1INTRODUCTION
SYSTEM CHARACTERISTICS
INSTALLATION WITH 'STADIO PLUS' PANELS
INDEX
OWhen combined on 'Stadio Plus' door panels, follow the assembly instructions supplied with the
door panel. Wire and program the access control module as it's explained in this instructions
manual.
First of all we would like to thank and congratulate you for the purchase of this product
manufacturedbyGolmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001
certificationandforthemanufacturingofproductslikethisone.
Itsadvancedtechnology andexactingquality controlwilldo thatcustomersand usersenjoywith
the legion of features this system offers. To obtain the maximum profit of these features and a properly
wiredinstallation,wekindlyrecommendyoutoexpendafewminutesofyourtimetoreadthismanual.
Introduction..........................................1
Systemcharacteristics ............................1
Installationwith'StadioPlus'panels..........1
Index ...................................................1
Moduleinstallation..........................2to3
Moduledescription................................3
Moduleprogramming..............................
IPoperationmode.........................4to5
Usersvalidation ...............................5
C4Plusoperationmode.......................6
Lockrelease installation ...........................7
Important notice ................................7
Installationdiagrams ...............................
Standaloneoperation...........................8
Combinedon 'Stadio Plus' panels ......8to 9
O
O
O
O
O
O
O
Stand alone access control module with proximity reader.
Compatible with PROXCARD ISO cards and NEOKEY key holders.
Aproximate reading distance: 7cm.
Up to 500 users in one or several memory addreses.
12Va.c. and 18Vd.c. inputs.
Possibility to be combined with any of the 'Stadio Plus' system installations or C4Plus access
control systems.
1 single shoot output relay with 3 seconds activation time.

3
2
1650
1850
1450
MODULE INSTALLATION MODULE INSTALLATION
mbedding box positioning.
E
The upper part of the module should be placed at 1,65m. height roughly.
The hole dimensions are: 125(W) x 140(Al) x 57(D) mm.
The module has been designed to be placed under most of the environmental conditions.
However it's recommended to take additional cautions like rainproof covers.
Break the bottom flange
to pass the cables through.
reparing the embedding box.
P
Pass the wiring through the hole made in
the bottom part of the embedding box.
Level and flush the embedding box.
Once the embedding box is placed,
remove the protective labels
from the attaching door panel holes.
Select a direction to open the module; this selection should ease
the door panel wiring.
The opening direction will be settled through the hinges position,
that must be passed through the header clips as shown.
For example, if the hinges are placed on both clips of the lower
header, the module will open downwards; if they are placed
on the right clips of both headers, the module will open to left.
To hold the module on the embedding box,
insert the hinges in the embedding box lockers
as shown.
Fix the module by using the supplied screws.
Finish the module assembly by pressing the closing heads.
MODULE DESCRIPTION
old the module on the embedding box.
H
The jumper placed on the right side of the 7 segments display
allows to select between two operation modes:
IP (stand alone mode or to be used with "Stadio Plus" panels)
or C4P. C4P mode is to be used with C4Plus access control
systems only.
odule description
M
power supply input.
data (only C4Plus mode).
relay common terminal.
relay output.
+, – :
S :
1 :
2 :
C4PIP
Installation terminal connector is located under the
module protection cover. The correspondance
of each terminal is as follows:

54
P operation mode.
I
IP mode allows to use this module in combination with "Stadio Plus"
panels, or to operate as stand alone module. The operation
mode selection is shown on page 3.
To enter into programming mode, a PIN code will be required.
This code of three digits length (override digit zero from left)
is sticked on the relay, placed on the left side of the display.
While programming, the led on the front part of the module
will light red. To exit from the programming mode, wait 20 sec.
from the last operation.
Press C button during 2 seconds.
The left digit display will show number 0.
To validate the code, press C button during 2 seconds:
the display will show the complete code.
In case of valid code, the display will show the
selected operation mode (IP). In case of wrong code,
the display will show the message "E–5" during
10 seconds and will automatically exit from the
programming mode.
Press arrow "DOWN" button to move to the next digit.
The left display will turn off and the center display
will show number 0.
Press arrow "DOWN" button to move to the next digit.
The center display will turn off and the right display
will show number 0.
Press arrow "UP" button till the first PIN digit will appears
on the display.
Press arrow "UP" button till the second PIN digit will
appears on the display.
Press arrow "UP" button till the last PIN digit will appears
on the display.
C
C
alidation of PROXCARD ISO cards
or NEOKEY key holders.
V
IMPORTANT: this module is to be used with ISO cards or key holders
supplied by Golmar. Other proximity items will be not accepted
even if they have the same appearance.
IMPORTANT:
IMPORTANT:
Once a valid PIN code has been introduced, the
display will show the 1st memory position.
Use "UP" and "DOWN" arrows to select the
desired position, from 1 to 500.
Several cards or key holders can be recorded in one
memory position. Remember that the maximum
number of cards or key holders (users) is 500.
When the display shows the desired memory position,
approach the card or key holder to be recorded.
The display will shows the number of cards
recorded in this position (including the one you are
recording). This number will be shown with a dot
on its right bottom part. The display will show the
selected memory position again.
If you are trying to record an already existing card,
the display will show the memory position where
recorded, coming back to the position you are
trying to record it.
Repeat the above steps to record the rest of cards.
To erase existing cards from a specified memory position,
use "UP" and "DOWN" arrows till the display shows
the desired position. Press C button during 3 seconds:
the display will show the number of cards recorded
in this position and will confirm the progress by
showing the message – – –.
To erase all the existing cards, press C button during
15 seconds aproximately: the display will show the
message "IP" once the memory is empty.
C
The module will exit from the programming mode afte 20 seconds of no operation.
The display and the led on the front part of the module will be turned off.
MODULE PROGRAMMING
MODULE PROGRAMMING

LOCK RELEASE INSTALLATION
76
4Plus operation mode.
C
Use this operation mode to connect the module to a C4Plus access control system.
In this case, the C4Plus relays will be activated instead of the module internal relay.
Use the PIN code to enter into programming mode, as it's described on page 4.
In case of valid code, the display will show the selected
operation mode (C4P). In case of wrong code,
the display will show the message "E–5" during
10 seconds and will automatically exit from the
programming mode.
M 4 x 8
f3,5 x 25
DIN-7972
DIN-963
IMPORTANT: a varistor and a diode are supplied with this proximity reader.
In case to connect an a.c. lock release, place the varistor
on the lock release terminals directly.
In case to connect an d.c. lock release, place the diode
on the lock release terminals directly. Special attention
on polarity is required.
IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT:
+
-
a.c. lock release d.c. lock release
1N4007
MODULE PROGRAMMING
In this mode, the cards are recorded on the C4Plus memory instead of the memory module.
DIRECTORPlus software will be necessary to manage the C4Plus memory. However, one
of the C4Plus relays must be assigned to the proximity reader module.
Use "UP" or "DOWN" arrows to select a C4Plus relay.
The display will show the following messages:
C–1 (relay 1), C–2 (relay 2), C–3 (relay 3) or
C–4 (relay 4).
To exit from the programming mode, wait 20 sec.
from the last operation.
If the lock release will be installed in a metal door, use a
Ø3,5mm. drill and tap the hole. In case of wood door,
use a Ø3mm. drill.
ock release installation.
L

9
8
CVCPL1L2 P
CN1
-
~1~2 SEC
~~ PRI
~~
CVCVCO INHCPL1L2 P CN1
-
~1~2 SEC
~~ PRI
~~
CN1
CV+CV- D Aout Ain Vin- Vin+ MallaVout+Vout-+
-
2
S1SEC
+
-
PRI
~~
+
-
2
S1
+
-
2
S1
+
-
INSTALLATION DIAGRAMS INSTALLATION DIAGRAMS
EL550, EL554 or EL555
sound modules
3502/AL
Access control module
Mains
TF-104
transformer
One access door audio systems with 4+'n' installation.
ombined on 'Stadio Plus'
Cdoor panels.
EL551 sound module
3502/AL
Access control module TF-104
transformer
Mains
Several access doors systems with 4+'n' installation.
ombined on 'Stadio Plus'
Cdoor panels.
EL500 or EL501 microprocessed modules
or coded panels
3502/AL
Access control module
The wiring of the access control module on 'Stadio Plus' door panels will depends
on the installation type. Use the power supply connected to the door panel.
Audio and video systems with digital installation.
FA-Plus/C or FA-Plus
power supplies
Mains
tand alone operation.
S
The enclosed diagram uses a TF-104 transformer (12Va.c.) as access control module feeder.
Módulo de control de accesos
3502/AL
SEC
~~
PRI
~~
Mains
2
S1
+
-
TF-104
transformer

Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.
golmar@golmar.es
www.golmar.es
Table of contents
Popular Gateway manuals by other brands

Kuhnt
Kuhnt AS55 Series Service manual

TelcoBridges
TelcoBridges TMG3202 Quick installation guide

SolarEdge
SolarEdge SE1000 installation guide

Telstra
Telstra Elite user guide

Nortel
Nortel BSG12 Regulatory and safety information

Dwyer Instruments
Dwyer Instruments UHH-BTG Specifications-installation and operating instructions