Important Information- Read Me rst
IMPORTANT NOTICE
U.S. Export Administration Regulations, pursuant to ECCN 2B350, prohibit the export or re-export to certain
enumerated
countries of air operated double diaphragm pumps in which all wetted materials are constructed from uoropolymers
without rst applying for and obtaining a license from the U.S. Bureau of Industry and Security(BIS). This aects all FTI
AIR pumps constructed from PVDF with PTFE balls and diaphragms. Please contact the BIS (www.bis.doc.gov) or FTI
Air with questions regarding the Regulations or a list of the countries to which they apply.
Chemical Reaction Disclaimer
The user must exercise primary responsibility in selecting the product’s materials of construction which are
compatible with the uid(s) that come(s) in contact with the product. The user may consult FTI Air (manufacturer) and
a manufacturer’s representative/distributor agent to seek a recommendation of the product’s material of construction
that oers the optimum available chemical compatibility.
However neither manufacturer nor agent shall be liable for product damage or failure, injuries, or any other damage
or loss arising out of a reaction, interaction or any chemical eect that occurs between the materials of the product’s
construction and uids that come into contact with the product’s components.
Unpacking & Inspection
Unpack the pump and examine for any signs of shipping damage. If damage is detected, save the packaging and
notify the carrier immediately.
To install the pump, follow the installation instructions provided.
Safety Precautions for ATEX Pumps
WARNING: READ THIS SUPPLEMENTAL INSERT COMPLETELY BEFORE INSTALLING AND OPERATING THIS
PUMP. FAILURE TO FOLLOW THESE PRECAUTIONS CAN RESULT IN SERIOUS INJURY OR DEATH.
WARNING: Static sparking can cause explosion. When operating in a hazardous area or pumping
a hazardous uid, the pump’s grounding screw and entire pump system must be grounded to earth to
prevent static discharge. This includes but is not limited to pipes, hoses, tanks, containers, valves, etc.
Before operating the pump, ensure the electrical continuity throughout the pumping system and earth
ground is 1 Ohm or less. If it is greater than 1 Ohm, re- check all grounding connections.
WARNING: Static sparking can cause explosion. Excessive uid ow rates and improper tank lling
methods can produce static electricity causing an explosion. Ensure safe uid velocities and tank lling
procedures in compliance with EN 13463-1 and CLC/TR 50404.
WARNING: Vibrations from operation may cause mounting surfaces and connections to loosen and
generate a spark. Ensure the pump and connections are securely mounted and fastened prior to each
operation.
WARNING: Do not exceed minimum and maximum temperature limits of pump components. A table of
temperature limits is provided in the “Material Proles” section of the manual.
WARNING: Prior to operating, check pump for any worn o-rings, gaskets, or seals. Any leaking or
damaged o-rings, gaskets, or seals must be repaired or replaced immediately.
WARNING: Do not exceed maximum pressure stated on the pump serial number sticker.
WARNING: Pump exhaust may be loud and contain particles. Wear appropriate ear and eye protection.
In the event of a diaphragm rupture material can be forced out of the air exhaust muer.
WARNING: Pump must be cleaned on a regular basis to avoid dust buildup greater than 5mm.