EXALITE

OVERVIEW
Thank you for using our product, this unit is designed for indoor using, it’s widely used for stage, building, disco, etc. as high
power led effects lighting, this unit can be operated as a single unit or multipe units for large applications. Direct input of
DMX512 signal to unit to allow it controlled by any DMX controller, powerful internal programs and friendly and convenient
operation interface allows customers to program freely to any different lighting project requirements for installation or
showing.
This high power par can has gotten the nice sculpt, efficient, save electricity and durable。
This product complies with the following standards:
EN61000-3-2:2006+A2:2009
EN60598-1:2008+A11:2009
Technical Parameter:
•LED POWER: 200W
•LED Color: 200W 2in1 WW+CW
•IC Chip :Epistar
•LED Life Time: over 10,000 hours
•Color Rendering Index(CRI): Ra≥90
•Voltage :AC90-260V 50-60Hz
•Max.power consumption: 260W
•Beam angle: Zoom from 15°to 38°
•Dimmer :0~100% linearly adjustable
•Strobe :1-25times/sec
•Refresh Rate:>400 Video Flicker Free
•Focus: Can be adjusted by hand
•Technology: High-quality optical system , Glass reflector
•Control protocol: DMX 512
•Control System: DMX, Auto run and Master/Slave
•DMX Channels: 2/5CH(2in1)
•Working Temperature: -30~40℃
•Cooling System:Low noise fan(one fan)
•Thermal Sensor Monitoring: Over-temperature Protection
•IP Grade: IP20
•Net Weight: 11kgs Gross Weight: 14kgs
•Packing Size: 80x30.5x31cm

1. Product Introduction
1.1. Product Feature
4 kinds of running mode
External control mode (Slave mode)
DMX 512 controller control(2 kinds channel modes)
Master/salve model control (auto match the signal from controller and the Master light, no need to
set by menu)
Auto run mode (Master mode)
Different kind of Gradual change& Random change
Different kind of Strobe:speed change strobe (slow to fast)、mixing strobe( Strobe +basic color、
Strobe +Gradual change)……
static mode (Master mode)
It can fix any color without the controller ,also work this color with strobe
Sound mode (Master mode)
Included 2 kinds of commonly used sound mode
“Software cutting ”
The light would be turn off when the dimmer channel is "0"(procedure would keep working)
The difference with “BLACKOUT” key(controller keys) &"Software cutting" :only work this light , and
do not clear up the controller data .
No-liner dimmer &liner dimmer
The Effect get high praise from the professional technologist.
Screen Protect
It will enter blank screen without any operate on the keyboard in 30 seconds . Press any keys then it can
quit screen protection.
Temperature Protection
It can be set to temperature protection mode
Speed of the Fan
The fan will start to work when the working temperature reach 40 degree, and the speed will be changed
according to the change of temperature.
Can support reverse display

1.2. Multi-light working in the same time
When using controller to control multi lights to work in strobe, the controller just send the channel data . The
strobe effect will be depend on each light itself . And please take attention for the follow situation:
1. There will be many situations make the lights are not synchronization in the beginning. (For example: the
different time of opening the light , or different time of them connect to the controller) .In this case, you can
change value of the controller( for example push 20 to 0, and back to 20), then it can be synchronization.
2. Due to crystal frequency of different lights are not the same exactly, so it may not be synchronization
after long time.
3. If need to keep synchronization for long time, there are two ways to do so:
A. Using the controller to edit program make the strobe, auto run effect,then they must be synchronization.
B. Using the Maser/Slave model
2. Operation
2.1. Key-operation
Menu:
The first list is the main menu (press MENU to exchange), the
second list is vice menu (press ENTER to get in or exchange)
If the menu include the decimal point, that’s the data, and can
be set by the Key of Up/Donw.
Key operation:
Key of “MENU” (Press it and can save the data)
If it’s the main menu, it will exchange to next main menu.
If it’s the vice menu, it will back to main menu.
Key of “ENTER” (Press it and can save the data)
If it’s the main menu and it have vice menu, it will enter the
vice menu.
If it’s the vice menu, it will exchange to the next vice menu.
Key of “UP/DOWN”
It’s no function if the menu not include the decimal point.
If the menu include the decimal point, it can set the data after
the decimal point. And it need press “ENTER” to save the
data.

2.2. Menu
Menu
State
Operation
Remark
Main menu
Vice menu
No menu
A: advance
UP/DOW
N
adjust ID address
disconnect the
controller and
connect the master
light, then it will
follow the master
light.
It will flicker when
no signal.
External control
mode
(standard channel
model)
ENTER
Save ID address
No vice menu
d: dmx
UP/DOW
N
Adjust ID address
External control
mode
(basic channel model)
ENTER
Save ID address
One vice menu
At: auto
UP/DOW
N
choose the program
Aoto run model
ENTER
enter the vice menu
SP: speed
UP/DOW
N
adjust speed
choose the auto run
model
ENTER
save the data
No menu
Sod: sound
UP/DOW
N
change to sound
model
sound model
ENTER
save data
With multi
menus
StAt: static
ENTER
enter vice menu
static mdel
……
r、G、b、W……
UP/DOW
N
change the color
data
set the color
ENTER
save the data
change to vice
menu
St: strobe
UP/DOW
N
change the strobe
data
the strobe and its
speed
ENTER
save and exchange
have 2 vice
menus
tEMp: temperature
ENTER
enter the vice menu
temperature control
function
current temperature
ENTER
change to vice
menu

t: top
UP/DOW
N
Change the
temperature
protection data
set the temperature
protect
ENTER
save and exchange
No vice menu
diSP: display
ENTER
reverse display
set to show reverse
display
No vice menu
reSt: reset
ENTER
enter the interface
of key
The password is
“UP DONW UP
DOWN”
return Initial State

2.3. Channel data
2.3.1. Standard channel model
channel
data
function
mark
1
0~255
dimmer
2
0~255
color1
3
0~255
color 2
4
0~10
no strobe
this channel control the speed when running
the build-in program
11~255
the speed of strobe (255 is the
fastest)
5
0~20
speed of dimmer 4 (the slowest and
softest)
21~40
speed of dimmer 3
41~60
speed of dimmer 2
61~80
speed of dimmer 1
81~99
speed of dimmer off (fastest and no
any delay)
100~109
inner program 1
……
each 10 data is a program
190~199
inner program 10
200~240
change color by sound control
241~255
strobe by sound control
2.3.2. Basic channel model
channel
data
function
1
0~255
color 1
2
0~255
color 2

SAFETY WARNING
1. Warning
﹡Every person involved with the installation , operation and maintenance of this device has to be qualified .
﹡User must follow the instructions of this manual
﹡Unqualified person can not open the housing cover and operate the device , or the dealer will not accept liability for any
resulting defects or problems.
﹡The device against rain and moisture
2. Waring notes :
﹡Power supply : AC 100V-240V , 50/60Hz
﹡Make sure the power switch is off , the power plug , outlet and the earth connection is in well condition before
connecting the device with the mains.
﹡Please use qualified power plug and the outlet. Never connect the power cord of this device with other electrical
equipment.
﹡During move and installation , make sure the device not crashed with metal parts and other tough materials.
﹡Always disconnect from the mains, when the device is on the installation and dismantled
﹡The minimum distance between light-output and the illuminated surface must be more than 50cm
﹡The device must only be installed on a non-flammable surface . In order to safeguard sufficient ventilation , leave 50cm
of free space around the device . Please note that heat-sensitive objects may be deformed or damaged by the emitted
heat .
﹡During the operation the housing becomes very hot ! Do not operate the device for 15 minutes after switching off .
﹡The maximum ambient temperature Ta = 45℃must never be exceeded , The maximum housing temperature Tb =
80℃must never be exceeded .
﹡For indoor use
﹡Replace any visible cracked protective shield , filters and lens .
﹡The protective shiel, filters and lens will require weekly cleaning as smoke “Cfluid tends to building up residues ,
reducing the light “Coutput very quickly.

APPENDIX
Problem and solution

Caution :
﹡Unqualified person involved with installation , operation and maintenance of this device is prohibited .
﹡If any above mentioned problem happened , or unknown problem happened , please contact manufactory or distributor
or distributor for assistance
DISCLAIMER
1. The device is with one year warranty . The warranty period appear non-artificial quality problem, this company is
responsible for free maintenance
2. User violate operation caused the machine failure, this is user responsibility.
3. If due to the wrong operation or intense impact caused product destroy even safety accidents, the manufacturer does
not undertake any responsibility
4. Prohibit replaced product components by any person, therefore caused any consequences will be whose responsible
Please contact us freely when you need our related products or informations...
PRODANCE, s.r.o.
Osadní 799/26, 170 00 Praha 7
T: 220 806 054 E: i[email protected]
www.prodance.cz
Table of contents
Popular Floodlight manuals by other brands

Beamz
Beamz LCB183 user manual

Home Zone Security
Home Zone Security ES06508V installation instructions

Festool
Festool SYSLITE DUO Original operating manual

StreamLight
StreamLight F-STOP operating instructions

Strend Pro
Strend Pro AG-HFLAL20W-W-Y instruction manual

LumX
LumX LED floodlight instruction manual

Good Earth Lighting
Good Earth Lighting SE1249-BP2-02LF7-G manual

Osram
Osram Clay Paky Alpha Spot HPE 1500 instruction manual

MobilePower
MobilePower 4035 instruction manual

MaxLite
MaxLite HL-AR80 Series operating instructions

Showlite
Showlite FL-2010(B) manual

Eaton
Eaton All-Pro MST1301LW instruction manual