6PAGE
IMPORTANT
TO REDUCE THE RISK OF CLOTHING ENTANGLEMENT IN COMPLIANCE WITH ASTM F1487, ANY BOLT END
PROTRUDING MORE THAN TWO FULL THREADS BEYOND THE FACE OF THE NUT SHALL BE CUT-OFF FLUSH, FILED
SMOOTH AND TREATED TO PREVENT CORROSION.
NOTE: LOCTITE (SUPPLIED BY OTHERS) SHOULD BE USED ON ALL THREADED HARDWARE.
NOTE: AFTER ASSEMBLY IS COMPLETE, PEEN TEE-NUTS AND FLATWASHERS TO MATCH RADIUS OF PIPE.
13
23456
90091, 90092, 90093, 90095, 90096, & 90097
DETAILS −for−
1
0INCH
0CM 123 6457
8 9 10 1211 14 15
1'-0"
[30.48 cm]
VARIES
(REFER TO OVERALL
SHOCK ABSORBING
MATERIAL
3.9" [10.00 cm]
MAX.
45~MIN.
CONCRETE
BRICK OR
EQUIVALENT
SHOCK ABSORBING PROPERTIES OF SURFACING
MATERIALS VARY. IF YOU DETERMINE THAT LESS
THAN 1'-0" [30.48cm] OF SURFACING IS REQUIRED,
MAKE UP THE DIFFERENCE IN ELEVATION WITH
EARTH, BEFORE APPLYING SURFACING.
"A"
"B"
UNIT GROUND PLAN)
1 1/16" [2.70 cm]
1 5/16" [3.33 cm]
1 5/8" [4.13 cm]
1 7/8" [4.83 cm]
2 3/8" [6.03 cm]
3 1/2" [8.89 cm]
5" [12.70 cm]
5" [12.70 cm]
TRACK RIDE & SWINGS
(PIPE SIZE)
DIA. "A"
1'-2" [35.56 cm]
1'-6" [45.72 cm]
1'-6" [45.72cm]
2'-0" [60.96 cm]
1'-2" [35.56 cm]
1'-2" [35.56 cm]
1'-2" [35.56 cm]
1'-2" [35.56 cm]
(FOOTING SIZE)
DIA. "B"
-SUGGESTED MINIMUM CONCRETE
OF EUROPEAN STANDARD EN1176-1 ONLY
-SLOPED FOOTING IS A REQUIREMENT
RATING: 3000 PSI
NOTES:
BRICK OR
DIMENSIONED
TO TOP OF 5" [12.70 cm]
TREE SCAPE
4'-0" [121.92 cm]
EARTH
EQUIVALENT
032