Hanwha Vision SHB-V-3200HPR User manual

Outdoor Enclosure Kit
for Box Cameras
SHB-V-3200HPR
Quick Guide

view
OVERVIEW
3
INSTALLATION & CONNECTION
6
APPENDIX
12
Copyright
©2023Hanwha Vision Co., Ltd. All rights reserved.
Trademark
Each of trademarks herein is registered.The name of this product and other trademarks mentioned in this manual are the registered trademark of their
respective company.
Restriction
Copyright of this document is reserved. Under no circumstances, this document shall be reproduced, distributed or changed, partially or wholly, without
formal authorization.
Disclaimer
Hanwha Techwin makes the best to verify the integrity and correctness of the contents in this document, but no formal guarantee shall be
provided. Use of this document and the subsequent results shall be entirely on the user’s own responsibility. Hanwha Techwin reserves the
right to change the contents of this document without prior notice.
Design and specications are subject to change without prior notice.
Outdoor Enclosure Kit
for Box Cameras
Quick Guide

overview
CONTENTS
OVERVIEW
4
4 What’s Included
INSTALLATION & CONNECTION
5
5 Installation
3_ Contents

overview
4_ Overview
WHAT’S INCLUDED
Please check if your camera and accessories are all included in the product package. Each item may be package in its' own box.
Appearance Item Name Quantity
HOV32K2A700
OUTDOOR HOUSING
WITH POE/HPOE
1
WBJA
WALL BRACKET
WITH BALL JOINT
1
IRH30L
IR ILLUMINATOR
1
OSUPPIR
BRACKET FOR IR ILLUMINATOR
1
Appearance Item Name Quantity
MOUNT CAP
5
MOUNT CAP fastener 1
M10 x L22 screw (to attach the install bracket)
4
M8 x L20 screw (to attach the housing)
4
M3 x L6 screw
(to attach the bracket adaptor and media convert) 4
M10 x L12 wrench bolt (to attach SBP-300WM/WMW) 4
M10 x L20 wrench bolt (to attach SBP-300WM1/WMW1) 4
M4 x L8 screw (to attach the media convert) 2
Note: A PoE/PoE+ switch or injector is required, not included.

Quick Installation of housing, wall mount, and illuminator:
Fasten the plate (1) between the bottom of the housing (2)
and the bracket (3) using the supplied screws (4).
Fasten the top bracket (1) to the illuminator using the
screws and washers (2) supplied.
Fasten the illuminator and bracket using the nut and the
washer.
Set the vertical and horizontal angle, checking the resulting
illumination range on the screen. Tighten all the screws.
Twilight sensor activation threshold adjustment
The illuminator has an integrated twilight sensor that
allows its automatic activation and deactivation at
predefined luminous conditions.
The twilight sensor is set in the factory at a
predetermined luminous level, suitable for most
installations (approximately 50lx). If you want to
adjust the threshold, loosen the plug on the
illuminator rear and make adjustments with a
screwdriver.
By rotating the trimmer clockwise, the night mode
changeover occurs at a greater luminous value. By
rotating the trimmer counter-clockwise, the night mode
changeover is delayed to a lower luminous value.
Wait for appropriate brightness before switching on the
illuminator. Rotate the trimmer slowly until the LED on
the side of the trimmer switches on. Once the
intervention threshold has been surpassed (LED on),
rotate it slightly in the opposite direction.
2
3
1
4
Switch-on
threshould
regulator
Photocell
Power supply
and control
1
2
2
5_ Installation

Opening the housing
Loosen the 2 screws on the side of the housing, allowing
the cover and the upper half of the body to pivot open on
the hinge.
Slide removal
To remove the slide it is necessary to partially unscrew the
fixing screws as shown in the figure.
Move the slide by sliding it until the holes coincide with the
slide locking screws.
Installation of cable glands
Inside the supply are 3 cable glands that must be
installed at the bottom of the housing as shown in the
figure. The cable glands that are not used must be
sealed with a cap to avoid water entering the housing.
1.1.1 Ethernet cable installation
Insert the Ethernet cable in the gasket and block it as
shown in the figure.
Fit the gasket (1) to the cable gland M20 (2). Fasten the
cable gland to the bottom of the housing (3) using the
M20 nut.
Pay attention to the fixing. Tightening torque: 7Nm.
Pass the cable withRJ45 connector (5) through the M20
cable gland (2). Tighten the cable gland cap (6).
How to install the camera (not included)
The correct operation of the equipment, within the
temperature range indicated, is guaranteed only if you use
a camera and lens with temperature limits equal to at least
-10°C and +60°C (14°F to 140°F)
Mount the camera (not included) using the supplied
screws (1) and spacers (2).
Apply at least one spacer to guarantee electrical isolation
between the slide and the camera.
4
1
2
5
6
3
3
2
1
6_ Installation

Position the camera lens (not included) close to the glass
to avoid visual interference or optical reflections.
Connect the camera to the J2 connector (3) (PoE+ OUT)
Refit the slide in its housing and fix the previously
loosened screws.
Connection of the illuminator
Connect the illuminator to the J6 terminal as described
in the diagram below.
CONNECTION
OF
THE
ILLUMINATOR
Illuminator
Terminal
J6
Green
(telemetry)
1
Red
(telemetry)
2
White
(power supply)
3
Black (power supply)
4
1
2
3
4
7_ Installation

PoE+ cable connection
Connect the PoE+ cable from the Power Injector to the J1
connector.
Before powering the device, you must set the maximum
power consumption of the housing operating on dip switch
SW1, below.
Configuration
Before powering the device, you must set the
maximum power consumption of the housing to ON for
PoE+ class 4 (25.5W maximum output)
operating on dip
switch SW1. PoE+ is required due to the use of the
illuminator, defroster, & PoE+ camera.
POWER
CONSUMPTION
CONFIGURATION
SW1
Maximum
power
ON
PoE+ Class 4 (25.5W max)
Switching on
The automatic pre-heating (De-Ice) process can start
whenever the device is switched on and the ambient
temperature is below 0°C (+32°F). The procedure is
necessary to guarantee correct operation of the devices
even at low temperatures.
The duration ranges depending on environmental conditions
(from 60 minutes up to 120 minutes).
During power on and boot up the device reads the status
of the dip switch and automatically detects all of the
connected options for the correct power management of
the housing.
The LEDs shown in the figure allow you to check the
product's operating status.
8_ Installation

The LEDs shown in the figure allow you to check the
product's operating status.
OPERATING
STATUS
LED
LED
Status
Apparatus
Status
LD1 (Power
supply)
Off
The device is
not powered
On
The device is correctly powered
LD2
(Camera)
Off
The camera is not connected or
Cold Start is
active
On
The camera is correctly powered
1
flashing
The camera has a low identification
resistance
2 flashings
The camera has a high identifica
tion resistance
5 flashings
The camera has an excessive power
consumption
9 flashings
The camera requires more power
than the
available
LD3
(Demi
sting)
Off
Demisting was not correctly
detected
1
flashing
Standard demisting is inactive
2 flashings
The anti-ice system (optional) is
inactive
On
Demisting, or anti-ice system, is in
operation
LD4
(Heater)
Off
Heating is not available or power
available is
not sufficient
1
flashing
Heating is inactive
On
Heating is active
LD5
(Illumi
nator)
Off
The illuminator (optional) is not
detected or
the available power is
not sufficient
1
flashing The illuminator is correctly
powered
(illuminator activation is
controlled by the
photocell)
LD6
(Delayed
activation)
Off
Heating is
not available
1
flashing
The pre-heating procedure is
inactive
On
The pre-heating procedure is
underway
Procedure to assemble the camera with the lens.
(Note: Camera and Lens are not included with the
housing.)
Carefully insert the lens screw threads into the camera body
and fully tighten. Attach the lens iris cable into the camera
body connector. Adjust the lens zoom / focus levers. You
may need to perform a Focus Initialization to adjust the
sensor position after installation. Then perform a Simple
Focus.
Please consult the camera user manual and Quick
Guide for additional configuration steps that may be
necessary, such as configuring apassword and IP
addressing.
Please note that camera and lens are to be
purchased separately. Refer to mount selection tool
for camera compatibility
9_Installation

PT01-004102A
Hanwha Vision America
500 Frank W. Burr Blvd. Suite 43 Teaneck, NJ 07666
Toll Free +1.877.213.1222 Direct +1.201.325.6920
Fax +1.201.373.0124
www.hanwhavisionamerica.com
Vision
Other manuals for SHB-V-3200HPR
1
Table of contents
Other Hanwha Vision Enclosure manuals