FULGOR M6 Manual

M6
Digital audio matrix with DSP
USER AND INSTALLATION GUIDE
V3.0
Software da 3.0.0.4
Firmware da 3.0.0.0

2
Features can be modified without any notice V2020319
PRECAUTION OF USE
WARNING: To reduce the risk of electric shock, do not remove the cover (or rear panel).
Inside, there are no parts that can be repaired by the user; Entrust the repair to qualified personnel.
CAUTION: To reduce the risk of fire or electric shock, do not expose this unit to rain or moisture.
This symbol, when displayed, indicates the presence of a non-insulated hazardous voltage inside
the body of the device - sufficient voltage to pose a risk of electric shock.
This symbol, when displayed, indicates important operating and maintenance instructions in the
enclosed text. Read the manual.
RECOMMENDATIONS:
All safety and operating instructions must be read before operating the appliance.
Keep the instructions:
Safety and operating instructions must be kept for future reference. This manual is an integral part of the
product and must accompany it in case of any change of ownership. This will allow the new owner to know
the instructions for installation, operation and safety.
Pay attention:
All warnings on the appliance and operating instructions must be followed accurately. Observe all warnings.
Follow the instructions:
All operating and user instructions must be followed.
Notes preceded by the symbol contain important safety information: Read them carefully.
DETAILED SAFETY INSTRUCTIONS.
Water and humidity:
The appliance should not be used close to water (eg near baths, kitchen sinks, near pools, etc.).
Ventilation:
The appliance must be placed in such a way that its location does not interfere with the proper ventilation.
For example, the appliance should not be placed on a bed, sofa cover, or similar surfaces that can block the
ventilation openings or placed in a recessed installation such as a bookcase or cabinet that can prevent the
flow of air, Air through the ventilation openings.
Heat:
The appliance must be located away from heat sources such as radiators, thermostats, clothes dryers, or
other appliances that produce heat.
Power supply:
• The appliance must only be connected to the type of power described in the operating instructions or on
the appliance.
• If the supplied plug does not match the socket, contact an electrician to install an appropriate socket.
Grounding or polarization:
• Precautions should be taken to ensure that grounding and polarization of the device are not affected.
• The metal parts of the equipment are connected to ground via the power cord.
• If the power socket does not have a ground connection, contact a qualified electrician to connect the
grounding device through the terminal.
• For plastic equipment, periodically check the condition of the power supply.

3
Features can be modified without any notice V2020319
Power Cord Protection:
The power supply cord must be installed so that it is not to be trampled or pinched by objects placed on or
against, paying particular attention to wires and plugs that are wall-mounted.
Cleaning:
• When the unit is to be cleaned, dust can be removed using a compressed air jet or damp cloth.
• Do not clean the unit using solvents such as triethylene, paint thinners, fluids, alcohol, high volatility fluids
or other flammable liquids.
Non-use Periods:
The power cord of the appliance must be disconnected from the socket if it is not used for a long time.
Intake of liquids or objects:
Care should be taken to avoid dropping objects and not leaking liquids into the body of the appliance through
the grilles.
Safe use of the power line:
• When disconnecting the appliance, hold the plug and the socket securely.
• When the unit is not used for a prolonged period, stop power by pulling the plug out of the power outlet
• To avoid damaging the power supply line, do not pull the power cord and do not use a twisted cable.
• To avoid damaging the power cord of the apparatus, make sure that it is not being trodden or crushed by
heavy objects.
Moving the unit:
Before each shift, make sure the drive is off. The power cord must be removed from the socket as well as
the unit's connections with other lines.
Do not disassemble the unit:
Do not attempt to disassemble or repair the unit yourself. For any problem that can not be resolved with the
help of this manual, contact a qualified technician or contact our company www.fulgorservice.it
Malfunctions:
For any malfunctions contact our company (www.fulgorservice.it).
IMPORTANT SAFETY RULES:
• Install by following the instructions.
• Never open the equipment: inside there are no user-serviceable parts.
• If you notice a strange smell coming from the appliance, turn it off immediately and disconnect the power
cord.
• Do not obstruct the ventilation grilles of the appliance.
• Avoid working overloading the unit for extended periods of time.
• Do not force commands (buttons, controls, etc.)
• For safety reasons, do not unscrew the plug-in connection. The ground connection is necessary to safeguard
operator safety
• Use only the connectors and accessories specified by the manufacturer.
• The equipment must be kept away from:
Damp places
Direct exposure to heat sources (such as sunlight).
Unsuitable ventilation
• In the presence of lightning storms or when the apparatus is not in use, unplug the power plug from the
socket.
• To prevent the risk of fire and electric shock, keep the equipment away from splashes and drops. Above
the apparatus should not be placed vases or other objects containing liquids.
• FULGOR SERVICE s.n.c. Disclaims any liability for incorrect installation of the unit.
GUARANTEES AND RETURN:
The product is equipped with a guarantee of operation and compliance with its specifications, as stated by
the manufacturer. The warranty is 24 months from the date of purchase. Faults detected within the warranty
period, attributable to defective materials or construction defects, must be promptly reported to your dealer
or distributor, enclosing the purchase date documentation and the description of the defect type found.
Failures caused by improper use or tampering are excluded from the warranty. Fulgor Service s.n.c.

4
Features can be modified without any notice V2020319
Establishes by means of return verification the declared defect, related to proper use, and the effective
validity of the guarantee; It then provides for the replacement or repair of the products, but does not however
oblige any compensation for direct or indirect damages resulting from the defect.

5
Features can be modified without any notice V2020319
M644
DAW in real time 6 Input on 4 Out
DESCRIPTION
The M6 digital workstation is equipped with 6 balanced audio input (XLR) fully configurable and
addressable to one or more of the 4 balanced outputs (XLR).
Main electrical characteristics:
6 balanced inputs with female XLR connectors
4 balanced output with male XLR connectors
Maximum input level 8Vpp
Maximum output level 8Vpp
Input amplification: from -20dB to +50dB
Phantom power +24 V can be activated independently on each channel via software
24 bit analog/digital conversion
Less than 6w consumption
20 Digital volume controls (RS485)
32 Preset selectable and actionable remotely (RS485)
6 fully configurable remote analog volume controls
6 fully configurable panel volume controls with precision potentiometers
RS232 serial line for configuration and setting via PC (Windows)
Main software features:
Gain control for each input (±50dB)
Phase control for each input
Compressor for each input
Equalization with 3 configurable parametric filters for each input
6x4 matrix with adjustable attenuations
Configurable automixer with 5 logical parameters
NOMA function (total output level attenuation with automatic control according to the
actual inputs open simultaneously)
Double antilarsen selectable for each output
1 delay for each output settable from 0 to 64 meters
Equalization with 6 parametric filters configurable for each output
Noise-Gate on each output
Gain control for each output (-60/+6dB)
Phase control for each output
Maximum-minimum configuration of the potentiometer that can be associated with one or
more of the inputs or outputs
Block diagram summary screen of the running configuration
RS485 enabling/disabling
Display of inputs and output status (VuMeter) in each window of the work environment
and virtual keys to enable/disable the inputs and outputs (Muting)
Display of the preset control and accessori functions window (name change, save to disk,
load from disk, set password, default, exit, resources control and save) in each window of
the work environment

6
Features can be modified without any notice V2020319
STATUS LED
LED PRESET STATUS
PRECISION POTENTIOMETERS PC INTERFACE
MULTIFUNCTION PORT
POWER
BALANCED OUTPUTS
GROUND LIFT
BALANCED INPUTS

7
Features can be modified without any notice V2020319
SOFTWARE
WELCOME WINDOW
From this window it is possible to select the serial port to connect to the matrix, or perform an
off-line configuration, that is, without the device being connected.
MAIN WINDOW
You can access this window or from off-line configuration or by connecting to the device.

8
Features can be modified without any notice V2020319
Detail
This window is always visible in any work environment you are; it is thus possible to check inputs
and output level and enable/disable the muting function.
In the exmaple shown all inputs are open while all the output are in muting condition.
To assign a name to an input or output, right-click on the input or output itself.
Clicking in the tab “Modifica
nome” you can assign one.
Monitor for connection status (ON-LINE o OFF-LINE),
serial, service version (software running on PC),
firmware (of the device) and total DSP resources

9
Features can be modified without any notice V2020319
From this section it is possible to choose and/or save
the presets, select the factory configuration (default)
and save.
☝It is necessary to save frequently in order not
to risk losing the change made; when it is
stored the tab is partially obscured.
From this section it is possible to change the project
name, assign a new password (default ****), save
the project on the computer, upload a project from
the computer or close the work section.
☝When you change the project name it is shown
on the upper left side of the work environment

10
Features can be modified without any notice V2020319
Inputs Tab
For each input it is possible to adjust/select:
Gain by writing the value or pressing the up-down
buttons (min -50 dB max +50dB)
Mute
Phase
24V Phantom power
Managed by automixer
Controlled by a local or remote potentiometer
Activate the dynamics compressor
☝When the automixer is not active, the relevant tab is
partially obscured and therefore CANNOT be
selected.
☝It is possible to control both inputs and outputs with
an internal or external potentiometer and it is also
possible to assign multiple inputs/outputs to a single
potentiometer. It is necessary to calibrate the
potentiometers.
☝When the dynamics compressor is active, the
relevant operation light (triangle near the Th value)
indicated whether the input is open (green) or closed
(red). The wworking range is between -30dB and
+6dB (Th treshold, or operating treshold) with a
compression level (Ratio) variable from 1 (1:1) to 15
(15:1).

11
Features can be modified without any notice V2020319
Fulgor Service Automatic System
To activate the automatic control of the inputs, check the box "Abilitato".
From this section it is possible to check and/or modify the parameters of the automatic system developed by Fulgor Service and check the
status of the inputs.
The example graph on the right shows the operating principle of the automation.
Parameter Value Function Example
Attenuazioni
Negative (dB)
Set the attenuation to inputs
that are not working
Settings -15dB; 15dB
attenuation is applied to the
inputs that are not working and
that have the check mark on
“automixer”
Differenza di livello per
diventare leader
Positive (dB)
Settings -15dB; 15dB
attenuation is applied to the
inputs that are not working and
that have the check mark on
“automixer”
3dB setting; the working input
with the tick on “automixer”
are checked and the one that
exceeds the other by 3dB
becomes (in that moment) the
leader
Num. max ingressi aperti in
simultanea
Number
Settings -15dB; 15dB
attenuation is applied to the
inputs that are not working and
that have the check mark on
“automixer”
Setting 3; only 3 of the inputs
that have the tick on
“automixer” will be able to
work simultaneously
Differenza di livello
apertura in simultanea
Negative (dB)
It sets the maximum difference
that the working inputs must
have with respect to the leader
to be actually open
Setting 7dB; if the inputs that
have the tick on “automixer”
reach a minimum level within
7dB respect to the leader (ex.
the leader reaches -7 dB ▶
minimum opening level -14dB)
they will be open, otherwise
they will remain closed.
N.O.M.A.
Number of Open Microphones
Attenuated
Keeps the output level constant
depending on the number of
microphones actually open
If a microphone is working, the
system does not intervene, as
you add (open) microphones,
the system intervenes by
decreasing the mixer output
level in percentage to have a
constant level
Sensibilità minima di
apertura degli ingressi
dB
It decides what is the minimum
level that an input must reach
in order to be opened
-40dB setting; if the inputs
with the check mark on
“automixer” reach at least -40
dB they can be opened

12
Features can be modified without any notice V2020319
INPUT EQ
From this section it is possible to view the equalization curve of the various inputs; by clicking
on the name of an input, the relevant equalization curve is displayed.
👉Each input has a different graph color
👉It is possible to scroll the graph by using the mouse wheel
👉It is possible to copy the equalization by right-clicking on the graph and pastina on the
graph of another input (always using the right mouse button)
Clicking on the tab “Flat” the equalization of the displayed input is canceled
You can also choose to display the graph in s pseudo-tridimensional mode by clicking on
“Barre”
Clicking on tab “Editor Filtri” the adjustment filters window opens

13
Features can be modified without any notice V2020319
Filters Editor
3 filters are available for each
input:
It is possible to select the
Frequency (Freq.), the merit
factor (Q) that determins the
slope and type of filter, i.e. low-
bass (LP) – high-pass (HP) –
parametric (EQ)
👉 By choosing a low-pass or a
high-pass the merit factor is
raised automatically to 0,5
👉 By choosing the parametric,
the filter will have a slope directrly
proportional to the merit factor Q.
A very low Q will give a narrow
filter, vice versa it will give a wide
filter.

14
Features can be modified without any notice V2020319
MATRIX
From this section it is possible to direct one or more inputs to one or more outputs by selecting
the intersections of the matrix “by putting a check mark”.
For each intersection it is possible to attenuate the level
By clicking on the tab “Azzera tutto”, all the intersections are deleted (none on none)
By clicking on the “Imposta tutto” all the intersections are created (all on all)
👉 The gain of the matrix can only be attenuated, it is NOT possible to increase it.
👉 By right-clicking it is possible to change the inputs/outputs names.

15
Features can be modified without any notice V2020319
BYPASS
From this section it is possible to direct one or more input to one or more output by selecting
the intersections of the bypass matrix “by putting a check mark”.
This Bypass matrix skips the entire effects path (equalizer – antilarsen - noise gate and delay)
by directly connecting the inputs to the outputs.
By clicking on the tab “Azzera tutto”, all the intersections are deleted (none on none)
By clicking on the “Imposta tutto” all the intersections are created (all on all)
👉 The intersections previously occupied by the matrix are not availables
👉 By right-clicking it is possible to change the inputs/outputs names.

16
Features can be modified without any notice V2020319
OUTPUTS EQ
From this section it is possible to display the equalization curve of the various outputs; by
clicking on the name of an output, the relevant equalization curve is displayed.
👉 Each output has a different graph color
👉 It is possible to scroll the graph by using the mouse wheel
👉 It is possible to copy the equalization by right-clicking on the graph and pasting it on the
graph of another output (always using the right mouse button)
By clicking on tab “Flat” the output equalization is deleted
You can also choose to display the graph in a pseudo-tridimensional mode by clickng on
“Barre”
By clicking on the tab “Editor Filtri” the adjustment filters windows opens.

17
Features can be modified without any notice V2020319
Filter Editor
6 filters are available for each
outputs:
It is possible to select the
Frequency (Freq.), the merit
factor (Q) that determins the
slope and the type of the filter, i.e.
low-pass (LP) – hihg-pass (HP) –
parametric (EQ)
👉 By choosing a low-pass or a
high-pass the merit factor is
automatically raised to 0,5
👉 By choosing the parametric,
the filter will have a slope directly
proportional to the Q merit factor.
A very low Q will give a narrow
filter, vice versa it will give a wide
filter

18
Features can be modified without any notice V2020319
ANTILARSEN
DELAY
DELAY
D
From this section it is possible to enable an antilarsen for each output.
Phase type antilarsen bases its functioning on phase modulation managed by an algorithm
developed by Fulgor Service
Freq type antilarsen (Frequency) bases its functioning on the frequency shift managed by an
algorithm developed by Fulgor Service, which uses the principle of traditional analog antilarsen
👉 With Phase antilarsen it is suggested to set the “Delay Antilarsen” to 1,8ms. and the
“Velocità (speed) Antilarsen” to 1,80Hz
👉 With Freq antilarsen Freq the “Delay Antilarsen” is locked and the “Velocità (speed)
Antilarsen” should be adjust between 1 and 1,80Hz

19
Features can be modified without any notice V2020319
DELAY
From this section it is possible to enable a delay for each output.
The delay is expresssed in meters to facilitate the calculation (reference temperature 20°C)
👉 The maximum delay that can be set is 64 meters equal to approximately 186ms

20
Features can be modified without any notice V2020319
NOISE GATE
From this section it is possible to enable a noise gate for each output by clicking on “on”.
The adjustment parameters allow you to set the functioning minimum level, the delay in
intervening and the “speed” with which it intervenes.
“Soglia Intervento”: between -40dB and +1dB; the noise gate intervenes when it reaches or
below the selected threshold
“Ritardo Intervento”: between 0dB and 10dB; once the threshold has been reached, the noise
gate waits fora time equal to the value selected before intervening
“Pendenza di Chiusura”: between 0,1 and 5 expressed in dB/sec; once the threshold has been
reached and the selected time has elapsed, the noise gate closes the output with a slope qual
to the chosen one; this parameter can also be considered as closing speed since the higher it
is, the faster the minimum level is reached.
👉 When the noise gate intervens, the light next to the writing Gate changes color
👉 Under the adjustment sliders there is a VuMeter of the output
Table of contents
Popular Matrix Switcher manuals by other brands

Shinybow USA
Shinybow USA SB-5688LCM instruction manual

Ethereal
Ethereal CS-88MHDBTS user manual

Rose electronics
Rose electronics UltraMatrix 4 Installation and operation manual

Key Digital
Key Digital KD-MSW4X2 operating instructions

Kramer
Kramer VS-4228 user manual

Video Storm
Video Storm CMX1616A2 owner's manual

Kramer
Kramer VS-6EII user manual

Lightware
Lightware MX2-8X8-HDMI20-AUDIO user manual

Shinybow USA
Shinybow USA SB-5645 instruction manual

Extron electronics
Extron electronics DXP 1616 HD 4K PLUS Series Setup guide

Gefen
Gefen EXT-HDMI1.3-848CPN user manual

Vision HD
Vision HD MX0402-310 operating instructions