the press the “ENTER” button and use
the “UP” and “DOWN” buttons to choose one of the following 15 colours.
To adjust the speed level in the remaining 3 built-in programs, press the “ENTER” button and use
the “UP” and “DOWN” buttons to set the desired speed level (00-99). Press the “ENTER” button to
conrm your setting.
To exit out of any of the above options, press the “MENU” button.
Sound active mode:
To select the sound active mode, press the “MODE” button to show “Sound” on the LCD display. Now
press the “ENTER” button and use the “UP” and “DOWN” buttons to adjust the sound
sensitivity level (00-31). Press the “ENTER” button to conrm your setting.
(01 = low sensitivity, 31 = high sensitivity).
To exit out of any of the above options, press the “MODE” button.
Manual dimming mode:
To access the manual dimming mode, press the “MENU” button on the rear of the unit to show
“Manual” on the LCD display. The unit is now in manual dimming mode. Press the “ENTER” button and
use the “UP” and “DOWN” buttons to set the brightness of “R” from “0” - “99”. Repeat for “G”, “B” and
“W”. Press the “ENTER” button to conrm the setting.
(0 = LED off, 99 = LED at full brightness).
To exit out of any of the above options, press the “MENU” button.
Built-in programs:
Value Function
Static colour
CL: BLAC-RGBW
Blackout, Red, Green, Yellow, Blue, Magenta, Cyan, White (RGB), White (W), Pastel Red,
Pastel Green, Warm white, Pastel Blue, Pastel Magenta, Pastel Cyan, White (RGBW)
Colour change
Speed: 00-99
15 colour change
Speed ajustable
Fade
Speed: 00-99
15 colour fade
Speed ajustable
Auto
Speed: 00-99
15 colour change & fade
Speed ajustable
Operating instructions

www.prolight.co.uk MP75 LED Fresnel RGBW User Manual 9
Operating instructions
Dimming curves
To access the units dimmer curves, press the “MENU” button on the rear of the unit to show
“DimCurve” on the LCD display. Press the “ENTER” button and use the “UP” and “DOWN” buttons
to set the dimming curve required.
“Linear” - LELinear dimming curve
“Square” - LED Square dimming curve
“INV.Squa” - LED Inverse Square dimming curve
“S-Curve” - LED S-Curve dimming curve
Press the “ENTER” button to conrm the setting.
To choose between Halogen and LED dimmer curves, press the “MENU” button on the rear of the unit to
show “LampCurv” on the LCD display. Press the “ENTER” button and use the “UP” and “DOWN” buttons
to set the dimming curve mode required.
“LED” - LED dimming curves
“Halogen” - Halogen dimming curves
To exit out of any of the above options, press the “MENU” button.

www.prolight.co.uk MP75 LED Fresnel RGBW User Manual 10
Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each xture requires a “start address”
from 1- 511. A xture requiring one or more channels for control begins to read the data on the channel
indicated by the start address. For example, a xture that occupies or uses 7 channels of DMX and was
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the
chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent
xtures and controllers. A DMX controller sends DMX data instructions form the controller to the xture.
DMX data is sent as serial data that travels from xture to xture via the DATA “IN” and DATA “OUT”
XLR terminals located on all DMX xtures (most controllers only have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to be linked together
and operate from a single controller, as long as all xtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX xtures try to use the shortest
cable path possible. The order in which xtures are connected in a DMX line does not inuence the
DMX addressing. For example; a xture assigned to a DMX address of 1 may be placed anywhere in
a DMX line, at the beginning, at the end, or anywhere in the middle. When a xture is assigned a
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,
no matter where it is located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation):
This xture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit.
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,
see image below.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
Further DMX cables can be
purchased from all good sound
and lighting suppliers or
Pro Light Concepts dealers.
Please quote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk MP75 LED Fresnel RGBW User Manual 11
Notice:
Be sure to follow the diagrams below when making your own cables. Do not connect the cables
shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs
outer casing. Grounding the shield could cause a short circuit and erratic behaviour.
Special note:
Line termination:
When longer runs of cable are used,
you may need to use a terminator on
the last unit to avoid erratic behaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR xtures
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.
Termination reduces signal transmission
problems and interference. It is always
advisable to connect a DMX terminal,
(resistance 120 Ohm 1/4 W) between pin 2
(DMX-) and pin 3 (DMX+) of the last xture.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup

www.prolight.co.uk MP75 LED Fresnel RGBW User Manual 12
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed
with other household wastes at the end of its working life. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, please separate this from other
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their
local government ofce, for details of where and how they can take this item for environmentally
safe recycling.
Business users should contact their supplier and check the terms and conditions of the
purchase contract. This product should not be mixed with other commercial wastes for disposal.
This manual suits for next models
1
Table of contents
Other Elumen8 Studio Light manuals