scheme 3
( )difference to scheme 2 is solid fuel boiler application
apply to model PCWU 200K-2.3kW and PCWU 300SK-2.3kW
scheme 2
(difference to scheme 1 is circulation pump application)
apply to model PCWU 200K-2.3kW and PCWU 300SK-2.3kW
Symbols:
water pump or circulation pump
111 12 13
2345678 9 10
t
5K
t
5K
AT BT OUT D
IN external controller
R1
R2
Position in terminal block:
Circulation pump can be connected to terminal 1 and 2.
Then the pump will be controlled by controller (relay RL02).
Circulation pump with power more than 100W shall be
drived by additional contactor.
111 12 13
2345678 9 10
t
5K
t
5K
AT BT OUT D
IN external controller
R1
R2
Position in terminal block:
Boiler pump can be connected to terminal 3 and 4.
.
Temperature sensor T4(the boiler temperature BT) can be
connected to terminal 7 and 8. Sensor should be mounted
to place where it can indicate real output temperature
from boiler.
Then
the pump will be controlled by controller (relay RL09)
Boiler pump with power more than 100W shall be drived
by additional contactor.
scheme 4
(difference to scheme 2 is automatic boiler application)
apply to model PCWU 200K-2.3kW and PCWU 300SK-2.3kW
Controlling of automatic boiler can be realized in 2 ways:
1. Use terminal 9 and 11 to turn on/off boiler by closing or
opening one corresponding connection inside boiler.
2. Turn on/off bolier by giving corresponding temperature
values simulated by resistors R1 and R2. Reference values
of resistors are listed in next page. Attention! In such
application, the original temperature sensor from boiler
must be disabled.
hot water output
condensate discharge
flexiable hose inner ɸ21mm
connector 3/4"
in case of using metallic pipes,
isulation adapter shall be applied
(ie. adapter PA66 GF30)
connector 3/4"
in case of using metallic pipes,
isulation adapter shall be applied
(ie. adapter PA66 GF30)
electrical heater 1.5 kW
factory configuration
cold water input
air
T1
siphon before sewer
connected to safety valve
ambient temperature sensor
water circulation
hot water output
condensate discharge
flexible hose inner ɸ21mm
connector 3/4"
in case of using metallic pipes,
isulation adapter shall be applied
(ie. adapter PA66 GF30)
connector 3/4"
in case of using metallic pipes,
isulation adapter shall be applied
(ie. adapter PA66 GF30)
electrical heater 1.5kW
factory configuration
cold water input
air
T1
siphon before sewer
connected to safety valve
ambient temperature sensor
water circulation
automatic boiler D
(ie. gas, oil fired or electrical boiler)
solid fuel boiler B
boiler pump F
T4
hot water output
condensate discharge
flexible hose inner ɸ21mm
connector 3/4"
in case of using metallic pipes,
isulation adapter shall be applied
(ie. adapter PA66 GF30)
connector 3/4"
in case of using metallic pipes,
isulation adapter shall be applied
(ie. adapter PA66 GF30)
electrical heater 1.5kW
factory configuration
cold water input
air
T1
siphon before sewer
connected to safety valve
ambient temperature sensor
water circulation
boiler temperature sensor
111 12 13
2345678 9 10
t
5K
t
5K
AT BT
OUT C IN external controller
R1
R2
Position in terminal block:
OUT F
OUT C OUT F
20
Instruction manual
Heat pump water heater PCWU 200K-2.3kW/PCWU 300SK-2.3kW