©McDonald’s Corporation · Planned Maintenance Manual · March, 2017
Clean Condenser Coil & Check Drawer Gaskets
High Capacity Freezer-Refrigerator Combo (HCFRC18.01P)Quarterly
RF08Q01
The condenser coil must be cleaned regularly to ensure the unit operates at peak performance.
The drawer gaskets condition must be check to ensure the unit is sealed properly. Failure to do
so could result in food product quality risks, premature refrigeration failure, additional energy
usage, and voiding of warranty.
For 24-hour restaurants: during slow period
Turn off unit
Press and hold right lower
button of controller for 5
seconds to turn off the
unit.
Replace slotted panel
Reinstall panel by
aligning tabs with slots
on each side of
condenser housing.
Push panel in and down
until secure.
Make sure to check that
the panel is tightly
secured.
Remove slotted panel
Lift panel up to clear tabs
at each side of panel.
Check Drawer gaskets
Check to see if door
gasket broken. If the
door gasket is broken,
and cannot seal the
cabinet properly, please
call 800-521-3987 to
order replacement
gasket.
Clean Condenser Coil
Using a soft bristled brush
remove any dirt present on
the coil.
Make sure to brush with
the direction of the fins.
Turn on unit
Press and hold right
lower button of
controller for 5 seconds
to turn on the unit.
.