PLEASE READ AND FOLLOW ALLWARNINGS
Florida Pneumatic
A Divisionof Florida Pneumatic Manufacturing Corporation
851 JupiterPark Lane, Jupite r , Florida 33458
(561) 744-9500 •Fax (561) 575-9134 • Toll Free 1-800-327-9403
Read these instructions carefully before attempting to install,
operate or service this Universal Tool product. Failure to
comply with the instructions could result in personal injury and/
or property damage! Retain these instructions for future
reference.
Tool Application and Usa ge
Portable tools shall be used only for
the purposes intended in their design
and within the capacity for which they
were intended and rated. It shall be
the tool owner’s and/or employer’s
responsibility to instruct each operator
in the safe use of the tool. Tools shall
not be used without guards and safety
devices as furnished by the manufac-
turer. Where an air tool is modified or
altered, the modifier shall provide the
safeguards to enable it to be safely used
in the operations intended and to comply
with any applicable provisions as
contained in ANSI B186.1.
Tool Installation
Pressure regulators shall be used to limit
air pressure to the rated pressure where
the supply pressure exceeds the tool’s
rated pressure. Air hoses and lines shall
be relieved of compressed air before
being disconnected or disjointed, unless
there is automatic valve closing protec-
tion at the joint being separated. Syn-
thetic lubricants which can cause
deterioration of elastomer seals shall not
be used in air systems of air tools.
Tool
Maintenance
It shall be the tool owner’s and/or
employer’s responsibility to assure that
tools are maintained in a safe operating
condition. Tool maintenance and repair
shall be performed by authorized,
trained, competent personnel. Tools shall
be disconnected from their compressed
air supply before repairs are attempted.
Repairs shall be consistent with the
manufacturer’s recommended proce-
dures. Tool, hoses and fittings shall be
replaced if unsuitable for safe operation.
It shall be the tool owner’s and/or
employer’s responsibility to keep required
rating markings and warnings on the tool
in legible condition.
FPMC
Read Operating Instructions
Always become familiar with all the
instructions and warnings before
operating any power tool.
Always Wear Approved
Eye Protection
Impact resistant eye protection
should meet or exceed the
standards as set forth in the United
States ANSI Z87.1, Occupational
and Educational Eye and Face
Protection. Look for the marking
Z87.1 on your eye protection to
insure that it is an approved style.
For further information, ANSI Z87.1,
Occupational and Educational Eye
and Face Protection, is available
from the American National
Standards Institute, Inc., 11 West
42nd Street, New York, NY 10036.
Hearing Protection is
Recommended
Hearing protection should be used
when the noise level exposure
equals or exceeds an 8 hour time-
weighted average sound level of 85
dBA. Process noise, reflective
surfaces, other tools being
operated nearby, all add to the
noise level present in your work
area. If you are unable to determine
your noise level exposure, we
recommend the use of hearing
protection.
Avoid Prolonged Exposure to
Vibration
Tools can vibrate during use.
Prolonged exposure to vibration
or
very repetitive hand and arm
movements, can cause injury.
Stop using any tool if discomfort,
tingling feeling or pain occurs. You
should consult your physician
before resuming use of the tool.
90 PSIG Maximum
This tool is designed to operate at
An air pressure of 90 pounds per
square inch gauge pressure (90
PSIG) maximum, at the tool. Use of
higher air pressure can, and may
cause injury. Also, the use of
higher air pressure places the
internal components under loads
and stresses they were not
designed for, causing premature
failure. The air supply should be
clean and dry, preferably
lubricated. For best results, drain
the moisture from your compressor
daily.
WARNING:
Some dust created by power sanding,
sawing, grinding, drilling, and other
construction activities contains chemicals
known to cause cancer, birth defects or
reproductive harm. Some examples of
these chemicals are:
•Lead from lead-based paints
•Crystalline silica from bricks, cement
and other masonry products
•Arsenic and chromium from chemi-
cally treated lumber
Your risk from these exposures varies,
depending on how often you do this type
of work. To reduce your exposure to
these chemicals, work in a well-ventilated
area and work with approved safety
equipment such as those dust masks that
are specially designed to filter out
microscopic particles.
Safety Instructions
The following instructions are fur-
nished as general guidelines for use
of your pneumatic tool. They cannot
comprehensively cover all possible or
conceivable uses of the subject tool.
For additional information on the safe
use of air tools, we advise you to
obtain a copy of CAGI B186.1-2009
Safety Code for Portable Air Tools,
available from the following source:
COMPRESSEDAIRAND GAS INSTITUTE
1300 Sumner Avenue
Cleveland, OH 44115-2851
Ph: 216-241-7333
www.cagi.org OR from
Florida Pneumatic Manufacturing Corp.
851 Jupiter Park Lane
Jupiter, FL 33458
561-744-9500 www.florida-pneumatic.com
The use of the word “shall” in the
following instructions, indicates that
adherence to the particular require-
ment is necessary to conform to CAGI
B186.1-2009.
Description
FP-2000
HIGH SPEED SANDER
Florida Pneumatic high speed sander is ideal for feather edging and produc-
tion sanding. This tool features a lightweight, impact resistant nylon handle
and spring mounted trigger. Three backing discs are included in 3", 4-1/2"
and 5-1/2" diameter sizes for added versatility. Assembled in USA.
Specifications
FP-2000
HIGH SPEED SANDER
Free speed........................................................................................................... 20,000 RPM
Backing disc size(s)..........................................................................................3", 41/2", 51/2"
Center hole size................................................................................................................7/8"
Length.............................................................................................................................7 3/4"
Weight.........................................................................................................................13/4 lbs.
Air inlet......................................................................................................................1/4"NPT
Recommended hose size........................................................................................3/8" I.D.
Average air consumption...........................................................................................4 CFM
Maximum operating pressure....................................................................................90psi
1 * Barrel 101020
2 * Bearing carrier (2) 102010
3 ° * Bearing (2) 102020
4 * Cage 103010
5 * Hub 107020
6 ° Pad nut 110010
7 Holding rod 110210
8 Barrel retaining pin 111220
9 T/V retaining pin 111230
10 * Front end plate 113010
11 * Rear end plate 113120
12 ° O-ring (2) 115120
13 O-ring (2) 115160
14 * Stop ring 115210
15 * Rotor 116020
16 ° * Vane (4) 116210
17 Spring 118020
18 Trigger body 120120
19 Trigger stem 120220
20 Trigger button 120310
21 Handle 262048
25 3" ber pad 5403
26 4 1/2" ber pad 5404
27 5 1/2" ber pad 5405
28 Auxiliary handle 5814
(*) Motor unit complete 425310
(°) Tune up kit 200 Kit
Not shown.

Other Florida Pneumatic Sander manuals

Florida Pneumatic Universal Tool UT8756-1 User manual

Florida Pneumatic

Florida Pneumatic Universal Tool UT8756-1 User manual

Popular Sander manuals by other brands

Festool SHINEX RAP 150-14 FE Original operating manual

Festool

Festool SHINEX RAP 150-14 FE Original operating manual

Grizzly G1079R Machine data sheet

Grizzly

Grizzly G1079R Machine data sheet

BN BNSPW-100 Operation manual

BN

BN BNSPW-100 Operation manual

Grizzly G0529 owner's manual

Grizzly

Grizzly G0529 owner's manual

Chicago Electric 97593 Set up and operating instructions

Chicago Electric

Chicago Electric 97593 Set up and operating instructions

Rikon Power Tools 51200 Operator's manual

Rikon Power Tools

Rikon Power Tools 51200 Operator's manual

General 15-010 M1 Setup & operation manual

General

General 15-010 M1 Setup & operation manual

Ozito RANDOM ORBITAL SANDER instruction manual

Ozito

Ozito RANDOM ORBITAL SANDER instruction manual

Rockwell ShopSeries RS4503 manual

Rockwell

Rockwell ShopSeries RS4503 manual

Grizzly T32004 owner's manual

Grizzly

Grizzly T32004 owner's manual

Villager VLN 320 Original manual

Villager

Villager VLN 320 Original manual

Alto American 12 Operator's manual

Alto

Alto American 12 Operator's manual

Hitachi SV 13YA Safety instructions and instruction manual

Hitachi

Hitachi SV 13YA Safety instructions and instruction manual

DeWalt DCE800 Original instructions

DeWalt

DeWalt DCE800 Original instructions

F.F. Group OS 150 EASY Original instructions

F.F. Group

F.F. Group OS 150 EASY Original instructions

Rac MV008 user manual

Rac

Rac MV008 user manual

ULTIMATE SPEED UPM 120 B1 Original instructions

ULTIMATE SPEED

ULTIMATE SPEED UPM 120 B1 Original instructions

Milwaukee 6130-33 Operator's manual

Milwaukee

Milwaukee 6130-33 Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.