GARZ&FRICKE Neso LT series User manual

NESO LT 4.3" Open Frame Manual
For PCB revision 0.7 or for HW 1.1 or later

NESO LT 4.3" Open Frame Manual
2
Content
1Introduction 3
2Safety Hints 4
3Product Introduction 5
Product introduction 53.1 Type plate and device information 53.2 Related documents and online support 63.3
4Product Description 7
Technical data 84.1 PCB design 104.2
5Installation and start up 11
Connection Scheme 115.1
6External interfaces and Schematics 12
Ethernet (X8) 12
6.1 Power/Digital out (X1) 126.2 RS-232/RS-485/CAN (X9) 136.3
6.3.1 Option: RS-232/RS-485 13
6.3.2 Option: RS-232/CAN 13
USB - Host (X12) 146.4 External USB - OTG (X14) 146.5 Speaker (X5) 146.6 Line out (X20) 156.7 S/PDIF (X7) 156.8 Keypad/SPI (X16) 166.9
6.9.1 Standard: Keypad/SPI 16
6.9.2 Option: Keypad/SPI/I²C 16
Battery-Holder (X2) 176.10
7Document revision history 18
8Technical support 18
Annex A: Assembly options and accessory 20
A-1 NESO LT 4.3” Open Frame Version M 20
Annex B: Hardware revision information 21
Annex C: Mechanical specifications 22
C-1 Mechanical Drawings 22
Annex D: Quality and Incoming Inspections 23
D-1 Display 23
D-2 Evaluation Criteria of standard display module 30
Annex E: Battery 31
E-1 Battery Specifications 31
E-2 Replacement of the internal battery 32
Annex F: Guidelines and Standards 33
F-1 EMC Pretests 33
F-2 RoHS Declaration 33
Annex G: Common documentation 34
G-1 Warranty hints 34
G-2 Application notes 35
G-3 Trademarks and service marks 35

NESO LT 4.3" Open Frame Manual
3
1 Introduction
Thank you very much for purchasing a Garz & Fricke product. Our products are dedicated to professional use
and therefore we suppose extended technical knowledge and practice in working with such products.
The information in this manual is subject to technical changes, particularly as a result of continuous
product upgrades. Thus this manual only reflects the technical status of the products at the time of
printing. Before design-in the device into your or your customer’s product, please verify that this
document and the therein described specification is the latest revision and matches to the PCB
version. We highly recommend contacting our technical sales team prior to any activity of that kind.
The attached documentation does not entail any guarantee on the part of Garz & Fricke GmbH with
respect to technical processes described in the manual or any product characteristics set out in the
manual. We do not accept any liability for any printing errors or other inaccuracies in the manual
unless it can be proven that we are aware of such errors or inaccuracies or that we are unaware of
these as a result of gross negligence and Garz & Fricke has failed to eliminate these errors or
inaccuracies for this reason.
Garz & Fricke GmbH expressly informs that this manual only contains a general description of
technical processes and instructions which may not be applicable in every individual case. In cases of
doubt, please contact our technical sales team.
In no event, Garz & Fricke is liable for any direct, indirect, special, incidental or consequential
damages arising out of use or resulting from non-compliancy of therein conditions and precautions,
even if advised of the possibility of such damages.
Before using a device covered by this document, please carefully read
Annex G-1 Warranty hints
Annex G-2 Application notes
Embedded systems are complex and sensitive electronic products. Please act carefully and ensure
that only qualified personnel will handle and use the device at the stage of development. In the event
of damage to the device caused by failure to observe the hints in this manual and on the device
(especially the safety instructions), Garz & Fricke shall not be required to honour the warranty even
during the warranty period and shall be exempted from the statutory accident liability obligation.
Attempting to repair or modify the product also voids all warranty claims.

NESO LT 4.3" Open Frame Manual
4
2 Safety Hints
Please read this section carefully and observe the instructions for your own safety and correct use of the
device. Observe the warnings and instructions on the device and in the manual. Garz & Fricke embedded
systems have been built and tested by us and left the company in a perfectly safe condition.
In order to maintain this condition and ensure safe operation, the user must observe the instructions and
warnings contained in this manual.
I. General handling
Don’t drop or strike the unit: The PCB, display and/or other parts might be damaged.
Keep away from water and other liquids, the unit is not protected against.
Operate the unit under electrical and environmental conditions according to the technical
specification.
The electrical installations in the room must correspond to the requirements of the local (country-
specific) regulations.
Take care that there are no cables, particularly power cables, in areas where persons can trip
over them.
Do not place the device in direct sunlight, near heat sources or in a damp place.
All plugs on the connection cables must be screwed or locked to the housing.
Repairs may only be carried out by qualified specialist personnel authorized by Garz & Fricke
GmbH or their local distributors.
Maintenance or repair on the open device may only be carried out by qualified personnel
authorized by Garz & Fricke GmbH which is aware of with the associated dangers.
II. LCD and touch handling
If equipped with, the soft surface of a resistive touch screen is not suitable for use with stencils
and/or other devices for touch operation. There are special plastics pens available in commercial
shops. A projective capacitive touch screen might be protected by a heat strengthened glass or
acrylic or polycarbonate cover lens. These are dedicated for use with finger tips. There are very
special pens available which might work with a PCT touch.
Protect the LCD/touch/cover lens against scratches and sharp edges. The warranty does not
cover pixel failures resulting from non-compliant handling.
Clean the LCD/touch/cover lens with a soft cotton cloth with alcohol. Don’t use organic solvents,
acid or alkali solutions.
Water drops, finger fat or any similar fouling should be removed immediately from the LCD,
cover lens and metal frame to avoid any staining.
III. Electricity
The embedded systems may only be opened in accordance with the description in this user’s
manual for
replacing of the (rechargeable, where applicable) lithium battery and/or
configuration of interfaces, where applicable
These procedures have to be carried-out only by qualified specialist personnel.
When accessing internal components the device must be switched off and disconnected from the
power source.
When purchased core or basic versions without protecting back cover, don’t touch the PCB
directly with your fingers. Especially these products need to be handled very carefully.
Don’t operate or handle the unit without typical ESD protection measures, such as ground
earthing.
Operate the unit according to the technical specification only.
IV. Damage or permanent malfunction
It must be assumed that a safe operation is no longer possible, in case
the device has visible damage or
the display is dark or shows strange pattern for longer period
the device doesn’t react after a reset
In these cases the device must be shut down and secured against further use

NESO LT 4.3" Open Frame Manual
5
3 Product Introduction
This document is applicable for hardware revisions 1.0 or later of the NESO LT SERIES and thereon based
customized variants. Please note that customized variants might possibly not support all features listed herein.
Please find the hardware version grid in Annex B:
Product introduction3.1
NESO LT is an Embedded System to be used as human machine interface (HMI) in various applications.
Please refer to G-2 Application notes for further information. The system is equipped with a large number of
industrial interfaces. A wide variety of options is available as well.
Type plate and device information3.2
For service and later identification of the device, the type plate contains important information, such as article
numbers (linked to the PCB rev.), the order code and model name (which is valid for all PCB rev.) and the
serial number, that identifies the exact device.
(Exemplary illustration)

NESO LT 4.3" Open Frame Manual
6
Related documents and online support3.3
This document contains product specific information. Additional documentation is available for the use of
embedded operating systems and the related tool chain and the RedBoot BIOS.
Title
Link to Garz & Fricke Website
Description
RedBoot User Manual
GF_RedBoot_User_Manual_V.0.7.pdf
Contains relevant information about
BIOS, boot logo, display settings, etc.
Windows OS Manual
GF_WindowsCE_Manual_V1.3.1.pdf
Contains information about Windows
Embedded CE, the tool chain, the
development environment Visual
Studio, Garz & Fricke tools, etc.
Linux PTX OS Manual
gf_linux_manual_neso-lt-1.42.0-0
Contains information about Linux BSP,
the tool chain, Qt, etc.
Support for your Garz & Fricke embedded device is available on the Garz & Fricke website. You may find a list
of the documents available, as well as their latest revision and updates for your system:
Product
Link to Garz & Fricke Website
NESO LT 4.3" Open Frame
http://www.garz-fricke.com/nesolt-openframe_en.html

NESO LT 4.3" Open Frame Manual
7
4 Product Description
This drawing is meant for your orientation. For drawing please refer to Annex C: Mechanical specifications
You will get 3 D Modell (CAD) Drawings after signed a NDA contract.
(Exemplary illustration)
Installation frame
Display with resistive touch
Reset switch
Micro SD-
card slot
Power LED
Connectors and interfaces
Back cover
Internal Speaker
6,3 mm male spade terminal

NESO LT 4.3" Open Frame Manual
8
Technical data4.1
CPU
Class
ARM9R ARM926EJ-S™i.MX257
Type/Clock
400 MHz
RTC
Depending on ambient temperature
Standard time´s deviation: +/- 30 ppm at 25°C
Memory
NAND Flash
256 MByte NAND Flash
RAM
Standard
128 MByte DDR-SDRAM
Option
256 MByte DDR-SDRAM
Micro SD Card Slot
4 bit MicroSD(HC)
Interfaces External
Network
1x 10/100 Mbit/s Ethernet (RJ45)
Serial
1x RS-232 (Rx/Tx/RTS/CTS)
1x RS-485
CAN Fieldbus
CAN Option
1x CAN (ISO/DIS 11898) instead of RS-485
USB 2.0
1x 12 Mbit/s Full-Speed Host
1x 480 Mbit/s High-Speed OTG
Keypad/SPI/I²C
multiplexed
Default
1x 7x7 Keypad, 1x I²C
Mode 1
1x 4x4 Keypad, 1x I²C, 1x SPI
Mode 2
1x 8x8 Keypad
Mode 3
1x 5x5 Keypad, 1x SPI
Speaker
1x speaker (connector), 1.5W RMS (8Ω)
Digital I/O
1x Digital Out (0.7 A)
Audio
S/PDIF, Line Out
LCD Display
Size [inch/mm]
4.3 / 109.3
Display Technology
TFT TN
Width x Height [pixel]
480 x 272
Colors [bit]
24 (16.7 M colors)
Backlight Unit
LED
Luminance1[cd/m²]
280 (Min.) 320 (Typ.)
Active Area W x H [mm]
95.04 x 53.86
Viewing Angle
Typ. 70/ 70/ 60/ 65 (L/ R/ U/ D)
Condition CR>10
Resistive Touch
Type
4-wire analog resistive
Linearity
<=1.5%
Surface Treatment
antiglare
Power Supply and Consumption
Supply [V DC]
Nom. 12
Max. 9 ~ 16
Consumption [W]
Typ. 3.6
Internal Backup Battery
Type
3 V lithium manganese dioxide Type CR1220
Lifetime (RTC only)
Approximately 8 years, depending on application
1
Luminance applies to the entire device.

NESO LT 4.3" Open Frame Manual
9
Housing
Back Cover
1.4016 high quality steel, polished, 0.8mm
Mounting Plate
ABS-PC, metallized
Approximate Dimensions
W x H x D [mm]
130.2 x 67.2 x 25.4
Weight [g]
190
Environment
Humidity [%]
5 ~ 90 (non condensating)
Operating Temperature [°C]
0 ~ +60
Storage Temperature [°C]
-20 ~ +70
Max. Operating Altitude [m]
3,000
Max. Storage/Transit
Altitude [m]
10,000
Noise Level [db(A)] @ 1m
<<40 (fanless design)
Lifetime
Backlight Lifetime2LCD
Display [h]
30,000
Operating Lifetime Touch
100,000 (by pen), 1,000,000 (by finger)
MTBF3[h]
≥ 50,000
2
Backlight lifetime is dictated by the LCD manufacture´s specification. Backlight lifetime is the approximate time at which
the brightness decreases to half of its original brightness. Reduction of brightness due to backlight lifetime is not
considered as failure. It is a natural aging of all electronic components.
3
Electrical products use the industrial standard term Mean Time between Failure (MTBF) as a statistical prediction of the
elapsed time between failures in a large population of systems.
The MTBF of all Garz & Fricke HMI products shall be 50,000 hours
A failure is anything that causes the product not to function to its specifications
Reduction in brightness due to backlight lifetime is not a failure
If the LCD used in the system exceeds its pixel defect specification it is considered a failure

NESO LT 4.3" Open Frame Manual
10
PCB design 4.2
As this manual describes an open frame version, only the external interfaces
will be mentioned in the following chapter.
Pos.
Description
Pos.
Description
1
Ethernet (X8)
8
S/PDIF (X7)
2
Power/Digital out (X1)
9
Keypad/SPI (X16)
3
RS-232/RS-485/CAN (X9)
10
Reset
4
USB - Host (X12)
11
Clear all (Bootmode select)
5
External USB - OTG (X14)
12
Power LED
6
Speaker (X5)
13
SD card reader
7
Line out (X20)

NESO LT 4.3" Open Frame Manual
11
5 Installation and start up
The content of this document is limited to explain the device connectors and how to access NESO LT via FTP
over your local area network (LAN) within a few seconds. For advanced hardware specifications and software
support, please refer to chapter 3.3
Product
Link to Garz & Fricke Website
NESO LT 4.3" Open Frame
http://www.garz-fricke.com/nesolt-openframe_en.html
Connection Scheme 5.1
(Exemplary illustration)

NESO LT 4.3" Open Frame Manual
12
6 External interfaces and Schematics
Ethernet (X8) 6.1
Pin
Name
Description
Level
1
Tx+
2
Tx-
3
Rx+
4
SPARE1
5
6
Rx-
7
SPARE2
8
Header:
RJ45
Power/Digital out (X1)6.2
Pin
Name
Description
Level
1
GND
Ground
2
GND
Ground
3
Vcc_In
Input voltage
9-16V
4
DIO_OUT
Digital Out
Vcc_In
Header:
Molex_43045-0400 Micro-Fit 4p
Plug:
Molex_43025-0400 Micro-Fit 4p, crimp contact
Molex 43030-0007

NESO LT 4.3" Open Frame Manual
13
RS-232/RS-485/CAN (X9)6.3
6.3.1 Option: RS-232/RS-485
Pin
Name
Description
Level
1
GND
Ground
2
RS232_TXD1
Port#1: Transmit data (Output)
3
RS232_RXD1
Port#1: Receive data (Input)
4
RS232_RTS1
Port#1: Request-to-send (Output)
5
RS232_CTS1
Port#1: Clear-to-send (Input)
6
Vref
Vref out
5V
7
GND
Ground
8
RS485_Y
TX+
9
RS485_Z
TX-
10
RS485_A
RX+
To enable Half-Duplex: bridge with RS485_Y
11
RS485_B
RX-
To enable Half-Duplex: bridge with RS485_Z
12
RS485_TERM
To enable RS485-Termination: bridge with
RS485_A
Header: Molex_43045-1200_Micro-Fit_12p
Plug: Molex_43025-1200_Micro-Fit_12p, crimp contact Molex 43030-0007
6.3.2 Option: RS-232/CAN
Pin
Name
Description
Level
1-5
RS-232
Identical to RS-485 option (s. 4.3.1.)
6
Vref
Vref out
5V
7
GND
Ground
8
CAN1_H
CAN bus 1 high
9
CAN1_L
CAN bus 1 low
10
CAN1_TERM
To enable CAN1-Termination, bridge with
CAN1_L
11
n.a.
12
n.a.

NESO LT 4.3" Open Frame Manual
14
USB - Host (X12)6.4
Pin
Name
Description
Level
1
Vcc
Power supply
5 V /500mA
2
D-
Data minus
3
D+
Data plus
4
GND
Ground
Header: USB Type A
External USB - OTG (X14)6.5
Pin
Name
Description
Level
1
Vcc
Power supply
5 V /500mA
2
D-
Data minus
3
D+
Data plus
4
ID
Device ID
5
GND
Ground
+Header: Micro-USB Type AB
Speaker (X5)6.6
Pin
Name
Description
Level
1
VO+
External speaker out +
Max. 1.5 W @ 8 Ω or 3 W @ 4 Ω
(X5 internally connected to X6)
2
VO-
External speaker out -
Header: JST S2B-PH-SM3-TB, side entry, RM = 2.0, 2-pin
Plug: JST PHR-2, crimp contact BPH-002T-P0.5S

NESO LT 4.3" Open Frame Manual
15
Line out (X20)6.7
Pin
Name
Description
Level
1
GND
Ground shielding
2
LINE_OUT_L
Line out, left channel
Max 1V RMS
3
LINE_OUT_R
Line out, right channel
S/PDIF (X7)6.8
Pin
Name
Description
Level
1
GND
Ground shielding
2
TXOUT
Signal out
Max 1Vpp, R = 75Ohm

NESO LT 4.3" Open Frame Manual
16
Keypad/SPI (X16)6.9
6.9.1 Standard: Keypad/SPI
Pin
Name
Description
Level
Standard mode
Multiplexed mode 1
1
GND
Ground
Ground
2
GND
Ground
Ground
3
KP_COL7_SS2
Keypad column 7
SPI 3 Slave Select 2
3,3V
4
KP_ROW7_SLK
Keypad row 7
SPI 3 Serial Clock
3,3V
5
KP_COL6_MOSI
Keypad column 6
SPI 3 Master out Slave
in
3,3V
6
KP_ROW6_MISO
Keypad row 6
SPI 3 Master in Slave
out
3,3V
7
KP_COL5_SS3
Keypad column 5
SPI 3 Slave Select 3
3,3V
8
KP_ROW5_DMA
Keypad row 5
SPI 3 Interrupt Request
3,3V
9
KP_COL4
Keypad column 4
Keypad column 4
3,3V
10
KP_ROW4
Keypad row 4
Keypad row 4
3,3V
11
KP_COL3
Keypad column 3
Keypad column 3
3,3V
12
KP_ROW3
Keypad row 3
Keypad row 3
3,3V
13
KP_COL2
Keypad column 2
Keypad column 2
3,3V
14
KP_ROW2
Keypad row 2
Keypad row 2
3,3V
15
KP_COL1
Keypad column 1
Keypad column 1
3,3V
16
KP_ROW1
Keypad row 1
Keypad row 1
3,3V
17
KP_COL0
Keypad column 0
Keypad column 0
3,3V
18
KP_ROW0
Keypad row 0
Keypad row 0
3,3V
19
GND
Ground
Ground
20
GND
Ground
Ground
Header: JST SM20B-SRDS-G-TF, side entry, RM = 1.00
Plug: JST SHDR-20V-S-B, crimp contact: SSH-003GA-P0.2
6.9.2 Option: Keypad/SPI/I²C
Pin
Name
Description
Level
Multiplexed mode 2
Multiplexed
mode 3
1-10
Identical to standard (pls. see 4.9.1.)
11
KP_COL3
I²C SDA
I²C SDA
12
KP_ROW3
I²C SCL
I²C SCL
13
KP_COL2
Keypad column 2
Keypad column 2
14
KP_ROW2
Keypad row 2
Keypad row 2
15
KP_COL1
Keypad column 1
Keypad column 1
16
KP_ROW1
Keypad row 1
Keypad row 1
17
KP_COL0
Keypad column 0
Keypad column 0
18
KP_ROW0
Keypad row 0
Keypad row 0
19
GND
Ground
Ground
20
GND
Ground
Ground

NESO LT 4.3" Open Frame Manual
17
Battery-Holder (X2) 6.10
Pin
Name
Description
Level
1
VCC
Supply
3 V
2
GND
Ground
Header: Keystone 1056
Battery: CR1220

NESO LT 4.3" Open Frame Manual
18
7 Document revision history
The information in this document is subject to change without prior notice in order to improve reliability, design
and function and does not represent a commitment on the part of the manufacturer.
Revision
Date
Author
Description
V.1.0
27.01.2015
LK
Initial document release for PCB revision 1.1.b
8 Technical support
Before contacting the Garz & Fricke support team, please try to help yourself by the means of this manual or
any other documentation provided by Garz & Fricke or the related websites.
If this does not help at all, please feel free to contact us.
Our technicans and engineers will be glad to support you. Please note that beyond the support hours included
in the Starter Kit, various support packages are available. To keep the pure product cost at a reasonable level,
we have to charge support and consulting services per effort.
Shipping adress:
Garz & Fricke GmbH
Tempowerkring 2
21079 Hamburg
Germany
Support contact:
Phone: +49 (0) 40 / 791 899-30
Fax: +49 (0) 40 / 791 899-39
E-Mail: support@garz-fricke.com
URL: www.garz-fricke.com

NESO LT 4.3" Open Frame Manual
19
Technical Appendix
For PCB revision 0.7 or for HW 1.1 or later

NESO LT 4.3" Open Frame Manual
20
Annex A: Assembly options and accessory
A-1 NESO LT 4.3” Open Frame Version M
NESO LT is also available as minor assembly version.
For the details of the external connectors please use the main part on the pages 12.
Pos.
Description
Pos.
Description
1
Ethernet (X8)
11
Reset
2
Power/Digital out (X1)
12
Clear all (Bootmode select)
3
RS-232/RS-485/CAN (X9)
13
Power LED
4
USB - Host (X12)
14
SD card reader
5
External USB - OTG (X14)
15
Other manuals for Neso LT series
1
Table of contents