Estun TRIO UNIPLAY 7-A User manual


About this Manual
Purpose
This manual provides the information required for the Selection, Wiring, Connection, Setup, Trial
Operation and Functions of the Uniplay 7-A and Uniplay 10-A HMI.
Please read and understand this manual to ensure correct usage of the product.
Terms
Terms that may be used in this manual are defined as follows.
Term
Meaning
HMI
Human Machine Interface
Motion Perfect
The PC Tool for commissioning and programming the Trio product suite.

Symbols
The symbols that may be found in this document are defined as follows.
Symbol
Description
DANGER
Indicates a hazard with a high level of risk that, if not avoided, may result in death or
serious injury.
WARNING
Indicates a hazard with a medium or low level of risk which, if not avoided, could result in
minor or moderate injury.
CAUTION
Indicates a potentially hazardous situation that, if not avoided, could cause equipment
damage, loss of data, performance degradation, or unexpected results.
IMPORTANT
Indicates precautions or restrictions that must be observed.
Also indicates alarm displays and other precautions that will not result in machine damage.
NOTE
Provides additional information to emphasize or supplement important points of the main
text.

Safety Warning
WARNING
During the installation or use of a control system, users of Trio products must ensure
there is no possibility of injury to any person, or damage to machinery. Control systems,
especially during installation, can malfunction or behave unexpectedly. Users must
ensure that in all cases of normal operation, controller malfunction, or unexpected
behaviour, the safety of operators, programmers or any other person is totally ensured.

Contents
Chapter 1 UNIPLAY HMI...........................................................................1-6
1.1 Product Features ........................................................................................1-6
1.2 Specification Table......................................................................................1-6
1.3 Dimensions ...............................................................................................1-8
1.4 System Configuration...................................................................................1-9
Chapter 2 Installation .......................................................................... 2-10
2.1 Environmental considerations....................................................................... 2-10
2.2 Cabinet Installation................................................................................... 2-10
Chapter 3 Wiring and Connections........................................................... 3-12
3.1 Connectors ............................................................................................. 3-12
Chapter 4 Operation ............................................................................ 4-14
4.1 Motion Perfect......................................................................................... 4-14
4.2 Initial Setup ............................................................................................ 4-14
4.3 Running ................................................................................................. 4-16
4.4 Creating an HMI Design............................................................................... 4-17
4.5 Uniplay Simulator ..................................................................................... 4-25
Chapter 5 Revision History .................................................................... 5-27

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
1-6
Chapter 1 UNIPLAY HMI
1.1 Product Features
Trio's unique UNIPLAY HMI system is a revolutionary way to make operator interfaces better, easier and
more secure.
Uniplay HMI is a whole new way of creating and storing HMI screens. HMI screens can be created and
linked to programs directly inside Motion Perfect. The HMI screens are stored with and loaded with the
machine project on the Motion Coordinator.
•Single Point HMI Programming Inside Motion Perfect v5 and above
•Centralised Program / HMI screen Storage in a Motion Perfect Project
•Easily Display any Controller Data Type and Graphics
•No Need to Separately Program HMI Panel
•7” and 10” UNIPLAY Sealed Touch Panels Available
•Connect up to 2 HMI's to your Motion Coordinator
•Ethernet Connection Reduces Wiring
•Simulator built into Motion Perfect
The Uniplay device is a high-quality, high reliability and cost-effective touch screen with an industrial ABS
plastic shell.
1.2 Specification Table
Uniplay Model
UNIPLAY 7-A
UNIPLAY 10-A
Part Number
P561
P562
Resolution
1024x600
1024x600
Processor
600MHz
600MHz
Display Size
7" TFT LCD
10.1" TFT LCD
Brightness
450 cd/m2
400 cd/m2
Colours
24-bit
24-bit
Ethernet Port
1 x 10/100 Base-T
1 x 10/100 Base-T
Memory
Flash Storage: 128MByte
Flash Storage: 128MByte
RAM: 128Mbyte
RAM: 128Mbyte

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
1-7
Uniplay Model
UNIPLAY 7-A
UNIPLAY 10-A
Power Supply
24Vd.c.+-20%
24Vd.c.+-20%
Max Power Consumption
~400mA~24vd.c.
Module Size (H x W x D)
200 x 145 x 34mm
273 x 213 x 36mm
Weight
0.56kg
0.92kg
Panel Cut-out Dimensions
192 x 138mm
260 x 202mm
CE marked for EMC
Yes
Yes
RoHS
Compliant
Compliant
Operating Temperature
0 to 50℃
0 to 50℃
Storage Temperature
-20 to 60℃
-20 to 60℃
IP Rating
Front IP65*
Back IP20
Front IP65*
Back IP20
* When fitted correctly to an appropriate panel.

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
1-8
1.3 Dimensions
Uniplay 7-A
Uniplay 10-A

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
1-9
1.4 System Configuration
During application development and machine commissioning the typical configuration is to connect the
Uniplay HMI to the Trio Motion Coordinator via an Ethernet switch. This allows for a Motion Perfect
Ethernet connection to the Motion Coordinator for programming, debug and diagnostics.
Once the application program is complete, the Uniplay HMI can be connected directly to the Ethernet port
of the Trio Motion Coordinator.

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
2-10
Chapter 2 Installation
2.1 Environmental considerations
WARNING
⚫Do not use in places that are exposed to direct sunlight, wind or rain.
⚫Do not use in places that are susceptible to chemical contamination, corrosive or
flammable gases.
⚫Do not use in locations where there is a risk of explosion, such as where flammable
gases, steam or dust are present.
⚫Do not cause condensation inside the device.
⚫Do not use in environments where the temperature changes significantly or where
the humidity is high, this can cause condensation inside the device.
2.2 Cabinet Installation
The Uniplay HMI unit should be embedded into a panel or other suitable flat surface.
On the panel surface, cut a rectangular opening suitable for the unit to be mounted. Dimensions for the
opening are:
Uniplay Model
UNIPLAY 7-A
UNIPLAY 10-A
Panel Cut-out Dimensions
192 x 138mm
260 x 202mm
Place the unit into the opening.
Insert the metal fixings supplied with the unit top and bottom. There are four mounting positions on the
back of the Uniplay HMI unit, insert the fixing screws (included) and tighten them with a crosshead
screwdriver.

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
2-11
Ensure that the HMI seal is making good contact with the panel around the unit.

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
3-12
Chapter 3 Wiring and Connections
3.1 Connectors
The connectors are positioned on the bottom edge of the Uniplay HMI unit.
3.1.1 Power
Power terminal (Pin 1 to 3 from left to right)
Input voltage: DC24V ± 20%
Connector
Pin
Function
1
FG
2
0V
3
DC24V
CAUTION
Do not use a supply voltage other than that specified above. Using an incorrect
power supply may damage the device
3.1.2 USB
Connector
Type
Function
USB Type A
USB Host
Power
reserved
USB Host
USB Slave
Ethernet

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
3-13
3.1.3 Ethernet
The Ethernet interface is the main communication interface between the UNIPLAY HMI and the Trio
Controller.
Connectors
Pin
Name
Function
Pin 8 Pin 1
1
TX+
Send data +
2
TX-
Send data -
3
RX+
Receive data +
4
-
-
5
-
-
6
RX-
Receive data -
7
-
-
8
-
-
Shell
PE
Protecting earthing (shield)
Cable Description
Use category 5 (CAT5e SF/UTP) Ethernet communications cables for network connections. Metal shielded
connectors are recommended to prevent signal interference.
Micro USB
reserved

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
4-14
Chapter 4 Operation
All configuration and programming of Uniplay is performed using Motion Perfect v5.0 (or above).
4.1 Motion Perfect
Motion Perfect is a Microsoft Windows™ based application for the PC, designed to be used in conjunction
with Trio Motion Technology's range of multi-tasking motion controllers, servo drives, HMI and IO expansion
products.
A PC with the following specifications is required to run Motion Perfect:
Minimum
Recommended
Operating System
Windows 71
Windows 10
.NET Library
4.6.2
Processor
Dual core
2 or more cores
RAM
2GBytes
4GBytes+
Hard Disk Space
200MBytes + space for projects
500MBytes
3D Graphics
DirectX 9
DirectX 11
Communications
Ethernet
Ethernet
[1] Windows 7 is no longer supported by Microsoft. Although basic functionality on Windows 7 will continue
to be tested. Support will continue as long as possible, however, there is no guarantee that all
functionalities will work or that support will continue.
Motion Perfect is a free download and is available to from the Trio web site (www.triomotion.com).
4.2 Initial Setup
To program a Uniplay device it must be connected to a Trio controller via Ethernet and the Trio controller
needs to be connected to a PC via Ethernet and the PC needs to be running Motion Perfect.

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
4-15
4.2.1 Initial Connection
To make the initial connection to a controller:
•Make sure that your controller is powered up and connected to the computer
•Start Motion Perfect. Once it has started up the initial screen should be displayed.
•Select "Connect in Sync mode" from the "Controller" menu. As Motion Perfect has not been
connected before the "Connection" dialog will be displayed.
•Select the ‘Ethernet’ as the communications interface used by your controller. Then enter the IP
address of the controller (default 192.168.0.250) and the TCP port (default 23).
•Click on the "Apply & Connect" button. The "Connect" will close and Motion Perfect will go into
Sync Mode showing the the Controller Tree on the left.
The Uniplay panel default IP address is 192.168.0.251
The HMI panel must be aware of the Motion Coordinator IP address. If this is not at default use Motion
Perfect Tools->Setup Uniplay HMI device screen to store the Motion Coordinator IP address into the panel.
Note: If there is no HMI design on the controller the HMI will display
‘No HMI content found on the Motion Coordinator’

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
4-16
4.2.2 Updating Uniplay software
Motion Perfect will always contain the latest Uniplay software build. This software on the Uniplay panel
can by updated using Motion Perfect Tools->Setup Uniplay HMI device. To update the Uniplay panel
software click the Update… button, shown in the screen shot below.
Motion Perfect will open a file explorer to allow selection of the software update. By default, this will
open at the Motion Perfect folder with the latest software.
4.2.3 Licensing the Uniplay device
If the HMI shows a red border, this may mean that the software is not licenced correctly. Please contact
Trio technical support, details can be found on the web site (www.triomotion.com).
4.3 Running
Once the system has been programmed, the Trio controller will serve the HMI pages to the Uniplay device,
so there is no need for a connection to Motion Perfect.

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
4-17
4.4 Creating an HMI Design
Right mouse click on “Programs” or use Program->New on the menu
Ensure the HMI filter is checked and select ‘HMI Page’ under ‘HMI Design’ Select HMI Page under “Add New
Program”, and give the page a name:

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
4-18
Select the target HMI type:
The new blank page will open in the editor:

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
4-19
The components on the left-hand column can be dragged and dropped on the page.
The top border tools are used to edit and align pages.
In the simple example below a “Label” and a “TextBox” component have been dragged onto the HMI page:
The properties of each component can be edited by a menu brought up using a right mouse click:

Uniplay User Manual
Document Version: V1.0
(Apr, 2021)
© 2021 Trio Motion Technology Ltd. All right reserved.
4-20
Further pages are made in the same way as the first page by right-clicking “Programs”.
Table of contents
Other Estun Monitor manuals