INSTRUCTIONS
BT46SK 12 VOLT KIT - MANUAL NOZZLE
BT46SKA 12 VOLT KIT - AUTO NOZZLE
WARRANTY
1. This pump has a WARRANTY of 12 months from date of purchase
covering faulty workmanship or materials within the
product.
2. Warranty is limited to the repair or replacement of the faulty part as
instructed by the manufacturer.
3. The warranty does not cover: Inadequate or improper use, negligence,
abuse, alteration or the wrong installation of the product, use of non-
original spare parts or normal wear from use.
4. Equipment must be sent freight paid to factory or designated
service centre for evaluation.
SAFETY
These instructions are a guide only and do not override any local regulations
or safety guides.
Take all necessary precautions when using this equipment and wear
appropriate safety wear. Gloves and Safety Glasses are recommended.
The manufacturer reserves the right to update its products and instructions
manuals due to product development or change.
All dimensions and Specifications are approximate and descriptive only and
are subject to alterations without notice.
POWER CABLE ALTERATION—CONNECTION
If you require longer power cable than standard, cable with minimum cross
section as shown in table must be used. Ensure all connections are
soldered. Ensure battery has sufficient capacity to maintain current required
for pump. IMPORTANT— If these instructions aren't adhered to pump
failure may result and warranty will be void.
CABLE LENGTH CABLE SECTION
2m 2.5mm²
4m 6mm²
6m 10mm²
OPTIONS:
Automatic nozzle
Fuel Filter
Fuel Meter
QUALITY 12 VOLT POWERED DIESEL TRANSFER PUMP
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERNCE
BT46 12 VOLT FUEL PUMP KITS
Thank you for your purchase of your Equipco Diesel Transfer pump.
EQUIPMENT DESCRIPTION
The pump is a safe priming rotating vane type equipped with integral by-pass valve
and is positive-displacement in function. The 12 volt DC motor is a sealed
non-ventilated type with 30 minute duty cycle.
INSTALLATION INSTRUCTIONS
The unit is designed for mounting direct to a tank or drum, as a
manual carry pump or installed as part of equipment.
1. Carefully clean inlet and outlet ports and remove dust and residual packing
material.
2. Standard Vertical Kit: Please ensure pump is mounted horizontally. Screw
suction pipe assembly on to pump, seal with thread tape or similar and tighten
securely. Fit hose to pump horizontal outlet and attach hose to nozzle con-
nection. Ensure all connections are leak proof and tight. Cut suction pipe to
correct depth and mount drum connector to
suction point. Carefully check that thread is not crossed and tighten screw
connections
3. Take care with suction and delivery pipework to avoid stress transmitted by
pipes to the pump ports. Be sure suction strainer is fitted to protect pump or
accessories and remove all threading residual material and scale from
storage tank and pipes.
4. In the case of mobile storage tanks, ensure baffle is fitted to protect suction
pipe from surge damage.
5. Before connecting delivery piping or hose, partially fill pump casing with diesel
to facilitate first priming.
6. Refer to back page for power cable alterations.
7. Risks due to extreme temperature. Remember that a very low temperature
(-10°C) can freeze the Diesel oil inside the pump. This situation can cause
serious damage to the motor pump unit. A very high temperature
(above 45°C) may cause the plastic parts in the unit to expand. The unit
should be placed in a well ventilated place and protected from the sun. Also
the pump unit should be protected from rain and the possibility of water
damage.
NOTE: A suction strainer must be fitted to protect pump from possible damage.
Failure to do this will void warranty claims.
TROUBLE SHOOTING GUIDE
Motor does not run
No
or
low Pump Delivery
Motor stops or has burning smell
POSSIBLE CAUSES CORRECTIVE ACTION
1. No electrical power Check supply current, connections and fuses
2. Blocked rotor Remove pump cover and check for obstructions
3. Motor failure Contact repair centre
POSSIBLE CAUSES CORRECTIVE ACTION
Problem in suction pipe Check for blockage or air leaks
Opened by-pass valve Remove and check for obstructions
Blocked hose or nozzle Check pump outlet, hose and nozzle
Vanes worn Remove pump cover and replace vanes
Clogged strainer Clean strainer in suction pipe and internal pump
Excessive suction head Lower pump level Max 4.5 Metre
Low pressure in system Use shorter pipes or with larger diameter
Automatic nozzle option Install foot valve to correct priming problem
POSSIBLE CAUSES CORRECTIVE ACTION
Low voltage current Verify inlet voltage
Blockage inside pump Disassemble and clean the pump
Motor failure Contact repair centre
POSSIBLE CAUSES CORRECTIVE ACTION
Narrow Suction / Delivery hose Increase size of hose or pipe
Blocked filter Remove and clean filter
Pumping of oils Pump must only be used with diesel fuel
Motor breakdown Contact repair centre
POSSIBLE CAUSES CORRECTIVE ACTION
Connections Loose Verify all connections are sealed
Pump seal failure Replace seal
MAINTENANCE
Your pump has been designed and built to require minimum
maintenance. Check the pump casing and pipe joints frequently for
leaks. Keep pump and unit clean and shelter from adverse weather
conditions. Every 3 months check and clean the suction strainer as
necessary.
IT IS THE IN- STALLERS RE-
SPONSIBILITY TO CONNECT THE UNIT USING PIPEWORK OR
HOSE APPROVED FOR USE WITH DIESEL FUEL.
MAKE SURE ANY ADDITIONAL ACCESSORIES SUCH AS
DELIVERY FILTERS OR FILLING DEVICES ETC., ARE SUITABLE
FOR USE WITH FUEL TRANSFER.
For vertical suction length over 2 Metres a foot valve with filter is
required to ensure priming function.
For suction lengths over 2.7 Metres or a horizontal suction length over
4.5 Metres use a pipe for hose with minimum 1” (25mm) bore.
TECHNICAL FEATURES
-BT46 Pump of grey foundry cast iron
Self suction. Eccentric with a auto adjustable vanes
-Flow 40 LPM max
-With recirculation by-pass valve
-Motor: 140 watt 12 volt 140 watt 24 volt
-By-pass pressure: 1.5-1.9 bar
-Consumption: 18-24A (12DC) - 9-17A (24VDC)
-RPM 4200 RPM
-Inlet/Outlet Pipe: 1” Gas (BSP)
-IP-55 Protection
-With clamps for the connection to battery 12 or 24VDC
-NOTE: When you use an automatic nozzle, the flow shall be reduced.
ATTENTION
KIT CONTENTS
BT46
Composed of:
- BT46 12 / 24 Volt pump only
- Cable, clamps and fuse
OPTIONS
Automatic Nozzle
Filter
Flow Meter
BT46M
Composed of:
- BT46 Pump
- 4 Mtrs rubber hose
- Manual nozzle
BT46SK / BT46SKA (Please ensure pump is mounted
horizontally)
Composed of:
- BT46 Pump
- 4 Mtrs rubber hose
- Manual or auto nozzle with swivel
- 2 piece poly suction pipe with socket
- Rotating drum / tank connector
- Lockable nozzle holster
ELECTRICAL CONNECTIONS
The motor is supplies with a 2 Mtr long power cable with clamps for
Connection to the battery.
Red—Positive Pole (+) Black—Negative Pole (-)
Ensure correct voltage battery is being used to power unit. Maximum variation allowed
for voltage is ±5% of rated value. A start-stop switch is standard with a rated fuse for
motor protection.
30 Amp fuse—12 volt 15 Amp fuse—24 volt
It is the installers responsibility to make the electrical installation in accordance
with the applicable local codes and safety regulations.
START UP AND OPERATION
Ensure that amount of Diesel in suction tank is greater than amount to be pumped.
Never run the pump dry as serious damage could result and void the warranty.
(1) Check voltage of power source is same as that of the pump.
(2) Always connect rod terminal to + pole. Black terminal to - pole
(3) Never touch different polarity terminals together as a spark may occur causing a
fire or explosion. Damage to pump motor also may occur.
(4) Take the nozzle out from the holder checking it is closed.
(5) Operate the starting switch. The bypass allows the pump to operate with a
closed nozzle for short periods of time. 30 seconds maximum.
(6) Insert the nozzle into container or tank to be fitted.
(7) Holding the nozzle firmly, operate the lever to dispense fuel.
(8) Release nozzle lever to stop dispensing.
(9) Switch the pump off and put nozzle back in the holder.
Pump duty cycle is for 30 minutes maximum. This
means that pump must be allowed to cool for at least 30
minutes before using again. Failure to follow this direction could cause motor failure.
ATTENTION
In hot weather it is recommended to open the nozzle once the pump is stopped to
release stored pressure.
Likewise in extreme cold temperatures drain the hose and nozzle when not in use.
Failure to do this could cause overpressure due to expansion and damage the pump.
WARNING
This pump is for use with Diesel Fuel only.
Do not use for transfer of petrol, petroleum products or any other fluid with a
flash point below 55° C (130° F).
The motor is not of explosion proof type.
BT46 PARTS BREAKDOWN
POSITION DESCRIPTIONITEM CODE QTY
1ZINC PLATED SCREW CHC M5x8140758 3
2BYPASS KIT142078 1
4KIT VANES142081 5
5ZINC PLATED THREADED ROD M5 L.135140836 2
6ZINC PLATED NUT M5140879 2
7ZINC PLATED SCREW CHC M5x50140764 2
8ON/OFF SWITCH 12V 30A140409 1
9CABLE GLAND M20x1.5140295 1
10 SWITCH CAP 12V141531 1
11 CABLE WITH CLAMPS LG4M 2x2.5mm²140227 1
12 MOTOR 12 V 5000T 140 W141672 1
12 141673 MOTOR 24 V 5000T 140 W 1
13 PUMP BODY 12/24V-40L141389 1
14 PUMP ROTOR 141827 1
15 STEEL COVER141456 1
19 SHAFT KEY 3X3X10141570 1
20 MINI FORK FUSE 30A 12 VOLT140356 1
20 140357 MINI FORK FUSE 15A 24 VOLT 1
21 SEAL KIT142082 1
22 142083 FACE O-RING KIT 3
IMPORTANT

This manual suits for next models

1

Popular Water Pump manuals by other brands

Alcatel Vacuum Technology ATP 100 Service manual & troubleshooting guide

Alcatel Vacuum Technology

Alcatel Vacuum Technology ATP 100 Service manual & troubleshooting guide

GÜDE JA 200 T 400 V Operation manual

GÜDE

GÜDE JA 200 T 400 V Operation manual

Holmatro AHS 1400 FDU manual

Holmatro

Holmatro AHS 1400 FDU manual

GORMAN-RUPP 80 SERIES Installation, operation and maintenance manual

GORMAN-RUPP

GORMAN-RUPP 80 SERIES Installation, operation and maintenance manual

KIRLOSKAR RKB Instruction on installation, operation and maintenance

KIRLOSKAR

KIRLOSKAR RKB Instruction on installation, operation and maintenance

Wilo WILO-SCP Installation and operating instructions

Wilo

Wilo WILO-SCP Installation and operating instructions

Pentair Myers AWS-1 Installation and service manual

Pentair

Pentair Myers AWS-1 Installation and service manual

Kärcher SCP 16000 LEVEL SENSOR manual

Kärcher

Kärcher SCP 16000 LEVEL SENSOR manual

Carlisle Binks E2-15 Service manual

Carlisle

Carlisle Binks E2-15 Service manual

Tuthill FILL-RITE 700V Series Owners installation, operation, and safety manual

Tuthill

Tuthill FILL-RITE 700V Series Owners installation, operation, and safety manual

Levitronix BPS-200 user manual

Levitronix

Levitronix BPS-200 user manual

Lincoln industrial FlowMaster A Series manual

Lincoln industrial

Lincoln industrial FlowMaster A Series manual

Lowara SV-B Installation, operation and maintenance manual

Lowara

Lowara SV-B Installation, operation and maintenance manual

ITC DOSmart AC manual

ITC

ITC DOSmart AC manual

PRAKASH SP-R5A-8 Installation, maintenance and operation manual

PRAKASH

PRAKASH SP-R5A-8 Installation, maintenance and operation manual

Salamander Pumps AccuBoost Series Installation and warranty guide

Salamander Pumps

Salamander Pumps AccuBoost Series Installation and warranty guide

Tuthill M-D Pneumatics PD Plus operating manual

Tuthill

Tuthill M-D Pneumatics PD Plus operating manual

Pentair Hydromatic S4L Installation and service manual

Pentair

Pentair Hydromatic S4L Installation and service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.