Enginuity OnSite WR-15U User manual

WR-15U Aug2017
001-01-000091 Rev.000
OnSite™is a trademark ofEnginuity Communications, Inc. ©2017 EnginuityCommunications Corporation Page1 of 6
OnSite™19”/15U Wall Rack
Model WR-15U
1. OVERVIEW................................................................. 1
2. APPLICATIONS......................................................... 1
3. DESCRIPTION........................................................... 2
4. INSTALLATION.......................................................... 2
5. TESTING AND TROUBLESHOOTING ................... 5
6. CUSTOMER SERVICE............................................. 5
7. WARRANTY & REPAIRS.......................................... 5
8. SPECIFICATIONS..................................................... 6
1. OVERVIEW
Enginuity’s OnSite™ ModelWR-15U (Figures 1 and 2) is
a wall-mounted equipment rack that supports up to fifteen
19-inch rack units (15U) in a compact footprint. Cable
management options include side-mounted guides for
cable grooming and take-up reelsfor cable slack. The
carrier-class assembly is an ideal fit for equipment rooms,
cabinets, or customer premises locations.
Document Status
This is the initial release of this technical publication.
Product Features
•15U height for 19-inch rack-mounted equipment
•Easily installed on a wall or backboard
•Welded, carrier-class design
•Optional side-mounted cable guides and take-up reels
•Reduces wall space requirements for multi-chassis
applications
2. APPLICATIONS
For service delivery, the WR-15U allows carriers to
securelywall mount rack-based equipment in equipment
rooms, cabinets, or on customer premises. The WR-15U
offers the following technician-friendly solutions:
Rack-Mount Compatibility
The WR-15U supports any combination of standard 19-
inch rack-based equipment, up to a total of fifteen rack
units high. The mounting arrangement provides the
densitybenefitsof a floor rack, but in a compact wall-
mounted footprint that requires only a single technician to
install.
Figure 1. WR-15U Wall Rack
Figure 2. WR-15U w/ equipment installed (example)

001-01-000091 Rev. 000 Page2 of6
Cable Management
Cable guidescan be installed on either side of the WR-
15U to groom cablesfrom thefront of each equipment
chassis back to thewall. A package of fivecable guides is
available as Model CG-5.
Side plates with cable take-up reels can be addedto
store excesscable lengthbeing fed to installed
equipment. Model SPL-4H mounts to either side of the
WR-15U and includestwo adjustable, split reels.
3. DESCRIPTION
The WR-15U (Figure 3) features welded steel, carrier-
class construction. The front of the frame provides two
vertical railswith standard threaded hole spacing for up to
fifteen rack units. Ten pairs of threaded grounding holes
and pre-installed screws are provided on the rear
crossbar for attachment of ground lugs. One pair of holes
supports grounding of the WR-15U itself and the other
nine pairs of holes supportground connections from
installedequipment. The unpainted grounding area
provides metal-to-metal contact with ground lug surfaces.
Cable Guides
Optional cable guides with removable covers (Figure 4)
can be attached to either side of the WR-15U frame. Up
to fifteen cable guides can be installed per side.
Side Plate with Take-up Reels
Anoptional side plate, Model SPL-4H (Figure 5), provides
two adjustable cable take-up reels. The reels are sized to
maintain proper bend radius infiber applications. One or
two platescanbe attached to either side of the WR-15U
frame using the included hardware.
4. INSTALLATION
The WR-15U shipping carton contains the following:
•Pre-assembled mounting frame
•Ten (10) #12 x 1” slotted hex screws, self-tapping
•Product documentation
Installation stepsare described indetail below.
A. Mounting frame
Selectan appropriate location on awall or backboard
to installthe mountingframe.Choose a mounting
surface and hardware that can support the combined
weight of the mounting assembly and equipment that
isto be installed. Mounting to a 3/4” thick backboard
with #12 x 1” screws is recommended. Maximum
weight holding capacity of the WR-15U is 200 lbs.
Determine the desired orientation of the ground lugs.
The symmetrical design of the WR-15U frame allows it
to be installed with the grounding holes facing upward
or downward.
Figure 3. WR-15U Features
Figure 4. Cable guide
Figure 5. Model SPL-4H Side Plate
Slide on/off cover
Threaded
grounding holes
Standard threaded hole
spacingfor upto 15 rack units

001-01-000091 Rev. 000 Page3 of6
Hold the emptymounting frame firmly against the wall
or backboard in a level position and mark screw
locations for each of the eight mounting brackets
located at the rear of the frame. Theframewill be
fastened with two screws in the topmost bracket on
each side and one screw in each of the other
brackets, as shown in Figure 6.
Remove the mounting frame from the wall and drill
pilot holes for each of the marked screw locations.
Before attempting to fasten the mounting frame to the
wall, insert a screw into the top pilot hole oneitherthe
left or right side. Partially thread the screw into the
hole, leaving the screw head approximately 1/4” from
the surface.
Hold themounting frame against the wall whileresting
the cutout of the bracket onthe installed screw.Align
the other nine mounting holes and install a screw in
each hole. Tighten all ten (10) screws securely.
B. Frame grounding
Locate the ten (10) pairs of pre-installed grounding
screws with lock washers on the crossbar of the
frame. The grounding screws are 10-32 x 3/8” on 5/8”
centers.
Install a dualground lug (customer provided) with
holes on 5/8” centers beneath the included screws
and washers onone pair of grounding holes. Tighten
the screws to fasten the lug to the mounting frame.
The example in Figure 7 illustrates the frame
positioned with grounding screws facing downward.
Connect a ground wire of appropriate gauge to the
ground lug, and attach the other end of the wire to a
bonded ground point, per local procedures for network
equipment.
C. Equipment Installation
Install rack equipment with 19” hole spacing by
carefully sliding the chassis through the front of the
WR-15U and aligning chassis mounting ears with the
threaded holes in the rails of theWR-15U frame.
Insert and tighten #12-24 machine screws (customer
provided)on each side of the chassis. An example of
a fully populated wall rack is shown in Figure 2.
Attach ground lugs associated with eachequipment
chassis to the threaded ground holes on the WR-15U
crossbar as needed.
D. Optional Cable Guide Installation
To install a cable guide to the side of the mounting,
first remove the sliding cover from the cable guide.
Insert two of the #10-32 x 3/8” screws (included in
CG-5 package)through the cableguide and into the
threaded holes onthe side of the WR-15U frame
(Figure 8).
Groom cabling from the frontof the chassisto the wall
through the cable guide on the side of the WR-15U, as
shown in Figure 9, and replace the sliding cover.
Figure 6. Mounting screw locations
Figure 7. Frame grounding example

001-01-000091 Rev. 000 Page4 of6
E. Optional Side Plate Installation
One or two side plates (Model SPL-4H) can be installed
on either side of the WR-15U chassis for cable slack
management. The SPL-4H provides two split and
adjustable take-up reels, as illustrated inFigure 5.
To install and use the SPL-4H side plate, refer to Figure
10 andthe steps below.
Slide the two narrower tabs at the edge of the SPL-4H
into the openings onthe side of the WR-15U, toward
the rear of the mounting.
Align the wide tabs at the front edge of the SPL-4H
with the threaded holeson the side of theWR-15U
frame. Use the two (2) included #10-32 x 3/8” screws
to securely fasten the side plate to theframe.
Carefully wrap cables around the take-up reels to
reduce slack as needed. Example routing is shown in
Figure11. Alternate mounting holesare included on
the side plate for repositioning the half-reels, if desired.
Figure 8. Cable guide installation
Figure 9. Cable guide application
Figure 10. SPL-4H installation

001-01-000091 Rev. 000 Page5 of6
5. TESTING AND TROUBLESHOOTING
Each piece of equipment installed inthe WR-15U should
be tested according the manufacturer’s instructions.
6. CUSTOMER SERVICE
Customer Sales and General Support
Monday through Friday, 8:00 a.m. –5:00 p.m. CST
Toll Free: 800-980-ECOM (3266), Local: 630-444-0778
24/7 SalesSupport: sales@enginuitycom.com
24/7 Technical Support:
Toll Free: 800-841-1005
E-mail: support@enginuitycom.com
Enginuity Communications
3545 Stern Avenue
St. Charles, IL 60174
7. WARRANTY & REPAIRS
Warranty
Enginuity warrants this product for one (1) year from date
of purchase. Any attempt to repair or modify the
equipment by anyone other than an authorized Enginuity
representative willvoid thewarranty.
This limited warrantydoes not cover any losses or
damages resulting from shipment to or from the
customer, or from improper installation, abuse,
modifications, or unauthorized repair by other than
Enginuity personnel.
Repair and Return
Enginuityequipment will be repaired or replaced without
cost during the warranty period if the product is defective
for any reasonother than abuse, improper use, or
improper installation. Before returning defective
equipment, first request a Return Material Authorization
(RMA) numberfrom Enginuity.Once an RMA number is
obtained, return the unit, freightprepaid, along witha brief
description of the problem, to:
Enginuity Communications
3545 Stern Avenue
St. Charles, Illinois 60174
ATTN: Repair & ReturnDept.
Replacementswill be shipped in the fastest manner
consistent withthe urgency of the situation.Repair or
replacement of faulty equipment beyond the warranty
period is availablefor a nominal charge.
Figure 11. Cable take-up reel routing

001-01-000091 Rev. 000 Page6 of6
8. SPECIFICATIONS
Mounting Frame
Part Number
WR-15U
Description
OnSite™ 19”/15U wall rack
Height
28.0 inches
Width
22.7 inches
Depth
12.6 inches
Weight
18.0 pounds
Capacity
15 rack units, total installed equipment weight not to exceed 200 lbs.
Operating Temperature
0 to 50C
Standards Compliance
Meets applicable Telcordia NEBS requirements, including Zone 4 seismic.
Optional Side Plate
Part Number
SPL-4H
Description
Side plate for wall rack with (2) adjustable take-up reels
Height
10.5 inches
Width
11.3 inches
Depth
1.3 inches
Weight
2.5 pounds
Additional Cable Guides
Part Number
CG-5
Description
Pack of (5) cable guides for wall rack
Height
1.0 inches (each)
Width
1.3 inches (each)
Depth
7.8 inches (each)
Weight
2.0 ounces (each)
Table of contents
Other Enginuity Rack & Stand manuals
Popular Rack & Stand manuals by other brands

Roland
Roland V-Drums MDS-9 owner's manual

clage
clage RDX 3 Installing instructions for the professional

Clas Ohlson
Clas Ohlson 40-6814 quick start guide

Crestron
Crestron CPC-WMT Operations & installation guide

CONEN
CONEN LITE Series Assembly instruction

Testrite Visual
Testrite Visual Skyscraper Mightee Mount SKMM Series manual

Ergotron
Ergotron DM32-1016-1 user guide

Abtus
Abtus AV-891-610 User's operation guide

Rothenberger
Rothenberger RODIACUT 400 PRO Instructions for use

Code 3
Code 3 C3900 Installation and operation instructions

StarTech.com
StarTech.com ARMDUOSS user manual

Tektronix
Tektronix TTR500RACK installation instructions