GMC EVAPORATIVEAIR COOLER –IMPORTANT NOTES
1- After turning on the cooler, be sure that water pump should work for 3 minutes first, let water
evenly distributed onto cooling pads, then start fan and adjust fan speed. This step is very
important to prevent water drop from splashing on motor and helpful to prolong motor
lifespan.
2- Ensure the single-phase voltage is ± 5%. Too low or high voltage may cause damage to
cooler.
3- Before running cooler, please fill water tank with water, otherwise, cooler can not work
properly or even cause damage to water pump.
4- Do not use cooler inside an enclosed space; the places must be sufficiently ventilated.

2
GMC EVAPORATIVEAIR COOLER –
TECHNICAL DATA
Technical data of GMC EvaporativeAir CoolerAB18 Variable speed
Motor
Single-phase
Six-speed
Variable-frequency
motor
Effective space
120-150M2
Power supply 220V 50 Hz
Water supply 20-30L/H
Motor power 0.55-1.1 KW
Air outlet size
670 mm × 670 mm
Fan type Axial
Net Weight 58 kg
Pump type
submersible Gross Weight 68 kg
Fan size
590 mm Dimension 1070mm×1070mm×1090mm
Airflow 900-18000M3/H
Air outlet size 670 mm × 670 mm
Wire 3 M Control system LCD display
GMC EVAPORATIVE AIR COOLER –INSTALLATION TIPS
1-The supporting frame must be strong and firm enough to bear the weight of cooler and
maintenance technician.
2-The cooler installation must be horizontal, not acclivitous, otherwise, water will overflow from
the cooler water sump.
3- Ensure that drainage elbow is installed properly; keep it from cooler duct to avoid the water
drops go into the duct when it is windy.
4-The cooler should be installed at least 3 M away from the vicinity. Provide a minimum of 1 M
of clearance to any side of the cooler that requires access for maintenance.
GMC EVAPORATIVE AIR COOLER –USE INSTRUCTION OF SINGLE
PHASE, 6- SPEED VARIABLE

3
1- ON/OFF
When the power is on, press ON/OFF to start or stop the machine.
2- MODE
Press MODE to choose three operation modes: COOL, FAN or DRAIN.
COOL: I is the cooling figure. The water pump will run for three minutes first, water is
evenly distributed onto cooling pads, and then the fan starts. Press ▲▼to adjust airflow from 1-6.
FAN: is the fan figure. At this moment, the water pump does not work, only fan delivers
airflow. Press ▲▼to adjust speed from 1-6.
DRAIN: is the drain figure. When draining, the arrowhead runs.
3- TIME SETTING
Press TIME for the first time, you can set time of cooler start, adjust its starting time by pressing
▲▼; Press TIME for the second time, you can set time of cooler stopping, adjust its stopping
time by pressing ▲▼. Press TIME until the number flickers for three seconds, the time setting of
cooler starting and stopping is cancelled.
4- CLOCK
CLOCK is for clock setting. Adjust clock by pressing ▲▼.
5- SWING
Not used.
GMC EVAPORATIVE AIR COOLER – MAINTENANCE
1- If the cooler is used in very sandy and dusty areas, cooling pads should be often cleaned to
ensure cooling efficiency. When cleaning, do not use high pressure water, hot water (up to 40 ℃)
or chemical detergents.
2- Clean cooler water sump every half year to keep the cooling air clean and fresh.
3- Drain the water from water sump after the first 24 hours of new cooler operation, the odor will
not smell any more.
4- To prevent the cooler freezing and worms, do shut up water supply and keep the water sump
dry if the cooler will be leaved unused for a long time. Cover it in sandy or snowy weather if
necessary.
5- Make sure that all the cooler screws are not loose to prevent cooler from shaking severely when
its operation.

4
GMC EVAPORATIVE AIR COOLER –TROUBLESHOOTING
No
Malfunction Check Solution
1
No menu on LCD
panel
( only for LCD cooler)
1. Check if cooler is energized.
2. Check if signal wire connection is correct.
3. Check if main control board goes wrong.
1. Plug again and ensure power supply
2. Turn off and re-connect signal wire.
3. Replace main control board or fuse.
2 LCD is out of control
( only for LCD cooler)
1. Check if LCD main control board is burned up. 1. Replace main control board.
2. Replace display panel.
3 Blurry display
( only for LCD cooler)
1. Open controller bottom cover and check if circuit board is
dusty and/or contaminated.
2. Open controller bottom cover and check if circuit board is wet.
1. Clear off dust.
2. Properly blow off moisture.
4
“Er” displayed on
control panel
( only for LCD cooler)
1. Check if temperature sensor has problem. 1. Replace temperature sensor.
5
Cooler stops
automatically after 20
min when cooling
( only for LCD cooler)
1. Check if water level is too low.
1. Increase water pipe pressure.
2. Adjust float valve, make water level 7-10
CM high.
3. Replace water inlet valve.
6 Fan fails to deliver
airflow
1. Check if motor is damaged.
2. Check if fan blades are stuck.
3. Check if LCD main control board is damaged.
1. Replace motor.
2. Adjust fan blades position.
3. Replace contactor.
4. Replace capacitor.
5. Replace LCD main control board.
7 Cooler fails to deliver
cooling air flow
1. Check if there is water in the sump.
2. Check if the water level is too low.
3. Check if pump is in good condition.
1. Increase water pipe pressure.
2. Adjust float valve, make water level 7-10
CM high.
3. Ensure pump wire is connected.
4. Clean pump.
5. Replace pump.
8 Small airflow delivery
1. Check if there is impurity in cooling pads.
1. Clean cooling pads with normal city
water; do not use high pressure water
and any chemical detergent.
9 Drainage valve leaks
1. Check if there is too much impurity in water sump.
2. Check if water level is too high in water sump.
3. Check if drainage valve rubber ring is in good condition.
4. Check if pump is damaged.
1. Clean water sump.
2. Make water level 7-10 CM high.
3. Replace valve rubber ring.
4. Replace pump.

5
GMC EVAPORATIVEAIR COOLER –FAULT CODE
10
Water overflow from
cooler
1. Check if water level is too high in water sump.
2. Check if cooler is installed horizontally.
3. Check if sealing ring of float valve is in good condition.
4. Check if float valve is damaged.
1. Adjust float valve and make water level
7-10 CM high.
2. Adjust cooler installation horizontally.
3. Replace sealing ring of float valve.
4. Replace float valve.
11
Water drops splash
from cooler
1. Check if inner water pipes fall from joints.
2. Check if elbows fall from joints.
3. Check if cooling pads are blocked.
1. Fix inner water pipes again.
2. Fix elbows again.
3. Clean cooling pads.
12
Water drops splash
from duct 1. Check if drainage outlet is installed properly. 1. Extend drainage outlet length with pipe.
13
Violent vibration
when operation
1. Check if screws are loose.
2. Check if fan blades deform.
1. Fix screws.
2. Replace fan blades.

6
Other GMC Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual