FLOOR LEVEL
REINFORCED WALL SECTION
4 x F
completely finished before normal operation.
R011063
reset and make sure the procedure has
Page: 5 of 5
18. Screw two m8x16mm screws(F) into each side
of the rear wall mount brackets(1), eight total in the
complete assembly. Only screw the bolts in half
way. Do not fully tighten until the frame is fully
mounted.
19. Using two people, lift the assembled frame onto
the rear wall mount bracket(1) so that the front
shrouds(2) lock onto the m8x16mm bolts(F).
NOTE: Once mounted the table legs(3) should not
feel like they are being torqued in or out, and the
assembly should be level.
Warning: If the legs are being heavily torqued into
the rear wall mounts(1) this will cause the
mechanism to bind and fail. Remove the assembly
from the wall, make slight adjustments to the frame
as needed, retighten, and reinstall.
Once the frame is mounted and leveled fully
tighten the m8x16mm bolts(F) to lock in place.
20. Plug in the 120v power cord(9) into an
appropriate 110V wall receptacle.
21. Perform initial reset by pushing the down-button
until the table stops. Push the down-button again
and "hold it" until the legs stop moving.
22. The power cord(9) should be restrained to
ensure no excess slack when the mechanism is
adjusted to its highest point, and should not be
over stretched causing the cord to pull out of the
wall receptacle.
Troubleshooting:Make sure that all cables are
correctly connected to the control box, legs,
control switch, and power source. Perform a new
F x 8 (m8x16mm)
4 x F
SX2 Wall Mount
1
1