SUMMIT-MULTI – INSTALLATION/OPERATION MANUAL
5IM-OF-K6C0-01 Jun/11
13
EVO
Model Burner Input Nozzle Pump Air
Setting Turbulator Output Blower Motor Heating CFM
USGPH L/h Btu/h (psi) Btu/h Kw (inches) (hp)
K6C-G2-K163-F5
Beckett AFG F3 0.90 3.40 126,000 0.75 70B 150 0/10 - 109,000 32 GT 12-10 3/4 hp 1210*
Beckett AFG F6
1.02 3.85 142,800 0.85 70B 150 0.5/5 - 122,000 36
GT 12-10 3/4 hp
1360*
1.22 4.64 170,800 1.00 70B 150 1/5 - 143,000 42 1590*
1.35 5.10 189,000 1.20 70B 130 1/7 - 163,000 48 1810*
K6C-N2-K129-F5 Beckett NX-LH
0.94 3.55 131,600 0.75 60A 160 2.2 - 115,000 34 GT 12-10 3/4 hp 1280*
1.06 4.00 148,400 0.85 60A 155 3.7 - 129,000 38 1440*
K6C-N3-K164-F5 Beckett NX-LB
1.22 4.64 170,800 1.00 60B 150 2.5 - 149,000 44 GT 12-10 3/4 hp 1660*
1.35 5.10 189,000 1.10 60B 150 4.0 - 164,000 48 1820*
K6C-E3-K160-F5 Riello 40 F5
0.92 3.48 128,800 0.75 60W 150 3.2 1.0 107,000 31
GT 12-10 3/4 hp
1190*
1.04 3.94 145,600 0.85 60W 150 3.3 2.0 122,000 36 1355*
1.22 4.64 170,800 1.00 60W 150 3.4 2.5 143,000 42 1590*
1.35 5.10 189,000 1.10 60W 150 4.0 3.5 157,000 46 1740*
Direct Vent / Evacuation directe
K6C-V3-K145-F5 Riello 40 BF5**
0.92 3.48 128,800 0.75 70B 150 4.5 1.5 107,000 31
GT 12-10 3/4 hp
1190*
1.04 3.94 145,600 0.85 60W 150 5.0 2.0 122,000 36 1355*
1.22 4.64 170,800 1.00 60W 150 6.2 2.5 143,000 42 1590*
* Approximately 90 Btu/h CFM
**Cannot be used in conjunction with an air conditioning coil or any device that will increase
the static pressure.
MAX
Model Burner Input Nozzle Pump Air
Setting Turbulator Output Blower Motor Heating CFM
USGPH L/h Btu/h (psi) Btu/h Kw (inches) (hp)
K6C-G2-K163-E5
Beckett AFT F3 0.90 3.40 126,000 0.75 70B 150 0/10 - 109,000 32 GT 12-10 3/4 hp 1210*
Beckett AFG F6
1.02 3.85 142,800 0.85 70B 150 0.5/5 - 122,000 36
GT 12-10 3/4 hp
1360*
1.22 4.64 170,800 1.00 70B 150 1/5 - 143,000 42 1590*
1.35 5.10 189,000 1.20 70B 130 1/7 - 163,000 48 1810*
K6C-N2-K129-E5 Beckett NX-LH
0.94 3.55 131,600 0.75 60A 160 2.2 - 115,000 34 GT 12-10 3/4 hp 1280*
1.06 4.00 148,400 0.85 60A 155 3.7 - 129,000 38 1440*
K6C-N3-K164-E5 Beckett NX-LB
1.22 4.64 170,800 1.00 60B 150 2.5 - 149,000 44 GT 12-10 3/4 hp 1660*
1.35 5.10 189,000 1.10 60B 150 4.0 - 164,000 48 1820*
K6C-E3-K160-E5 Riello 40 F5
0.92 3.48 128,800 0.75 60W 150 3.2 1.0 107,000 31
GT 1 2-
10 1 hp
1190*
1.04 3.94 145,600 0.85 60W 150 3.3 2.0 122,000 36 1355
1.22 4.64 170,800 1.00 60W 150 3.4 2.5 143,000 42 1590
1.35 5.10 189,000 1.10 60W 150 4.0 3.5 157,000 46 1740*
Direct Vent / Evacuation directe
K6C-V3-K145-E5 Riello 40 BF5**
0.92 3.48 128,800 0.75 70B 150 4.5 1.5 107,000 31
GT 12-10 1 hp
1190*
1.04 3.94 145,600 0.85 60W 150 5.0 2.0 122,000 36 1355*
1.22 4.64 170,800 1.00 60W 150 6.2 2.5 143,000 42 1590*
* Approximately 90 Btu/h CFM
**Cannot be used in conjunction with an air conditioning coil or any device that will increase
the static pressure.
Note: The turbulator & air settings found in this section should be used as a guide.