Trouble Shooting TipsExploded View of Wash System
Tub and Door Seal
The door seal is pressed into the tub channel for
aninterferencefit.Centerthegasket(markedon
back) at the tub top center and press in place
ProductSpecifications
Electrical
Rating...................................120 Volts, 60Hz
Separate Circuit..15 amp min.- 20 amp max.
Motor (Amps) ........................................... 1.1
Heater Wattage.......................................900
Total Amps (load rated).........................10.0
TempAssure .............................. 140°F ±5°F
(60°C±3°C) [with outer door in place]
TempBoost.............145°F ±5°F (63°C ±3°C)
Heated Wash/Heated Rinse
Sanitize ..................150°F ±5°F (66°C ±3°C)
Hi-Limit Thermostat ................ 200°F (93°C)
Water Supply
Suggested minimum incoming water
temperature............................. 120°F (49°C)
Pressure (PSI) min./max.................... 20/120
Connection (NPT) .....................................3/8"
Consumption (Normal Cycle) .......................
.............4.9 - 9.7 U.S. gal., 18.5 - 36.7 liters
Water valve flow rate (U.S. GPM)........... .83
Water recirculation rate (U.S. GPM) ..............
.................................................... approx. 12
Water fill time.....................................87 sec.
To replace dispenser:
• shut off electricity to dishwasher,
• remove outer door panel assembly,
• disconnect wiring to the actuator,
• remove the six screws,
• remove the dispenser,
• replace and reinstall screws,
• rewire actuator.
Power Dry Air Flow
The Power Dry configuration is the same as the
Standardexceptithasacrossflowblowerlocated
in the air discharge path. The blower assists the
heating element in producing power to drive the
moist air out of the dishwasher.
Check the Following
1. Fuse (blown or tripped).
2. 120 VAC supply wiring connection
faulty.
3. Electronic control board defective.
4. No 12 VAC power to control.
5. Motor (inoperative).
6. Door switch (open contacts).
7. Door latch not making contact with
door switch.
8. Touch pad circuit defective.
9. No indicator lamps illuminate when
STARTorOPTIONS arepressed.
1. Motor(badbearings).
2. Motor stuck due to prolonged
non-use.
1. Improper voltage.
2. Motor windings shorted.
3. Glass or foreign items in pump.
1. Heaterelement (open).
2. Electronic control board defective.
3. Wiring or terminal defective.
4. Hi-Limit thermostat defective.
1. Latch mechanism defective.
2. Electronic control board defective.
3. Wiring or terminal defective.
4. Broken spring(s).
5. Defective actuator.
1. Drain restricted.
2. Electronic control board defective.
3. Defective drain pump.
4. Air lock in drain hose.
5. Blockedimpeller.
6. Openwindings.
7. Wiring or terminal defective.
1. Water supply turned off.
2. Defective water inlet fill valve.
3. Check fill valve screen for
obstructions.
4. Defective float switch.
5. Electronic control board defective.
6. Wiring or terminal defective.
7. Float stuck in “UP” position.
1. Drain hose (high) loop too low.
2. Drain line connected to a floor drain
not vented.
3. Drain hose not connected to side of
tub.
1. Detergentallowedtostandtoolongin
dispenser.
2. Dispenser wet when detergent was
added.
3. Detergentcoverheldclosedorblocked
by large dishes.
4. Improperincoming water
temperature to properly dissolve
detergent.
5. See "Detergent cover will not open."
Always disconnect the dishwasher from the electrical power source before adjusting or
replacing components.
Personal Injury Hazard
900 Watt Heater
Refer to the cycle chart on the reverse side to
determinewhentheheaterisonduringthewash
cycle. The heater cycles ON and OFF for brief
periods during the drying cycle.
Voltage checks of the heater should be made in
the dry portion of the service test mode.
attached by a worm gear clamp to the discharge
ofthedrainpump.The drainisthenroutedupthe
side of the dishwasher and attached to the side
of the tub. This drain loop insures that an air
pocket cannot form near the drain pump and
causethepump to airlock.The drain loop onthe
sideofthetubmustbekeptinplaceafterservicing.
The main pump can easily be removed by
disconnecting the upper spray arm supply tube
hose,the drain pump connector hose,the wiring
harness connections made at the circulation
motor, the water heat thermistor located on the
bottom of the pump and rotating the four sump
retainers toward the middle of the sump.
PumpAssembly
The pump assembly is driven by a synchronous
motor. Rotation is in the counterclockwise
directionat3600RPM. The motor drives apump
which supplies 100 percent filtered water at a
rate of approximately 12 GPM to one spray arm
atatime.Thespray arm’soperationisalternated
by small “pauses” of the motor during the wash
cycle.
Draining is accomplished by using a small
separate synchronous drain pump mounted to
the side of the sump. The drain pump is
connected to the main pump by a small rubber
hose. The drain check valve is located at the
entrance to the drain pump. The drain hose is
withoutstretchingorbunching.Thegaskettakes
a short turn at the bottom of the tub channel
before ending at the channel end wall.
Short Turn
Gasket Cross Section
DetergentandRinseAidDispenser
The detergent and rinse aid dispenser is a one
piece component consisting of a molded
detergent cup and a built-in rinse aid dispenser.
The detergent cup has a spring loaded cover
and the rinse aid dispenser has a removable
cover.
Liquid rinse aid is added to the dispenser up to
the fill line indicator. The amount of rinse aid
released can be adjusted by turning the arrow
indicator from one, being the least amount, to
four, being the greatest amount.
Mounting
Rib
Tub
Interior
Remedy
1. Replace fuse or reset breaker.
2. Repair or replace wire fasteners at
dishwasher junction box.
3. Replace controlboard.
4. Replace controlboard.
5. Replacemotor/impellerassembly.
6. Replace latch assembly.
7. Replace latch assembly.
8. Replace console assembly.
9. Replace console assembly.
1. Replace motor assembly.
2. Rotatemotor impeller.
1. Check voltage.
2. Replacemotor/impellerassembly.
3. Clean and clear blockage.
1. Replace heaterelement.
2. Replace controlboard.
3. Repair or replace.
4. Replacethermostat.
1. Replacedispenser.
2. Replace controlboard.
3. Repair or replace.
4. Replacedispenser.
5. Replacedispenser.
1. Clear restrictions.
2. Replace controlboard.
3. Replacepump.
4. Make sure hose is attached in proper
position on side of tub.
5. Check for blockage, clear.
6. Replacepumpassembly.
7. Repair or replace.
1. Turn water supply on.
2. Replace water inlet fill valve.
3. Disassemble and clean screen.
4. Repair or replace.
5. Replace controlboard.
6. Repair or replace.
7. Clean float.
1. Repair to proper height.
2. Install air gap at counter top.
3. Reattach drain hose.
1. Instruct customer/user.
2. Instruct customer/user.
3. Instruct customer/user on proper
loading of dishes.
4. Incoming watertemperatureof
120°F is required to properly
dissolve dishwashing detergents.
Symptom
Dishwasherwill notoperate when
turnedon.
Motor hums but will not start or run.
Motortripsout oninternalthermal
overloadprotector.
Dishwasherrunsbut willnotheat.
Detergent cover will not latch or
open.
Dishwasherwill notpumpout.
Dishwasher will not fill with water.
Dishwasherwatersiphonsout.
Detergentleft indispenser.
Standard Dry Air Flow
Whenthecontroladvancestothe“dry”portion of
thecycle,alinearactuatorretractsavalve,which
opens a vent path through the console into the
kitchen.This venting method eliminates
discharging heated moisture into the motor
compartment. The heated, moist air leaving the
dishwasher through the console vent causes
drierairto be drawn into theunitbyway of intake
vents located at the bottom of the door. The
water on the dishes is evaporated into drier air
and the venting process continues. The heating
element is turned ON and OFF during the entire
drying cycle.
010222
Nozzle
Funnel
Nut
Funnel Base
Center Spray Arm
Lower Spray Arm
Delivery Tube
Connector Hose and Clamps
Sump
Water Valve
Water Inlet Tube
Check Ball
Circulation
Motor Assembly
Motor Bracket
Incoming Water Supply
Drain Hose
Spray Arm
Support
Glass Trap
Heating
Element
Filter
Soil Director
Volute Cover
Drain Motor
Sump Retainers (4)